• Title/Summary/Keyword: low vision

Search Result 703, Processing Time 0.024 seconds

Vision-Based Dynamic Motion Measurement of a Floating Structure Using Multiple Targets under Wave Loadings (다중 표적을 이용한 부유식 구조물의 영상 기반 동적 응답 계측)

  • Yi, Jin-Hak;Kim, Jin-Ha;Jeong, Weon-Mu;Chae, Jang-Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1A
    • /
    • pp.19-30
    • /
    • 2012
  • Recently, vision-based dynamic deflection measurement techniques have significant interests and are getting more popular owing to development of the high-quality and low-price camcorder and also image processing algorithm. However, there are still several research issues to be improved including the self-vibration of vision device, i.e. camcorder, and the image processing algorithm in device aspect, and also the application area should be extended to measure three dimensional movement of floating structures in application aspect. In this study, vision-based dynamic motion measurement technique using multiple targets is proposed to measure three dimensional dynamic motion of floating structures. And also a new scheme to select threshold value to discriminate the background from the raw image containing targets. The proposed method is applied to measure the dynamic motion of large concrete floating quay in open sea area under several wave conditions, and the results are compared with the measurement results from conventional RTK-GPS(Real Time Kinematics-Global Positioning System) and MRU(Motion Reference Unit).

Comparison of Contrast Sensitivity at Near Between Functional Progressive Addition Lenses and Sigle Vision Lenses (기능성 누진가입도렌즈와 단초점렌즈의 근거리 대비감도 비교)

  • Kim, Chang-Jin;Kim, Hyun Jung;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.381-388
    • /
    • 2010
  • Purpose: This study was to compare the contrast sensitivity evaluated the visual ability at near wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition for 2 months. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses(EYE-T, Chemilens Co., Korea, ADD 0.75D) for 2 months. Corrected visual acuity at distance and near and contrast sensitivity at near were tested right after wearing functional progressive addition lenses to compare wearing single vision lenses. And we had second test after 2 months later. Results: Comparing between test and retest, contrast sensitivity at near wearing functional progressive addition lenses was improved more than wearing single vision lenses at all spatial frequency of right, left and both eyes. Conclusions: There was considered that contrast sensitivity test is useful to evaluate the visual ability as well as quality of near work and can be applied variously.

Vision and Aging

  • Kim, In Suk;Hilz, Rudolf
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.9-13
    • /
    • 2002
  • It is well known that the maximum amplitude of accommodation decreases with increasing age.(Presbyopia). With single vision lenses presbyopia can be corrected only for one viewing distance. With progressive power lenses presbyopia can be corrected for all viewing distances. But there are some other changes in the visual system with age which can not be corrected by spectacle lenses. Pupillary diameter decreases and the light transmission of the ocular media decreases. Therefore old people need more light, they need better illumination. Cone density in the retina decreases, this is only one example for changes in the sensory system. These changes in the visual system cause changes in visual functions. At the age of 80 visual acuity has decreased to half. Contrast sensitivity for gratings decreases mainly for high spatial frequencies very important is the increase of stray light in the ocular media and therefore the increase of glare. Veiling luminance increases by a multiple of approximately 4, Dark adaptation gets slower and light sensitivity is approximately 2 log units (factor 100) less when the eye is completely dark adapted. Also colour vision gets worse, especially at low luminances. Elderly people have problems with visual tasks which require divided attention between foveal and peripheral vision. An example is the measurement of the useful field of view. This useful field of view be expanded (improved) by visual training.

  • PDF

Comparison on Accommodative Response Changes in the Normal Group and Convergence Insufficiency (정상군과 폭주부족군에서 조절반응 변화량의 비교)

  • Kwak, Ho-Weon;Lee, Se-Hee;Kwak, Hyung-Bin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.79-85
    • /
    • 2014
  • Purpose: This study investigated accommodative changes by measuring accommodative response, appearing on the normal and convergence insufficiency Group, by using both eyes open-view auto-refractometer (Nvision-K5001, shin-nippon, Japan). Methods: It carried out objective and subjective refractions, targeting 74 college students (54 males and 20 females) aged between 19 and 29 ($21.59{\pm}2.53$), spherical equivalent OD $-2.28{\pm}2.03$ D, OS $-2.18{\pm}2.01$ D, by measuring accommodative responses at full correction and under correction with plus lens +0.25, +0.50, +0.75 arbitrarily added. Results: In the group of normal and convergence insufficiency, the shorter fixation distances were, the greater accommodative lags showed. The group of convergence insufficiency showed the lesser changes of accommodative response than those of normal. But we found that the convergence insufficiency group had a little larger accommodative amplitude in the total fixation distances. The full correction of convergence insufficiency group and the under correction (+0.50 D) of normal were alike in the accommodative responses. We have also investigated that the correlation between accommodative responses and fixation distances was decreased steeply at the excessive low vision correction. Conclusions: Under correction (+0.50 D) in a near distance is expected to avoid unnecessary accommodative responses, make eyes relaxed and comfortable.

Effect of Leadership Program on Enhancing Leadership Skills in Children from Low-Income Families (리더십 프로그램이 저소득층 아동의 리더십 역량에 미치는 효과)

  • Kwon, Jinha;Kim, Eunhyun
    • Human Ecology Research
    • /
    • v.55 no.1
    • /
    • pp.57-66
    • /
    • 2017
  • This study investigates the effect of a leadership program to enhance leadership skills in children from low-income families. A total of 45 elementary school students participated in the 52-week leadership program. Five leadership scales, such as goal attainment, paradigm shifting skills, skills to lead others, human relationship skills, and sense of purpose, were measured through survey questionnaires before and after implementing the program. In addition, individual teacher interviews examined the influence of the program on students' leadership skills. This study found that participants showed significant improvement after implementing the program in the three domains of the leadership skills (goal attainment, paradigm shifting skills, and human relationship skills); however, the skills to lead others and sense of purpose did not significantly change. The leadership teachers also stated that the program influenced positively on students' leadership skills; in addition, students' behavioral changes were found by developing relationships with other children as well as contemplating and attempting to find a future dream and vision. The leadership program was effective to enhance leadership skills in children from low-income families. This study can provide the theoretical and practical foundations for the development and implementation of effective leadership programs that meet the needs of children from low-income families.

The Study on the Analysis of Road Surface Brightness of Low Mounted Road Lighting System (낮은 도로 조명의 노면 휘도 실태 분석에 대한 연구)

  • Kiho Nam;Chung Hyeok Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.3
    • /
    • pp.314-321
    • /
    • 2024
  • Low road lighting is a lighting device that complements the shortcomings of existing pillar-type street lights. It is a lighting device that emits light from the side of the road surface and adjusts the luminance of the road surface like a light carpet. In this paper, to achieve full commercialization, we analyzed the luminance of the installed road surface and studied whether lighting could replace existing road lighting. In this study, the LMK (Luminance Measurement Camera) LABSOFT program was used to measure and analyze the surface luminance of road lighting, and the RELUX program was used to evaluate and analyze the simulation performance to determine light-based lighting conditions. A study was conducted to determine whether replacing pillar-type road lighting with low-level road lighting in a real environment would ensure comfortable and safe night vision for drivers at night.

Study on the Preparation and Characterization of Ophthalmic Polymer with High and Low-Water Content

  • Lee, Min-Jae;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.61 no.6
    • /
    • pp.346-351
    • /
    • 2017
  • This study was planned considering the chain length, hydrophilicity, and hydrophobicity of the additives to be used in the polymerization, while various ophthalmic lenses that use various additives with similar water contents were manufactured before their optical and physical properties were compared and analyzed. With regard to the additives required for manufacturing high-, medium-, and low-water content lens groups, HEA (hydroxyethyl acrylate), PVP (polyvinylpyrrolidone), and NMV(N-methyl-N-vinylacetamide) were used as additives for preparing the high-water content lens group, HEMA(2-hydroxyethyl methacrylate), HPMA(hydroxypropyl methacrylate) and BD(1,4-butanediol) were used for the medium-water content lens group. For the low-water content lens group, BMA(buthyl methacrylate), BDDA(1,4-butanediol diacrylate), and Bis-GMA(bisphenol A glycerolate diacrylate) were used, respectively. The average water content of HEA was 40.14%; that of PVP, 39.63%; and that of NMV, 40.52%. The mean of water content was 35.92% for HEMA, 35.74% for BD, and 34.62% for HPMA. For the low-water content lens group, the mean of water content was 26.69% for BMA, 27.76% for BDDA, and 26.14% for Bis-GMA. With regard to the results of the water content measurement using a moisture analyzer, the average water content of the high-water content lens group was 41.34% for HEA, 42.62% for PVP, and 42.73% for NMV. Finally, for the low-water content lens group, the average water content was 28.62% for BMA, 28.82% for BDDA, and 28.32% for Bis-GMA. The measurements of the water contents of the lenses using the two methods showed that the water content and refractive index of the lenses were similar in all the lens groups. The measurements of the contact angles, however, showed a different wettability value for each lens with a similar water content. Also, the change tendency of the lens curvature according to the change of time showed that the change amount became larger and the recovery time became longer from the lens samples with a lower water content to those with a higher water content. Based on these results that will be helpful for the study of ophthalmic lenses.

Using High Brightness LED Light Source Controller for Machine Vision (고휘도 LED를 이용한 머신비전용 조명광원 제어기 개발)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.311-318
    • /
    • 2014
  • This paper is to introduce a lighting source controller using high brightness LED to create a clear and reliable condition for an accurate measurement and testing, which is a core technology in clinical image system and mechanical automation system. This controller is designed to supply a stable power in a constant-current system by installing a high brightness LED driver, and to improve the reproducibility of brightness by using 32-bit ARM processor core, dividing brightness quantity into 256 levels, making the remote control and the external interface possible, and preventing and digitizing the brightness inaccuracy caused by errors of resistance values. This controller enables the lighting range to be wide and possible in a low lighting level compared to analog, adds the RS-485 communication function, and makes it for the users to control the on-off function and the dimming level by receiving date from an external device.

The Study on Functional State, Self Efficacy, and Life Satisfaction in the Elderly with Decreased Visual Acuity (시력저하노인의 기능상태, 자기효능감, 삶의 만족에 관한 연구)

  • Cha, Ki Jung;Eun, Young
    • Journal of muscle and joint health
    • /
    • v.20 no.3
    • /
    • pp.225-234
    • /
    • 2013
  • Purpose: This purpose of study was to investigate the relationships among functional state, self-efficacy, and life satisfaction in the elderly with decreased visual acuity. Methods: The subjects were 162 elderly people from the G university hospital. Functional state was measured by Late-Life Function and Disability Instrument (LLFDI) and Minimum Data Set-Home Care version 2.0 (MDS HC 2.0). Self-efficacy and Life satisfaction were measured by the tool of Rho & Lee (2011) and Yoon (2007). Data were analyzed using t-test, ANOVA, Pearson's Correlation Coefficient, and logistic regression. Results: The daily life function was significantly associated with self-efficacy and vision decrease. The regression model with these two variables explained 35.6% of the variance of daily life function. IADL was significantly associated with vision decrease, age, gender, and self-efficacy. The regression model with the three variables explained 52.9% of the variance of IADL. Life satisfaction is significantly associated with self-efficacy, daily life function, vision decrease and IADL. The last regression model with the four variables explained 51.8% of the variance of life satisfaction. Conclusion: The levels of functional state, self-efficacy and life satisfaction in the elderly with decreased visual acuity were low. Self-efficacy was an important factor that influences on the functional state and life satisfaction. Therefore, nursing interventions that can enhance the self-efficacy are required in order to increase the functional state and life satisfaction in the elderly with decreased visual acuity.

Multiple Vehicle Recognition based on Radar and Vision Sensor Fusion for Lane Change Assistance (차선 변경 지원을 위한 레이더 및 비전센서 융합기반 다중 차량 인식)

  • Kim, Heong-Tae;Song, Bongsob;Lee, Hoon;Jang, Hyungsun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.2
    • /
    • pp.121-129
    • /
    • 2015
  • This paper presents a multiple vehicle recognition algorithm based on radar and vision sensor fusion for lane change assistance. To determine whether the lane change is possible, it is necessary to recognize not only a primary vehicle which is located in-lane, but also other adjacent vehicles in the left and/or right lanes. With the given sensor configuration, two challenging problems are considered. One is that the guardrail detected by the front radar might be recognized as a left or right vehicle due to its genetic characteristics. This problem can be solved by a guardrail recognition algorithm based on motion and shape attributes. The other problem is that the recognition of rear vehicles in the left or right lanes might be wrong, especially on curved roads due to the low accuracy of the lateral position measured by rear radars, as well as due to a lack of knowledge of road curvature in the backward direction. In order to solve this problem, it is proposed that the road curvature measured by the front vision sensor is used to derive the road curvature toward the rear direction. Finally, the proposed algorithm for multiple vehicle recognition is validated via field test data on real roads.