The Effect on Heat Loss Reduction in a refrigeration with the Variation of Gasket Shape

냉장고 가스켓 형상 변화에 따른 냉장고 열손실 저감 효과

  • 하지수 (계명대학교 에너지환경과학과) ;
  • 정광수 (계명대학교 에너지환경과학과) ;
  • 김태권 (계명대학교 기계자동차공학부) ;
  • 김경호 (계명대학교 저공해자동차부품연구센터) ;
  • 정관식 (LG전자) ;
  • 김석로 (LG전자)
  • Published : 2008.11.21

Abstract

Insulation of refrigerator with gasket material near door becomes the technical point at the aspect of heat loss and energy efficiency. Heat loss of refrigerator through the gasket is nearly 30%. In this paper, quantitative evaluation method of heat loss through gasket in established suggest the method for the improvement of heat loss. To analyze the heat transfer, we have used the common software Fluent that is used to CFD. Because of using the convection coefficient of heat transfer, we have solved only the equation of energy for heat transfer. As a result, we have known that heat loss flows through the heat flux vector and that the heat gathered out of the outside iron plate is transferred inner part through the gasket and ABS, etc. Through the result of the numerical simulation that use sub-gasket, we have known that we are able to reduce the heat loss about $20{\sim}40%$. when we applied that sub-gasket on a real refrigerator, the power consumption had reduced about 4.76%. In addition, when we applied a more improved sub-gasket on a real refrigerator and measured the power of the refrigerator the power consumption does reduce about 3% and we will try to apply the improved sub-gasket on a new models of refrigerator.

Keywords