Abstract
This paper proposes a topological locating algorithm to determine the location of the power quality event source. This algorithm makes use of the information on the topology of the monitored network and on the direction of PQ events. As a result, the bus incidence matrix is modified using monitor location and the direction matrix is constructed. With this information, the algorithm determines the suspected locations of the PQ events. To reduce suspicious areas, it utilizes event cause and related equipment. In case of line fault event, it calculates the distance from the monitor to the location of event source. The overall algorithm is applied to the IEEE test feeder and accurately identifies the event source location.
Keywords
distribution system; event; fault; harmonics; monitoring; power quality; sag;
Citations & Related Records
연도 인용수 순위
  • Reference
1 L. Cristaldi, A. Ferrero, S. Salicone, 'A Distributed System for Electric Power Quality Measurement,' IEEE Transactions on Instrumentation and Measurement, vol. 51, no. 4, pp. 776 -781, Aug. 2002   DOI   ScienceOn
2 Glenn W. stagg, Ahmed H. El-Abiad, Computer methods in power systems analysis, New York: Mcgraw-Hill, Inc., 1968
3 Mark Allen Weiss, Data Structures & Problem Solving using JAVATM, 2nd ed., Addison Wesley, Inc., 2002, pp. 570
4 Distribution System Analysis Subcommittee Report, Radial Distribution Test Feeders, http://ewh.ieee.org/ soc/pes/dsacom/testfeeders.html
5 Mark McGranaghan, 'Trends in Power Quality Monitoring,' IEEE Power Engineering Review, vol. 21, Issue 10, pp. 3-9,21, Oct. 2001
6 G. T. Heydt, 'Identification of Harmonic Sources by a State Estimation Technique,' IEEE Trans. Power Delivery, vol. 4, no. 1, pp. 569-576, Jan. 1989   DOI   ScienceOn
7 Astrat Teshome, 'Harmonic Source and Type Identification in a Radial Distribution System,' Conference Record of the 1991 IEEE Industrial Applications Society Annual Meeting, vol. 2, pp. 1605-1609, 1991
8 Anthony C. Parsons, W. Mack Grady, Edward J. Powers, John C. Soward, 'Rules for Locating the Sources of Capacitor Switching Disturbances,' IEEE Power Engineering Society Summer Meeting, vol. 2, pp. 794-799, 1999
9 Anthony C. Parsons, W. Mack Grady, Edward J. Powers, John C. Soward, 'A Direction Finder for Power Quality Disturbances Based Upon Disturbance Power and Energy,' IEEE Trans. Power Delively, vol. 15, no. 3, pp. 1081-1086, July 2000
10 Ben Byman, Tom Yarborough, Rudolf Schnorr von Carolsfeld, John Van Gorp, 'Using Distributed Power Quality Monitoring for Better Electrical System Management,' IEEE Transactions on Industvy Applications, vol. 36, no. 5, pp. 1481-1485, Sep.-Oct. 2000   DOI   ScienceOn