• Title/Summary/Keyword: low frequency inverter

Search Result 397, Processing Time 0.031 seconds

High Frequency Link PCS for Interfacing with Power Utility System (고주파링크 전력계통 연계형 PCS)

  • Chung, Bong-Gun;Yoon, Kwang-Ho;Lee, Kwang-Ho;Kim, Eun-Soo;Cha, In-Su
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.60-68
    • /
    • 2010
  • Recently, Power Conditioning System (PCS) tends to require more compact, higher efficiency and power density with better performance. A novel topology consisted of LLC resonant inverter and Low Frequency (LF) cyclo-converter for connecting to utility line is able to meet these requirements. The technical operating analysis is described and 1kW prototype is tested and verified the performances through connecting the 110Vac 60Hz utility line. Efficient results are described.

The Development of the Buck Type Electronic Dimming Ballast for 250W MHL

  • Jung, Dong-Youl;Park, Chong-Yeon
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.4
    • /
    • pp.496-502
    • /
    • 2006
  • In this paper, we studied the development of the electronic ballast for 250W MH (Metal-Halide) lamps. We were able to improve the input power factor by using a PFC IC. To provide the lamp with the rated voltage required, we used the buck-type dc-dc converter. The stress of the switching devices in the inverter could be reduced by this method. To eliminate the acoustic resonance phenomena of MH lamps, the voltage of the lamp added the high frequency sine-wave to the low frequency square-wave by using the full bridge typed inverter. We have developed a simple igniter using the L and C elements. We could control the dimness of the lamp by varying the output voltage of the buck converter. The buck converter output voltage could be controlled by using a microprocessor.

A new control scheme of Class-E electronic Ballast with low crest factor (저 파고율 특성을 갖는 Class-E 전자식 안정기의 새로운 제어 기법)

  • Chon, Hyun-Son;Lee, Dong-Yun;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.234-236
    • /
    • 2003
  • In this paper, a new control scheme of Class-E inverter for reducing the crest factor of electronic ballasts for fluorescent lamps using Pulse-Frequency-Modulation (PFM) is introduced The lifetime of the lamps is guaranteed by decreasing the lamp crest factor and voltage stress of the switch is significantly decreased by a new scheme although conventional Class-E inverter is used in this paper The proposed PFM control scheme doesn't used any auxiliary circuit. The proposed control strategy is executed by feeding back the input current. and the Zero-Voltage-Switching (ZVS) is ensured by operating beyond resonant frequency. Therefore, the control principles of proposed method are explained in detail and its validity is verified through several simulated results.

  • PDF

Study on grid-connected photovoltaic 3 kW Inverter (3kW급 계통 연계형 태양광 인버터에 관한 연구)

  • Song, S.G.;Lee, S.H.;Park, S.J.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.707-710
    • /
    • 2005
  • This paper presents a 3kW grid-connection photovoltaic power generation system and its topology. Photovoltaic system must provide the sinusoidal output voltage wave for unity power factor High frequency switching converters are becoming more popular because of several benefits which are essential in power conversion system. This paper introduces a high speed digital controller using TMS320F2812 DSP chip which can be used for high frequency switching converters. The experimental results of the proposed PWM Inverter demonstrates its high performance with unity input power factor having very low distorsion in input current waveforms and good dynamic characteristics at full load.

  • PDF

Analysis and Implementation of Multiphase Multilevel Hybrid Single Carrier Sinusoidal Modulation

  • Govindaraju, C.;Baskaran, K.
    • Journal of Power Electronics
    • /
    • v.10 no.4
    • /
    • pp.365-373
    • /
    • 2010
  • This paper proposes a hybrid single carrier sinusoidal modulation suitable for multiphase multilevel inverters. Multiphase multilevel inverters are controlled by hybrid modulation to provide multiphase variable voltage and a variable frequency supply. The proposed modulation combines the benefits of fundamental frequency modulation and single carrier sinusoidal modulation (SC-SPWM) strategies. The main characteristics of hybrid modulation are a reduction in switching losses and improved harmonic performance. The proposed algorithm can be applied to cascaded multilevel inverter topologies. It has low computational complexity and it is suitable for hardware implementations. SC-SPWM and its base modulation design are implemented on a TMS320F2407 digital signal processor (DSP). A Complex Programmable Logic Device realizes the hybrid PWM algorithm and it is integrated with a DSP processor for hybrid SC-SPWM generation. The feasibility of this hybrid modulation is verified by spectral analysis, power loss analysis, simulation and experimental results.

Development of control algorithm for TTX Tilting Train eXpress propulsion system (틸팅 차량용 추진제어장치의 제어 알고리즘 개발)

  • Kim, Hyung-Cheol;Lee, Eun-Kyu;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1343-1345
    • /
    • 2005
  • In this paper, control schemes are proposed for a propulsion system(Converter/Inverter) of the TTX(Tilting Train express). In developed traction converter, unity power factor control, compensation method of dc link voltage have been applied. Output current of converter contains harmonics ripple at twice input ac line frequency, which causes a ripple in the dc link voltage so that control scheme is developed in inverter system to reduce the pulsating torque current. At low speed region, vector control scheme is applied and slip frequency control is adopted at high speed region. The performance of propulsion system will be verified by simulation and prototype experimental results.

  • PDF

A Modified Single-Phase Transformerless Z-Source Photovoltaic Grid-Connected Inverter

  • Liu, Hongpeng;Liu, Guihua;Ran, Yan;Wang, Gaolin;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1217-1226
    • /
    • 2015
  • In a grid-connected photovoltaic (PV) system, the traditional Z-source inverter uses a low frequency transformer to ensure galvanic isolation between the grid and the PV system. In order to combine the advantages of both Z-source inverters and transformerless PV inverters, this paper presents a modified single-phase transformerless Z-source PV grid-connected inverter and a corresponding PWM strategy to eliminate the ground leakage current. By utilizing two reversed-biased diodes, the path for the leakage current is blocked during the shoot-through state. Meanwhile, by turning off an additional switch, the PV array is decoupled from the grid during the freewheeling state. In this paper, the operation principle, PWM strategy and common-mode (CM) characteristic of the modified transformerless Z-source inverter are illustrated. Furthermore, the influence of the junction capacitances of the power switches is analyzed in detail. The total losses of the main electrical components are evaluated and compared. Finally, a theoretical analysis is presented and corroborated by experimental results from a 1-kW laboratory prototype.

Output Filter Design for Conducted EMI Reduction of PWM Inverter-Fed AC Motor Drive System (PWM 인버터 시스템에서의 전도노이즈 저감을 위한 출력필터 설계에 관한 연구)

  • 김이훈;박규현;원충연;김영석;최세완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.546-555
    • /
    • 2001
  • In this paper filtering techniques to reduce the adverse effects of motor leads on high-frequency PWM inverter fed AC motor drives are presented. The filter was designed to keep the motor terminal from the cable surge impedance to reduce overvoltage reflections ringing and the dv/dt, di/dt, at the motor terminals. Specially the output filter is used to limit the rate of the inverter output voltage and reduce common mode noise to the motor, The performance of the output filter is evaluated through simulations and experiment on PWM inverter-fed AC motor drive. An experimental PWM drive system reduction of conducted EMI was implemented on an available TMS320C31 microprocessor control board Finally, experimental result shows inverter output filter reduces more common mode voltage than low pass filter also reduce overoltage and ringing at the motor terminal.

  • PDF

Characteristic Evaluation of Medical X-Ray Using High-Voltage Generator with Inverter System (인버터방식의 고전압 발생장치를 이용한 의료용 X선 기기의 특성평가)

  • Kim, Young-Pyo;Cheon, Min-Woo;Park, Yong-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.36-41
    • /
    • 2011
  • Medical X-ray has been brought many changes according to the rapid development of high technology. Especially, for high-voltage generator which is the most important in X-ray generation the traditional way is to use high-voltage electric transformers primarily. However, since it is large and heavy and the ripple rate of DC high-voltage applied to X-ray tube is too big, it has a disadvantage of low X-ray production efficiency. To solve these problems, the studies about high-voltage power supply are now proceeding. At present, the high-voltage generator that generates high-voltage by making high frequency using inverter control circuit consisting of semiconductor device is mainly used. High-voltage generator using inverter has advantages in the diagnosis using X-ray including high performance with short-term use, miniaturization of power supply and ripple reduction. In this study, the X-ray high-voltage device with inverter type using pulse width modulation scheme to the control of tube voltage and tube current was designed and produced. For performance evaluation of produced device, the control signal analysis, irradiation dose change and beam quality depending on the load variation of tube voltage and tube current were evaluated.

Partial O-state Clamping PWM Method for Three-Level NPC Inverter with a SiC Clamp Diode

  • Ku, Nam-Joon;Kim, Rae-Young;Hyun, Dong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1066-1074
    • /
    • 2015
  • This paper presents the reverse recovery characteristic according to the change of switching states when Si diode and SiC diode are used as clamp diode and proposes a method to minimize the switching loss containing the reverse recovery loss in the neutral-point-clamped inverter at low modulation index. The previous papers introduce many multiple circuits replacing Si diode with SiC diode to reduce the switching loss. In the neutral-point-clamped inverter, the switching loss can be also reduced by replacing device in the clamp diode. However, the switching loss in IGBT is large and the reduced switching loss cannot be still neglected. It is expected that the reverse recovery effect can be infrequent and the switching loss can be considerably reduced by the proposed method. Therefore, it is also possible to operate the inverter at the higher frequency with the better system efficiency and reduce the volume, weight and cost of filters and heatsink. The effectiveness of the proposed method is verified by numerical analysis and experiment results.