• Title/Summary/Keyword: low frequency

Search Result 11,436, Processing Time 0.039 seconds

Design and Fabrication of Low Phase-Noise Frequency Synthesizer using Dual Loop PLL for IMT-2000 (이중루프 PLL을 이용한 IMT-2000용 저위상잡음 주파수합성기의 설계 및 제작)

  • 김광선;최현철
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.163-166
    • /
    • 1999
  • In this paper, frequency synthesizer that can be used in IMT-2000 was designed and fabricated using dual loop PLL(Phase Locked Loop). For improving phase noise characteristic Voltage Controlled Oscillator was fabricated using coaxial resonator and eliminated frequency divider using SPD as phase detector and increased open loop gain. Fabricated frequency synthesizer had 1.82㎓ center frequency, 160MHz tuning range and -119.73㏈c/Hz low phase noise characteristic.

  • PDF

중금속으로 오염된 포화사질토의 저주파대에서의 유전특성

  • 방선영;오명학;김용성;박준범
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.289-292
    • /
    • 2003
  • Laboratory tests were performed to investigate the dielectric property of saturated sands contaminated by heavy metals solution at low frequency. Differences of contamination and the real part of dielectric constant depend on heavy metal concentration was measured at low frequency, 100KHz below. The optimal frequency to develop the detection potentials of monitoring was 1KHz, 10KHz, 100KHz. At this frequency, Heavy metal contamination of saturated sands contamination can be recommended by analysis of complex dielectric constant.

  • PDF

THE EFFECT OF EXTREMELY LOW FREQUENCY MAGNETIC FIELD (ELF-MF) ON THE FREQUENCY OF MICRONUCLEI IN HUMAN LYMPHOCYTES INDUCED BY BENZO(A)PYRENE

  • Cho, Yoon-Hee;Kim, Su-Young;Chung, Hai-Won
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2001.10a
    • /
    • pp.178-178
    • /
    • 2001
  • The interaction of extremely low frequency magnetic field (ELF-MF) on the frequency of micronuclei (MN) induced by benzo(a)pyrene (BP) in human lymphocytes was examined. A 60 Hz ELF-MF of 0.8 mT field strength was applied for 24 hours either alone or with the tumour initiator, BP. The frequency of MN induced by BP increased in a dose-dependent manner.(omitted)

  • PDF

A 50-mA 1-nF Low-Voltage Low-Dropout Voltage Regulator for SoC Applications

  • Giustolisi, Gianluca;Palumbo, Gaetano;Spitale, Ester
    • ETRI Journal
    • /
    • v.32 no.4
    • /
    • pp.520-529
    • /
    • 2010
  • In this paper, we present a low-voltage low-dropout voltage regulator (LDO) for a system-on-chip (SoC) application which, exploiting the multiplication of the Miller effect through the use of a current amplifier, is frequency compensated up to 1-nF capacitive load. The topology and the strategy adopted to design the LDO and the related compensation frequency network are described in detail. The LDO works with a supply voltage as low as 1.2 V and provides a maximum load current of 50 mA with a drop-out voltage of 200 mV: the total integrated compensation capacitance is about 40 pF. Measurement results as well as comparison with other SoC LDOs demonstrate the advantage of the proposed topology.

An Epidemiologic Study of Low Back Pain of Women Working at a General Hospital (종합병원 근무 여성의 요통에 대한 요인 분석)

  • Park, Dong-Gu;Ahn, Myun-Whan;Ahn, Jong-Chul;Kim, Sae-Dong;Seo, Jae-Sung
    • Journal of Yeungnam Medical Science
    • /
    • v.24 no.2
    • /
    • pp.186-196
    • /
    • 2007
  • Background : The aim of this study was to confirm the risk factors for low back pain and injury to improve the prevention and treatment of lower back pain. Materials and Methods : An epidemiologic study of low back pain and injury was performed with questionnaires distributed to 471 women working at Yeungnam university hospital. The differences in low back pain and injuries among various hospital departments were analyzed by a one-way analysis of variance (ANOVA), and the relevant factors included in the questionnaire were determined by a factor analysis. Results : The frequency of low back pain in women in the department of diet and in the maintenance department was higher than among the other departments. The frequency of low back pain was mainly related to the frequency of psychosomatic symptoms. In addition, the low back pain was partially related to the frequency of psychosomatic symptoms and partially related to the frequency of pushing during the workday. The degree of disability from low back pain was increased by lifting and hard physical work and was related to the frequency of psychosomatic symptoms and the degree of work dissatisfaction. The frequency of low back injury was increased by increased standing time during work and hard physical work. The frequency of low back injury was related to advancing age and in part to psychosomatic symptoms. Conclusion : Lower back pain and its associated complications are related to psychosomatic factors and type of work. Lower back injury is related to physiological factors such as age. For the prevention and treatment of lower back pain, a multidisciplinary approach is required.

  • PDF

Output Noise Reduction Technique Based on Frequency Hopping in a DC-DC Converter for BLE Applications

  • Park, Ju-Hyun;Kim, Sung Jin;Lee, Joo Young;Park, Sang Hyeon;Lee, Ju Ri;Kim, Sang Yun;Kim, Hong Jin;Lee, Kang-Yoon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.5
    • /
    • pp.371-378
    • /
    • 2015
  • In this paper, a different type of pulse width modulation (PWM) control scheme for a buck converter is introduced. The proposed buck converter uses PWM with frequency hopping and a low quiescent.current low dropout (LDO) voltage regulator with a power supply rejection ratio enhancer to reduce high spurs, harmonics and output voltage ripples. The low quiescent.current LDO voltage regulator is not described in this paper. A three-bit binary-to-thermometer decoder scheme and voltage ripple controller (VRC) is implemented to achieve low voltage ripple less than 3mV to increase the efficiency of the buck converter. An internal clock that is synchronized to the internal switching frequency is used to set the hopping rate. A center frequency of 2.5MHz was chosen because of the bluetooth low energy (BLE) application. This proposed DC-DC buck converter is available for low-current noise-sensitive loads such as BLE and radio frequency loads in portable communications devices. Thus, a high-efficiency and low-voltage ripple is required. This results in a less than 2% drop in the regulator's efficiency, and a less than 3mV voltage ripple, with -26 dBm peak spur reduction operating in the buck converter.

Contrast Sensitivity as a Function of Spatial Frequency for 12 Year Old Child-Eye (눈의 공간주파수와 대비 민감도 함수(CSF) 특성에 대한 연구)

  • Kim, Yong Geun;Park, Sang-An
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.63-68
    • /
    • 1999
  • It was made of a chart by new method to be measured the contrast sensitivity for a spatial frequency, and the mean luminance of a lattice frequency was made to three forms of 25, 50, 75% and let it to be ready a CS value from 0 to $10^3$. As a result of measuring of the CS value for a spatial frequency on a target of 12 year old students, CS value decreased of according to down the average luminance value and also the peak position shift to low spatial frequency. The low visioned person decreased the CS value in side of high frequency or in space of total frequency. By the lattice adaptation, a measured CS value was decreased in circumstance regions of adapted space frequency.

  • PDF

A New DPWM Method to Suppress the Low Frequency Oscillation of the Neutral-Point Voltage for NPC Three-Level Inverters

  • Lyu, Jianguo;Hu, Wenbin;Wu, Fuyun;Yao, Kai;Wu, Junji
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1207-1216
    • /
    • 2015
  • In order to suppress the low frequency oscillation of the neutral-point voltage for three-level inverters, this paper proposes a new discontinuous pulse width modulation (DPWM) control method. The conventional sinusoidal pulse width modulation (SPWM) control has no effect on balancing the neutral-point voltage. Based on the basic control principle of DPWM, the relationship between the reference space voltage vector and the neutral-point current is analyzed. The proposed method suppresses the low frequency oscillation of the neutral-point voltage by keeping the switches of a certain phase no switching in one carrier cycle. So the operating time of the positive and negative small vectors is equal. Comparing with the conventional SPWM control method, the proposed DPWM control method suppresses the low frequency oscillation of the neutral-point voltage, decreases the output waveform harmonics, and increases both the output waveform quality and the system efficiency. An experiment has been realized by a neutral-point clamped (NPC) three-level inverter prototype based on STM32F407-CPLD. The experimental results verify the correctness of the theoretical analysis and the effectiveness of the proposed DPWM method.

Low frequency plasma disinfectant effect in seawater and three major fish bacterial disease pathogens (저온 대기압 플라즈마를 이용한 해수 및 어류 병원성 세균 3종에 대한 살균소독효과)

  • Kim, Soo-Jin;Park, Shin-hoo;Jee, Bo-young;Kim, Yong-jae;Gwon, Mun-Gyoeng
    • Journal of fish pathology
    • /
    • v.33 no.1
    • /
    • pp.91-95
    • /
    • 2020
  • Fish bacterial diseases have spread and caused serious problem for cultured marine fish in Korea. The important bacterial disease affecting mariculture such as olive flounder (Paralichthys olivaceus) are caused by Edwardsiella tarda, Vibrio scophthalmi and Streptococcus parauberis. For the bacterial disease protection in aquaculture industry, the water treatment is needed in aquaculture system. During the last decades atmospheric pressure non-thermal plasma in contact with liquids have received a lot of attention of environmental and medical application. In this study, we determined the disinfectant effect in seawater and three major fish bacterial disease pathogens by using low frequency plasma treatment. Three fish bacteria (E. tarda, V. schophthalmi, S. parauberis) were not detected within 16 min, 150 min and 270 min of 20 L, 500 L and 1 ton seawater post low frequency plasma treatment, respectively. Three major fish bacterial disease pathogens were not detected within 2 min after the low frequency plasma treatment, suggesting that the low frequency plasma possess disinfectant effectiveness.