• Title/Summary/Keyword: loading level

Search Result 1,190, Processing Time 0.032 seconds

The Effect of the Attached Growth in Aerobic Reactor on Nitrogen Removal in A2/O processes (포기조에 충진된 고정상 담체가 A2/O공정에서 질소제거에 미치는 영향)

  • Whang, Gye-Dae;Bae, Sung-Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1022-1030
    • /
    • 2006
  • Activated sludge reactors maintaining an MLSS of 3,000 mg/L and packed Bio Contact Media (BCM fixed beds) was studied in lab-scale to determine the optimal packing ratio and an HRT of aerobic reactor in terms of organic removal, nitrification, denitrification efficiencies. At all HRTs of 3 hr, 5 hr, 7 hr respectively, reactors without BCM, control reactors, had the lowest TCODcr removal efficiency about 74.6%, and reactors with the BCM packing ratios of 10%, 15%, 20% had a greater TCODcr removal efficiency above 81.4%. As HRT decreased, the TCODcr removal efficiency decreased also in all reactors. However, a better utilization of TCODcr even at a higher organic loading was observed in reactors with BCM. The nitrification efficiency at all reactors was greater than 94%, and reactor with 20% packing of BCM had the highest nitrification efficiency at 97.9% while the TKN loading increased at $0.085mgTKN/m^3{\ast}day$ as HRT decreased, In terms of denitrification efficiency, the reactor without BCM ranged from 11.6% to 13.7%, and the reactors with BCM ranged from 28.3% to 63.4% which suggests that the more BCM is packed in the reactors, the higher the denitrification efficiency is achieved. Two parallel $A^2/O$ systems maintaining an MLSS of 3,000 mg/L were operated to investigate the effect of BCM packing ratio of 20% on organic removal, nitrification, denitrification efficiencies. Packing with BCM in system of aerobic reactor affected the SCODcr removal efficiency that increased from 73% to 78%. The nitrification efficiency for both systems with or without BCM was greater than 95%. The denitrification efficiency of systems with BCM and without BCM was 85.8% and 81.8%, respectively which appears that the denitrification efficiency was increased slightly by packing BCM. Compared denitrification efficiency in $A^2/O$ system to previous experimental study with activated sludge reactors operates with the same HRT $A^2/O$ system showed only 29% greater denitrification efficiency. It suggests that $A^2/O$ system with BCM can achieve a similar level of denitrification efficiency when the HRT of anoxic reactor is decreased to some extent.

Earthquake-Resistant Design of Cantilever Retaining-Walls with Sloped Base (기초슬래브의 밑면이 경사진 캔티레바식 옹벽의 내진설계)

  • Kim, Hong Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.87-98
    • /
    • 1990
  • The present Study dealt with the earthquake-resistant design of cantilever retaining walls supporting cohesionless soils. With design examples of three different types of cantilever retaining walls, the factors of safety against sliding were computed at various values of horizontal acceleration coefficient and compared with each other. The horizontal inertia effect due to the weights of concrete wall itself and a portion of backfill was taken into account in the analyses, and also Mononobe-Okabe pseudo-static solution method was modified to deal with various states different from limiting equilibrium state. From the analyses of safety against sliding, it was found that a cantilever retaining wall with sloped base was the most efficient type in earthquake resistant design. It was also found that by sloping the base, the width of the base slab could be reduced, resulting in the least volume of concrete, excavation and backfill as compared to the other types of walls. In the case of a cantilever retaining wall with sloped feel, the efficiency similar to that of a wall with sloped base could be expected under static loading as well as at relatively low level of earthquake loading. However, this efficiency became vanished with the increase of horizontal acceleration coefficient, since the rate of reduction in developed earth pressures on the heel became smaller. In addition, the design charts with different soil friction angles as well as with different earthquake resistant design criteria of safety factor against sliding were presented for the design of cantilever retaining walls sith sloped base.

  • PDF

Nitrogen Removal from Milking Center Wastewater via Simultaneous Nitrification and Denitrification Using a Biofilm Filtration Reactor

  • Won, Seung-Gun;Jeon, Dae-Yong;Kwag, Jung-Hoon;Kim, Jeong-Dae;Ra, Chang-Six
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.6
    • /
    • pp.896-902
    • /
    • 2015
  • Milking center wastewater (MCW) has a relatively low ratio of carbon to nitrogen (C/N ratio), which should be separately managed from livestock manure due to the negative impacts of manure nutrients and harmful effects on down-stream in the livestock manure process with respect to the microbial growth. Simultaneous nitrification and denitrification (SND) is linked to inhibition of the second nitrification and reduces around 40% of the carbonaceous energy available for denitrification. Thus, this study was conducted to find the optimal operational conditions for the treatment of MCW using an attached-growth biofilm reactor; i.e., nitrogen loading rate (NLR) of 0.14, 0.28, 0.43, and $0.58kg\;m^{-3}\;d^{-1}$ and aeration rate of 0.06, 0.12, and $0.24\;m^3\;h^{-1}$ were evaluated and the comparison of air-diffuser position between one-third and bottom of the reactor was conducted. Four sand packed-bed reactors with the effective volume of 2.5 L were prepared and initially an air-diffuser was placed at one third from the bottom of the reactor. After the adaptation period of 2 weeks, SND was observed at all four reactors and the optimal NLR of $0.45kg\;m^{-3}\;d^{-1}$ was found as a threshold value to obtain higher nitrogen removal efficiency. Dissolved oxygen (DO) as one of key operational conditions was measured during the experiment and the reactor with an aeration rate of $0.12\;m^3\;h^{-1}$ showed the best performance of $NH_4-N$ removal and the higher total nitrogen removal efficiency through SND with appropriate DO level of ${\sim}0.5\;mg\;DO\;L^{-1}$. The air-diffuser position at one third from the bottom of the reactor resulted in better nitrogen removal than at the bottom position. Consequently, nitrogen in MCW with a low C/N ratio of 2.15 was successfully removed without the addition of external carbon sources.

Robust Design for Showerhead Thermal Deformation

  • Gong, Dae-Wi;Kim, Ho-Jun;Lee, Seung-Mu;Won, Je-Hyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.150.1-150.1
    • /
    • 2014
  • Showerhead is used as a main part in the semiconductor equipment. The face plate flatness should remain constant and the cleaning performance must be gained to keep the uniformity level of etching or deposition in chemical vapor deposition process. High operating temperature or long period of thermal loading could lead the showerhead to be deformed thermally. In some case, the thermal deformation appears very sensitive to showerhead performance. This paper describes the methods for robust design using computational fluid dynamics. To reveal the influence of the post distribution on flow pattern in the showerhead cavity, numerical simulation was performed for several post distributions. The flow structure appears similar to an impinging flow near a centered baffle in showerhead cavity. We took the structure as an index to estimate diffusion path. A robust design to reduce the thermal deformation of showerhead can be achieved using post number increase without ill effect on flow. To prevent the showerhead deformation by heat loading, its face plate thickness was determined additionally using numerical simulation. The face plate has thousands of impinging holes. The design key is to keep pressure drop distribution on the showerhead face plate with the holes. This study reads the methodology to apply to a showerhead hole design. A Hagen-Poiseuille equation gives the pressure drop in a fluid flowing through such hole. The assumptions of the equation are the fluid is viscous-incompressible and the flow is laminar fully developed in a through hole. An equation can be expressed with radius R and length L related to the volume flow rate Q from the Hagen-Poiseuille equation, $Q={\pi}R4{\Delta}p/8{\mu}L$, where ${\mu}$ is the viscosity and ${\Delta}p$ is the pressure drop. In present case, each hole has steps at both the inlet and the outlet, and the fluid appears compressible. So we simplify the equation as $Q=C(R,L){\Delta}p$. A series of performance curves for a through hole with geometric parameters were obtained using two-dimensional numerical simulation. We obtained a relation between the hole diameter and hole length from the test cases to determine hole diameter at fixed hole length. A numerical simulation has been performed as a tool for enhancing showerhead robust design from flow structure. Geometric parameters for the design were post distribution and face plate thickness. The reinforced showerhead has been installed and its effective deposition profile is being shown in factory.

  • PDF

A Study on the Operational Variables of the UV-TiO$_2$ Based Photocatalytic Air Cleaning System (UV-TiO$_2$ 광촉매 기반의 공기 정화 시스템의 운전조건에 대한 연구)

  • Han, Chang-Seok;Chang, Hyuk-Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.3
    • /
    • pp.293-301
    • /
    • 2008
  • A study on the operational variables of the UV-TiO$_2$ based photocatalytic air cleaning system was tried. In this study, to examine effects as various air cleaning system conditions, a duct-type reactor was made, and TiO$_2$ was immobilized on a stainless mesh. Benzene was chosen as a target compound. Removal experiments for benzene were done under different initial benzene concentration, air velocity, TiO$_2$ loading, area coated TiO$_2$ as the same TiO$_2$ loading, and UV light intensity conditions. During the experiments, relative humidity was 55%, and reactor temperature was 45$^{\circ}C$. As a result, the photocatalytic degradation of benzene decreased as the inlet concentration increased. But the photocatalytic degradation increased as the concentration boundary layer thickness, amount of TiO$_2$, area coated TiO$_2$ as the same amount of TiO$_2$, and UV light intensity increased. Based on results of current study, they can be applied to the design of air cleaning system over low level VOCs in the indoor air.

Efficacy of Epidural Metoclopramide in Reducing Nausea and Vomiting Associated with Postoperative Epidural Morphine (술후 경막외 Morphine으로 인한 오심 및 구토에 대한 경막외 Metoclopramide의 효과)

  • Park, Jin-Woo;Im, Dae-Guen;Jung, Sun-Ho;Choe, Young-Kyun;Kim, Young-Jae;Shin, Chee-Mahn;Pak, Myoung;Park, Ju-Yuel
    • The Korean Journal of Pain
    • /
    • v.10 no.2
    • /
    • pp.203-207
    • /
    • 1997
  • Background: To date, there are no controlled studies assessing the effect of metoclopramide administered epidurally to prevent nausea and vomiting associated with epidural morphine for postoperative analgesia. This study was undertaken to determine the effectiveness of continuous epidural infusion of metoclopramide, combined with epidural morphine, in reducing nausea or vomiting associated with epidural morphine and minimizing the side effects of metoclopramide. Methods: Sixty patients undergoing elective gynecologic surgery were randomly assigned to one of two study groups. Patients received continuous epidural morphine infusion (6.0 mg/day) following a bolus loading dose of 3.0 mg (Group A), or epidural mixture of morphine (6.0 mg/day) plus metoclopramide (20 mg/day) following a bolus loading dose (morphine 3.0 mg, metoclopramide 10 mg)(Group B). For the first 24 postoperative hours, incidence of nausea or vomiting, need for antiemetic therapy, level of sedation, degree of pain and pruritus, and adverse effects associated with metoclopramide were evaluated. Result: Incidence of nausea or vomiting and number of patients who required antiemetic therapy were significantly less in Group B, than in Group A (P<0.05). There were no significant differences between groups with regard to adverse effects associated with metoclopramide such as sedation, extrapyramidal reaction and other side effects (P=NS). Conclusion: We conclude simultaneous titration of morphine and metoclopramide via epidural continuous infusion following epidural bolus injection of the mixture reduces nausea or vomiting associated with epidural morphine while preventing side effects of metoclopramide.

  • PDF

The Study of noise and vibration on application of the method breaking & excavating rock(Super wedge) (암파쇄굴착공법(Super wedge) 적용에 따른 소음.진동에 대한 고찰)

  • Won, Yeon-Ho;Kang, Choo-Won;Ryu, Chang-Ha
    • Proceedings of the KSEE Conference
    • /
    • 2006.10a
    • /
    • pp.167-184
    • /
    • 2006
  • There is cattle shed and house structure of a country village in the vicinity of the construction site. that is why the environmental effect evaluation on blasting had been done in advance to prevent any harm to those from the work. As the result, it is impossible to apply to the blasting method, and the Super wedge method, a kind of a rock-splitting method which there is no secondary breaking by a breaker of the methods breaking &excavating rock according to the classification of the blasting method by the ministry of construction & transpotation, applied to decrease noise and vibration, and to the work classification, the extent of noise and vibration measured with the instrument only for noise(SC-310c) and with the instrument only for vibration(BLASTMATE) respectively. A drilling, splitting, collecting, loading works at the closest point(about 10m) is barely possible on the consideration of vibration to the result of measurement, but carefulness needs on moving of equipment. On the case of noise, even drilling, collecting, loading work except splitting at the comparatively close point(about 20m) is difficult. So, the method breaking &excavating rock according to the classification of the blasting method by the ministry of construction & transpotation has to apply in consideration of noise level in accordance with the work processing.

  • PDF

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE IMPLANT FRACTURES

  • Kim Yang-Soo;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.295-313
    • /
    • 2006
  • Statement of problem. Higher fracture rates were reported for Branemark implants placed in the maxilla and for 3.75 mm diameter implants installed in the posterior region. Purpose. The purpose of this study was to investigate the fracture of a fixture by finite element analysis and to compare different diameter of fixtures according to the level of alveolar bone resorption. Material and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for the 3i implant systems. Models were processed by the software programs HyperMesh and ANSA. Three-dimensional finite element models were developed for; (1) a regular titanium implant 3.75 mm in diameter and 13 mm in length (2) a regular titanium implant 4.0 mm in diameter and 13 mm in length (3) a wide titanium implant 5.0 mm in diameter and 13 mm in length each with a cementation type abutment and titanium alloy screw. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized as 650 N, and round and flat type prostheses were 12 mm in diameter, 9 mm in height were loaded to 600 N. Four loading offset points (0, 2, 4, and 6 mm from the center of the implants) were evaluated. To evaluate fixture fracture by alveolar bone resorption, we investigated the stress distribution of the fixtures according to different alveola. bone loss levels (0, 1.5, 3.5, and 5.0 mm of alveolar bone loss). Using these 12 models (four degrees of bone loss and three implant diameters), the effects of load-ing offset, the effect of alveolar bone resorption and the size of fixtures were evaluated. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView programs were used for post processing. Results. The results from our experiment are as follows: 1. Preload maintains implant-abutment joint stability within a limited offset point against occlusal force. 2. Von Mises stress of the implant, abutment screw, abutment, and bone was decreased with in-creasing of the implant diameter. 3. With severe advancing of alveolar bone resorption, fracture of the 3.75 and the 4.0 mm diameter implant was possible. 4. With increasing of bending stress by loading offset, fracture of the abutment screw was possible.

Experimental Study on Blast Resistance Improvement of RC Panels by FRP Retrofitting (철근콘크리트 패널의 FRP 보강에 의한 방폭 성능 향상에 관한 실험 연구)

  • Ha, Ju-Hyung;Yi, Na-Hyun;Kim, Sung-Bae;Choi, Jong-Kwon;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.93-102
    • /
    • 2010
  • Recently, FRP usage for strengthening RC structures in civil engineering has been increasing. Especially, the use of FRP to strengthen structures against blast loading is growing rapidly. To estimate FRP retrofitting effect under blast loading, blast tests with nine $1,000{\times}1,000{\times}150\;mm$ RC panel specimens, which were retrofitted with carbon fiber reinforced polymer (CFRP), Polyurea, CFRP with Poly-urea and basalt fiber reinforced polymer (BFRP) have been carried out. The applied blast load was generated by the detonation of 15.88 kg ANFO explosive charge at 1.5 m standoff distance. The data acquisitions not only included blast waves of incident pressure, reflected pressure, and impulse, but also included central deflection and strains at steel, concrete, and FRP surfaces. The failure mode of each specimen was observed and compared with a control specimen. From the test results, the blast resistance of each retrofit material was determined. The test results of each retrofit material will provide the basic information for preliminary selection of retrofit material to achieve the target retrofit performance and protection level.

A Study on pH Reduction of Recycled Aggregates Using Coffee Waste and Its Crushability (커피박을 이용한 순환골재의 pH 저감 및 파쇄성 연구)

  • Lee, Young-Jae;Lee, Dong-Yun;Chen, KeQiang;Kim, Moon-Gi;Park, Sung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.11
    • /
    • pp.21-29
    • /
    • 2016
  • In this study, recycled aggregates crushed from waste concrete were sorted into three groups, 10-13 mm, 13-20 mm, and 20-25 mm. They were treated in different ways and then their crushability was evaluated for each treatment. Coffee waste was used for reducing their pH level. The pH of recycled aggregate was almost 11, regardless of aggregate sizes. The pH of coffee waste was nearly 5 and 10, 30, or 50 g of coffee waste was mixed with 1000 ml of distilled water and recycled aggregates. The lowest pH was about 6.2 when 50 g of coffee waste was mixed. Aggregates were treated with microwave or soaked for 1 day in vinegar (pH = 2) for neutralization reaction. Microwave treated and neutralized aggregates showed 3.3% and 6.2% higher crushing values compared to non-treated one, respectively. Neutralized treatment was more effective for crushing. In crushing tests, a sample height of 120 mm was tried, which gave 6.3% higher crushing value. A four stepped loading with each 100 kN gave 7.1% higher crushing value, compared to standard 100 mm height and 400 kN continuous loading.