• Title/Summary/Keyword: luminance performance

Search Result 294, Processing Time 0.024 seconds

Efficient Generation of Image Identifiers for Image Database (정지영상 데이터베이스의 효율적 인식자 생성)

  • Park, Je-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.3
    • /
    • pp.89-94
    • /
    • 2011
  • The image identification methodology associates an image with a unique identifiable representation. Whenever the methodology regenerates an identifier for the same image, moreover, the newly created identifier needs to be consistent in terms of representation value. In this paper, we discuss a methodology for image identifier generation utilizing luminance correlation. We furthermore propose a method for performance enhancement of the image identifier generation. We also demonstrate the experimental evaluations for uniqueness and similarity analysis and performance improvement that have shown favorable results.

Preliminary Field Test on Daylighting Performance of Perpendicular Light Pipe System (수직형 라이트파이프의 채광성능에 관한 예비평가)

  • Shin, Hae Mi;Park, Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.53-60
    • /
    • 2008
  • The daylighting affects on the human biological cycles and physiological alterations. Daylighting is also an important element in visual comfort and it sometimes influences the quality of vision. Therefore the absence of natural light during the day brings contradictory result. To solve the problems of natural light lack and provide sufficient daylight in interior spaces, it might be necessary to apply some daylighting systems. One of these systems, light pipe system, which is simple, cheep and easily constructed, is very useful to apply for small buildings. The light pipe is simple means of directing daylighting (diffuse and direct lighting)into interior space. In order to application of light pipe system in Korea, it is necessary to optical data of light pipe system. This study aims to evaluate preliminary experiment of the daylighting environment of light pipe system. Light pipe system, that aspect ratio is 1:2(diameter and length), was installed in a windowless mock-up with $27m^2$. The mock-up model was constructed as a prototype of Korean office surface. Illuminance was measured with a Topcon IM-5 Luxmeter to evaluate the distribution of the illuminance on a floor. The indoor and outdoor illuminance and the internal/external illuminance ratio are compared to discuss with in the graphs. Luminance was measured with Radiant imaging Promertric 1400 that is digital photometer to evaluate the distribution of luminance on interior surface. The contrast of luminance is discussed with table and graphs.

Comparative Daylighting Performance Analysis of Offices in 1/10, 1/5 Scale Models and Mock-up Model (실물대모형 및 1/5, 1/10축소모형의 자연채광 성능평가에 관한 비교분석)

  • Baik, Seung Heon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.6 no.4
    • /
    • pp.25-32
    • /
    • 2006
  • Mock-up model can be applied to measure accurate performance data but difficult to apply the variables in experiment. There can be a slight experiment errors in Scale model, but various parameters can be applied for a objective experiment. This paper aims to compare the daylighting performance in 1, 1/5, 1/10 scale model of offices and analyze the experiment errors to certificate the influence of model experiment. To analyse daylighting performance, a comparison of a Mock-up model, sized $12.0m(w){\times}7.2m(l){\times}3.7m(h)$, designed for experimentation of daylighting systems and its 1:5, 1:10 scale model. It has an identical configuration of reference room and the test room. For the test room, the lightshelf system was designed as Micro-4 reflective material. To assess work plane illuminance and light factor, photometric sensors of each room were installed at work-plane(6 points) and exterior horizontal illuminance (1 point). And luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio and luminance are discussed.

An Area Look-Up-Table based Controller for Improving Performance of Luminance on Lighting Passive Matrix Organic Light Emitting Diodes Panels

  • Juan, Chang-Jung;Tsai, Ming-Jong;Liu, Chia-Lin;Mo, Chi-Neng
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1487-1490
    • /
    • 2005
  • This study proposes a controller with the techniqu e of voltage -compensated driver for producing grayscaled pictures on passive matrix organic light emitting diodes (PMOLEDs) panels; especially, the controller overcomes the problem of luminance nonuniformity on displaying pictures. Because the controller is a voltage type driver, the output impedance of the driver is much less than that of the current-type driver. Hence, the controller provides a better electron-optical response than those of traditional current drivers. An area compensated look-up table (ACLUT) is designed in data feeding paths for removing luminance non-uniformity; thus, the proposed controller provides nearly 95% luminance uniformity.

  • PDF

Evaluation of daylighting performance of bar-type mirror reflector system in tunnel (터널 적용 바형식 반사거울시스템의 채광성능 평가)

  • Lee, Beom-Seok;Joo, Jae-Sung;Jeong, In-Young;Kim, Min-Sung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.93-105
    • /
    • 2012
  • The basic study was preceded for reducing maintenance and power cost of lighting fixture applying daylighting because most of the tunnel lighting depend on the artificial lighting. This study aims to evaluate the daylighting performance of daylighting performance of bar-type mirror reflector system in tunnel. Illuminance and luminance was measured. As a result of horizontal illuminance measurements, it was satisfied in tunnel recommended illuminance (KSA 3703) that total average was 1,170 lx increased 6.5 times more than this system was not used. Also, as a result of evaluating driver's glare on the opposite lane, glare did not occur and the luminance ratio was 3.01 which satisfies the luminance ratio standard 10.

Electricla Properties of Xe Plasma Flat Lamp (Xe 플라즈마 평판 램프의 전기적 특성)

  • Choi, Yong-Sung;Cho, Jae-Cheol;Hong, Kyung-Jin;Lee, Woo-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.35-38
    • /
    • 2006
  • As a display becomes large recently, Acquisition of high luminance and Luminance uniformity is becoming difficult in the existing CCFL or EEFL backlight system. So, study for a performance enhancement has enforced. but lamp development of flat type is asked for high luminance and a luminance uniformity security in of LCD and area anger trend ultimately. In this paper, we changed a tip shape of an electrode for production by the most suitable LCD backlight surface light source, and confirmed discharge characteristic along discharge gas pressure and voltage, and confirmed electric field distribution and discharge energy characteristic through a Maxwell 2D simulation. Therefore the discharge firing voltage characteristic showed a low characteristic than a rectangular type and round type in case of electrode which used tip of a triangle type, and displayed a discharge electric current as a same voltage was low.

  • PDF

Luminance Projection Model for Efficient Video Similarity Measure (효율적인 비디오 유사도 측정을 위한 휘도 투영모델)

  • Kim, Sang-Hyun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.2
    • /
    • pp.132-135
    • /
    • 2009
  • The video similarity measure is very important factor to index and to retrieve for video data. In this paper, we propose the luminance projection model to measure the video similarity efficiently. Most algorithms for video indexing have been commonly used histograms, edges, or motion features, whereas in this paper, the proposed algorithm is employed an efficient measure using the luminance projection. To index effectively the video sequences and to decrease the computational complexity, we calculate video similarity using the key frames extracted by the cumulative measure, and compare the set of key frames using the modified Hausdorff distance. Experimental results show that the proposed luminance projection model yields the remarkable accuracy and performance than the conventional algorithm.

  • PDF

Evaluation of luminance performance of scintillating film for monitoring the position of a radioactive source in an NDT apparatus (비파괴검사 장치 내 방사선원 위치감시용 섬광필름의 발광성능 평가)

  • Lee, Kyung-Jin;Yun, Jeong-Ick;Park, Byung-Gi;Kim, Sin;Lee, Bong-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.13-17
    • /
    • 2005
  • In domestic nondestructive testing(NDT) field, there have recently been radiation exposure accidents due to a disregard for confirmation of the position of radioisotope during the test. In order to prevent these kinds of accidents, a scintillating film has been developed. The scintillating film that can convert gamma-ray to visible light has a function of the position detection of radioisotope in a opaque guide tube of an NDT apparatus. The aim of this study is to enhance the visibility performance of the scintillating film and find out the best configuration of the scintillating film. In order to find appropriate materials for the scintillating film, various inorganic scintillating materials were evaluated in this work. An absolute luminance of the scintillating films was measured by luminance meter for evaluation of visibility performance. Ir-192 gamma projector was used for NDT apparatus. The experiment shows that the scintillating film with reflective layer was the more effective performance for visibility. The higher mixing ratio of scintillating material to binding material, the higher luminance was measured. $Gd_2O_2S(Tb)$ inorganic powder as the scintillating materials had the best performance for visibility of the scintillating film. The developed scintillating film helps to ensure safer environment to the operators.

  • PDF

Controller with Voltage-Compensated Driver for Lighting Passive Matrix Organic Light Emitting Diodes Panels

  • Juan, Chang Jung;Tsai, Ming Jong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.673-675
    • /
    • 2004
  • This study proposes controller with voltage-compensated drivers for producing gray-scaled pictures on passive matrix organic light emitting diodes (PMOLEDs) panels. The controller includes voltage type drivers so the output impedance of the driver is far less than that of the current-type driver. Its low output impedance provides better electron-optical properties than those of traditional current drivers. A free running clock and a group of counters are applied to the gray-scaled function so that phase lock loop (PLL) circuit can be reduced in the controller. A pre-charge function is used to enhance performance of the luminance of an active OLED pixel. As a result, distribution of the low gray level portion is achieved linear relationship with input data. In this work, the digital part of the proposed controller is implemented using FPGA chips, and analog parts are combined with a digital-analog converter (DAC) and analog switches. A still image is displayed on a $48^{\ast}64$ PMOLEDs panel to assess the luminance performance fir the controller. Based on its cost requirement and luminance performance, the controller is qualified to join the market for driving PMOLEDs panels.

  • PDF

Design and Installations of Road Lighting for Arterial Roads to Provide the Optimal Values of Light Technical Parameters (야간의 도로조명 상황에서 최적의 도로조명기준을 나타낼 수 있는 가로등의 설계와 배치에 관한 연구)

  • 김기혁
    • Journal of Korean Society of Transportation
    • /
    • v.9 no.2
    • /
    • pp.41-56
    • /
    • 1991
  • The aim of this research is designing road lighting installations(arrangement, mounting height spacing and overhang) which produce a certain level and distribution of luminance together with minimal glare. These can be varied over a limited range for a given luminance and road surface to achieve the required installation performance. In Korea there are no code of practice which lays down recommended performance criteria (Lavg, Uo, Ul, G, TI) with practical design guidance on how to achieve them. In case study design rules and current installation of road lighting in daegu city are analysed. The core of research are suggesting a new performance criteria and providing a set of table giving the maximum lognitudinal spacing between successive luminaires. The result of this research prescribes the combination of height and spacing for various road widths and arrangements which will achieve a specified minimum performance on straigt roads for particular luminaire and a particular road surf-ace.

  • PDF