• Title/Summary/Keyword: low leakage

Search Result 1,336, Processing Time 0.031 seconds

Extended Low Anterior Resection with a Circular Stapler in Patients with Rectal Cancer: a Single Center Experience

  • Talaeezadeh, Abdolhasan;Bahadoram, Mohammad;Abtahian, Amin;Rezaee, Alireza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8141-8143
    • /
    • 2016
  • Background: to evaluate the outcome of stapled colo-anal anastomoses after extended low anterior resection for distal rectal carcinoma. Materials and Methods: A retrospective study of fifty patients who underwent coloanal anastomoses after extended low anterior resection was conducted at Imam Hospital from September 2007 up to July 2012. Results: The distance of the tumor from anal verge was 3 to 8 cm. Anastomotic leakage developed in 6% of patients and defecation problems in 16%. One-year local recurrence was 6% while three-year local recurrence was 4%. One-year systemic recurrence was seen in 22% while three-year systemic recurrence was seen in 20%. Conclusions: Colo-anal anastomoses after extended low anterior resection for distal rectal carcinoma can be conducted safely.

Reynolds Number Effect on Regenerative Pump Performance in Low Reynolds Number Range

  • Horiguchi, Hironori;Yumiba, Daisuke;Tsujimoto, Yoshinobu;Sakagami, Masaaki;Tanaka, Shigeo
    • International Journal of Fluid Machinery and Systems
    • /
    • v.1 no.1
    • /
    • pp.101-108
    • /
    • 2008
  • The effect of Reynolds number on the performance of a regenerative pump was examined in a low Reynolds number range in experiment. The head of the regenerative pump increased at low flow rates and decreased at high flow rates as the Reynolds number decreased. The computation of the internal flow was made to clarify the cause of the Reynolds number effect. At low flow rates, the head is decreased with increasing the Reynolds number due to the decrease of the shear force exerted by the impeller caused by the increase of leakage and hence local flow rate. At higher flow rates, the head is increased with increasing the Reynolds number with decreased loss at the inlet and outlet as well as the decreased shear stress on the casing wall.

Electrical characteristics of low-k SiOCH thin film deposited by BTMSM/$O_2$ high flow rates (BTMSM/$O_2$ 고유량으로 증착된 low-k SiOCH 박막의 전기적인 특성)

  • Kim, Min-Seok;Hwang, Chang-Su;Kim, Hong-Bae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.1
    • /
    • pp.41-45
    • /
    • 2008
  • We studied the electrical characteristics of low-k SiOCR interlayer dielectric(ILD) films fabricated by plasma enhanced chemical vapor deposition (PECVD). The precursor bis-trimethylsilylmethane (BTMSM) was introduced into the reaction chamber with the various flow rates. The absorption intensities of Si-O-$CH_x$, bonding group and Si-$CH_x$, bonding group changed synchronously for the variation of precursor flow rate, but the intensity of Si-O-Si(C) responded asynchronously with the $CH_x$, combined bonds. The SiOCH films revealed ultra low dielectric constant around 2.1(1) and reduced further below 2.0 by heat treatments.

  • PDF

A novel approach for designing of variability aware low-power logic gates

  • Sharma, Vijay Kumar
    • ETRI Journal
    • /
    • v.44 no.3
    • /
    • pp.491-503
    • /
    • 2022
  • Metal-oxide-semiconductor field-effect transistors (MOSFETs) are continuously scaling down in the nanoscale region to improve the functionality of integrated circuits. The scaling down of MOSFET devices causes short-channel effects in the nanoscale region. In nanoscale region, leakage current components are increasing, resulting in substantial power dissipation. Very large-scale integration designers are constantly exploring different effective methods of mitigating the power dissipation. In this study, a transistor-level input-controlled stacking (ICS) approach is proposed for minimizing significant power dissipation. A low-power ICS approach is extensively discussed to verify its importance in low-power applications. Circuit reliability is monitored for process and voltage and temperature variations. The ICS approach is designed and simulated using Cadence's tools and compared with existing low-power and high-speed techniques at a 22-nm technology node. The ICS approach decreases power dissipation by 84.95% at a cost of 5.89 times increase in propagation delay, and improves energy dissipation reliability by 82.54% compared with conventional circuit for a ring oscillator comprising 5-inverters.

Performance analysis of waterproofing corrosion as effecting oil (유류성분이 지하구조물의 방수층 침식에 미치는 영향평가)

  • 김영찬;이정윤;권시원;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2004.05a
    • /
    • pp.91-95
    • /
    • 2004
  • Utilization of underground construction if increased by the large size & skycraperlization of building recently. Therefore. waterproof dependence of underground construction is risen. However, water leakage was happened by rupture by concrete conduct, drying shrinkage. form tie. In underground environment soil class, degradation of waterproofing is showing to corrode by oil. An odious smell by oil, promotion evil of reinforcing rod corrosion, declination of durability can happen. Then, practical un degree of underground spare becomes low, Because oil or water permeates by construction by degradation to waterproof class corrode by oil, is considered to affect evil durability of construction.

  • PDF

Investigation of On-line Monitoring Method on 1500 V Direct Current Cable of Subway

  • Shen, Xiaojun;Jiang, Xiuchen;Yi, Zeng
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.247-251
    • /
    • 2006
  • The traction DC feeder cable is one of the key devices for the safety operation of subway system, but for low voltage DC feeder cable (<3000 V) for subway, little attention has been paid by investigators on its online monitoring technology. With an introduction of cable laying and operation environment for the cable, this paper investigated the on-line monitoring technology of 1500 V DC feeder cable of subway. Firstly, in the text, the fault model of 1500 V DC cable was proposed based on the analysis of the fault type of the DC feeder cable, and then put forward synthetically on-line monitoring discharge signal and DC leakage current signal to assess DC feeder cable insulating state. The results of laboratory experiment prove that the proposed methods are feasible and can be implemented on-line monitor on DC feeder cable of subway.

A Study on a Improvement of the Speech Quality by Spectrum Analysis with Variable Window in CELP Vocoder (가변 윈도우 스펙트럼 분석을 이용한 CELP 부호화기의 음질 향상에 관한 연구)

  • 나덕수;민소연;배명진
    • Proceedings of the IEEK Conference
    • /
    • 2000.06d
    • /
    • pp.106-109
    • /
    • 2000
  • There have been proposed two types of low bit rate vocoder upto now : One is MBE type using the spectrum modeling and another is CELP type using the hybrid coding method. CELP type vocoder has mainly studied between them. Specially, much of intensity is concentrated in CELP vocoder due to the emergence of Internet Phone and PCS in a domestic. In order to improve the speech quality in CELP vocoder, in this paper, we proposed a new spectrum analysis algorithm with variable window, In CELP vocoder, the spectrum of the synthesised speech signal is distorted because the fixed size windows is used for spectrum analysis. So we have measured the spectral leakage and in order to minimize the spectral leakage have adjusted the window size. Applying this method G.723.1 ACELP, we can get SD(Spectral Distortion) reduction 0.084(dB), residual energy reduction 6.3% and MOS(Mean Opinion Score) improvement 0.1.

  • PDF

Dielectric and Magnetic Properties of Niobium and Cobalt Co-substituted Multiferroic BiFeO3 Thin Films (Niobium과 Cobalt를 첨가한 Multiferroic BiFeO3 박막의 유전 특성 및 자성 특성)

  • Jun, Youn-Ki;Hong, Seong-Hyeon
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.9
    • /
    • pp.556-560
    • /
    • 2008
  • The effects of Nb and Co ion substitution on the dielectric and magnetic properties of the multiferroic $BiFeO_3$ thin films have been investigated. Heteroepitaxial $BiFeO_3$ thin films were deposited by Pulsed Laser Deposition method. Nb substitution decreased the leakage current by 6 orders of magnitude and Co substituted $BiFeO_3$ thin films showed an enhanced magnetization, 2 times larger than that of un-substituted $BiFeO_3$. Through the co-substitution of Co and Nb, $BiFeO_3$ thin films with a low leakage current and an enhanced magnetization could be obtained.

Wavelet-Based Flashover Prediction Using High-Frequency Components (고주파 성분을 사용한 웨이블렛 기반 섬락 예측)

  • Song, Young-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.759-761
    • /
    • 2010
  • In order to monitor operating performance of contaminated outdoor insulators, a wavelet-based flashover prediction method is proposed. In most cases, the low-frequency components, namely, fundamental, $3^{rd}$, and $5^{th}$ harmonic components have been mainly used for the sake of the spectral analysis of the leakage current. However, in this paper, the detail coefficients of wavelet transform representing high-frequency components are used as important information to predict a flashover in the contaminated insulator. Experimental results verify that the proposed method has a superior capability for flashover prediction.

The characteristic study of hybrid X-ray detector using ZnS:Ag phosphor (ZnS:Ag phosphor를 이용한 hybrid 형 X-ray detector 특성 연구)

  • Park, Ji-Koon;Gang, Sang-Sik;Lee, Dong-Gil;Cha, Byeong-Yeol;Nam, Sang-Hee;Choi, Heung-Kook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.27-30
    • /
    • 2002
  • Photoconductor for direct detection flat-panel imager present a great materials challenge, since their requirements include high X -ray absorption, ionization and charge collection, low leakage current and large area deposition. Selenium is practical material. But it needs high thickness and high voltage in selenium for high ionization rate. We report comparative studies of detector sensitivity. One is an a-Se with $70{\mu}m$ thickness on glass. The other has hybrid layer of depositting ZnS phosphor with $100{\mu}m$ on a-Se. The leakage current of hybrid is similar to it of a-Se, but photocurrent is lager than a-Se. Both of them have high spatial resolution, but hybrid has higher sensitivity than a-Se at comparable bias voltage.

  • PDF