• 제목/요약/키워드: locating

검색결과 881건 처리시간 0.027초

A baseline free method for locating imperfect bolted joints

  • Soleimanpour, Reza;Soleimani, Sayed Mohamad;Salem, Mariam Naser Sulaiman
    • Structural Monitoring and Maintenance
    • /
    • 제9권3호
    • /
    • pp.237-258
    • /
    • 2022
  • This paper studies detecting and locating loose bolts using nonlinear guided waves. The 3D Finite Element (FE) simulation is used for the prediction of guided waves' interactions with loose bolted joints. The numerical results are verified by experimentally obtained data. The study considers bolted joints consisting of two bolts. It is shown that the guided waves' interaction with surfaces of a loose bolted joint generates Contact Acoustic Nonlinearity (CAN). The study uses CAN for detecting and locating loose bolts. The processed experimentally obtained data show that the CAN is able to successfully detect and locate loose bolted joints. A 3D FE simulation scheme is developed and validated by experimentally obtained data. It is shown that FE can predict the propagation of guided waves in loose bolts and is also able to detect and locate them. Several numerical case studies with various bolt sizes are created and studied using the validated 3D FE simulation approach. It is shown that the FE simulation modeling approach and the signal processing scheme used in the current study are able to detect and locate the loose bolts in imperfect bolted joints. The outcomes of this research can provide better insights into understanding the interaction of guided waves with loose bolts. The results can also enhance the maintenance and repair of imperfect joints using the nonlinear guided waves technique.

Topological Locating of Power Quality Event Source

  • Won Dong-Jun;Moon Seung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권2호
    • /
    • pp.170-176
    • /
    • 2006
  • This paper proposes a topological locating algorithm to determine the location of the power quality event source. This algorithm makes use of the information on the topology of the monitored network and on the direction of PQ events. As a result, the bus incidence matrix is modified using monitor location and the direction matrix is constructed. With this information, the algorithm determines the suspected locations of the PQ events. To reduce suspicious areas, it utilizes event cause and related equipment. In case of line fault event, it calculates the distance from the monitor to the location of event source. The overall algorithm is applied to the IEEE test feeder and accurately identifies the event source location.

A Combined Approach for Locating Box H/ACA snoRNAs in the Human Genome

  • Eo, Hae Seok;Jo, Kwang Sun;Lee, Seung Won;Kim, Chang-Bae;Kim, Won
    • Molecules and Cells
    • /
    • 제20권1호
    • /
    • pp.35-42
    • /
    • 2005
  • A novel combined method for locating box H/ACA small nucleolar RNAs (snoRNAs) is described, together with a software tool. The method adopts both a probabilistic hidden Markov model (HMM) and a minimum free energy (MFE) rule, and filters possible candidate box H/ACA snoRNAs obtained from genomic DNA sequences. With our novel method 12 known box H/ACA snoRNAs, and one strong candidate were identified in 30 nucleolar protein genomic sequences.

중소제조업체의 측정기 운영에 관한 실증적 연구 - 검사 지그를 중심으로 - (A Study on Management for Measuring Instrument of Small and Medium-sized Enterprises - Focusing on the Inspection Gig -)

  • 유현종;정수일
    • 대한안전경영과학회지
    • /
    • 제10권2호
    • /
    • pp.217-223
    • /
    • 2008
  • Measurement is used for evaluation of product or process exactly. If it couldn't measured correctly, Quality-cost must be raised and it would be hard to improve product quality. So, this study suggests improvement guide line for the multilateral problems of measuring instrument operation based on the investigation of 157 small and medium-sized enterprises in February, 2008. To use inspection gig correctly, man who treat it must be accustomed with the structure, the performance, the method. The inspection gig is selected properly for the measurement goal. If not, results couldn't be correctly or wasted time, efforts, and costs. When selecting a inspection gig, the locating, the clamping, and the efficiency must be considered.

Locating Destination Address Block On Thai Envelopes

  • Chanpongsae, Worapote;Kumhom, Pinti;Chamnongthai, Kosin
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.192-195
    • /
    • 2002
  • About 90% of Thai-style addresses have similar features; e.g. the beginning of each address line is diagonal. In this paper, we propose a method for locating destination address block (DAB) on Thai envelopes based on features of Thai-style addresses. Firstly, we decompose image into smaller blocks and remove all blocks not meeting criteria. Secondly, we search for the DAB candidates. Lastly, heuristic rules and typical features are applied to identify the destination address block. Experimental results using 2,700 envelopes of handwritten and machine printed Thai envelopes show a successful address extraction rate of 91%.

  • PDF

Impact Localization for a Composite Plate Using the Spatial Focusing Properties of Advanced Signal Processing Techniques

  • Jeong, Hyunjo;Cho, Sungjong
    • 비파괴검사학회지
    • /
    • 제32권6호
    • /
    • pp.703-710
    • /
    • 2012
  • A structural health monitoring technique for locating impact position in a composite plate is presented in this paper. The method employs a single sensor and spatial focusing properties of time reversal(TR) and inverse filtering(IF). We first examine the spatial focusing efficiency of both approaches at the impact position and its surroundings through impact experiments. The imaging results of impact localization show that the impact location can be accurately estimated in any position of the plate. Compared to existing techniques for locating impact or acoustic emission source, the proposed method has the benefits of using a single sensor and not requiring knowledge of anisotropic material properties and geometry of structures. Furthermore, it does not depend on a particular mode of dispersive Lamb waves that is frequently used in other ultrasonic testing of plate-like structures.

초음파 신호측정에 의한 변압기내의 부분방전위치측정 (The decision of position of a partial discharge in power transformer by measurement of ultra sonic signal)

  • 문영재
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1992년도 학술논문발표회 논문집 제11권 1호
    • /
    • pp.87-90
    • /
    • 1992
  • Detecting acoustic emission (AE) provides an appropriate method to diagonize on-line transformers, since acoustic signal is not influenced by strong electric field. Then AE versus AE signal processing method is investigated. But this processing is difficult that decision of starting point of AE wave with acoustic noise. This problem is sloved by correlation which calculate time interval between two signals eactly. This paper presents a technique locating the eact position of the partial discharge (PD) in a power transformer by the correlation of the AE signals from two ultrasonic sensors. And PD position is displayed on monitor. Laboratory tests confirmed that the proposed method can be used for locating the PD in power transformer.

  • PDF

전력 설비 감시를 위한 무선 센서 (Wireless Sensor for Diagnostics of Electric Equipments)

  • 최용성;김형곤;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.98-102
    • /
    • 2008
  • Methods and analysis of a simple wireless sensor concept for detecting and locating faults as well as for load monitoring are presented. The concept is based on distributed wireless sensors that are attached to the incoming and outgoing power lines of secondary substations. A sensor measures only phase current characteristics of the wire it is attached to, is not synchronized to other sensors and does not need configuration of triggering levels. The main novelty of the concept is in detecting and locating faults by combining power distribution network characteristics on system level with low power sampling methods for individual sensors. This concept enables the sensor design to be simple, energy efficient and thus applicable in new installations and for retrofit purposes in both overhead and underground electrical distribution systems.

  • PDF