• Title/Summary/Keyword: loss of resistance technique

Search Result 84, Processing Time 0.023 seconds

Development of BGA Interconnection Process Using Solderable Anisotropic Conductive Adhesives (Solderable 이방성 도전성 접착제를 이용한 BGA 접합공정 개발)

  • Yim, Byung-Seung;Lee, Jeong Il;Oh, Seung Hoon;Chae, Jong-Yi;Hwang, Min Sub;Kim, Jong-Min
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.4
    • /
    • pp.10-15
    • /
    • 2016
  • In this paper, novel ball grid array (BGA) interconnection process using solderable anisotropic conductive adhesives (SACAs) with low-melting-point alloy (LMPA) fillers have been developed to enhance the processability in the conventional capillary underfill technique and to overcome the limitations in the no-flow underfill technique. To confirm the feasibility of the proposed technique, BGA interconnection test was performed using two types of SACA with different LMPA concentration (0 and 4 vol%). After the interconnection process, the interconnection characteristics such as morphology of conduction path and electrical properties of BGA assemblies were inspected and compared. The results indicated that BGA assemblies using SACA without LMPA fillers showed weak conduction path formation such as solder bump loss or short circuit formation because of the expansion of air bubbles within the interconnection area due to the relatively high reflow peak temperature. Meanwhile, assemblies using SACA with 4 vol% LMPAs showed stable metallurgical interconnection formation and electrical resistance due to the favorable selective wetting behavior of molten LMPAs for the solder bump and Cu metallization.

A Read-In Integrated Circuit for IR Scene Projectors Adopting a Sub-Frame Control Technique for Minimizing the Temperature Loss (온도 손실의 최소화를 위해 Sub-Frame 제어 기법을 적용한 적외선 영상 투사기용 신호입력회로)

  • Shin, Uisub;Cho, Min Ji;Kang, Woo Jin;Jo, Young Min;Lee, Hee Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.113-118
    • /
    • 2016
  • In this paper, a read-in integrated circuit (RIIC) for IR scene projectors (IRSPs) adopting a sub-frame control technique is proposed, which minimizes the reduction of the apparent temperature of the IR images projected from IRSPs operating at a frame rate of 30 Hz. The proposed sub-frame control technique significantly reduces the amount of scene data loss on capacitors, which is caused by leakage currents flowing through MOSFET switches during holding periods, by dividing a unit frame into 8 sub-frames and refreshing the same scene data for each sub-frame. A current-drive RIIC was designed for the higher apparent temperature of IR radiated from the emitter, and it receives the scene data as a form of analog voltages from an external DAC. A prototype chip with a $64{\times}32$ RIIC array was fabricated using Magnachip/SKhynix $0.35{\mu}m$ 2-poly 4-metal CMOS process, and the measured maximum output data current is $230.3{\mu}A$. This amount of current ensures the projection of IR images whose maximum apparent temperature is $366.2^{\circ}C$ in the mid-wavelength IR (MWIR) when applied to a prototype emitter having a resistance of $15k{\Omega}$.

Fabrication and Characteristics of $Al_2O_{3p}$/AC8A Composites by Pressureless Infiltration Process (무가압함침법에 의한 $Al_2O_{3p}$/AC8A 복합재료의 제조 및 특성)

  • 김재동;고성위;정해용
    • Composites Research
    • /
    • v.13 no.6
    • /
    • pp.1-8
    • /
    • 2000
  • The fabrication Process of $Al_2O_{3p}$/AC8A composites by pressureless infiltration technique and the effects of additive Mg content and volume fraction of particulate reinforcement on mechanical and wear properties were investigated. It was found that the bending strength decreased with increasing volume fraction of $Al_2O_{3p}$ particles. Whereas hardness increased with volume fraction of $Al_2O_{3p}$ particles. The decrement of strength in case of high volume fraction of $Al_2O_{3p}$ particles was attributed to high porosity level. In terms of additive Mg content, $Al_2O_{3p}$/AC8A composites containing around 5~7wt% of additive Mg indicated the highest strength, and hardness values increased with additive Mg contents. Wear resistance of AC8A alloy were improved by reinforcement of $Al_2O_{3p}$ particles especially at high sliding velocity. Wear property of $Al_2O_{3p}$/AC8A composites and AC8A alloy exhibited different aspects. $Al_2O_{3p}$/AC8A composites indicated more wear loss than AC8A alloy at slow velocity region. However a transition point of wear loss was found at middle velocity region which shows the minimum wear loss and wear loss at high velocity region exhibited almost same value as at slow velocity region, whereas wear loss of AC8A alloy almost linearly increased with sliding velocity. It was found that $Al_2O_{3p}$/AC8A composites containing $Al_2O_{3p}$ volume fraction of 20% exhibited abrasive wear surface regardless of sliding velocity and $Al_2O_{3p}$/AC8A composites containing $Al_2O_{3p}$ volume fraction of 40% showed slightly adhesive wear surface at low sliding velocity, and it progressed to severe wear as increasing the sliding velocity.

  • PDF

Evaluation of 475 ℃ embrittlement in UNS S32750 super duplex stainless steel using four-point electric conductivity measurements

  • Gutierrez-Vargas, Gildardo;Ruiz, Alberto;Lopez-Morelos, Victor H.;Kim, Jin-Yeon;Gonzalez-Sanchez, Jorge;Medina-Flores, Ariosto
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2982-2989
    • /
    • 2021
  • One of the consequences of the 475 ℃ embrittlement of duplex stainless steels is the reduction of the resistance to localized corrosion. Therefore, the detection of this type of embrittlement before the material exhibits significant loss in toughness, and corrosion resistance is important to ensure the structural integrity of critical components under corrosion threats. In this research, conductivity measurements are performed using the alternating current potential drop (ACPD) technique with using a portable four-point probe as a nondestructive evaluation (NDE) method for detecting the embrittlement in a 2507 (UNS S32750) super duplex stainless steel (SDSS) aged at 475 ℃ from as-received condition to 300 h. The electric conductivity results were compared against two electrochemical tests namely double loop electrochemical potentiokinetic reactivation (DL-EPR) and critical pitting temperature (CPT). Mechanical tests and the microstructure characterized using scanning electron microscopy (SEM) imaging are conducted to track the progress of embrittlement. It is shown that the electric conductivity correlates with the changes in impact energy, microhardness, and CPT corrosion tests result demonstrating the feasibility of the four-point probe as a possible field-deployable method for evaluating the 475 ℃ embrittlement of 2507 SDSS.

An Alternative Approach to Needle Placement in Cervicothoracic Epidural Injections

  • Park, Seung-Yong;Leem, Jung-Gil;Jung, Sung-Hwan;Kim, Young-Ki;Koh, Won-Uk
    • The Korean Journal of Pain
    • /
    • v.25 no.3
    • /
    • pp.183-187
    • /
    • 2012
  • The use of fluoroscopy guidance together with the loss of resistance technique during epidural injections has been advocated lately; moreover, epidural injections in the absence of fluoroscopic guidance have a high rate of inaccurate needle-tip placement during the injections. However, the approach to the lower cervical and upper thoracic epidural space may be challenging due to its obscure lateral fluoroscopic views from overlying normal tissue structures. In this case, we report an alternative oblique C-arm fluoroscopy guided view approach to supplement the standard anterior-posterior and lateral fluoroscopic views to facilitate successful needle placement and precise anatomical localization of the epidural space.

Study on the Wear Resistance of Gray Cast Iron in Laser Surface Hardening (레이저 표면경화처리된 회주철의 내마모특성에 관한 연구)

  • Park, K.W.;Han, Y.H.;Lee, S.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.9 no.4
    • /
    • pp.271-280
    • /
    • 1996
  • This study has been performed to investigate into some effects of power density and traverse speed of laser beam on optical microstructure, hardness and wear characteristics of gray cast iron treated by laser surface hardening technique. Optical micrograph has shown that large martensite and a small amount of retained austenite appear in outermost surface layer with fine martensite in inside hardened zone. Hardness measurements have revealed that the range of maximun hardness value is $Hv=650{\pm}15$ and as the power density increases and the traverse speed decreses, the depth of hardened zone increases due to as increase in input power density. Wear test has exhibited that wear rasistance of laser surface hardened specimen is superier compared to that of untreated specimen under the condition of same load at a given sliding distance, showing that absorption results of an wxidized substance due to a heavy abrasion appear in untreated specimen. The amount of weight loss of laser surface hardened specimen with respect to sliding distance at a given load decreses with increasing traverse speed at a given power density and with increasing power density at a given traverse speed.

  • PDF

A Study on the Method of Residents-Participatory Design for Apartment Housing Remodeling (공동주택 주호개수를 위한 거주자 참여 디자인 수법에 관한 사례연구)

  • Yi, Yong-Kyu
    • Journal of the Korean housing association
    • /
    • v.24 no.4
    • /
    • pp.53-60
    • /
    • 2013
  • Apartments amount to 58.3%, the highest proportion of domestic housing types. These apartments' lifespan (approximately 27 years) are one-third of the developed countries' housing lifespan due to the property developers and mass production. It is significantly short-cycle period considering the original physical lifespan of the apartment housing are 60 years. It has caused economic loss and environmental degradation. In recent years, research and development for the long life of the apartment housing has been actively performed, but it is limited on reconstruction and new construction. Reconstruction of existing a number of high-rise apartments is difficult owing to restrictions on the floor area ratio allowing for 40 years limit of decay resistance after the completion. Improving lifespan of the building has recently begun to receive attention as an alternative to remodeling. However, These sort of remodeling techniques tend to be focused on technology developed for the physical life extension. That means developing the techniques about dwelling-unit environment for residents satisfaction are required as well as improving physical construction. The purpose of this study is to propose and verify the Participatory Design Technique which can help the residents as the active participation in the design decision-making process.

Producing synthetic lightweight aggregates by treating waste TFT-LCD glass powder and reservoir sediments

  • Tang, Chao-Wei
    • Computers and Concrete
    • /
    • v.13 no.3
    • /
    • pp.325-342
    • /
    • 2014
  • The use of lightweight aggregate (LWA) instead of ordinary aggregate may make lightweight aggregate concrete, which possesses many advantages such as lightweight, lower thermal conductivity, and better fire and seismic resistance. Recently the developments of LWA have been focused on using industrial wastes as raw materials to reduce the use of limited natural resources. In view of this, the intent of this study was to apply Taguchi optimization technique in determining process condition for producing synthetic LWA by incorporating waste thin film transition liquid crystal displays (TFT-LCD) glass powder with reservoir sediments. In the study the waste TFT-LCD glass cullet was used as an additive. It was incorporated with reservoir sediments to produce LWA. Taguchi method with an orthogonal array L16(45) and five controllable 4-level factors (i.e., cullet content, preheat temperature, preheat time, sintering temperature, and sintering time) was adopted. Then, in order to optimize the selected parameters, the analysis of variance method was used to explore the effects of the experimental factors on the performances (particle density, water absorption, bloating ratio, and loss of ignition) of the produced LWA. The results showed that it is possible to produce high performance LWA by incorporating waste TFT-LCD glass cullet with reservoir sediments. Moreover, Taguchi method is a promising approach for optimizing process condition of synthetic LWA using recycled glass cullet and reservoir sediments and it significantly reduces the number of tests.

A Study on the Technique to Stabilize a Device with Minimum Degradation of Performances (특성 저하를 최소화하는 광대역 안정화 기법에 관한 연구)

  • Chung, Myung-Rea;Lee, Sang-Won;Kim, Hak-Sun;Hong, Shin-Nam;Lee, Yun-Hyun
    • Journal of Advanced Navigation Technology
    • /
    • v.3 no.2
    • /
    • pp.174-184
    • /
    • 1999
  • In this paper, the equations which can be used to calculate the minimum series stabilizing resistance and /or the minimum parallel stabilizing conductance using the S parameters of an active device has been derived. The equation derived can be used to design a stabilizing circuit of minimum loss of a maximum available gain of a device when the circuit is adopted. For the case of KGF1254B which can be used at 1.9 GHz, the circuit proposed in this paper reduce the maximum available gain by 1 dB, while conventional simple resistor circuit reduce it by 5.2 dB.

  • PDF

Delayed Pneumocephalus Following Fluoroscopy Guided Cervical Interlaminar Epidural Steroid Injection : A Rare Complication and Anatomical Considerations

  • Kim, Yeon-Dong;Ham, Hyang-Do;Moon, Hyun-Seog;Kim, Soo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.5
    • /
    • pp.376-378
    • /
    • 2015
  • Cervical epidural steroid injection is indicated for radicular symptoms with or without axial neck pain. Complications are rare but can be serious. Here, we report the case of a 54-year-old man with cervical radicular pain who was treated with cervical epidural steroid injection. Injection was administered twice under fluoroscopic guidance with the loss-of-resistance technique using air to confirm the epidural space. After the second procedure, the patient complained of severe persistent headache and was diagnosed with pneumocephalus on brain computed tomography. The patient returned home without any neurological complication, after a few days of conservative treatment. Though, a fluoroscopic guidance cervical epidural injection is also known to diminish the risk of complications. Physicians should always keep in mind that it does not guarantee safety, particularly in the cervical region, related to its anatomical considerations.