• 제목/요약/키워드: low temperature heating

검색결과 963건 처리시간 0.027초

미세 패턴 성형용 판형 금형의 급속 가열을 위한 유도가열기구 (Induction Heating Apparatus for Rapid Heating of Flat-Type Metallic Mold in Hot Embossing)

  • 홍석관;이성희;허영무;강정진
    • 소성∙가공
    • /
    • 제16권4호
    • /
    • pp.282-287
    • /
    • 2007
  • Hot embossing, one of Nanoimprint Lithography(NIL) techniques, has been getting attention as an alternative candidate of next generation patterning technologies by the advantages of simplicity and low cost compared to conventional photolithographies. A typical hot embossing usually, however, takes more than ten minutes for one cycle of the process because of a long thermal cycling. Over the last few years a number of studies have been made to reduce the cycle time for hot embossing or similar patterning processes. The target of this research is to develop an induction heating apparatus for heating a metallic micro patterning mold at very high speed with the large-area uniformity of temperature distribution. It was found that a 0.5 mm-thick nickel mold can be heated from $25^{\circ}C\;to\;150^{\circ}C$ within 1.5 seconds with the temperature variation of ${\pm}5^{\circ}C$ in 4-inch diameter area, using the induction heating apparatus.

유전가열에 의한 고강도-저발포 스티로폼 개발 II (Development of low foamed-high strengthen styrofoam by dielectric heating II)

  • 한두희
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2001년도 춘계학술대회 발표논문집
    • /
    • pp.281-283
    • /
    • 2001
  • The low foamed high strengthen styrofoam samples made by dielectric heating are discussed. We used the oscillator which have the frequency of 13.6MHz and the Power of 7kW. 3 times expanded beads by steaming method were used in our foam-molding test. Internal fusion properties and density of internal structure were improved by dielectric foaming process. At the temperature of 105-110$^{\circ}C$, the internal fusion property was maximally improved.

펠티어 소자를 이용한 나노 사출 금형의 능동형 온도 제어 (A method for Thermal Control of Nano Injection Molding using the Peltier Devices)

  • 신홍규;권종태;홍남표;서영호;김병희
    • 소성∙가공
    • /
    • 제17권5호
    • /
    • pp.337-342
    • /
    • 2008
  • The injection molding process has high accuracy and good reproducibility that are essential for mass production at low cost. Conventional molding processes typically use the water-based mold heating and air cooling methods. However, in the nano injection molding processes, this semi-active mold temperature control results in the several defects such as air-flow mark, non-fill, sticking and tearing, etc. In order to actively control temperature of the molds and effectively improve the quality of the molded products, the novel nano injection molding system, which uses active heating and cooling method, has been introduced. By using the Peltier devices, the temperature of locally adiabatic molds can be controlled dramatically and the quality of the molded patterns can be improved.

도시가스 사용 주택의 동절기 실내온열환경 평가 (Evaluation of Indoor Thermal Environment of Houses using for heating in winter)

  • 박석봉;이현우
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.125-131
    • /
    • 2005
  • This study identified satisfaction with gas heating and indoor thermal environment, targeting houses using gases for heating. 1) Thermal environment is relatively satisfactory except that indoor humidity is low. 2) A question that indoor temperature has to be decreased for saving energy was given and about two thirds of the respondents answered that temperature has to be lowered. When they were asked how to save energy 57% answered that they put on more clothes and 27% answered that they lower indoor temperature If consistent promotion on energy saving is implementer it's believed that energy can be effectively saved. 3) People wear simple clothes when they stay indoor because they think it is comfortable. However, for energy saving. they gave to wear warm clothes though they stay indoor.

The Effect of Heat Curing Methods on the Protection against Frost Damage at Early Age of the Concrete Under Extremely Cold Climate

  • Jung, Eun-Bong;Shin, Hyun-Sup;Han, Min-Cheol
    • 한국건축시공학회지
    • /
    • 제13권6호
    • /
    • pp.513-521
    • /
    • 2013
  • This study aimed to examine whether heat curing methods of concrete subjected to $-10^{\circ}C$ could be effective by varying the combination of heating cable and surface heat insulations. Three different concrete specimens incorporating 30% fly ash with 50% W/B were fabricated to simulate wall, column and slab members with dimensions of $1600{\times}800{\times}200$ mm for slab, $800{\times}600{\times}200$ mm for wall and $800{\times}800{\times}800$ mm for column. For heat curing combinations, Type-1 specimens applied PE film for slab, plywood for wall and column curing. Type-2 specimens applied double layer bubble sheet (2LB) and heating coil for slab, and 50 mm styrofoam for wall and column curing. Type-3 specimen applied 2LB for slab, electrical heating mat for wall and column inside heating enclosure. The test results revealed that the temperature of Type 1 specimen dropped below $0^{\circ}C$ beginning at 48 hours after placement due to its poor heat insulating capability. Type 2 and 3 specimens maintained a temperature of around $5{\sim}10^{\circ}C$ after placement due to favorable heat insulating and thermal resistance.

Physiological Functionalities and Anti-oxidant activity of heated radish extract

  • Kim, Hyun-Kyoung
    • International journal of advanced smart convergence
    • /
    • 제7권2호
    • /
    • pp.38-46
    • /
    • 2018
  • This study proceeded an experiment that can increase such physiological properties of heated radish extract. During the extraction of radish, including the byproduct, an increase in antioxidant properties of radish according the heating temperature was performed. Upon the extracts of radish bark and radish green extract(mucheong), the physiological functionalities and antioxidant activity were investigated. As a result, the color of radish ethanol extract in dependence of heating temperature, showed light brown color at low heating temperature and black color from $150^{\circ}C$. The total polyphenol content significantly increased as a result of heat treatment; 6.7 times and 22 times higher than the control at $110^{\circ}C$ and $150^{\circ}C$, respectively. DPPH radical scavenging ability and antioxidant property increased with increasing heating temperature; in comparison to heat-treated radish at $110^{\circ}C$ and $150^{\circ}C$, $IC_{50}$ decreased by 1/22 times. $IC_{50}$ of the control was 23times higher than $150^{\circ}C$ heat treated radish (Control $IC_{50}$:130.305). According to the graph that represents ABTS activity, antioxidant activity increased in dependence of heat treatment likewise to the total polyphenol content and DDPH radical scavenging activity. Upon heat treatment at $150^{\circ}C$, antioxidant activity in consequence of ABTS assay increased 23 times higher than the control.

고분자전해질 연료전지의 중저온 열원을 건물난방에 이용하기 위한 온도 제어장치 개발 (Development of Temperature Control System to use in Building Heating of low Temperature Heat of PEMFC)

  • 차광석;김회서
    • 플랜트 저널
    • /
    • 제10권3호
    • /
    • pp.45-51
    • /
    • 2014
  • 본 연구에서는 기존 가정용연료전지에서 활용이 미약한 중저온의 배열을 건물난방부하에 적용할 수 있도록 온도 안정화 장치를 개발하였으며 이 장치가 기존 난방설비와 연계가 가능하도록 제어시스템을 구축하였다. 연료전지 시스템의 정상작동을 위해서는 연료전지로부터 배출되는 온수의 공급온도가 $60^{\circ}C$이어야 하고 다시 연료전지로 회수되는 작동 유체의 환수온도는 항상 $55^{\circ}C$로 유지하여야 한다. 본고에서는 먼저 스택배열 활용을 극대화하기 위해 CFD 분석을 통해 소형열교환기와 기존 난방설비배관과의 최적 연계장치시스템을 구성하였다. 또한 계절별 난방 수온의 불규칙한 온도변화에 대응하기 위해서 연료전지 스택의 열원과 아파트세대 난방용 환수관을 연결한 온도자동조절 밸브를 사용하여 온도안정화 장치를 개발하였다. 소형열교환기와 통합 활용할 수 있도록 설정된 온수의 온도가 편차 ${\pm}0.5^{\circ}C$ 이내에서 유지되도록 하였다. 이 연구결과를 통해 연료전지인 PEMFC의 배열을 건물난방부하에 활용이 추후 가능할 것으로 예상된다.

  • PDF

컨테이너하우스의 바닥과 벽면에 엑셀파이프 매설에 의한 벽면, 바닥, 공기, 온수의 온도분포 특성 (Characteristics of Temperature Distribution of Wall, Floor, Air and Hot Water by Burying the Excel Pipe on the Floor and Wall of a Container House)

  • 조동현
    • 한국기계가공학회지
    • /
    • 제21권2호
    • /
    • pp.94-100
    • /
    • 2022
  • A study was conducted to significantly increase the heat transfer area by simultaneously burying the excel pipe in the floor and wall of a container house, thereby greatly reducing the initial heating time. In addition, a small hot water boiler suitable for the heating load of a small container house with a maximum area of 6 m2 was studied. A wall-mounted hot water boiler was developed as a result of the study. When a hot water boiler is installed outdoors for heating, heat radiation energy is lost in winter from the hot water boiler and hot water pipe due to the low temperature. We propose an approach through which the energy loss was greatly reduced and the temperature of hot water increased in proportion to the operating time. Moreover, as the mass flow rate of the hot water flowing inside the excel pipe increased, the temperature of the hot water decreased. The temperature of the wall and floor surfaces of the container house increased in proportion to the increase in the mass flow rate of hot water flowing inside the excel tube. Natural convection heat transfer was realized from the wall and floor surfaces of the container house, and the heat transfer area was increased by a factor of 3 with respect to heat transfer area limited to the floor by the existing hot water panel. As a result, the initial temperature increase rate was much higher because of the larger heat transfer area.

Microwave Application in the Heating of Low-Loss Ceranmic Materials

  • Park, Seong-S.;Lee, Yoon-B.;Ryu, Su-C.;Jang, Youn-S.;Park, Hong-C.
    • 한국재료학회지
    • /
    • 제6권6호
    • /
    • pp.576-584
    • /
    • 1996
  • The zirconia-alumina composite, a low loss material, was sucessfully sintered using a 2.45 GHz microwave radiation. The dense zirconia was used as a microware coupling aid. The effect of microwave power level on the heating rates of samples and the feasibility of microwave energy use in processign ceramec materials were obtained. It was also obtained how to accurately measure the temperature. According to the microwave heating theory, heating mechanisms were discussed.

  • PDF