• 제목/요약/키워드: loading condition

검색결과 1,882건 처리시간 0.032초

CCT시편의 형상과 하중조건이 J 적분에 미치는 영향 (The Effects of CCT Specimen Geometry and Loading Condition on the J-Integral)

  • 이억섭;김종호
    • 한국정밀공학회지
    • /
    • 제20권2호
    • /
    • pp.154-161
    • /
    • 2003
  • The effects of specimen geometry, and loading conditions on the J-integral fur CCT (center cracked tension) specimens are investigated by using FEM. It is found that the J-integral tends to decrease according to the parallel tensile loading to crack line. Furthermore, it is verified that the compressive parallel loading to crack line is likely to increase the J-integral. A stress ratio of length to width of the center CCT specimen is confirmed to affect the J-integral significantly.

현장정재하시험을 이용한 말뚝 거동특성 수치해석 예측기법의 신뢰성 검증 (Reliability Verification of Numerical Prediction Method on Pile Behaviour Characteristics using Field Static Loading Test)

  • 남호성;백승철
    • 한국지반환경공학회 논문집
    • /
    • 제18권9호
    • /
    • pp.11-18
    • /
    • 2017
  • 수치해석기법을 이용한 말뚝의 거동특성 예측방법은 정재하시험비가 고가이기 때문에 공사 전 말뚝의 거동을 예측할 수 있다는 장점으로 설계단계에서 널리 이용되고 있지만 그 신뢰성에 대한 연구는 부족한 실정이다. 본 연구에서는 실제 현장에서 말뚝의 거동과 수치해석으로 예측한 말뚝의 거동을 비교함으로써 수치해석 기법의 신뢰성을 검증하였다. 지반과 말뚝의 상호작용에 의한 말뚝의 거동을 정확하게 파악하기 위하여 정재하시험이 수행되는 지반에서 시추조사, 현장원위치시험 등을 통해 지반특성을 확인하였고, 실규모 정재하시험을 수행하여 말뚝의 거동특성을 분석하였다. 정재하시험이 수행된 방식과 동일하게 수치해석을 모사하여 재하시험과 동일한 하중단계에서 말뚝의 거동을 수치해석으로 모사하여 현장시험 결과와 비교함으로써 수치해석 기법의 신뢰성을 검증하였다.

하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소법적 응력분석 (Finite Element Stress Analysis of Implant Prosthesis according to Position and Direction of Load)

  • 배숙진;정재헌;정승미
    • 구강회복응용과학지
    • /
    • 제19권4호
    • /
    • pp.257-268
    • /
    • 2003
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis according to position and direction of load, under vertical and inclined loading using FEA analysis. The finite element model was designed according to standard fixture (4.1mm restorative component x 11.5mm length). The crown for mandibular first molar was made using UCLA abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric usp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment screw. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant in both vertical and oblique loading but stresses in the cancellous bone were low in both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. 4. The relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 5. The magnitude of the stress in the supporting bone, fixture and abutment screw was greater with the outward oblique loading than with the inward oblique loading and was the greatest under loading at the centric cusp in a $30^{\circ}$ outward oblique direction. Conclusively, this study provides evidence that bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. But it seems to be more important that how long is the distance from center of rotation of the implant itself to the resultant line of force from occlusal contact(leverage). The goal of improving implants should be to avoid bending of the implant.

An Experimental Study on Hydrodynamic Forces of Korea Autonomous Surface Ship in Various Loading Conditions

  • Nguyen, Thi Thanh Diep;Mai, Van Thuan;Lee, San;Yoon, Hyeon Kyu
    • 한국항해항만학회지
    • /
    • 제46권2호
    • /
    • pp.73-81
    • /
    • 2022
  • Currently, shipping by sea is becoming common because of the low price and the safety of goods. The ship is designed as a larger vessel to meet the need of this development. In the design stage, the investigation of hydrodynamic forces acting on the ship hull is very important in predicting the ship's maneuverability. Given that the ship docks at various ports for loading or discharging goods, the ship usually operates in various loading conditions, depending on the site condition and other various factors. Hence, it is necessary to investigate the effect of the loading condition on the hydrodynamic forces acting on the ship, to most accurately determine the maneuverability of the ship. In this study, an experiment of Korea Autonomous Surface Ship (KASS) was conducted at the towing tank of Changwon National University to measure the hydrodynamic forces acting on the KASS. The loading condition considered in this experiment is determined based on the draft, which was decreased by 5% for each loading condition. The smallest draft is 85% of the design draft. The static test as Oblique Towing Test (OTT), Circular Motion Test (CMT), Circular Motion Test with Drift (CMTD) is performed in the various loading conditions. First, the hydrodynamic forces in the Oblique Towing test (OTT) are compared with the result of other institutes. Second, the hydrodynamic forces in various drift angle, yaw rate and loading conditions are measured. Finally, the influence of the loading conditions on the hydrodynamic coefficient is discussed.

점증 재하를 고려한 선행재하 공법 적용 연약지반의 현장 계측을 통한 침하량 예측 방법의 개발 (Prediction Method of Settlement Based on Field Monitoring Data for Soft Ground Under Preloading Improvement with Ramp Loading)

  • 우상인;윤찬영;백승경;정충기
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.452-461
    • /
    • 2008
  • Previous settlement prediction method based on settlement monitoring such as hyperbolic, monden method were developed under instantaneous loading condition and have restriction to be applied to soft ground under ramp loading condition. In this study, settlement prediction method under ramp loading was developed. New settlement prediction method under ramp loading considers influence factors of consolidation settlement and increase accuracy of settlement prediction using field monitoring data after ramp loading. Large consolidation tests for ideally controlled one dimensional consolidation under ramp loading condition were performed and the settlement behavior was predicted based on the monitoring data. As a result, new prediction method is expected to have great applicability and practicability for the prediction of settlement behavior.

  • PDF

임플랜트-지대주의 내측연결 시스템에서 하중의 위치 및 경사에 따른 임플랜트 보철의 유한요소 응력분석 (Finite Element Stress Analysis of Implant Prosthesis of Internal Connection System According to Position and Direction of Load)

  • 장종석;정용태;정재헌
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.1-14
    • /
    • 2005
  • The purpose of this study was to assess the loading distributing characteristics of implant prosthesis of internal connection system(ITI system) according to position and direction of load, under vertical and inclined loading using finite element analysis (FEA). The finite element model of a synOcta implant and a solid abutment with $8^{\circ}$ internal conical joint used by the ITI implant was constructed. The gold crown for mandibular first molar was made on solid abutment. Each three-dimensional finite element model was created with the physical properties of the implant and surrounding bone. This study simulated loads of 200N at the central fossa in a vertical direction (loading condition A), 200N at the outside point of the central fossa with resin filling into screw hole in a vertical direction (loading condition B), 200N at the centric cusp in a $15^{\circ}$ inward oblique direction (loading condition C), 200N at the in a $30^{\circ}$ inward oblique direction (loading condition D) or 200N at the centric cusp in a $30^{\circ}$ outward oblique direction (loading condition E) individually. Von Mises stresses were recorded and compared in the supporting bone, fixture, and abutment. The following results have been made based on this study: 1. Stresses were concentrated mainly at the ridge crest around implant under both vertical and oblique loading but stresses in the cancellous bone were low under both vertical and oblique loading. 2. Bending moments resulting from non-axial loading of dental implants caused stress concentrations on cortical bone. The magnitude of the stress was greater with the oblique loading than with the vertical loading. 3. An offset of the vertical occlusal force in the buccolingual direction relative to the implant axis gave rise to increased bending of the implant. So, the relative positions of the resultant line of force from occlusal contact and the center of rotation seems to be more important. 4. In this internal conical joint, vertical and oblique loads were resisted mainly by the implant-abutment joint at the screw level and by the implant collar. Conclusively, It seems to be more important that how long the distance is from center of rotation of the implant itself to the resultant line of force from occlusal contact (leverage). In a morse taper implant, vertical and oblique loads are resisted mainly by the implant-abutment joint at the screw level and by the implant collar. This type of implant-abutment connection can also distribute forces deeper within the implant and shield the retention screw from excessive loading. Lateral forces are transmitted directly to the walls of the implant and the implant abutment mating bevels, providing greater resistance to interface opening.

Complete collapse test of reinforced concrete columns

  • Abdullah, Abdullah;Takiguchi, Katsuki
    • Structural Engineering and Mechanics
    • /
    • 제12권2호
    • /
    • pp.157-168
    • /
    • 2001
  • In this paper, experimental investigation into the behavior of reinforced concrete (RC) columns tested under large lateral displacement with four different types of loading arrangements is presented. Each loading arrangement has a different system for controlling the consistency of the loading condition. One of the loading arrangements used three units of link mechanism to control the parallelism of the top and bottom stub of column during testing, and the remaining employed eight hydraulic jacks for the same purpose. The loading systems condition used in this investigation were similar to the actual case in a moment-resisting frame where the tested column was displaced in a double curvature. Ten model column specimens, divided into four series were prepared. Two columns were tested monotonically until collapse, and unless failure took place at an earlier stage of loading, the remaining eight columns were tested under cyclic loading. Test results indicated that the proposed system to keep the top and bottom stubs parallel during testing performed well.

혼합모드 하중 하에서의 균열성장 중 피로파단면 마찰과 균열닫힘효과의 상호관계 (The Correlation between Fatigue Fracture Crack Surface Friction and Crack Closure Effect in Crack Growth under Mixed-mode loading)

  • 서기정;송삼홍;이정무
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.214-219
    • /
    • 2004
  • Crack tip behavior of single mode loading condition(mode I)depend on tensile loading component but one of mixed mode loading condition(mode I+II) have influenced on shear loading component like the practical structure. Because crack closure is caused by shear loading component under mixed-mode loading a research on the behavior in the stage of crack initiation and propagation require to be evaluate about crack closure effect by fatigue crack surface friction. For that reasion we examined the behavior at the crack tip by direct measuring method. Measured behavior at the crack tip was analyzed through vector crack tip displacement. As a result, crack propafation equation was corrected by considering with crack closure effect. In addition we compared fatigue fracture crack surface and crack closure level.

  • PDF

간헐적이고 불규칙적인 부하 조건에서 바이오필터의 Xylene 제거 성능 및 세균 활성 (Biofilter performance and bacterial activity under intermittent and fluctuant xylene loads)

  • 이은희;최선아;조경숙
    • 한국입자에어로졸학회지
    • /
    • 제7권1호
    • /
    • pp.9-19
    • /
    • 2011
  • The effects of different transient loading conditions on xylene removability and bacterial activity were evaluated in the polyurethane (PU) biofilter inoculated with Rhodococcus sp. EH831: BF1 (the control) was operated under continuous and constant loading ($200{\pm}50ppm$); BF2 under continuous and constant loading after a 2-week long-term shutdown; BF3 under discontinuous (8 h on/16 h off on weekdays and a 2 day-shutdown at weekends); and constant loading BF4 under discontinuous and high loading ($700{\pm}300ppm$); and BF5 under continuous and fluctuating loading (high loading for 8 h and low loading ($75{\pm}25ppm$) for 16 h on weekdays and low loading at weekends). Xylene removal efficiencies in the BF1, BF2, BF3, and BF5 were ranged 83-89%, indicating that 2-week long-term shutdown, intermittent or fluctuant loading condition did not significantly influence the biofilter performance. However, discontinuous and high load condition (BF4) caused to deteriorate xylene removability to 52%. Rhodococcus sp. EH831 could be maintained at $10^9{\sim}10^{10}CFU/g-dry$ PU under 5 kinds of loading conditions. The result of polymerase chain reaction-terminal-restriction fragment length polymorphism showed that there was no significant change in bacterial community structures by different loading conditions.

EFFECT OF STRENGTH MISMATCH AND DYNAMIC LOADING ON THE DUCTILE CRACK INITIATION FROM NOTCH ROOT

  • An, Gyn-Baek;Yoshida, Satoshi;Ohata, Mitsuru;Toyoda, Masao
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.145-150
    • /
    • 2002
  • It has been well known that ductile fracture of steels is accelerated by triaxial stresses. The characteristics of ductile crack initiation in steels are evaluated quantitatively using two-parameters criterion based on equivalent plastic strain and stress triaxiality. It has been demonstrated by authors using round-bar specimens with circumferential notch in single tension that the critical strain to initiate ductile crack from specimen center depends considerably on stress triaxiality, but surface cracking of notch root is in accordance with constant strain condition. In order to evaluate the stress/strain state in the specimens, especially under dynamic loading, a thermal, elastic-plastic, dynamic finite element (FE) analysis considering the temperature rise due to plastic deformation has been carried out. This study provides the fundamental clarification of the effect of strength mismatching, which can elevate plastic constraint due to heterogeneous plastic straining, loading mode and loading rate on critical condition to initiate ductile crack from notch root using equivalent plastic strain and stress triaxiality based on the two-parameter criterion obtained on homogeneous specimens under static tension. The critical condition to initiate ductile crack from notch root for strength mismatched bend specimens under both static and dynamic loading would be almost the same as that for homogeneous tensile specimens with circumferential sharp notch under static loading.

  • PDF