• Title/Summary/Keyword: loss variation

Search Result 1,226, Processing Time 0.025 seconds

Efficiency Optimization Control of IPMSM using Neural Network (신경회로망을 이용한 IPMSM의 효율 최적화 제어)

  • Chol, Jung-Sik;Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.1
    • /
    • pp.40-49
    • /
    • 2008
  • Interior permanent magnet synchronous motor(IPMSM) has become a popular choice in electric vehicle applications and so of due to their excellent power to weight ratio. To obtain maximum efficiency in these applications, this paper proposes the neural network control method. The controllable electrical loss which consists of the copper loss and the iron loss can be minimized by the error back propagation algorithm(EBPA) of neural network. The minimization of loss is possible to realize eHciency optimization control for the IPMSM drive. This paper proposes high performance and robust control through a real time calculation of parameter variation such as variation of back emf constant, armature resistance and d-axis inductance about the motor operation. Proposed algorithm is applied IPMSM drive system, prove validity through analysis operating characteristics con011ed by efficiency optimization control.

Coupling loss variation as the shape of fiber ends and the fiber arrangement in a fiber Fabry-Perot filter (광섬유 Fabry-Perot필터에서 광섬유 단면의 모양과 배치에 따른 결합손실 변화)

  • 김종호;예윤해
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.230-235
    • /
    • 1997
  • Coupling loss variation as the shape of fiber ends and the fiber arrangement in a fiber Fabry-Perot cavity, formed with two optical fibers with dielectric mirror coatings on their ends, is analyzed. For the intended features it is assumed that one of two fibers is processed to have a concave mirror whose curvature is the same as that of the wavefront of the Gaussian beam from the first fiber. In this assumption, it was turned out that the coupling loss at the cavity length of 15 ${\mu}{\textrm}{m}$ is less than 0.5% even with tilt angle of 0.2$^{\circ}$, curvature error of 70 ${\mu}{\textrm}{m}$, cavity length error of 8 ${\mu}{\textrm}{m}$, and lateral alignment error of 0.5 ${\mu}{\textrm}{m}$. Thus, low loss and high-finesse fiber Fabry-Perot filters whose cavity length is greater than several ${\mu}{\textrm}{m}$ can be obtained easily if the receiving fiber end is properly formed.

  • PDF

Design and Fabrication of DWDM Multiplexer Using Optical Fiber Biconical Tapered Couplers (광섬유 용융인장 방법에 의한 DWDM용 광다중화기의 제작)

  • Chang, Jin-Hyeon;Kim, Myoung-Saeng;Kang, Duk-Keun
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.3 no.2
    • /
    • pp.51-60
    • /
    • 2004
  • In this paper, 8-channel multiplexer with 100GHz channel spacing is fabricated. The 8-channel multiplexer is fabricated by connecting three cascaded Mach Zehnder Interferometer (MZI) of optical fiber type, and each interferometer has the wavelength interval of 100GHz, 200GHz and 400GHz, respectively. furthermore, to acquire uniform insertion loss, it is fabricated by using Wavelength Flatten Coupler (WFC) in which the variation of insertion loss is low. Especially, the variation of wavelength interval in the output is explicitly simulated as a function of optical path difference, and the wavelength coupling process along with cascaded connection is discussed. $CO_2$ laser to adjust precisely the wavelength. In summary, The prototype composed by eight cascaded MZI has an insertion loss of 2.1dB, the bandwidth of 0.8nm at 5.5dB point, and channel crosstalk of 25dB Furthermore, the loss dependent on polarization is measured as 0.06dB.

  • PDF

Study on variation of electrical characteristics of vertical PV module according to the change of irradiance and temperature (수직형 태양광발전모듈의 계절별 일사획득 및 온도변화에 따른 출력특성 변화에 관한 연구)

  • Park, Kyung-Eun;Kang, Gi-Hwan;Kim, Hyun-Il;Yu, Gwon-Jong;Kim, Jun-Tae
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.57-62
    • /
    • 2008
  • Building Integrated PV(BIPV) is one of the best fascinating PV application technologies. To apply PV module in building, various factors should be reflected such as installation position, shading, temperature, and so on. Especially the installation condition should be considered, for the generation performance of PV module is changed or the generation loss is appeared according to installation position, method, and etc. This study investigates variation of electrical characteristics of a PV module according to the change of irradiance and temperature. From this experimental study, we confirmed that the irradiance, the temperature variation and the generation performance of a PV module were appeared differently according seasonal variation. Actually the PV module installed in building facade showed high-generation performance in winter.

  • PDF

The Effect on Heat Loss Reduction in a refrigeration with the Variation of Gasket Shape (냉장고 가스켓 형상 변화에 따른 냉장고 열손실 저감 효과)

  • Ha, Ji-Soo;Jung, Kwang-Soo;Kim, Tae-Kwon;Kim, Kyung-Ho;Jeong, Gwan-Sik;Kim, Seok-Ro
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.286-291
    • /
    • 2008
  • Insulation of refrigerator with gasket material near door becomes the technical point at the aspect of heat loss and energy efficiency. Heat loss of refrigerator through the gasket is nearly 30%. In this paper, quantitative evaluation method of heat loss through gasket in established suggest the method for the improvement of heat loss. To analyze the heat transfer, we have used the common software Fluent that is used to CFD. Because of using the convection coefficient of heat transfer, we have solved only the equation of energy for heat transfer. As a result, we have known that heat loss flows through the heat flux vector and that the heat gathered out of the outside iron plate is transferred inner part through the gasket and ABS, etc. Through the result of the numerical simulation that use sub-gasket, we have known that we are able to reduce the heat loss about $20{\sim}40%$. when we applied that sub-gasket on a real refrigerator, the power consumption had reduced about 4.76%. In addition, when we applied a more improved sub-gasket on a real refrigerator and measured the power of the refrigerator the power consumption does reduce about 3% and we will try to apply the improved sub-gasket on a new models of refrigerator.

  • PDF

Measuring of Loss factor and Young's modulus of Plastics with Temperature Variation (온도변화에 따른 플라스틱의 손실계수와 Young 률의 측정)

  • Shin Su Hyun;Jung Sung Soo;Lee Yong Bong;Lee Doo Hee
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.321-322
    • /
    • 2004
  • It is well known that the loss factor and Young's modulus are fundamental mechanical properties of materials. In this study. the dynamic characteristics of plastics are evaluated by using two different standard test methods which are ASTM E 756 and ISO 6721. Polycarbonate and acrylonitrile butadiene styrene were used as test specimens. In order to evaluate vibration of damping properties with temperature, we measured loss factor and Young's modulus of the specimens the temperature range between $-10^{\circ}C$ and $60^{\circ}C$. The Young's modulus for polycarbonate decreased significantly as increasing temperature, while the loss factor increased. However, the Young's modulus and loss factor of acrylonitrile butadiene styrene are varied somewhat with temperature.

  • PDF

Performance Improvement of Packet Loss Concealment Algorithm in G.711 Using Speech Characteristics (음성 특성을 이용한 G.711 패킷 손실 은닉 알고리즘의 성능개선)

  • Han Seung-Ho;Kim Jin-Sul;Lee Hyun-Woo;Ryu Won;Hahn Min-Soo
    • MALSORI
    • /
    • no.57
    • /
    • pp.175-189
    • /
    • 2006
  • Because a packet loss brings about degradation of speech quality, VoIP speech coders have PLC (Packet Loss Concealment) mechanism. G.711, which is a mandatory VoIP speech coder, also has the PLC algorithm based on pitch period replication. However, it is not robust to burst losses. Thus, we propose two methods to improve the performance of the original PLC algorithm in G.711. One adaptively utilizes voiced/unvoiced information of adjacent good frames regarding to the current lost frame. The other is based on adaptive gain control according to energy variation across the frames. We evaluate the performance of the proposed PLC algorithm by measuring a PESQ value under different random and burst packet loss simulating conditions. It is shown from the experiments that the performance of the proposed PLC algorithm outperforms that of PLC employed in ITU-T Recommendation G.711.

  • PDF

The Effect of Ultrasonic Cavitation on the SS400 in Marine Sludge Oil (선박 슬러지유 환경에서 초음파 캐비테이션이 일반강에 미치는 영향)

  • Han Won-Hui
    • Tribology and Lubricants
    • /
    • v.22 no.4
    • /
    • pp.218-224
    • /
    • 2006
  • The sludge oils were produced necessarily in the ships operation, so that it will be the best way to manage the sludge oils inside ship itself from a viewpoint of the prevention of marine oil pollution. The ultra-sonic breaking system which recycle the sludge oil from ship into usable oil to be brunt is recognized as a most possible recycling device. In this regards, the purpose of this study is to examine erosion damage,on the SS400 specimen by cavitation and the effect of impact pressure generated from the demolition of the cavity of ultrasonic vibration in the marine sludge oil environment.. The erosion damage of specimen was investigated mainly on weight loss, weight loss rate and maximum erosion rate with variation of the oil temperature as well as the change of space between transducer hem and specimen. The experimental results showed that as the space between ultrasonic vibrator horn and specimen disk increased, the weight loss and weight loss rate decreased and the values were larger in SFO than in SLO. The experimental results can be useful to the development of sludge oil disposing systems and to consider a countermeasure for the prevention of erosion damages by cavitation.

Tip Gap Flow and Aerodynamic Loss Generation over a Cavity Squealer Tip with the Variation of Pressure-Side Opening Length in a Turbine Cascade (스퀼러팁의 압력면 개방길이 변화에 따른 터빈 익렬 팁간극 유동 특성 및 압력손실)

  • Cheon, Joo Hong;Lee, Sang Woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.6
    • /
    • pp.5-10
    • /
    • 2012
  • The effect of pressure-side opening length on three-dimensional flow fields and aerodynamic losses downstream of a cavity squealer tip has been investigated in a turbine rotor cascade for the squealer rim height-to-chord ratio and tip gap height-tochord ratio of $h_{st}/c$ = 5.05% and h/c = 2.0% respectively. The opening length-to-camber ratio is changed to be $OL/c_c$ = 0.0, 0.1, 0.2, 0.3, 0.4, 0.5, and 0.7 The results show that longer OL leads not only to weaker secondary flow but also to lower aerodynamic loss in the tip leakage vortex region, while it significantly widens the area with high aerodynamic loss in the passage vortex region. The aerodynamic loss coefficient mass-averaged all over the measurement plane is kept almost constant for $0.0{\leq}OL/c_c{\leq}0.3$, whereas it increases rapidly for $OL/c_c$ > 0.3 in proportion to $OL/c_c$. There is little deterioration in flow turning with increasing $OL/c_c$.

Variation of Pressure Loss and IPF Flowing Ice Slurry in Straight Tube Inclined to Various Angle (다양한 각도로 기울어진 직관내에서 아이스슬러리 유동시 압력손실과 IPF 변화)

  • Kim Kyu-Mok;Park Ki-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1028-1034
    • /
    • 2004
  • Recently, the ice storage system using ice slurry has been used increasingly since it has been introduced where the rapid cooling load change is required. Because it overcomes a decrease of the melting performance and an increase of the thermal resistance on the ice layer in static ice thermal storage system. This study is performed to understand the effects of transporting ice slurry through horizontal, vertical and inclined tubes ($30^{\circ},\;45^{\circ}$). It used propylene glycol-water solution and ice particles (diameter of about 2 mm) in this experiment. The experiments were carried out under various conditions, with concentration of water solution ranging from 0 to $20wt\%$, and velocity of water solution at the entry ranging from 1.5 to 2.5 m/s. The results were as follows: Regarding the angle of inclined tube, the highest pressure loss was measured for vertical tube and the pressure loss for $45^{\circ},\;30^{\circ}$, horizontal straight tubes were lower successively. The lowest pressure loss in these tubes was measured at velocity of $2.0{\sim}2.5m/s$ and concentration of $10wt\%$. The outlet IPF was likewise stable in these ranges.