• Title/Summary/Keyword: loading height

Search Result 518, Processing Time 0.027 seconds

Application of ANFIS technique on performance of C and L shaped angle shear connectors

  • Sedghi, Yadollah;Zandi, Yousef;Shariati, Mahdi;Ahmadi, Ebrahim;Azar, Vahid Moghimi;Toghroli, Ali;Safa, Maryam;Mohamad, Edy Tonnizam;Khorami, Majid;Wakil, Karzan
    • Smart Structures and Systems
    • /
    • v.22 no.3
    • /
    • pp.335-340
    • /
    • 2018
  • The behavior of concrete slabs in composite beam with C and L shaped angle shear connectors has been studied in this paper. These two types of angle shear connectors' instalment have been commonly utilized. In this study, the finite element (FE) analysis and soft computing method have been used both to present the shear connectors' push out tests and providing data results used later in soft computing method. The current study has been performed to present the aforementioned shear connectors' behavior based on the variable factors aiming the study of diverse factors' effects on C and L shaped angle in shear connectors. ANFIS (Adaptive Neuro Fuzzy Inference System), has been manipulated in providing the effective parameters in shear strength forecasting by providing input-data comprising: height, length, thickness of shear connectors together with concrete strength and the respective slip of shear connectors. ANFIS has been also used to identify the predominant parameters influencing the shear strength forecast in C and L formed angle shear connectors.

Behavior of the Ground under a Building due to Adjacent Ground Excavation (근접굴착시 건물 하부 지반의 거동)

  • Lee, Jong-Min
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.4
    • /
    • pp.49-55
    • /
    • 2018
  • A pre-load of bracing was imposed to prevent the horizontal displacement on the strut of the braced wall adjacent to the building during the ground excavation. For this purpose, large scale model tests were conducted, without and with pre-load on braced wall. Adjacent building load was also imposed in different locations, that were 0 m, 1D, 2D on ground surface. In this study, model tests in 1:10 scale were performed in real construction sequences, and adjacent building was 12 m in width and the size of model test pit was 2 m in width, 6 m in height, and 4 m in length. As a result, it was found that the stability of the existing building adjacent to the braced wall within Rankine's active zone could be greatly enhanced when the horizontal displacement of the braced wall was reduced by applying a pre-load. which was larger than the designated axial force on the strut of the braced wall.

The Earth Pressure Distribution of Crib Wall (Crib Wall의 토압분포)

  • Oh, Sewook;Kwon, Youngcheul;Bae, Wooseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.5
    • /
    • pp.41-48
    • /
    • 2006
  • Crib wall is one of the segmental grid retaining walls using headers and stretchers to establish the framework of the wall. In this method, grids formed by the intersection of headers and stretchers are generally filled with the gravel to maintain the weight of the wall. Therefore, the construction can be carried out with higher speed and much economically when compared with the concrete retaining wall. Furthermore, it has high drain capacity, and environmentally friendly aspects also have been pointed out because the possibility of the planting at the front of the wall. However, in the crib wall method, the relative movement between the individual headers and stretchers was generally recognized, and stress redistribution in the gravel filling was also observed when subjected to the external loading and self-weight of filling. Therefore, it has been thought that the distribution of the earth pressure in the crib wall system differ from that of the concrete retaining wall. In this study, the surcharge tests using the scaled model crib wall was carried out to observe the distribution of the earth pressure in the segmental grid retaining wall. The earth pressure was measured in the six specified height of wall, and the distribution of the pressure was analyzed. Furthermore, the earth pressure by computation or by the test using the concrete retaining wall was also considered to make comparison.

  • PDF

Moment Control of Pier in Concrete Bridges Constructed by Free Cantilever Method (FCM 공법으로 시공되는 콘크리트 교량의 교각 모멘트 제어)

  • Yang, In-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.711-720
    • /
    • 2006
  • The structural behavior of concrete girder in bridges constructed by free cantilever method is time-dependent due to creep and shrinkage of concrete. The constraint effects of longitudinal movement of concrete girders can introduce unfavourable moment into piers. This study is aimed at proposing a method to reduce the moment of piers in bridge constructed by free cantilever method. The method are systematically composed of time-dependent structural analysis of bridges and loading of control force during construction of bridge. Numerical analyses are carried out depending on the parameters such as amount of control force and flexibility of pier. Time-dependent structural behavior shows that moment of pier increases according as pier height decreases. Also, moment of pier decreases when control method are applied. Numerical result of the study represents that time-dependent moment of piers can be controlled effectively by employing the proposed method.

Structural Behaviour of TEC-BEAM Connection with Steel Column Under Cyclic Loading (반복하중을 받는 TEC-BEAM 철골브라켓 접합부 거동평가)

  • Ju, Young Kyu;Kim, Ji Young;Kim, Myeong Han;Jung, Kwang Ryang;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.1
    • /
    • pp.51-58
    • /
    • 2002
  • To reduce the story height for high-rise buildings, the TEC Beam is developed as a new composite beam composed of structural tee, precast concrete, stirrup, and site-in-cast reinforced concrete slab. The preliminary test of the proposed system was performed for simple beams and it showed a good behavior. However, for the field application of the system, it is required to develope a steel moment resisting connection using steel brackets on which upper rebars of the TEC BEAM are anchored. In this paper, three types of the proposed system are experimentally investigated. The parameters of the test are as follows: (1) the spacing of transverse bars, (2) the ratio of width of rebar's layer to bracket length. Specimens were classified as semi-rigid full strength by the Eurocode 4. It could be concluded that the proposed moment resisting system shows a good structural behavior and may be applicable in the filed.

Performances of Ceramic-tube and Pall-ring Upflow Anaerobic Filters Treating a Dairy Waste (세라믹튜브 및 패킹형플라스틱 여재충전 상향류식 혐기성여상에 의한 유가공 폐수처리)

  • Hur, Joon-Moo;Chang, Duk;Pae, Hyung-Suk;Kim, Soo-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.1
    • /
    • pp.37-44
    • /
    • 2000
  • Laboratory experiments were conducted to investigate the performances of anaerobic filters packed with ceramic tube and pall-ring media treating a dairy waste. The media packing volume was 65% of effective volume of anaerobic filter. Organics removals of anaerobic filters were maintained above 80% even at an organics loading rate of $10kgCOD/m^3/d$, and this was comparable to aerobic treatment of organic wastes. Organics removals of the ceramic tube anaerobic filters were always lower than those of the pall-ring anaerobic filters due to intrinsic physical property of ceramic tube, especially lower void space which caused to clogging and entrapment of biogas, substrate transfer limitation, and irregular evolution of biogas leading to loss of solids and biomass. This was clearly observed in higher concentration of TSS in the effluent from the ceramic tube anaerobic filter despite of higher retention capacity of TSS compared with pall-ring media. Vertical distribution of organics and solids in the filters showed above 90% of organics and solids in influent were removed below 20% of reactor height, and 50% of remaining organics and solids were removed though media packing zone. Effluent quality from the anaerobic filter was heavily depended on media itself as well as suspended biomass formed below media. It is therefore concluded that the type of media played an important role in biomass accumulation arid gas-liquid-solid separation efficiency. Type of media did not affect the start-up behaviors of the anaerobic filter, and supernatant from anaerobic digested sludge showed a good performance as a seeding materials.

  • PDF

Comparison on Flexural Behaviors of Architectural Precast Prestressed Rectangular and Inverted-tee Concrete Beams (건축용 프리캐스트 프리스트레스트 역티형 보와 직사각형 보의 휨거동 비교)

  • 유승룡
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.6
    • /
    • pp.75-82
    • /
    • 2000
  • Flexural behaviors of two typical architectural precast beam sections ; inverted tee and rectangular - were compared and investigated. The heights of web in inverted tee beams are generally less than half of beam depth in building structures to accomodate the nib of double-tee where the total building height limited considerably. The inverted-tee beams are designed for parking live load - 500kgf/$\m^2$ and market - 1,200kgf/$\m^2$ according to the currently used typical shape in the domestic market building site in Korea. The bottom dimension and area of rectangular beams are same to those of inverted tee beams to compare the flexural behaviors of two beams. These two beams are also reinforced for similar strength. Four flexural tests are performed on two beams. Following results are obtained from the tests; 1) The rectangular beam is simpler in production, transportation, and election, and more economic than the inverted tee beam for these two beams with same dimension and similar strength. 1) The estimations of flexural strength of two beams by Strength Design Method and Strain Compatibility Method is fully complied with the result of tests. However, Strain Compatibility Method is slightly ore accurate than Strength Design Method. 2) Overall deflections of two type beam under the service loads are less than those of the allowable limit in ACI Code provision. 3) The rectangular beam is failed in large deflection (average 12.56mm large) than those of inverted tee beams. 4) The rectangular and inverted tee beams with 6m span develop initial flexural crackings under the 88% of full service loading even though they designed to satisfy the ACI tensile stress limit provisions.

Development of Cell Guide Quality Management System for Container Ships (컨테이너 선박의 셀 가이드 정도 관리 시스템 개발)

  • Park, Bong-Rae;Kim, Hyun-Cheol
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.158-165
    • /
    • 2018
  • Generally, container ships contain cargo holds with cell guides that serve to increase the container loading and unloading efficiency, minimize the space loss, and fix containers during the voyage. This paper describes a new quality management system for the cell guides of container ships (the so-called Trim Cell Guide system). The main functions of this system are the trimming of the point cloud obtained using a 3D scanner and an inspection simulation for cell guide quality. In other words, the raw point cloud of cell guides after construction is measured using a 3D scanner. Here, the raw point cloud contains a lot of noise and unnecessary information. Using the GUI interface supported by the system, the raw point cloud can be trimmed. The trimmed point cloud is used in a simulation for cell guide quality inspection. The RANSAC (Random Sample Consensus) algorithm is used for the transverse section representation of a cell guide at a certain height and applied for the calculation of the intervals between the cell guides and container. When the container hits the cell guides during the inspection simulation, the container is rotated horizontally and checked again for a possible collision. It focuses on a system that can be simulated with the same inspection process as in a shipyard. For a practicality review, we compared the precision data gained from an inspection simulation with the measured data. As a result, it was confirmed that these values were within approximately ${\pm}2mm$.

Characteristics of Pore Pressure and Volume Change During Undrained lending of Unsaturated Compacted Granite Soil (비배수전단시 불포화 다짐화강토의 간극압과 체적변형특성)

  • 김찬기;김태형;이종천
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.15-21
    • /
    • 2003
  • A series of triaxial compression tests were performed on samples of compacted granite soil in a modified triaxial cell that allowed separate control of pore air pressure ($U_a$) and pore water pressure ($U_w$) in order to examine the characteristics of pore pressure, volume change and stress-strain behavior during undrained loading conditions. Triaxial samples of unsaturated and saturated compacted granite soil, 50mm in diameter and 100mm in height, were prepared by compaction in a mould. These samples were tested at 3 different suction values (0.5, 1.0, 2.0 kgf/cm$^2$) for unsaturated compacted granite soil and at 3 different confining stresses (1.0, 2.0, 4.0 kgf/cm$^2$). Results showed that only effective cohesion increased with little variation of friction angle, according to matric suction.

Importance Factor Analysis on Mobility Facilities for the Transportation Disabled by Using Structural Equation Model (구조방정식(SEM)을 활용한 교통약자 이동편의시설의 중요도 분석)

  • Ahn, Woo-Young;Choi, Lee-Ra
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.939-945
    • /
    • 2014
  • In most of mobility enhancing plans for the transportation disabled, decisions for the investment priorities are firstly made by the facilities that have lower installation rate or lower satisfaction rate; the decisions are made without analyzing the importance factor (path loading factor) between the facility installation rate and the satisfaction rate together. In this study, a novel method of finding causality between the exogenous latent variables and the endogenous latent variables is provided by using the Structural Equation Model (SEM). The results show that the most influential facilities for the transportation disabled are bus stops, crosswalks and sidewalks in order. Also, a curb height around bus stops, a smoothness of sidewalks and installation of crosswalks traffic light are identified as an important facilities for the Transportation disabled.