• Title/Summary/Keyword: low loss

Search Result 5,066, Processing Time 0.054 seconds

A study on dielectric loss tangent measurement with $Al_{2}O_{3}$ crystal ($Al_{2}O_{3}$ crystal의 유전손실계수 측정에 관한 연구)

  • Lee, Jong-Chan;Lin, Yea-Hoon;Lee, Rae-Duk;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1466-1468
    • /
    • 1996
  • The standards of the capacitance arc measured and analyzed by the dry nitrogen or mica film as a dielectric. In this paper, respectively the standard capacitors of 10 pF and 100 pF for the establishment of the dielectric loss tangent are made by $Al_{2}O_{3}$ crystal disc with the low dielectric loss tangent, and then measured the dielectric loss tangent with precision. To regard for the existence of capacitances just in the dielectric, 3-terminal configuration electrode is used. With using the 2D electric field simulator, precise design values are derived in addition to stray capacitance. As stated above method, respectively the standards of the capacitances with 10 pF and 100 pF arc made with the low dielectric loss tangent less than $10^{-4}$.

  • PDF

Synthesis and Characterization of Fluorinated Poly(phenylmaleimide-co-pentafluorophenylmaleimide) for Optical Waveguides

  • Choi, Jongwan;Oh, Jin-Woo;Kim, Nakjoong
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.4
    • /
    • pp.1077-1080
    • /
    • 2013
  • Fluorinated polymaleimides with high thermal stability and low optical absorption loss in the optical communication wavelength of $1.55{\mu}m$ were investigated for application in low-loss waveguide materials. The fluorinated polymaleimides were prepared from two monomers phenylmaleimide (H-PMI) and pentafluorophenylmaleimide (F-PMI). All synthesized copolymers had high thermal stability (decomposition temperature $(T_d)=380-430^{\circ}C$). The refractive index of the copolymers could be tuned from 1.4969 to 1.5950 in the TE mode and from 1.4993 to 1.5932 for the TM mode at 632.8 nm by copolymerizing different weight ratios of H-PMI and F-PMI. The refractive index of the copolymers decreased with increasing F-PMI content. In addition, when the amount of F-PMI was increased, optical loss and absorption loss at 632.8 nm and 1550 nm, respectively, decreased.

Improvement in the Super Low Core-loss Soft Magnetic Materials

  • Maeda, Toru;Sato, Atsushi;Mochida, Yasushi;Toyoda, Haruhisa;Mimura, Koji;Nishioka, Takao
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1284-1285
    • /
    • 2006
  • We reported a P/M soft magnetic material with core loss value of $W_{10/1k}=68W/kg$, which is lower than that of 0.35mm-thick laminated material, by using high purity gas-atomized iron powder. Lack of mechanical strength and high cost of powder production are significant issues for industrial use. In order to achieve both low core loss and high strength by using inexpencive powder, the improvement of powder shape and surface morphology and binder strength was conducted. As the result, the material based on water-atomized powder with 80 MPa of TRS and 108 W/kg of core loss (W10/1k) was achieved.

  • PDF

Analysis of Loss Charateristics of Electronic Ballast for 250W HID-lamp (250W HID 램프용 전자식 안정기의 손실 특성 분석)

  • Park, Chong-Yeon;Jung, Kwang-Hyun;Suk, Kyung-Su;Park, Chang-Yeol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.333-337
    • /
    • 2005
  • We have studied the loss characteristics of the electronic ballast for the 250 watt HID lamps. The researched electronic ballast has a low loss, a low THD for input current and the other reliable characteristics. By the experrimental results and the analytical method, we concluded that the switching devices loss is 33%, and the Inductances loss is 42.6% of the total losses.

  • PDF

Path Loss Exponent Estimation for Indoor Wireless Sensor Positioning

  • Lu, Yu-Sheng;Lai, Chin-Feng;Hu, Chia-Cheng;Huang, Yueh-Min;Ge, Xiao-Hu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.3
    • /
    • pp.243-257
    • /
    • 2010
  • Rapid developments in wireless sensor networks have extended many applications, hence, many studies have developed wireless sensor network positioning systems for indoor environments. Among those systems, the Global Position System (GPS) is unsuitable for indoor environments due to Line-Of-Sight (LOS) limitations, while the wireless sensor network is more suitable, given its advantages of low cost, easy installation, and low energy consumption. Due to the complex settings of indoor environments and the high demands for precision, the implementation of an indoor positioning system is difficult to construct. This study adopts a low-cost positioning method that does not require additional hardware, and uses the received signal strength (RSS) values from the receiver node to estimate the distance between the test objects. Since many objects in indoor environments would attenuate the radio signals and cause errors in estimation distances, knowing the path loss exponent (PLE) in an environment is crucial. However, most studies preset a fixed PLE, and then substitute it into a radio propagation loss model to estimate the distance between the test points; such method would lead to serious errors. To address this problem, this study proposes a Path Loss Exponent Estimation Algorithm, which uses only four beacon nodes to construct a radio propagation loss model for an indoor environment, and is able to provide enhanced positioning precision, accurate positioning services, low cost, and high efficiency.

QoS Improvement Scheme in Optical Burst Switching using Dynamic Burst length Adjustment (광 버스트 스위칭에서 버스트 길이의 동적 조절을 통한 QoS 향상방법)

  • Sanghoon Hong;Lee, Sungchang
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.12
    • /
    • pp.136-144
    • /
    • 2003
  • In this paper, we propose a scheme that can control the loss probability of low priority class bursts by dynamically adjusting the assembly threshold of low priority class. The key ideas is that the loss Probability of the longer burst increases as the load increases, thus reduced low priority class burst length decreases the loss priority at high traffic load. To achieve this aim, we first derive the relation among the loss probability, the assembly threshold, and the traffic load. In this paper we derive the relation by curve fitting on the simulation results. The ingress edge routers periodically or by event-driven receives the proper corresponding assembly threshold information from the core routers. This assembly threshold is calculated from the derived relation so that the required loss probability of the low priority class bursts in the network is satisfied. The simulation results show that the proposed scheme performs well to meet the loss probability target as expected.

Prediction of the Occurring Time of Stall for a Booster Fan in a Power Plant Combusting Low Quality Coal through Draft Loss (저품위탄 연소시 탈황용 승압송풍기 실속시점 예측)

  • Kim, Yeong-Gyun;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.8 no.4
    • /
    • pp.34-39
    • /
    • 2012
  • This study presents how low quality coal combustion affects the desulfurizer draft system by correlating of draft loss in a coal-fired thermal power plant and predicts the stall occurrence time of a booster fan. In case of low quality coal, a lot of coal is needed to generate equivalent output power, thereby the rating of increasing draft loss was faster than designed amount of coal. We surely confirmed that draft loss affects the specific energy of a booster fan strongly. On this basis, it is possible to predict the occurring time of stall for a booster fan from current operation specific energy to stall limit specific energy. This study suggests increasing speed of draft loss in each caloric value and the impact of specific energy at a booster fan, it expects to help safe operating in a thermal power plant.

  • PDF

Effects of Heat Losses on Edge-flame Instabilities in Low Strain Rate Counterflow Diffusion Flames (저신장율 대향류확산화염에서 에지화염 불안정성에 관한 열손실 효과)

  • Park June-Sung;Hwang Dong-Jin;Kim Jeong-Soo;Keel Sang-In;Kim Tae-Kwon;Park Jeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.10 s.253
    • /
    • pp.996-1002
    • /
    • 2006
  • Experiments in methane-air low strain rate counterflow diffusion flames diluted with nitrogen have been conducted to study the behavior of flame extinction and edge flame oscillation in which flame length is less than the burner diameter and thus lateral conduction heat loss in addition to radiative heat loss could be remarkable at low global strain rates. Critical mole fraction at flame extinction is examined with velocity ratio and global strain rate. Onset conditions of edge flame oscillation and flame oscillation modes are also provided with global strain rate and added nitrogen mole fraction to fuel stream (fuel Lewis number). It is seen that flame length is closely relevant to lateral heat loss, and this affects flame extinction and edge flame oscillation considerably. Edge flame oscillations in low strain rate flames are experimentally described well and are categorized into three: a growing oscillation mode, a decaying oscillation mode, and a harmonic oscillation mode. The regime of flame oscillation is also provided at low strain rate flames. Important contribution of lateral heat loss even to edge flame oscillation is clarified

Performance Evaluation of Finned Tube Heat Exchanger with Vortex Generators in a Low Reynolds Number Regime (레이놀즈 수가 낮은 영역에서 와류발생기를 적용한 핀-관 열교환기 성능평가)

  • Kwak Kyung-Min;Song Gil-Dal
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.151-157
    • /
    • 2006
  • The present paper reports the method for evaluation of heat-transfer performance of finned tube heat exchangers in a low Reynolds number regime (Re = $160\~800$) and also reports the data of heat transfer and pressure loss taken from a finned tube heat exchanger with/without vortex generators (VGs) installed as a heat-transfer enhancement device. The evaluation is based on the modified single blow method conducted in a specially designed low Reynolds number duct. Three different test core geometries, i.e., fin only, fin-tube without VGs and that with VGs, are studied here. The data of heat transfer and pressure loss taken from the fin only geometry agree well with the empirical correlations, thus validating the present method as used for low Reynolds number regime. The data taken from the finned tube geometries with and without VGs are presented and compared to examine the effect of VGs in the low Reynolds number regime.

Low Temperature Methane Steam Reforming for Hydrogen Production for Fuel Cells

  • Roh, Hyun-Seog;Jun, Ki-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.153-156
    • /
    • 2009
  • Low temperature methane steam reforming to produce $H_2$ for fuel cells has been calculated thermodynamically considering both heat loss of the reformer and unreacted $H_2$ in fuel cell stack. According to the thermodynamic equilibrium analysis, it is possible to operate methane steam reforming at low temperatures. A scheme for the low temperature methane steam reforming to produce $H_2$ for fuel cells by burning both unconverted $CH_4$ and $H_2$ to supply the heat for steam methane reforming has been proposed. The calculated value of the heat balance temperature is strongly dependent upon the amount of unreacted $H_2$ and heat loss of the reformer. If unreacted $H_2$ increases, less methane is required because unreacted $H_2$ can be burned to supply the heat. As a consequence, it is suitable to increase the reaction temperature for getting higher $CH_4$ conversion and more $H_2$ for fuel cell stack. If heat loss increases from the reformer, it is necessary to supply more heat for the endothermic methane steam reforming reaction from burning unconverted $CH_4$, resulting in decreasing the reforming temperature. Experimentally, it has been confirmed that low temperature methane steam reforming is possible with stable activity.