• 제목/요약/키워드: low point

검색결과 5,328건 처리시간 0.033초

Possibility of Obtaining Lubricant Base Oil from Talakan Crude Oil Suitable for Exploitation in Extremely Cold Conditions in the Republic of Sakha (Yakutia)

  • Zhirkov, N.P.;Zakharova, S.S.;Sung, Zoo-One
    • Tribology and Lubricants
    • /
    • 제31권1호
    • /
    • pp.28-34
    • /
    • 2015
  • This paper addresses the problems of using anti-freeze lubricants for different machines that must function at extremely low temperatures during winter operation in the Republic of Sakha (Yakutia). We discuss the possibility of obtaining anti-freeze base oils from Talakan crude oil, an area with major oil and gas deposits of the Republic of Sakha, and also provide the trade and technological classification of Talakan crude oil. We propose two different schemes for processing Talakan crude oil: the fuel scheme (obtaining light and heavy fractions as a fuel oil) and the base oil scheme (obtaining light fractions and base oils). We investigate the influence of pour point depressants on alkyl-methacrylate base on the low-temperature properties of the fractions obtained from Talakan crude oil and Korean base oils, and establish the optimal concentration of pour point depressants. We compare the properties of these fractions with the low-temperature properties of Korean base oils and find that the commercial oil "Ravenol 0W-40" provides optimistic results. We obtain oil with a pour point of minus $50^{\circ}C$ and a viscosity index greater than 100. The Design of Experiment was used to establish the optimum composition of the pour point depressants and the base oil S-8 to obtain lubricant oil with a kinematic viscosity of 17 cSt, viscosity index of 208, and a pour point of minus $64^{\circ}C$.

저탄소강판을 이용한 굽힘 가공에서 발생하는 꺾임 현상에 대한 발생기구 해석 (Analysis on the Mechanism of Fluting in the Bending of Low Carbon Steels)

  • 박기철;윤정봉
    • 소성∙가공
    • /
    • 제16권4호
    • /
    • pp.317-322
    • /
    • 2007
  • In order to investigate the cause and condition of fluting in tangential bending of low carbon steel sheet, an analytic analysis, an experiment and a series of finite element analysis for bending process were done. The fluting in bended sheet was related with the yield point elongation of material. Due to the yield point elongation, unstable plastic hinge was occurred in course of bending of elastic perfectly plastic sheet. According to the analysis and computational results, lower yield point elongation than 5% was required to prevent fluting in 0.5-0.6t sheet in $15{\sim}25mm$ radius bending. The tendency of fluting occurrence was reduced as decreasing the radius of bending, increasing thickness of bended sheet, and removing irregularity in sheet and bending processes.

프릿트 첨가에 따른 저온소성 기판과 Cu와의 접합 거동에 관한 연구 (The Effect of Frit on Bonding Behavior of Low-firing-substate and Cu Conductor)

  • 박정현;이상진
    • 한국세라믹학회지
    • /
    • 제32권5호
    • /
    • pp.601-607
    • /
    • 1995
  • The bond strength between the low-firing-substrate and Cu conductor depended on the softening point and the amount of frit added to the metal paste. The addition of 3 wt% frit (softening point: 68$0^{\circ}C$) to the metal paste resulted in the improvement of bond strength, which was approximately 3 times higher (3kg/$\textrm{mm}^2$) than that of non frit condition. It was also found that fracture surface shifted to the ceramic substrate in the interface region. These phenomena were attributed to the frit migration into the metal-ceramic interface. It was thought that the migration of glass frit occurred extensively when the softening point of glass firt was 68$0^{\circ}C$. The sheet resistance of Cu conductor remained constant by the addition of 4 wt% frit regardless of softening point of frit. For all samples with more than 4 wt% frit, the sheet resistance increased abruptly.

  • PDF

In 계 저융점합금의 닥터 블레이드 테이프캐스팅 (Doctor Blade Tape Casting of In-based Low Melting Point Alloy)

  • 윤기병
    • 한국주조공학회지
    • /
    • 제35권3호
    • /
    • pp.62-66
    • /
    • 2015
  • Tape casting is an important forming operation used to prepare flat sheets in the various industries. In this study, Doctor Blade tape casting of In-based low melting point alloy was carried out. The purpose of this investigation was to determine the possibility of applying the Doctor Blade tape casting process to the manufacture of low melting point alloy sheets that can be used as thermal fusible parts of battery safety systems. In-based molten alloy that has a melting point of $95^{\circ}C$ was produced; it's viscosity was measured at various temperatures. The molten alloy was used as a slip in the caster of the Doctor Blade tape casting system. The effects of the molten alloy temperatures and carrier speeds on the produced sheet shape were observed. For the casting conditions of 1.5 cm slip height, $120^{\circ}C$ slip temperature, 0.05 mm blade gap and 60 m/min. carrier speed, an In-based alloy thin tape well shaped with 0.16 mm uniform thickness was continuously produced.

우리 나라 노인의 영양부족위험 진단을 위해 개발된 간이조사표의 타당성 평가 (Evaluation of the Validity of a Simple Screening Test Developed for Identifying Korean Elderly at Risk of Undernutrition)

  • 이정원;김경은;김기남;현태선;현화진;박영숙
    • Journal of Nutrition and Health
    • /
    • 제33권8호
    • /
    • pp.864-872
    • /
    • 2000
  • This study intended to evaluate the validity of the simple nutrition screening test that had been developed with the elderly living in Cheongju as a subject. Nutrition screening score(NSS) and reference standards for nutritional and health status(nutrient intakes, mean adequacy ratio, perceive health, and serum albumin, hematocrit, and hemoglobin) were estimated by using the date obtained in 1996 from the 174 elderly living in Taejon, Statistical analysis showed significant correlations between mean adequacy ratio(MAR) and NSS(r=0.341) and also between NSS and biological indices such as albumin and hematocrit, Around 65-75% of the elderly with perceive health and low level of serum albumin, hemoglobin and hematocrit had NSS$\leq$ll. Sensitivity, specificity, and positive predictive values(PPV) were calculated from the crosstabulation of the three categories of NSS(high, moderate, and low nutritional risk) and low categories MAR(< 0.75, undernutrition;$\geq$0.75, normal) to validate the cut-off point for high or low nutritional risk by NSS. It was suggested that point l1 was appropriate as a criterion to determine high risk of undernutrition, but point 16 was better than 17 as criterion to determine low nutritional risk in the Taejon elderly. When point ll was used as a criterion of high nutritional risk, sensitivity, specificity, and PPV are 59.5, 60.5 and 82.1 respectively. When point 16 was used as a criterion of low nutritional risk, sensitivity, specificity, and PPV are 25.6, 95.4, and 64.7%, respectively. In conclusion, nutrition screening test that had been developed can be a simple, easy, and proper instrument to classify the high risk group of undernutrition. A further validation study seems to be required among other groups of individuals for the screening test to the finalized as a more valid instrument identifying Korean elderly at nutrition and health risk(Korean J Nutrition 33(8) : 864-872, 2000)

  • PDF

MIMO-OFDM 시스템을 위한 고속 저면적 128/64-point $Radix-2^4$ FFT 프로세서 설계 (A High-Speed Low-Complexity 128/64-point $Radix-2^4$ FFT Processor for MIMO-OFDM Systems)

  • 리우 항;이한호
    • 대한전자공학회논문지SD
    • /
    • 제46권2호
    • /
    • pp.15-23
    • /
    • 2009
  • 본 논문은 높은 데이터 처리율을 요하는 MIMO-OFDM 시스템을 위하여 고속의 낮은 하드웨어 복잡도를 가진 128/64-point $radix-2^4$ FFT/IFFT 프로세서 설계에 대해 제안한다. 높은 Radix 다중경로 지연 피드백 (MDF) FFT구조는 고속의 데이터 처리율과 낮은 하드웨어 복잡도를 제공한다. 제안하는 프로세서는 128-point와 64 Point FFT/IFFT의 동작을 지원할 뿐만 아니라 4-병렬 데이터 경로를 사용함으로써 높은 데이터 처리율을 지원한다. 또한, 제안하는 프로세서는 기존의 128/64-point FFT/IFFT 프로세서에 비해 낮은 하드웨어 복잡도를 지닌다. 제안된 FFT/IFFT 프로세서는 IEEE 802.11n 표준의 요구사항을 만족시키며 140MHz 클락 속도에서 560MSample/s의 높은 데이터 처리율을 가진다.

효율적인 부분곱의 재배치를 통한 고속 병렬 Floating-Point 고속연산기의 설계 (Design of Fast Parallel Floating-Point Multiplier using Partial Product Re-arrangement Technique)

  • 김동순;김도경;이성철;김진태;최종찬
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.47-50
    • /
    • 2001
  • Nowadays ARM7 core is used in many fields such as PDA systems because of the low power and low cost. It is a general-purpose processor, designed for both efficient digital signal processing and controller operations. But the advent of the wireless communication creates a need for high computational performance for signal processing. And then This paper has been designed a floating-point multiplier compatible to IEEE-754 single precision format for ARMTTDMI performance improvement.

  • PDF

저영향개발(LID)을 적용한 토지이용계획 기법 개발 및 적용효과 분석 : 세종시 6생활권을 대상으로 (The development of land use planning technique applying low impact development and verifying the effects of non-point pollution reduction : a case study of Sejong city 6 district)

  • 강기훈;이경환
    • 한국산학기술학회논문지
    • /
    • 제18권7호
    • /
    • pp.548-553
    • /
    • 2017
  • 우리나라의 급속한 산업화는 도시침수, 하천 건천화, 지하수 고갈, 수질오염 등의 많은 문제를 야기하였으며, 최근 이에 대한 대안으로 저영향개발 기법이 제시되고 있다. 저영향개발 기법은 도시의 불투수 면적을 줄이고 녹지면적을 확보하여 자연 상태의 물순환체계를 구축하기 위한 도시개발 기법이다. 이에 본 연구는 토지이용계획 단계에서 적용가능한 저영향 개발 설계기술을 개발하고 비점오염 저감효과를 정량적으로 검증하는데 목적을 두고 연구를 진행하였으며 구체적으로는 토지이용계획 단계에서 적용가능한 저영향개발 설계요소를 도출하고 실제 대상지에 적용, 비점오염 저감효과를 LIDMOD2 프로그램을 이용하여 분석하였다. 분석결과 기존 토지이용계획안에 비해 저영향개발을 적용한 토지이용계획안의 경우 불투수율과 연간 표면 유출량은 각각 19.8%, 19.0% 감소하고, 연간 침투량은 164.1% 증가하는 것으로 나타났다. 비점오염 발생량의 경우 T-N, T-P, BOD 모두 18.7~22.8% 감소하는 것으로 나타났다. 따라서 저영향개발을 적용한 토지이용계획안은 기존 토지 이용계획안에 비해 각 용도별 연면적 변화 없이도 비점오염 저감효과가 상당히 큰 것으로 판단된다. 따라서 비점오염 저감효과를 극대화하기 위해서는 기존 LID시설 위주의 계획에서 나아가 토지이용계획 단계에서부터 저영향 개발기법을 적용하여 관련 계획을 수립할 필요가 있다.

Flexural performance of double skin composite beams at the Arctic low temperature

  • Yan, Jia-Bao;Dong, Xin;Wang, Tao
    • Steel and Composite Structures
    • /
    • 제37권4호
    • /
    • pp.431-446
    • /
    • 2020
  • This paper presents the flexural performance of double skin composite beams (DSCBs) at different Arctic low temperatures. 12 DSCBs were prepared and tested under two-point loading at different Arctic low temperatures of 20, -30, -50, and -70℃. The studied parameters include low-temperature level (T), steel-faceplate thickness (t), shear span ratio (λ), and spacing of headed studs (S). The experimental investigations under two-point loading tests showed that flexural failure occurred to all DSCBs, even including the specimen designed with the small λ ratio of 2.9. The ultimate strength behaviours of DSCBs were improved due to the improved mechanical properties of constructional materials and the confinement on shear connectors. The DSCB subjected to two-point loading and low temperatures exhibits a five-stage working mechanism. The stiffness and strength indexes of DSCBs increase linearly with temperature and t value increasing, while decreasing as shear span ratio boosts. In the contrast, the change of S value from 150 to 200 mm has little effect on the ultimate strength behavior of DSCB.

은침점전기자극의 인체적용이 신사구체여과율(Glomerular Filtration Rate)에 미치는 효과 (Effects of Silver Spike Point Electrical Stimulation on Glomerular Filtration Rate in Volunteer)

  • 천기영;김순희;민경옥;최영덕;이준희;김중환
    • 대한물리치료과학회지
    • /
    • 제11권1호
    • /
    • pp.28-35
    • /
    • 2004
  • The purpose of the present study was to investigate the effectiveness of silver spike point (SSP) low frequency electrical stimulation on glomerular filtration rate (GFR), specifically, such as diuretic action in 24 hour urine and in plasma analysis from normal volunteer. The current of 1 Hz continue type (CT) of SSP low frequency electrical stimulation significantly decreased in plasma creatine from normal volunteer. However, the urine creatinine clearance (Ccr) was significantly increased by SSP low frequency electrical stimulation in normal volunteer. These results suggest that the SSP low frequency electrical stimulation, especially current of 1 Hz continue type, significantly regulates urine creatinine clearance and glomerular filtration rate from normal volunteer. Therefore, the SSP low frequency electrical stimulation is a good regulator through a diuretic action of hypertension.

  • PDF