• Title/Summary/Keyword: low oxygen treatment

Search Result 418, Processing Time 0.029 seconds

Effects of Zn Coating and Heat Treatment on the Corrosion of Aluminum Heat Exchanger Tubes (아연 코팅과 열처리에 따른 알루미늄 열교환기 소재의 부식)

  • Cho, Soo Yeon;Kim, Jae Jung;Jang, Hee Jin
    • Corrosion Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.24-32
    • /
    • 2019
  • The effects of zinc coating and heat treatment on the corrosion resistance of aluminum alloys including A1100 and the modified A3003, used as heat exchanger tube were investigated in this study. The grain size of the heat-treated specimen is larger than that of the specimen without heat treatment, but the grain size did not significantly affect the corrosion behavior. The concentration of zinc was noted at 11.3 ~ 31.4 at.% for the as-received Zn-coated samples and reduced to 1.2 ~ 2.4 at.% after the heat treatment, as measured by the scanning electron microscopy (SEM) with an energy dispersive spectrometer (EDS) on the surface. The concentration of oxygen is 22 ~ 46 at.% for the zinc coated specimens while noted at 7.4 ~ 12.8 at.% for the specimens after the removal of the coating. The corrosion behavior depended largely on the concentrations of zinc, aluminum, and oxygen on the specimen surface, but not on the Mo content. The corrosion potential was high and the corrosion rate was low for a specimen with a low zinc content, a high aluminum content, and a high oxygen content.

The Study of Biofouling Control and Cause Material in Hybrid Process of Pure Oxygen and Submerged Membrane Bio-reactor (순산소 고율포기시스템 및 침지식 MBR융합공정에서 Biofouling 제어 및 원인물질 규명에 관한 연구)

  • Lee, Sang-Min;Kim, Mi-Hyung
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.44-53
    • /
    • 2011
  • Membrane bio-reactor (MBR) has several advantages over the conventional activated sludge process, including a high biomass, low sludge production, and better permeate quality. Therefore, the MBR have gained popularity for municipal and industrial wastewater treatment. However the MBR usually were used for sewage and low streng th wastewater treatment because of membrane fouling problem and limitation of oxygen transfer into biomass. In this study, the hybrid process combining MBR and pure oxygen was tested for high strength organic wastewater treatment in the COD loading range from 2 to $10kgCOD/m^3{\cdot}day$. The hybrid process, membrane coupled pure oxygen high compact reactor (MPHCR), had been operated for one year and operation parameters, the effect of COD loading, MLSS concentration and the location of membrane module were studied for membrane fouling characteristic. Also membrane resistance test and the component of foulant was analyzed to investigate what is specific foulant in the MBR.

Automatic Control of Fraction of Inspired Oxygen in Neonatal Oxygen Therapy using Fuzzy Logic Control

  • Chanyagorn, Pornchai;Kiratiwudhikul, Phattaradanai
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.2
    • /
    • pp.107-116
    • /
    • 2016
  • Premature babies of less than 37 weeks gestation might require oxygen therapy as an integral part of treatment and respiratory support. Because of their under-developed lungs, these so-called "preemies" might contract respiratory distress syndrome (RDS). To treat RDS, neonatal oxygen therapy is administered, where controlled oxygen gas is measured as a fraction of inspired oxygen ($FiO_2$). However, exposure to high oxygen content during long treatment could cause oxygen intoxication, which might cause permanent blindness due to retinopathy of prematurity (ROP), whereas insufficient oxygen exposure could cause severe hypoxia. A doctor would use oxygen saturation ($SpO_2$) data and prescribe a dose of $FiO_2$ to maintain $SpO_2$ within a suitable range. One objective is to maintain $SpO_2$ within the acceptable range using $FiO_2$ that is as low as possible. Adjustment of $FiO_2$ would normally be done by nurses every 15 to 30 minutes, which might not be safe in many situations. An error in $FiO_2$ adjustment during a manual procedure could be as large as +/- 2.5%. This paper presents a system that can determine an $FiO_2$ value suitable to the current $SpO_2$ and that automatically adjusts $FiO_2$ with an error clearance of +/- 0.25%.

Hydrogen Adsorption of Acid-treated Multi-walled Carbon Nanotubes at Low Temperature

  • Lee, Seul-Yi;Park, Soo-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.6
    • /
    • pp.1596-1600
    • /
    • 2010
  • Surface functionalization of multi-walled carbon nanotubes (MWNTs) was carried out by means of acid treatment. The presence of oxygen functional groups on the surface of acid-treated MWNTs was confirmed with the aid of Fourier transform infrared spectroscopy and X-ray spectroscopy. In addition, carboxylic groups generally formed on the surface of acid-treated MWNTs, and the dispersion was increased by the duration of the acid treatment. The zeta-potential indicated the surface charge transfer and the dispersion of MWMTs. Morphological characteristics of acid-treated MWNTs were also observed using a transmission electron microscopy, X-ray diffraction, and Raman analysis, which was revealed the significantly unchanged morphologies of MWNTs by acid treatment. The hydrogen adsorption capacity of the MWNTs was evaluated by means of adsorption isotherms at 77 K/1 atm. The hydrogen storage capacity was dependent upon the acid treatment conditions and the formation of oxygen functional groups on the MWNT surfaces. The latter have an important effect on the hydrogen storage capacity.

Surface Treatment of Polymer Materials and Transparent Conductive Films

  • Lee, Bong-Ju;Lee, Kyung-Sup
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.4
    • /
    • pp.7-10
    • /
    • 2001
  • A new possibility of our atmospheric cold plasma torch has been examined on the surface treatment of an air-exposed vulcanized rubber compound. The plasma treatment effect was evaluated by the bondability with another rubber compound using a polyurethane adhesive. The adhesion property was improved by the treatment with plasma containing oxygen radicals. The oxygen radical generation from the plasma was verified and its efficiency was found to be dependent on the cathode material.

  • PDF

Characteristics of Sludge Bulking Caused by Low Dissolved Oxygen in Aeration Tank for Paper Mill Wastewater Treatment (포기조의 낮은 용존산소로 인한 제지폐수의 슬러지 팽화특성)

  • Kwak, Dong-Heui;Yoo, Seung-Joon;Park, Jong-Chun
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.458-464
    • /
    • 2008
  • Bulking phenomena and scum formation are common problem in suspended growth system like the activated sludge plants for wastewater treatment. Apart from wastewater composition, operating conditions, such as mechanical stress by insufficient oxygen supply, are often decisive for the occurrence of a bulking or scumming problem. There were the comparative aeration tanks in terms of sludge bulking caused by the difference of mechanical aeration facilities in the wastewater treatment plant of N paper mill company. In this study the cause of bulking was investigated through not only the biological isolation and identification but also a series of operational data consideration. On the basis of the investigation results for bulking cause, the operational criteria on dissolved oxygen concentration was derived to decrease the bulking problem.

Reduction of the Flow Accelerated Corrosion within Low Pressure Evaporator Connection Pipe by Interception of Hydrazine for Water Treatment (탈산소제 차단 수처리에 의한 배열회수보일러 저압증기발생기 연결배관내의 유동가속부식 저감)

  • Son, Byung-Gwan;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.9 no.4
    • /
    • pp.26-30
    • /
    • 2013
  • Based on case that HRSG low pressure steam generator tube was damaged by FAC in 500 MW A CCPP. This case analyzed the effect of application about the block of hydrazine water treatment which is applied for increasing dissolved oxygen. And also try to deduce the major factor of FAC Which is caused by lacking of dissolved oxygen of boiler feed system. After 1 year of water treatment, the figure of dissolved oxygen in the boiler feed water has increased from 0.15 ppb to 3~5 ppb and the figure of oxidation reduction potential has increased from -245 mV to 170 mV. And Iron content, the corrosion products by FAC has decreased from 18.5 ppb to 5~7 ppb. According to the result of experiment, we could able to confirm that the interception of hydrazine of water treatment is effective to reduce FAC.

  • PDF

Effect of Plasma Treatment on TiO2/TiO2-x Resistance Random Access Memory (플라즈마 표면처리가 TiO2/TiO2-x 저항 변화형 메모리에 미치는 영향)

  • Kim, Han-Sang;Kim, Sung-Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.6
    • /
    • pp.454-459
    • /
    • 2020
  • In this study, a TiO2/TiO2-x-based resistance variable memory was fabricated using a DC/RF magnetron sputtering system and ALD. In order to analyze the effect of oxygen plasma treatment on the performance of resistance random access memory (ReRAM), the TiO2/TiO2-x-based ReRAM was evaluated by applying RF power to the TiO2-x oxygen-holding layer at 30, 60, 90, 120, and 150 W, respectively. The ReRAM was fabricated, and the electrical and surface area performances were compared and analyzed. In the case of ReRAM without oxygen plasma treatment, the I-V curve had a hysteresis curve shape, but the width was very small, with a relatively high surface roughness of the oxygen-retaining layer. However, in the case of oxygen plasma treatment, the HRS/LRS ratio for the I-V curve improved as the applied RF power increased; stable improvement was also noted in the surface roughness of the oxygen-retaining layer. It was confirmed that the low voltage drive was not smooth due to charge trapping in the oxygen diffusion barrier layer owing to the high intensity ReRAM applied with an RF power of approximately 150 W.

Optical Spectroscopic Analysis of Muscle Spasticity for Low-Level Laser Therapy (LLLT)

  • Lee, Yeon-Ui;Lee, Sang-Kwan;Youn, Jong-In
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.373-379
    • /
    • 2011
  • Current therapeutic methods for suppressing muscle spasticity are intensive functional training, surgery, or pharmacological interventions. However, these methods have not been fully supported by confirmed efficacy due to the aggravation of the muscle spasticity in some patients. In this study, a combined system was developed to treat with a low-level laser and to monitor the region of the treatment using an optical spectroscopic probe that measures oxygen saturation and deoxygenation during low-level laser therapy (LLLT). The evaluation of the wavelength dependence for LLLT was performed using a Monte Carlo simulation and the results showed that the greatest amount of heat generation was seen in the deep tissue at ${\lambda}$ = 830 nm. In the oxy- and deoxygenation measurements during and after the treatment, oxygen-Hb concentration was significantly increased in the laser-irradiated group when compared to the control group. These findings suggest that LLLT using ${\lambda}$ = 830 nm may be of benefit in accelerating recovery of muscle spasticity. The combined system that we have developed can monitor the physiological condition of muscle spasticity during the laser treatment in real time and may also be applied to various myotonia conditions such as muscle fatigue, back-pain treatment/monitoring, and ulcer due to paralysis.

Removal of Contaminants Deposited on Surfaces of Matrices by Using Low-Temperature Argon Plasma Treatment (저온 아르곤 플라즈마처리를 이용한 모재 표면의 오염물 제거)

  • Seo, Eun-Deock
    • Journal of Conservation Science
    • /
    • v.30 no.3
    • /
    • pp.299-306
    • /
    • 2014
  • The possibility of a low-temperature argon plasma treatment as a mean of restoration technology for contaminated invaluable archive materials and artefacts, and evidencing documents was investigated along with an oxygen plasma treatment for comparison. For this purpose, the degree of color changes, ${\Delta}E^*ab$, and surface morphological changes due to plasma treatments as an evaluation of removal performance of artificial contaminants such as brilliant green dye and carbon deposit on cellulose acetate and plain paper as matrices, respectively, were measured and analyzed using a spectrophotometer and a field emission scanning electron microscope. Compared to the argon plasma treatment with sputtering characteristic, that of the oxygen plasma with characteristic of an oxidation reaction has shown superior results in removing the contaminants; the oxygen plasma has proven to damage the matrices significantly due to its oxidative characteristic, and post-plasma reactions has anticipated to be also detrimental to the surfaces, whereas, the problems caused by the counterpart has resulted in being negligible and rather has thought to be an appropriate mean for delicate restoration and/or removal operations of contaminants.