• Title/Summary/Keyword: low temperature curing

Search Result 310, Processing Time 0.036 seconds

The Effects of Curing Environment and Submerged Pump Pressure on the Strength of High-Strength Grout (양생환경 및 수중펌프압송이 고강도 그라우트의 강도에 미치는 영향)

  • Kim, Beom-Hwi;Son, Da-Som;Yi, Chong-Ku
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.191-192
    • /
    • 2023
  • In recent years, the use of high-strength grout has gained popularity in offshore wind power generation complexes for facility foundations and bridges. These marine wind farms require support for horizontal loads from wind and waves. To ensure the strength of the grout produced in environments similar to the actual placing site, this study investigated the curing of high-strength grout discharged through pump pressure in various environments, and examined the difference in strength according to different variables. Compressive strength measurements revealed that the core specimen collected from the bottom (3cm) and uppermost (50cm) of the specimen exhibited lower strength compared to other height specimens, while the core specimen obtained from the corner exhibited lower strength compared to the center. These findings suggest that the strength difference between the center and the corner is more pronounced when curing at low temperatures. This effect is greater than the strength reduction that typically occurs during low-temperature curing, and thus, necessitates careful attention in similar construction environments.

  • PDF

A Study on the Curing of Positive Plate and Grid to Improve the Capacity of the Lead-Acid Batteries (납축전지의 성능 향상을 위한 양극판의 숙성과 그리드에 관한 연구)

  • Ku, Bon-Keun;Jeong, Soon-Wook
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.41-47
    • /
    • 2008
  • This study was conducted to made a grid alloy (Pb-Ca-Sn-Al) which has a temporary composition ratio in order to improve the efficiency of lead acid batteries. The positive activity material made a 3BS(tri-basic lead sulfate; $3PbO{\cdot}PbSO_4{\cdot}H_2O$) by a low temperature curing and it evaluates the plate efficiency through the life cycle testing. The initial current capacity of low temperature curing plate was excellent but the life cycle was not good (S1). As for the S2 plate, however, the initial current capacity and the life cycle were superior.

Temperature Control of Mass-Concrete Structure with Pipe Cooling or Sheet Curing. (시트양생 및 파이프 쿨링에 의한 매스콘크리트 구조물의 온도제어)

  • 차홍윤;김은경;김래현;신치범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.263-267
    • /
    • 1995
  • The usual methods for the temperature control of mass-concrete structures include the use of low-heat cement, pre-cooling, post-cooling, or sheet curing. In order to control the heat of hydration during the construction of mass-concrete structures, the combination of the above methods is commonly employed. For the construction of mass-concrete structures such as massive pier or anchor, it is necessary to control the curing temperature with pipe cooling. In this study, the method of analysis on the effect of pipe of was proposed to prevent the thermal cracking due to heat of hydration In addition the effect of covering the concrete surface with blanket insulation was investigated. The results of the present study may be useful for the prediction of curing temperature of mass-concrete structures and the reasonable construction management.

  • PDF

Temperature Properties of Vertical Reinforcements in Wall Structures in Relation to the Different Methods of Bubble Sheet Installation in Winter (겨울철 버블시트 포설방법 변화에 따른 벽식구조 수직철근의 온도 특성)

  • Kim, Tae-Woo;Lee, Jea-Hyeon;Kyung, Yeong-Hyeok;Lee, Jong-Gyo;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.11-12
    • /
    • 2017
  • This study aims to analyze the properties of the temperature change in vertical reinforcements in outdoor wall structures in winter in relation to the different methods of bubble sheet installation, and to subsequently determine the possibility of initial frost damage to the concrete as a result of low temperature. As for the experimental variables, double bubble sheets were used as curing materials, and the curing method was to model the part where the slab and the wall intersect and the rebar is exposed, and to measure the change of temperature around the exposed rebar in accordance with the change of the coating curing. It was found that by employing curing method B, which is to install the bubble sheet between the vertical reinforcements, the most vulnerable area, which is 50mm below(④) the surface of the concrete, would be lowered to sub-zero temperature 20 hours later than when using curing method A, and that therefore it is more effective to install the bubble sheet between the vertical reinforcements for the prevention of initial frost damage.

  • PDF

Fundamental Properties of Alumina Cement Mortar by Insulation Curing Method under Low Temperature (저온환경에서 알루미나시멘트를 사용한 모르타르의 단열양생에 따른 기초물성 평가)

  • Park, Jung-Hoon;Ki, Kyoung-Kuk
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.5
    • /
    • pp.419-427
    • /
    • 2017
  • In order to examine the possibility of practical use of aluminate cement concrete at low-temperature environment with insulation method, an experimental studies on flowability, setting time, freezing temperature, size variation and compressive strength of the mortar at low-temperature were conducted. Compressive strength was increased in use of CSA, aluminate cement with gypsum. Workability and physical properties were improved by using aluminate cement and gypsum. In addition, freezing resistance and physical properties were improved by applying the insulation curing method. Especially, when alumina cement and gypsum were used together, the insulation curing method was more effective in improving the compressive strength.

The Effect of Heat Curing Methods on the Protection against Frost Damage at Early Age of the Concrete Under Extremely Cold Climate

  • Jung, Eun-Bong;Shin, Hyun-Sup;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.513-521
    • /
    • 2013
  • This study aimed to examine whether heat curing methods of concrete subjected to $-10^{\circ}C$ could be effective by varying the combination of heating cable and surface heat insulations. Three different concrete specimens incorporating 30% fly ash with 50% W/B were fabricated to simulate wall, column and slab members with dimensions of $1600{\times}800{\times}200$ mm for slab, $800{\times}600{\times}200$ mm for wall and $800{\times}800{\times}800$ mm for column. For heat curing combinations, Type-1 specimens applied PE film for slab, plywood for wall and column curing. Type-2 specimens applied double layer bubble sheet (2LB) and heating coil for slab, and 50 mm styrofoam for wall and column curing. Type-3 specimen applied 2LB for slab, electrical heating mat for wall and column inside heating enclosure. The test results revealed that the temperature of Type 1 specimen dropped below $0^{\circ}C$ beginning at 48 hours after placement due to its poor heat insulating capability. Type 2 and 3 specimens maintained a temperature of around $5{\sim}10^{\circ}C$ after placement due to favorable heat insulating and thermal resistance.

Effect of cyclic Change of Wet Bulb Temperature During Yellowing Stage on Chemical Properties of Flue-Cured Tobacco (황색종 cyclic 건조엽의 화학성분 특성)

  • Lee, Chul-Hwan;Jin, Jeong-Eui;Han, Chul-Soo
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.1
    • /
    • pp.19-25
    • /
    • 1998
  • The bulk curing experiment to the improve the quality of flue-cured leaves were carried out to evaluate relationship between cyclic curing and conventional curing method. We studied the effect of the cyclic change of wet bulb temperature at the yellowing stage of flue curing on chemical properties of cured leaves. The wet bulb temperature was automatically controlled between preset high($38^{\circ}C$) and low point ($35^{\circ}C$) everyone hour cyclically during 12 hours after starting luring. As a result, the acceleration of the increase in the chemical properties of cured leaves were observed. As to the chemical properties, there was decreased in citric acid, increased in malic acid of the nonvolatile organic acids and all higher fatty acids content of leaves cured by this method compared with in that of conventional curing method, while a major chemical compounds in relation to aromatic essence of cigarette smoke in essential oil components of lured leaves was mostly higher in this method than those of conventional ones, and it was evaluated that there was decreased in CO, TPM, Tar, and $CO_2$ content of the cigarette smoke comparing to the conventional luring method.

  • PDF

Field Application of Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather (이중버블시트를 이용한 단열양생공법의 한중콘크리트 현장적용)

  • Hong, Seak-Min;Lee, Il-Sun;Baek, Dae-Hyun;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.25-28
    • /
    • 2009
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in slab concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 5 and $l0^{\circ}C$ even in case outside temperature drops $-11^{\circ}C$ below zero until the 4nd day from piling. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

Effects of Weather Conditions on Sunburn in Stalk Curing of Burley Tobacco

  • Bae, Seong Kook;Jo, Chun Joon
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.22 no.2
    • /
    • pp.138-142
    • /
    • 2000
  • The effects of stalk cutting time and environmental factors such as air temperature, leaf temperature, solar radiation and leaf moisture content during harvesting and curing in burley tobacco(Nicotiana tabacum L.) on weight loss of fresh stalks and sunburning in leaves were investigated at Chonju Experiment Station, Korea Ginseng & Tobacco Research Institute in 1996 and 1997. Twelve to fifteen percent of the fresh weight was lost in 3 to 4 hours after stalk-cutting, and sunburned leaves could be observed in case of stalk cutting between 11:00 and 15:00 O'clock on a clear sunny day, when the air temperature was 34 to 35$^{\circ}C$, leaf temperature 52 to 54$^{\circ}C$, and solar radiation 700 to 940 w/$m^2$. The leaves exposed to this weather condition were sunburned within 1 hour after stalk cutting. But low temperature (below $25^{\circ}C$) with high solar radiation(above 700w/m2) or high temperature(above 3$0^{\circ}C$) with low solar radiation (below 600w$m^2$) did not induce the sunburn damage in leaves. As the leaf temperature and leaf moisture content were higher, the sunburned leaves increased. The leaves at the higher stalk position were more easily sunburned than those at the lower. This result indicates that the immature leaves with higher chlorophyll content might be more susceptible to sunburning.

  • PDF

Development of curing facility to improve environment for burley curing (I. Changes in microclimate during air-curing) (버어리종 잎담배 건조 환경 개선을 위한 건조실 개발 (I. 건조기간중의 미기상 변화))

  • Cha, Kwang-Ho;Jang, Soo-Won;Yang, Jin-Chul;Oh, Kyoung-Hwan;Shin, Seung-Ku;Jo, Chun-Joon
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.29 no.2
    • /
    • pp.66-73
    • /
    • 2007
  • This study was carried out to investigate the changes of curing condition on microclimate of temperature, relative humidity during curing process of burley tobacco leaves. The developed facility, ridge opening type was designed to open the central top roof. The air-cured variety, (N. tabacum cv KB111) was normally grown at the Eumseong tobacco experimental station in 2007. Mean daily temperature of $3^{\circ}C$ in ridge opening type curing facility was lower than that of conventional, whereas mean daily relative humidity of 12.6 % RH was lower in conventional curing facility for the entire stage of curing. The frequency distribution of optimal air temperature at daytime was higher 37.5 % in ridge opening type curing facility than that of conventional, while that of optimal relative humidity was lower 8.2 %. In the ridge opening type curing facility, the excessive drying leaves were low, however the price per kilogram was high. These results suggest that the new developed curing facility may be applied to improved microclimate inside the curing facility for curing burley.