• Title/Summary/Keyword: machinable ceramics

Search Result 48, Processing Time 0.022 seconds

Processing of Al2O3 Ceramics with a Porous Cellular Structure (셀 다공구조를 갖는 Al2O3세라믹스의 제조)

  • Lim, Byong-Gu;Lee, Lak-Hyoung;Ha, Jung-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.10
    • /
    • pp.574-579
    • /
    • 2007
  • Porous $Al_2O_3$ ceramics were prepared by the gelcasting foams method (a slurry foaming process) with acrylamide monomer. The foaming and gelation behavior was investigated with the parameters such as the type and concentration of surfactant, solid loading of slurry, and the concentrations of initiator and catalyst. Density, porosity, microstructure, and strength of the green and sintered samples were characterized. Of the four kinds of surfactants tested, Triton X-114 showed the highest foaming ability for the solid loading of 55-30 vol%. The gelation condition giving the idle time off min was found to set the foamed structure without significant bubble enlargement and liquid lamella thinning. The green samples were fairly strong and machinable and showed maximum strength of 2.4 MPa in diametral compression. The sintered samples showed densities of 10-36% theoretical (i.e. porosity 90-64%) with a highly interconnected network of spherical pores with sizes ranging from 30 to $600{\mu}m$. The pore size and connectivity increased but the cell strut thickness decreased with decreasing the solid loading. Flexural strength of 37.8-1.7 MPa was obtained for the sintered samples.

TENSILE STREGNTH BETWEEN MACHINABLE CERAMIC AND DENTIN CEMENTED WITH LUTING COMPOSITE RESIN CEMENTS (합착용 복합레진시멘트로 합착한 Machinable Ceramic과 상아질 사이의 인장강도에 대한 실험적 연구)

  • Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.487-501
    • /
    • 1998
  • In the case of CAD/CAM ceramic inlay restorations, if isthmus width is widened too much, it may cause fracture of remaining tooth structure or loss of bonding at the luting interface because of excessive displacement of buccal or lingual cusps under occlusal loads. So to clarify the criterior of widening isthmus width, this study was designed to test the tensile bond strength and bond failure mode between dentin and ceramic cemented with luting composite resin cements. Cylindrical ceramic blocks(Vita Cerec Mark II, d=4mm) were bonded to buccal dentin of 40 freshly extracted third molars with 4 luting composite resin cements(group1 : Scotchbond Resin Cement/Scotchbond Multi-Purpose, group2 : Duolink Resin Cement/ All-Bond 2, group3: Bistite Resin Cement/Ceramics Primer, and group4:Superbond C&B). Tensile bond test was done under universal testing machine using bonding and measuring alignment blocks(${\phi}ilo$ & Urn, 1992). After immersion of fractured samples into 1 % methylene blue for 24 hours, failure mode was analysed under stereomicroscope and SEM. Results: The tensile bond strength of goup 1, 2 & 4 was $13.97{\pm}2.90$ MPa, $16.49{\pm}3.90$ MPa and $16.l7{\pm}4.32$ MPa, respectively. There was no statistical differences(p>0.05). But, group 3 showed significantly lower bond stregnth($5.98{\pm}1.l7$ MPa, p<0.05). In almost all samples, adhesive fractures between dentin and resin cements were observed. But, in group 1, 2 & 4, as bond strength increased, cohesive fracture within resin cement was observed simultaneously. And, in group 3, as bond strength decreased, cohesive fracture between hybrid layer and composite resin cement was also observed. Cohesive fracture within dentin and porcelain adhesive fracture were not observed. In conclusion, although adhesive cements were used in CAD/CAM -fabricated ceramic inlay restorations, the conservative priciples of cavity preparation must be obligated.

  • PDF

CERAMIC INLAY RESTORATIONS OF POSTERIOR TEETH

  • Jin, Myung-Uk;Park, Jeong-Won;Kim, Sung-Kyo
    • Proceedings of the KACD Conference
    • /
    • 2001.05a
    • /
    • pp.235-237
    • /
    • 2001
  • ;Dentistry has benefited from tremendous advances in technology with the introduction of new techniques and materials, and patients are aware that esthetic approaches in dentistry can change one's appearance. Increasingly. tooth-colored restorative materials have been used for restoration of posterior teeth. Tooth-colored restoration for posterior teeth can be divided into three categories: 1) the direct techniques that can be made in a single appointment and are an intraoral procedure utilizing composites: 2) the semidirect techniques that require both an intraoral and an extraoral procedure and are luted chairside utilizing composites: and 3) the indirect techniques that require several appointments and the expertise of a dental technician working with either composites or ceramics. But, resin restoration has inherent drawbacks of microleakage. polymerization shrinkage, thermal cycling problems. and wear in stress-bearing areas. On the other hand, Ceramic restorations have many advantages over resin restorations. Ceramic inlays are reported to have less leakage than resin restoration and to fit better. although marginal fidelity depends on technique and is laboratory dependent. Adhesion of luting resin is more reliable and durable to etched ceramic material than to treated resin composite. In view of color matching, periodontal health. resistance to abrasion, ceramic restoration is superior to resin restorationl. Materials which have been used for the fabrication of ceramic restorations are various. Conventional powder slurry ceramics are also available. Castable ceramics are produced by centrifugal casting of heat-treated glass ceramics. and machinable ceramics are feldspathic porcelains or cast glass ceramics which are milled using a CAD/CAM apparatus to produce inlays (for example, Cered. They may also be copy milled using the Celay apparatus. Pressable ceramics are produced from feldspathic porcelain which is supplied in ingot form and heated and moulded under pressure to produce a restoration. Infiltrated ceramics are another class of material which are available for use as ceramic inlays. An example is $In-Ceram^{\circledR}$(Vident. California, USA) which consists of a porous aluminum oxide or spinell core infiltrated with glass and subsequently veneered with feldspathic porcelain. In the 1980s. the development of compatible refractory materials made fabrication easier. and the development of adhesive resin cements greatly improved clinical success rates. This case report presents esthetic ceramic inlays for posterior teeth.teeth.

  • PDF

The effect of microstructure of electrical discharge machinable silicon nitride on wear resistance (방전가공용 질화규소의 미세조직이 내마모에 미치는 영향)

  • 이수완;김성호;이명호
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.8 no.1
    • /
    • pp.111-116
    • /
    • 1998
  • Silicon nitride is hard and tough ceramic material. Hereby, mechanical machinability is very poor. It has also high electrical resistance. Silicon nitride of extremely high electrical resistivity becomes conductive ceramic composite by adding 30 wt% TiN. Ceramics with high electrical conductivity can be electrical discharge machined. Using by the Electrical Discharge Machining (EDM) technique. $Si_3N_4-TiN$ ceramic composite with high electrical conductivity is utilized to make metal working tool. These tool materials have severe wear problem as well as oxidation. Post HIP processing after sintering $Si_3N_4-TiN$ ceramic composites was performed. The tribological property of $Si_3N_4-TiN$ composite as a function of content of TiN was investigated in air, at room temperature. The hardness, fracture toughness, and flexural strength were compared with the wear volume. SEM observation of wear tracks can make an explanation of wear mode of $Si_3N_4-TiN$ composite.

  • PDF

Experimental Investigations on Micro End-milling Cutting Characteristics Comparison and Tool Wear Behavior of AlN-hBN Composites Sintered by Hot-pressing (열간가압소결에 의해 제조된 AlN-hBN 복합재료의 마이크로 엔드밀링 절삭특성 비교와 공구마모에 관한 실험적 연구)

  • Beck, Si-Young;Shin, Bong-Cheol;Cho, Myeong-Woo;Cho, Won-Seung
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.104-111
    • /
    • 2008
  • The objective of this study is to evaluate micro end-milling characteristics and tool wear behavior of AlN-hBN composites. First, AlN based composites with hBN contents in the range of 10 to 20vol% were prepared by hot-pressing. Vickers hardness and flexural strength of the prepared composite specimens were measured and compared according to the vol% of hBN variations. Then, cutting force variations were measured and analyzed using a tool dynamometer during the micro end-milling experiments; and machined surface shapes and roughness were investigated using a 3D non-contact type surface profiler. After micro end-milling, worn tools were investigated using a tool microscope and SEM images. From the experimental results, it can be observed that the cutting forces decreased, and surface qualities were improved with increasing hBN contents. At low content of hBN, tool chipping was observed; and tool wear rate decreased with increasing hBN contents. The results of this study insist that proper machining conditions, including tool wear behavior investigation, should be determined for the micro end-milling of AlN-hBN composites for its further application.

Dental application of glass-ceramic materials for aesthetic restoration (심미수복을 위한 글라스-세라믹 재료의 치과 응용)

  • Bae, Tae Sung
    • The Journal of the Korean dental association
    • /
    • v.58 no.7
    • /
    • pp.435-442
    • /
    • 2020
  • Porcelain is the first ceramic material to be introduced into dentistry. Porcelain jacket crown was introduced by Dr. Charles H Land in 1886, which was an excellent aesthetic dental restoration but has not been widely used due to high firing shrinkage and low tensile strength. Then metal-ceramic system, which combines the esthetic properties of ceramics and the mechanical properties of metals, was introduced and nowadays it is still used in dental clinical field. However, the metal-ceramic system has shown some problems, such as increased lightness by reflection of light at opaque layer, shadow beneath the gingival line due to the block-out of light by metal coping, exposure of metal in margin part, bond failure between metal and porcelain, oxidation of metal coping during firing the porcelain, etc. Recently, along with the advance of fabrication methods of dental ceramics, the all-ceramic restorations with high esthetic and mechanical properties has increased and gradually replaced metal-ceramic restorations. Especially, CAD/CAM technology has opened a new era in fabricating the dental ceramic restorations. This overview will take a look at the past, present and future possibility of the dental ceramic materials.

  • PDF

Evaluation of marginal fidelity of copy-milled and CAD/CAM all ceramic crowns

  • Jeong Seung-Mi;Kang Dong-Wan;Wolf Christoph
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.243-249
    • /
    • 2001
  • Statement of the problem. The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems or Copy-milling systems there is a need for evaluating the quality levels of these new fabrication techniques. Purpose. This study was to evaluate the fitting accuracy of machined all-ceramic crowns made out of an industrially prefabricated feldspathic porcelain. Material and Methods. Three master models with different cutting depth (0.8mm/1.0mm/1.2mm)were produced using a palladium-silver alloy. A total of 36 working dies, 12 of each form, was used for the modellation of prototype resin copings and 36 additional crowns, 12 of each cutting depth, were produced by using the $CEREC^{(R)}2$ system for all crowns. The maginal fit of all 72 crowns was then evaluated on their respective master die at 54 circularly staggered points of measurement per crown under a fixation pressure of 30 N by using a computerized video image system. Results. The medians of the copy-milled $CELAY^{(R)}$ crowns ranged from 29 to $36{\mu}m$. The highest value for the marginal gap was found in group B (cutting depth 1.0mm) at $107{\mu}m$. The median for the $CEREC^{(R)}2$ crowns was found between 43.5 and $70{\mu}m$. The maximum values for all three groups ranged from $181{\mu}m$ to $286{\mu}m$. With $286{\mu}m$ the highest value for marginal gap was found in group C. the Kruskal-Wallis test and multiple comparisons analysis procedure revealed a significant influence of the production technique on the marginal fit in all three groups (p<0,02). Conclusion. 1. The $CELAY^{(R)}$ system is capable to produce all-ceramic crowns with a significantly better marginal fit than the $CEREC^{(R)}2$ system. 2. As far as premolar crowns produced with the $CEREC^{(R)}2$ system are concerned, the cutting depth has a significant influence on fitting accuracy. 3. The production of crowns with an acceptable marginal fit is possible with both systems. However, adhesive luting is recommended for milled feldspathic porcelain crowns.

  • PDF

A comparison of the fidelity of various zirconia-based all-ceramic crowns fabricated with CAD/CAM systems (수종의 CAD/CAM 시스템으로 제작한 지르코니아 기반 완전도재관의 적합도 비교)

  • Kim, Sung-Jun;Jo, Kwang-Hun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.148-155
    • /
    • 2009
  • Statement of problem: The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems there is a need to evaluate the quality levels of these new fabrication techniques. Purpose: This study is to evaluate the crown fidelity(absolute marginal discrepancy and internal gap) of various zirconia-based all-ceramic crowns fabricated with different CAD/CAM(computer-assisted design/computer-assisted manufacturing) systems and conventional cast metal-ceramic crowns. Material and methods: A resin tooth of lower right second premolar was prepared. After an impression was taken, one metal master die was made. Then 40 impressions of metal master dies were taken for working dies. 10 crowns per each system were fabricated using 40 working dies. Metal-ceramic crowns were cast by using the conventional method, and Procera, Lava, and Cerec inLab crowns were fabricated with their own CAD/CAM manufactruing procedures. The vertical marginal discrepancies and internal gaps of each crown groups were measured on a metal master die without a luting agent. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test. Results: 1. Vertical marginal discrepancies were $50.6{\pm}13.9{\mu}m$ for metal-ceramic crowns, $62.3{\pm}15.7{\mu}m$ for Procera crowns, $45.3{\pm}7.9{\mu}m$ for Lava crowns, and $71.2{\pm}2.0{\mu}m$ for Cerec inLab crowns. 2. The Internal gaps were $52.6{\pm}10.1{\mu}m$ for metal-ceramic crowns, $161.7{\pm}18.5{\mu}m$ for Procera crowns, $63.0{\pm}10.2{\mu}m$ for Lava crowns, and $73.7{\pm}10.7{\mu}m$ for Cerec inLab crowns. Conclusion: 1. The vertical marginal discrepancies of, 4 crown groups were all within the clinically acceptable range($120{\mu}m$). 2. The internal gaps of LAVA, Cerec inlab, and metal-ceramic crowns were within clinically acceptable range except Procera crown($140{\mu}m$).