• Title/Summary/Keyword: low leakage

Search Result 1,336, Processing Time 0.029 seconds

Fabrication and Characteristics of ultra power-saving Schottky barrier rectifier (초절전형 Schottky barrier rectifier의 제조 및 그 특성)

  • Kim, Jun-Sik;Choe, Yeong-Ho;Park, Geun-Yeong;Choe, Si-Yeong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.4
    • /
    • pp.35-40
    • /
    • 2002
  • Ultra-power-saving SBR has been fabricated by using vanadium and molybdenum with low work function. Because reverse leakage current is increased in inverse proportion to work function, we implanted argon ion on the n-Si layer for decreasing leakage current. The dose and acceleration energy of the argon implantation in the silicon was 1$\times$10$^{14}$ ion/$\textrm{cm}^2$, 40 keV, respectively. The forward voltages drop of fabricated V-SBR and Mo-SBR were 0.25 V and 0.39 V at the same forward current density of 60 A/$\textrm{cm}^2$. As a result, it was found that the reverse leakage current of the fabricated V-SBR was reduced over 20$mutextrm{A}$ by the argon implantation in comparison with the no implanted V-SBR. Also, owing to argon implantation, the inferiority of characteristic of the SBR was not detected.

Research on MFL PIG Design for the Inspection of Underground Gas Pipeline (지하매설 가스관의 검사를 위한 누설자속탐상 PIG 설계에 관한 연구)

  • Park, Sang-Ho;Park, Gwan-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.177-186
    • /
    • 2002
  • This paper describes the magnetic flux leakage(MFL) type non-destructive testing(NDT) system to detect the 3D defects in underground gas pipe. Magnetic systems with permanent magnets and yokes are analyzed by 3D non-lineal finite element method(FEM) with optimum design. In case of under-saturation of gas pipe, sensing signals are too weak to detect. In case of over-saturation, the changes of the sensing signals are too low to detect the defects sensitively. So, the operating points of the magnetic system are optimized to increase the changes of the MFL signals. The effects of the depth and size of the defects on the sensing signals are analyzed to define the range and resolution of the MFL sensors. To increase the sensor's sensitivity, the back-yoke sensors are introduced and tested.

The Fabrication and Property Evaluation of Poly-crystalline CdTe based Photon Counting X-ray Sensor (다결정 CdTe 기반의 광계수형 X선 센서 제작 및 특성평가)

  • Kang, Sang Sik;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.439-443
    • /
    • 2015
  • An electrical signals of a conventional radiation medical imaging sensor are obtained by charge integration method. In this study, the polycrystalline cadmium telluride(p-CdTe) film was fabricated by a thermal evaporation method for the photon counting sensor development with excellent resolution in low exposure dose. From the fabricated p-CdTe sensor, the physical properties(SEM, XRD) and the electrical properties(leakage current, x-ray sensitivity, SNR) were evaluated. As a result, the leakage current of below $5nA/cm^2$ and $7{\mu}C/cm^2-R$ of the X-ray sensitivity were showed in below $1V/{\mu}m$. In addition, the signal to noise ratio showed the values of above 5000 at operating voltage.

Detection Probability Improvement Scheme Optimized for Frequency-Hopping Signal Detection (주파수 도약 신호 탐지에 최적화된 탐지 확률 향상 기법)

  • Lee, In-Seok;Oh, Seong-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.10
    • /
    • pp.783-790
    • /
    • 2018
  • The frequency-hopping technique is one of the spread-spectrum techniques. Frequency hopping is a communication system in which the carrier frequency channel is hopped within the wideband. Therefore, a frequency-hopping system has such advantages as antijamming and low probability of intercept. This system is often used in military communications. Because frequency-hopping signal detection is difficult, it is an important research issue. A novel detection technique is proposed that can improve detection probability. When the received signal is transformed to a frequency domain sample by fast Fourier transform, spectral leakage lowers the detection probability. This problem can be solved by using the Hamming window, and the detection probability can be increased. However, in a frequency-hopping environment, the windowing technique lowers the detection probability. The proposed method solves this weakness. The simulation results show that the proposed detection technique improves the detection probability by as much as 13 %.

Malfunction Characteristics of Earth Leakage Circuit Breakers against Electrical Surges (서지에 대한 누전차단기의 오동작 특성)

  • Song Jae-Yong;Han Joo-Sup;Park Dae-Won;Seo Hwang-Dong;Kil Gyung-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.570-575
    • /
    • 2005
  • Malfunction by electrical surges is a serious problem on earth leakage current breakers(ELBs) used in a low voltage AC power system. In this paper, we tested ELBs according to IEC 61009-1 and KS C 4613 to analyze surge influence on ELB's malfunction. The test by application of surge voltage is specified both standards, but the test by application of surge current is specified only in IEC 61009-1. The experimental results showed that the ELBs used in this test are robust to surge voltage application, but the malfunction occurred to surge current application. Surge current is more frequent than surge voltage in actual situation. Therefore, ELBs should be tested by the surge current, and the domestic standard, KS C 4613, should includes a test procedure by the surge current application.

A study on I-V characteristics in JBS rectifiers according to PN junction structures (JBS(Junction Barrier-controlled Schottky)정류기의 PN접합구조에 따른 I-V 특성에 관한 연구)

  • 안병목;정원채
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.1
    • /
    • pp.13-20
    • /
    • 2000
  • In this paper, we demonstrated an analytical description method of forward votage drop and reverse leakage current of the junction barrier controlled schottky rectifier with linearly graded junction and abrupt junction models. In this case, the vertical depths of device are 1[${\mu}{\textrm}{m}$] and 2[${\mu}{\textrm}{m}$], respectively. Through ion implantation and annealing process, we obtain the data of lateral and depth from implanted 2-dimensional profiles. Also we applied these data to models that indicate the change of depletion each on linearly-graded and abrupt juction as the forward and revers bias. After applied depletion changes to electric characteristics of JBS rectifiers, we calculated the forward I-V, the reverse leakage current and temperatures vs. power dissipations according to each junction. When we compared the rectifier with calculated and measured data, from the calculated results, forward votage drop with linearly graded junction is lower than that of abrupt junction and reverse leakage current with linearly graded junction is lower(≒1$\times$10\ulcorner times) than that of abrupt junction. Also, the power dissipations according to different juction depth(1[${\mu}{\textrm}{m}$], 2[${\mu}{\textrm}{m}$]) of device are calculated. Seeing the calculated results, we confirmed it from analytic model that the rectifier with linearly graded junction retained a low power dissipation up to 600[$^{\circ}C$] in comparison with the rectifier with abrupt junction.

  • PDF

Engineering Properties of Sewage Polymer Concrete Culvert (폴리머 콘크리트를 적용한 하수암거의 공학적 특성)

  • Kwon, Seung Jun;Min, Byung Yoon;Park, Sang Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.9-17
    • /
    • 2012
  • Concrete sewage culvert shows degradation with time since it is always exposed to various harmful ions, and deterioration of concrete culvert propagates to structural safety problems. After reclamation, maintenance for concrete sewage culvert is very difficult so that high durable and structural performance are essential for the sewage concrete culvert. Recently polymer concrete has been used to improve mechanical properties and durability performance. In this paper, engineering properties are evaluated for sewage culvert made with polymer concrete, and leakage and adhesive strength between joints are evaluated with small-scale models. The polymer sewage culvert shows high compressive strength over 100MPa with low water permeability and chloride penetration. Furthermore, high resistances to chemical and biological attack are evaluated. Through tests for leakage and adhesive, unification of joints is verified with evaluation of no leakage and high adhesive strength. Precast polymer sewage culvert in this paper can be actively used for severe conditions like sewage lines.

Effect of Relative Position of Vane and Blade on Heat/Mass Transfer Characteristics on Stationary Turbine Blade Surface (베인과 블레이드 사이의 상대위치 변화에 따른 터빈 블레이드 표면에서의 열/물질전달 특성)

  • Rhee, Dong-Ho;Cho, Hyung Hee
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.4 s.31
    • /
    • pp.27-38
    • /
    • 2005
  • The present study investigated the effect of relative position of the blade on blade surface heat transfer. The experiments were conducted in a low speed wind tunnel with a stationary annular turbine cascade. The test section has a single turbine stage composed of sixteen guide vanes and blades. The chord length of the blade is 150 mm and the mean tip clearance of the blade is $2.5\%$ of the blade chord. The Reynolds number based on blade inlet velocity and chord length is $1.5{\times}105$ and mean turbulence intensity is about $3\%$. To investigate the effect of relative position of blade, the blade at six different positions in a pitch was examined. For the detailed mass transfer measurements, a naphthalene sublimation technique was used. In general, complex heat transfer characteristics are observed on the blade surface due to various flow characteristics, such as a laminar flow separation, relaminarization, flow acceleration, transition to turbulence and tip leakage vortices. The results show that the blade relative position affects those heat transfer characteristics because the distributions of incoming flow velocity and turbulence intensity are changed. Especially, the heat transfer pattern on the near-tip region is significantly affected by the relative position of the blade because the effect of tip leakage vortex is strongly dependent on the blade position. On the pressure side, the effect of blade position is not so significant as on the suction side surface although the position and the size of the separation bubble are changed.

Effect of Sintering Temperature on Electrical Stability of $Pr_{6}O_{11}$-Based ZnO Varistors ($Pr_{6}O_{11}$계 ZnO 바리스터의 전기적 안정성에 소결온도의 영향)

  • 남춘우;류정선
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.8
    • /
    • pp.640-646
    • /
    • 2001
  • The electrical stability for DC stress of Pr$_{6}$O$_{11}$-based ZnO varistos consisting of ZnO-Pr$_{6}$O$_{11}$-CoO-Cr$_2$O$_3$-Er$_2$O$_3$-based ceramics were investigated with sintering temperature in the range of 1325~1345$^{\circ}C$. A the sintering temperature is raised, the nonlinear exponent of varistors was decreased, whereas the stability was markedly improved. The density of ceramics was found to greatly affect the electrical stability for DC stress. The varistors sintered at 13$25^{\circ}C$ were completely degraded because of thermal runaway attributing to low density. The varistors sintered at 1335$^{\circ}C$ exhibited the highest nonlinearity, with a nonlinear exponent of 70.53 and a leakage current of 1.92$\mu$A, whereas they did not exhibit relatively high stability. On the contrary, the varistors sintered at >134$0^{\circ}C$ exhibited not only a high nonlinearity marking the nonlinear exponent above 50 and the leakage current below 3$\mu$A, but also a high stability marking the variation rate of the varistor voltage below 2%, even under DC stress such as (0.80V$_{1mA}$/9$0^{\circ}C$/12h)+(0.85V$_{1mA}$/115$^{\circ}C$/12h)+(0.90V$_{1mA}$/12$0^{\circ}C$/12h)+(0.95V$_{1mA}$/1$25^{\circ}C$/12h)+(0.95V$_{1mA}$/15$0^{\circ}C$/12h). In particular, ti was found that the varistors sintered at 134$0^{\circ}C$ were more nonlinear and more stable, compared with that of 1345$^{\circ}C$.EX>.}C$.EX>.

  • PDF

A Study on the microstructure and Surge Characteristics of ZnO varistors for distribution Arrester (배전급 피뢰기용 ZnO 바리스터 소자의 미세구조 및 서지 특성에 관한 연구)

  • 김석수;조한구;박태곤;박춘현;정세영;김병규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.2
    • /
    • pp.190-197
    • /
    • 2002
  • In this thesis, ZnO varistors with various formulation, such as A∼E, were fabricated according to ceramic fabrication method. The microstructure, electrical properties, and surge characteristics of ZnO varistors were investigated according to ZnO varistors with various formulation. In the microstructure, A∼E\`s ZnO varistor ceramics sintered at 1130$\^{C}$ was consisted of ZnO grain(ZnO), spinel phase (Zn$\_$2.33/Sb$\_$0.67/O$\_$4/), Bi-rich phase(Bi$_2$O$_3$) and intergranuler phase, wholly. Lightning impulse residual voltage of A, B, C and E\`s ZnO varistors suited standard characteristics, below 12kV at current of 5kA. On the contrary, D\`s ZnO varistor exhibited high residual voltage as high reference voltage. In the accelerated aging test, leakage current and watt loss of B, C and D\`s ZnO varistors increases abruptly with stress time under the first a.c. stress(115$\^{C}$/3.213kV/300h). Consequently, C varistor exhibited a thermal run away. On the contrary, leakage current and watt loss of A and C\`s ZnO varistors which show low initial leakage current exhibited constant characteristics. After high current impulse test, A\`s ZnO varistor has broken the side of varistor but impulse current flowed. On the contrary, E\`s ZnO Varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After long duration impulse current test, E\`s ZnO varistor exhibited good discharge characteristics which the appearance of varistor was not wrong such as puncture, flashover, creaking and other significant damage. After high current impulse test and long duration impulse current test, E\`s ZnO varistor exhibited very good characteristics which variation rate of residual voltage is 1.4% before and after test.