• 제목/요약/키워드: load-widening

검색결과 24건 처리시간 0.026초

노동과 건강 불평등, 그 근원은 어디인가? (What is the Origin of Inequalities in Work and Health?)

  • 손미아
    • Journal of Preventive Medicine and Public Health
    • /
    • 제38권3호
    • /
    • pp.241-251
    • /
    • 2005
  • There has been an enormous increasing trend of widening gap of social inequalities since economic crisis at the end of 1997 in Korea. Since then, Korean society has deteriorated in economic and social conditions; the unemployment rate, temporary or casual workers and absolute poverty have increased. This paper presents the origin of inequalities in work and health in Korea. The origin of inequalities in work begins with the relationship between the capitalist and labourers in the capitalist mode of production. The conception and execution are dissolved in the work process in the capitalist mode of production. Thus, captitalists become control over ther labour process from workers. An alienation of the work process from the workers. The distribution of work is the majour source if inequalities in many countries as well as Korea. This paper presents the increasing tendency of unhealthy states such as mortality, early death, morbidity, physical work load, workplace injury amongst the under-privileged: ordinary workers, unemployed people, casual workers and socially deprived people in Korea.

교량 확폭시 RC 상판 접합부의 휨 피로파괴거동에 관한 실험적 연구 (An Experimental Study on the Flexural Fatigue Fracture Behavior of RC Slab of Widened Bridge)

  • 박영훈;전준창;조병완;장동일
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 봄 학술발표회 논문집
    • /
    • pp.13-18
    • /
    • 1994
  • Most widened bridges have been constructed by the joining-construction method that makes new and existing bridge structurally single structure. However, joing-construction method has several problems in design and construction viewpoint. Therefore, this study is conducted in order to investigate structural behavior of widened RC slab and traffic-induced vibration of existing bridge during placing and curing of new concrete by the prototype flexural fatigue test. From the results of this study, it is shown that stress-concentration and slip occur between concrete and reinforcing rod at joint section but the reduction of load carrying capacity and of fatigue strength is negligible according to the traffic-induced vibration as well as the difference of construction method. A reasonable construction method for the bridge widening which takes into account the effects of the traffic-induced vibration and S-N curve for the widened bridge are also proposed.

  • PDF

새로운 고조파 저감형 고역율 단상정류 회로 (A New Harmonics Reducing Type High Factor Single-Phase Rectifier Circuit)

  • 김칠용;문상필;조만철;서기영;권순걸
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.468-472
    • /
    • 2007
  • For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. The absence of switching devices makes systems more tolerant to over-load, and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method, It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced. The result are confirmed by the theoretical and expermental implementations

  • PDF

입력전류의 정현화에 의한 단상PFC정류회로의 토폴로지 (Topology of Single-Phase PFC Rectifier Circuit with Sinusoidal of Input Current)

  • 이상현;김영문;권순걸;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.290-293
    • /
    • 2002
  • For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. However, most of these employ switching devices, such as FETs and the like. The absence of switching devices makes systems more tolerant to over-load, and brings low radio noise benefits. We propose a power factor connection scheme using a LC resonant in commercial frequency without switching devices. In this method, It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced. The result are confirmed by the theoretical and experimental implementations.

  • PDF

PSC 박스거더 교량부재의 횡방향 프리스트레싱에 따른 구조거동 실험연구 (An Experimental Study on Structural Behavior of Concrete Box Girder Member with Transverse Prestressing)

  • 오병환;최영철;최정선;이성철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.77-80
    • /
    • 2004
  • In bridge deck systems, deflections and cracking can be controlled by longitudinal and transverse prestressing, There are some benefits, longitudinal cracking control, the thickness reduction of deck slab, the widening of deck width and the reduction of the cross section area, in transversely post-tensioned concrete box girder bridges. However, it has been not sufficient to study the structural behaviors of transversely post-tensioned concrete box girder. Therefore, It is needed to predict the structural behaviors by prestressing and static loading. In this study, the analytical and experimental load tests are carried out to study the effect of transverse prestressing on concrete box girder. For these objectives, four test specimens are fabricated with various tendon spacing and steel ratio of top slab. The analytical and experimental studies are performed to estimate effects of the prestressing and failure tests.

  • PDF

LC공진에 의한 단상 PFC정류회로의 연구 (A Study of Single-Phase PFC Rectifier Circuit by LC Resonance)

  • 이상현;박진민;김영문;권순걸;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1235-1237
    • /
    • 2003
  • For small capacity rectifier circuits as these for consumer electronics and appli capacitor input type rectifier circuits are gen used. Consequently. various harmonics gen within the power system become a serious pro Various studies of this effect have been pres previously. However. most of these employ swit devices, such as FETs and the like. The absen switching devices makes systems more toleran over -load, and brings low radio noise benefits propose a power factor correction scheme using resonant in commercial frequency without swit devices. In this method. It makes a sinusoidal by widening conduction period using the cu resonance in commercial frequency. Hence, harmonic characteristics can be significantly imp where the lower order harmonics. such as the and seventh orders are much reduced. The resu confirmed by the theoretical and experm implementations.

  • PDF

입력전류 파형 개선형 단상 정류기의 토폴로지 (Topology of input current waveform improvement type single-phase rectifier)

  • 이상현;박진민;문상필;서기영
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.403-406
    • /
    • 2003
  • For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. However, most of these employ switching devices, such as FET and the like. The absence of switching devices mattes systems more tolerant to over-load and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced The result are confirmed by the theoretical and experimental implementations.

  • PDF

Integration of in-situ load experiments and numerical modeling in a long-term bridge monitoring system on a newly-constructed widened section of freeway in Taiwan

  • Chiu, Yi-Tsung;Lin, Tzu-Kang;Hung, Hsiao-Hui;Sung, Yu-Chi;Chang, Kuo-Chun
    • Smart Structures and Systems
    • /
    • 제13권6호
    • /
    • pp.1015-1039
    • /
    • 2014
  • The widening project on Freeway No.1 in Taiwan has a total length of roughly 14 kilometers, and includes three special bridges, namely a 216 m long-span bridge crossing the original freeway, an F-bent double decked bridge in a co-constructed section, and a steel and prestressed concrete composite bridge. This study employed in-situ monitoring in conjunction with numerical modeling to establish a real-time monitoring system for the three bridges. In order to determine the initial static and dynamic behavior of the real bridges, forced vibration experiments, in-situ static load experiments, and dynamic load experiments were first carried out on the newly-constructed bridges before they went into use. Structural models of the bridges were then established using the finite element method, and in-situ vehicle load weight, arrangement, and speed were taken into consideration when performing comparisons employing data obtained from experimental measurements. The results showed consistency between the analytical simulations and experimental data. After determining a bridge's initial state, the proposed in-situ monitoring system, which is employed in conjunction with the established finite element model, can be utilized to assess the safety of a bridge's members, providing useful reference information to bridge management agencies.

상용주파주의 LC공진을 이용한 단상고역률정류회로 (A single-phase high-power-factor rectifier using LC resonance in commercial frequenc)

  • 김주용;이상현;김영문;이현우;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.204-206
    • /
    • 2002
  • For small capacity rectifier circuits such as these for consumer electronics and appliances. capacitor input type rectifier circuits are generally used Consequently. various harmonics generated within the power system become a serious Problem. Various studies of this effect have been presented previously. However. most of these employ switching devices, such as FETs and the like. The absence of switching devices makes systems more tolerant to over -load, and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method. It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency. Hence, the harmonic characteristics can be significantly improved. where the lower order harmonics. such as the fifth and seventh orders are much reduced. The result are confirmed by the theoretical and expermental implementations.

  • PDF

교통관련 포장지역 비점오염원에서의 오염물질 유출원단위 산정 (Determination of Pollutant Unit Loads from Various Transportation Landuses)

  • 이소영;이은주;;김이형
    • 한국물환경학회지
    • /
    • 제24권5호
    • /
    • pp.543-549
    • /
    • 2008
  • Human activities and land-use practices are intensely widening the urban areas. High impervious surface areas cover much of urban landscapes and are the primary pollutant sources which can lead to water quality and habitat degradation in its watershed. As the urban areas expand, transportation land-use such as parking lots, roads, service areas, toll-gates in highways and bridges also increase. These land-uses are significant in urban pollution due to high imperviousness rate and vehicular activities. To regulate the environmental impacts and to improve the water quality of rivers and lakes, the Ministry of Environment (MOE) in Korea developed the Total Pollution Load Management System (TPLMS) program. The main objective is to lead the watershed for a low impact development. On a local scale, some urban land surfaces can be emitting more pollution than others. Consequently, in urban areas, the unit loads are commonly employed to estimate total pollutant loadings emitted from various land-uses including residential, commercial, industrial, transportation, open lands such as parks and golf courses, and other developed land like parking areas as a result of development. In this research, unit pollutant loads derived specifically from transportation land-uses (i.e. branched out from urban areas) will be provided. Monitoring was conducted over 56 storm events at nine monitoring locations during three years. Results for the unit pollutant loads of transportation land-use are determined to be $399.5kg/km^2-day$ for TSS, $12.3kg/km^2-day$ for TN and $2.46kg/km^2-day$ for TP. The values are higher than those of urban areas in Korean MOE and US highways. These results can be used by MOE to separate the pollutant unit load of transportation landuses from urban areas.