Single Line-to-ground Fault Location and Information Modeling Based on the Interaction between Intelligent Distribution Equipment

  • Wang, Lei;Luo, Wei;Weng, Liangjie;Hu, Yongbo;Li, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1807-1813
    • /
    • 2018
  • In this paper, the fault line selection and location problems of single line-to-ground (SLG) fault in distribution network are addressed. Firstly, the adaptive filtering property for empirical mode decomposition is formulated. Then in view of the different characteristics showed by the intrinsic mode functions(IMF) under different fault inception angles obtained by empirical mode decomposition, the sign of peak value about the low-frequency IMF and the capacitance transient energy is chosen as the fault line selection criteria according to the different proportion occupied by the low-frequency components. Finally, the fault location is determined based upon the comparison result with adjacent fault passage indicators' (FPI) waveform on the strength of the interaction between the distribution terminal unit(DTU) and the FPI. Moreover, the logic nodes regarding to fault line selection and location are newly expanded according to IEC61850, which also provides reference to acquaint the DTU or FPI's function and monitoring. The simulation results validate the effectiveness of the proposed fault line selection and location methods.

Low Power Consumption Technology for Streaming Data Playback in the IPTV Set-top Box (IPTV 셋톱박스 환경에서 스트리밍 데이터 재생을 위한 전력 소모 감소 기법)

  • Go, Young-Wook;Yang, Jun-Sik;Kim, Deok-Hwan
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.1
    • /
    • pp.30-40
    • /
    • 2010
  • The hard disk is one of the most frequently used storage in IPTV sep-top box. It has large storage capacity and provides fast I/O speed compared to its price whereas it causes high power consumption due to mechanical characteristics of spindle motor. In order to play streaming data in the set-top box, spindle motor of hard disk keeps active mode and it causes high power consumption. In this paper, We propose an offset-buffering and multi-mode spin-down method to reduce power consumption for streaming data playback. The offset-buffering inspects the user's viewing pattern and performs buffering based on the analysis of viewing pattern. So, it can maintain the status of spindle motor as idle mode for long time. Besides, it can reduce power consumption by spinning down according to offset-buffer size. The experimental result shows that proposed offset-buffering and multi mode spin-down method is about 28.3% and 12.5% lower than the full-Buffering method in terms of the power consumption and spin-down frequency, respectively.

A Low Power Current-Mode 12-bit ADC using 4-bit ADC in cascade structure (4비트 ADC 반복구조를 이용한 저전력 전류모드 12비트 ADC)

  • Park, So-Youn;Kim, Hyung-Min;Lee, Daniel-Juhun;Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1145-1152
    • /
    • 2019
  • In this paper, a low power current mode 12-bit ADC(: Analog to Digital Converter) is proposed to mix digital circuits and analog circuits with the advantages of low power consumption and high speed operation. The proposed 12 bit ADC is implemented by using 4-bit ADC in a cascade structure, so its power consumption can be reduced, and the chip area can be reduced by using a conversion current mirror circuit. The proposed 12-bit ADC is SK Hynix 350nm process, and post-layout simulation is performed using Cadence MMSIM. It operates at a supply voltage of 3.3V and the area of the proposed circuit is 318㎛ x 514㎛. In addition, the ADC shows the possibility of operating with low power consumption of 3.4mW average power consumption in this paper.

Analysis of the Factors Affecting Low-Frequency Oscillations in KEPCO Power System` With Pumped-Storage Plant (한전 전력계통의 저주파 진동현상 요인분석;양수발전기 기동시)

  • Kil Yeong Song;Sae Hyuk Kwon;Kyu Min Ro;Seok Ha Song
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.8
    • /
    • pp.841-849
    • /
    • 1992
  • In power system operation, the stability of synchronous machine has been recognized one of the most important things. AESOPS program developed by EPRI in U.S.A. is a frequency domain analysis program in power system stability and it computes the electro-mechanical oscillation mode. This paper presents how to analyze the power system small signal stability problem efficiently by uusing the AESOPS program and analyze the various factors affecting the damping characteristics of these oscillations in KEPCO power system of 1986 with pumped-storage plant. To reduce the computing time and efforts, selecting the poorly-damped oscillation mode and clustering technique have been used. The characteristics of load, the amount of power flow on the transmission line and the gain of exciter have a significant effects on the damping of the system while the governing system has only a minor one. With the Power System Stabilizers, the stability of the power system has been improved.

  • PDF

Design of a Current-Mode Analog Filter for WCDMA Baseband Block (WCDMA 베이스밴드단 전류모드 아날로그 필터 설계)

  • Kim, Byoung-Wook;Bang, Jun-Ho;Cho, Seong-Ik;Choi, Seok-Woo;Kim, Dong-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.255-259
    • /
    • 2008
  • In this paper, a current-mode integrator for low-voltage, low-power analog integrated circuits is presented. Using the proposed current-mode integrator, the baseband analog filter is designed for WCDMA wireless communication. To verify the proposed current-mode integrator circuit, Hspice simulation using 1.8V TSMC $0.18{\mu}m$ CMOS parameter is performed and achieved 44.9dB gain, 15.7MHz unity gain frequency. The described 3rd-order current-mode baseband analog filter is composed of the proposed current-mode integrator, and SFG(Signal Flow Graph) method is used to realize the baseband filter. The simulated results show 2.12MHz cutoff frequency which is suitable for WCDMA baseband block.

A 2-Gb/s SLVS Transmitter for MIPI D-PHY (MIPI D-PHY를 위한 2-Gb/s SLVS 송신단)

  • Baek, Seung Wuk;Jeong, Dong Gil;Park, Sang Min;Hwang, Yu Jeong;Jang, Young Chan
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.25-32
    • /
    • 2013
  • A 1.8V 2-Gb/s scalable low voltage signaling (SLVS) transmitter (TX) is designed for mobile applications requiring high speed and low power consumption. It consists of 4-lane TX for data transmission, 1-lane TX for a source synchronous clocking, and a 8-phase clock generator. The proposed SLVS TX has the scaling voltage swing from 50 mV to 650 mV and supports a high speed (HS) mode and a low power (LP) mode. An output impedance calibration scheme for the SVLS TX is proposed to improve the signal integrity. The proposed SLVS TX is implemented by using a 0.18-${\mu}m$ 1-poly 6-metal CMOS with a 1.8 V supply. The simulated data jitter of the implemented SLVS TX is about 8.04 ps at the data rate of 2-Gb/s. The area and power consumption of the 1-lane of the proposed SLVS TX are $422{\times}474{\mu}m^2$ and 5.35 mW/Gb/s, respectively.

Mppt control of PMSG wInd power system using adaptive sliding mode control (적응 슬라이딩 모드제어를 통한 PMSG 풍력발전시스템의 MPPT제어)

  • Jeong, Hyeong-Cheol;Chun, Kwan-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1060-1061
    • /
    • 2015
  • This paper presents the control method of MPPT (Maximum Power Point Tracking) using back-to- back converter. The windturbine system use PMSG(ermanent Magnet Synchronous Generator) system considering low maintenance costs and driving performance at low wind. This paper use the adaptive sliding mode control to the torque control. Proposed method was analyzed mathematically.

  • PDF

Polar Transmitter with Differential DSM Phase and Digital PWM Envelope

  • Zhou, Bo;Liu, Shuli
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.3
    • /
    • pp.313-321
    • /
    • 2014
  • A low-power low-cost polar transmitter for EDGE is designed in $0.18{\mu}m$ CMOS. A differential delta-sigma modulator (DSM) tunes a three-terminal voltage-controlled oscillator (VCO) to perform RF phase modulation, where the VCO tuning curve is digitally pre-compensated for high linearity and the carrier frequency is calibrated by a dual-mode low-power frequency-locked loop (FLL). A digital intermediate-frequency (IF) pulse-width5 modulator (PWM) drives a complementary power-switch followed by an LC filter to achieve envelope modulation with high efficiency. The proposed transmitter with 9mW power dissipation relaxes the time alignment between the phase and envelope modulations, and achieves an error vector magnitude (EVM) of 4% and phase noise of -123dBc/Hz at 400kHz offset frequency.

Vibration Control of Engine Body for Two Stroke Low Speed Diesel Engine using Dynamic Vibration Absorber (동흡진기에 의한 저속 2행정 디젤엔진의 본체진동 제어)

  • 이돈출;유정대;김정렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.631-637
    • /
    • 2002
  • Two stroke low speed diesel engines are used as a power supplier not only for marine vessel but also diesel power plant with a benefit of its higher mobility and durability than the other thermal engines. However, there are some disadvantages such as the bigger vibrating excitation forces generated by high combustion pressure in cylinders which various kinds of vibrations are caused. In this paper, it is theoretically studied to control engine body vibration using dynamic vibration absorber. As an actual case, dynamic absorbers are designed for controlling X-mode vibration of 9K80MC-S engine on the diesel power plant and its performance is identified by the vibration test both in shop and site

Droop Control for Parallel Inverers in Islanded Microgrid Considering Unbalanced Low-Voltage Line Impedances (마이크로그리드 독립 운전 모드시 저전압 불평형 선로 임피던스를 고려한 드룹 방식의 인버터 병렬 운전 제어 연구)

  • Lim, Kyung-Bae;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.387-396
    • /
    • 2013
  • This paper investigates the droop control of parallel inverters for an islanded mode of microgrid. Frequency and voltage droop control is one of power control and load demand sharing methods. However, although the active power is properly shared, the reactive power sharing is inaccurate with conventional method due to the unequal line impedances and the power coupling of active - reactive power. In order to solve this problem, an improved droop method with virtual inductor concept and a voltage and current controller properly designed have been considered and analyzed through the PSiM simulation. The performance of improved droop method is analyzed in not only low-voltage line but also medium voltage line.