• Title/Summary/Keyword: load estimation

Search Result 1,698, Processing Time 0.035 seconds

Seismic Design of Columns in Inverted V-braced Steel Frames Considering Brace Buckling (가새좌굴을 고려한 역 V형 가새골조의 기둥부재 내진설계법)

  • Cho, Chun-Hee;Kim, Jung-Jae;Lee, Cheol-Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.22 no.1
    • /
    • pp.1-12
    • /
    • 2010
  • According to the capacity design concept which forms the basis of the current steel seismic codes, the braces in concentrically braced frames (CBFs) should dissipate seismic energy through cyclic tension yielding and cyclic compression buckling while the beams and the columns should remain elastic. Brace buckling in inverted V-braced frames induces unbalanced vertical forces which, in turn, impose the additional beam moments and column axial forces. However, due to difficulty in predicting the location of buckling stories, the most conservative approach implied in the design code is to estimate the column axial forces by adding all the unbalanced vertical forces in the upper stories. One alternative approach, less conservative and recommended by the current code, is to estimate the column axial forces based on the amplified seismic load expected at the mechanism-level response. Both are either too conservative or lacking technical foundation. In this paper, three combination rules for a rational estimation of the column axial forces were proposed. The idea central to the three methods is to detect the stories of high buckling potential based on pushover analysis and dynamic behavior. The unbalanced vertical forces in the stories detected as high buckling potential are summed in a linear manner while those in other stories are combined by following the SRSS(square root of sum of squares) rule. The accuracy and design advantage of the three methods were validated by comparing extensive inelastic dynamic analysis results. The mode-shape based method(MSBM), which is both simple and accurate, is recommended as the method of choice for practicing engineers among the three.

Development of Robotic Inspection System over Bridge Superstructure (교량 상판 하부 안전점검 로봇개발)

  • Nam Soon-Sung;Jang Jung-Whan;Yang Kyung-Taek
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.180-185
    • /
    • 2003
  • The increase of traffic over a bridge has been emerged as one of the most severe problems in view of bridge maintenance, since the load effect caused by the vehicle passage over the bridge has brought out a long-term damage to bridge structure, and it is nearly impossible to maintain operational serviceability of bridge to user's satisfactory level without any concern on bridge maintenance at the phase of completion. Moreover, bridge maintenance operation should be performed by regular inspection over the bridge to prevent structural malfunction or unexpected accidents front breaking out by monitoring on cracks or deformations during service. Therefore, technical breakthrough related to this uninterested field of bridge maintenance leading the public to the turning point of recognition is desperately needed. This study has the aim of development on automated inspection system to lower surface of bridge superstructures to replace the conventional system of bridge inspection with the naked eye, where the monitoring staff is directly on board to refractive or other type of maintenance .vehicles, with which it is expected that we can solve the problems essentially where the results of inspection are varied to change with subjective manlier from monitoring staff, increase stabilities in safety during the inspection, and make contribution to construct data base by providing objective and quantitative data and materials through image processing method over data captured by cameras. By this system it is also expected that objective estimation over the right time of maintenance and reinforcement work will lead enormous decrease in maintenance cost.

  • PDF

Spatial Characteristics of Pollutant Concentrations in the Streams of Shihwa Lake (시화호 유입하천의 수질오염물질 농도에 관한 연구)

  • Jang, Jeong-Ik;Han, Ihn-Sup;Kim, Kyung-Tae;Ra, Kong-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.289-299
    • /
    • 2011
  • We studied the characteristics of pollutant concentrations in 9 streams that flow into Shihwa Lake in order to provide the scientific data for effective implementation of total pollution loads management system (TPLMS) of the Lake. Suspended solid (SS), chemical oxygen demand (COD), dissolved nutrients ($NO_2$, $NO_3$, $NH_4$, $PO_4$ and $SiO_2$), total phosphorus (TP) and total nitrogen (TN) in stream water from industrial complexes, urban and agricultural regions were determined. Pollutant concentrations in December were higher than that in other sampling periods. COD concentration from industrial complex region with average of 12.6 mg/L was 2 times higher those from urban region (6.6 mg/L) and agricultural region (5.9 mg/L). TP concentration from industrial region also showed higher concentration than other regions. TN concentration in stream water was 5.89 mg/L for industrial region, 3.02 mg/L for urban region and 5.27 mg/L for agricultural region, respectively, suggesting inflow of TN due to fertilizer usage in agricultural field. Relative percentage of nitrogen compounds in TN follows the sequence: $NH_4$ (35.1%) > $NO_2$ (20.0%) > DON (22.8%) > PON (8.9%) > $NO_2$ (3.2%). Concentrations of dissolved nutrients, TP and TN in stream water were 3.2~37.2 times higher than that in Shihwa Lake seawater, therefore large amount of pollutants may be directly entered into Shihwa Lake without any treatment. For Gunja stream of industrial region, pollutants at midstream showed relatively higher concentration compared to upstream and downstream. It is necessary to manage the illegal discharging of sewage and waste water. Our results provide valuable informations on the estimation and reduction of total pollutant loads in the process of establishing adequately strategic and implemental plan of Shihwa Lake TPLMS.

Soil Loss and Pollutant Load Estimation in Sacheon River Watershed using a Geographic Information System (GIS를 이용한 동해안 하천유역의 토양유실량과 오염부하량 평가 -사천천을 중심으로-)

  • Cho, Jae-Heon;Yeon, Je-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1331-1343
    • /
    • 2000
  • Through the integration of USLE and GIS, the methodology to estimate the soil loss was developed, and applicated to the Sacheon river in Gangrung. Using GIS, spatial analysis such as watershed boundary determination, flow routing. slope steepness calculation was done. Spatial information from the GIS application was given for each grid. With soil and land use map, information about soil classification and land use was given for each grid too. Based upon these data, thematic maps about the factors of USLE were made. We estimated the soil loss by overlaying the thematic maps. In this manner, we can assess the degree of soil loss for each grid using GIS. Annual average soil loss of Sacheon river watershed is 1.36 ton/ha/yr. Soil loss in forest, dry field, and paddy field is 0.15 ton/ha/yr, 27.04 ton/ha/yr, 0.78 ton/ha/yr respectively. The area of dry field, which is 4% of total area, is $2.4km^2$. But total soil loss of dry field is 6561 ton/yr, and it occupies 84.9 % of total soil loss eroded in Sacheon river watershed. Comparing with the 11.2 ton/ha/yr of an average soil loss tolerance for cropland, provision for the soil loss in dry field is necessary. Run-off and water quality of Sacheon river were measured two times in flood season: from July 24, 1998 to July 28 and from September 29 to October 1. As the run-off of the river increased, SS, TN, TP concentrations and pollutant loadings increased. SS, TN, TP loads of Sacheon river discharged during the 2 heavy rains were 21%, 39%, and 19% of the total pollutant loadings generated in the Sacheon river watershed for one year. We can see that much pollutants are discharged in short period of flood season.

  • PDF

Environmental Impact Assessment by Marine Cage Fish Farms: II. Estimation of Hydrogen Sulfide Oxidation Rate at $O_2$-H$_2$S Interface and Sulfate Reduction Rate in Anoxic Sediment Layer (해상 어류가두리양식장의 환경영향 평가: II. 가두리 양식장 퇴적물의 산소-황화수소 경계면에서 황화수소의 산화율 및 무산소 퇴적층에서 황산염 환원율 추정)

  • Lee, Jae-Seong;Kim, Kee-Hyun;Yu, Jun;Lee, Pil-Yong;Jung, Rae-Hong;Lee, Wong-Chan;Han, Jung-Jee;Lee, Yong-Hwa
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.9 no.2
    • /
    • pp.64-72
    • /
    • 2004
  • We measured the vertical profiles of $O_2$, H$_2$S, and pH in sediment pore water beneath marine cage fish farms using a microsensor with a 25 ${\mu}{\textrm}{m}$ sensor tip size. The sediments are characterized by high organic material load. The oxygen consumption, hydrogen sulfide oxidation, and sulfate reduction rates in the microzonations (derived from the vertical distribution of chemical species concentration) were estimated by adapting a simple one-dimensional diffusion-reaction model. The oxygen penetration depth was 0.75 mm. The oxic microzonations were divided into upper and lower layers. Due to hydrogen sulfide oxidation within the oxic zone, the oxygen consumption rate was higher in the lower layer. The total oxygen consumption rate integrated with reaction zone depth was estimated to be 0.092 $\mu$mol $O_2$cm$^{-2}$ hr$^{-1}$ . The total hydrogen sulfide oxidation rate occurring within 0.7 mm thickness was estimated to be 0.030 $\mu$mo1 H$_2$S cm$^{-2}$ hr$^{-1}$ , and its turnover time in the oxic sediment layer was estimated to be about 2 minutes. This suggests that hydrogen sulfide was oxidized by both chemical and microbial processes in this zone. The molar consumption ratio, calculated to be 0.84, indicates that either other electron accepters exit on hydrogen sulfide oxidation, or elemental sulfur precipitation occurs near the $O_2$- H$_2$S interface. Total sulfate reduction flux was estimated to be 0.029 $\mu$mol cm$^{-2}$ hr$^{-1}$ , which accounted for more than 60% of total $O_2$ consumption flux. This result implied that the degradation of organic matter in the anoxic layer was larger than in the oxic layer.

Serum Beta-2 Microglobulin: a Possible Marker for Disease Progression in Egyptian Patients with Chronic HCV Related Liver Diseases

  • Ouda, SM;Khairy, AM;Sorour, Ashraf E;Mikhail, Mikhail Nasr
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7825-7829
    • /
    • 2015
  • Background: Egypt has the highest prevalence of HCV infection in the world (~14.7%). Around 10-15% of HCV-infected persons will advance to cirrhosis within the first 20 years. The incidence of HCC is expected to grow in the next two decades, largely due to HCV related cirrhosis, and detection of HCC at an early stage is critical for a favorable clinical outcome. No simple reliable non-invasive marker has been available till now. B2M, a non-glycosylated polypeptide composed of 99 amino acids, is one of the components of HLA class I molecules on the surfaces of all nucleated cells. It has been reported that the level of serum B2M is elevated in patients with chronic hepatitis C and HCV-related HCC when compared to HCV-negative patients or healthy donors. Determining the clinical utility of serum B2M as a marker for disease progression in Egyptian patients with HCV related chronic hepatitis, cirrhosis and hepatocellular carcinoma was the aim of the present study. Materials and Methods: In this analytical cross sectional study 92 participants were included in 4 equal groups: Group (1) non cirrhotic chronic HCV; Group (2) HCV related liver cirrhosis; Group (3) HCC on top of HCV,; and Group (4) healthy controls. History taking, clinical examination, routine labs and abdominal ultrasound were conducted for all patients, PCR and Metavir scores for group (1) patients, and triphasic CT abdomen and AFP for Group (3) patients. B2M levels were measured in serum with a fully-automated IMX system. Results: The mean serum B2M level of Group (1) was $4.25{\pm}1.48{\mu}g/ml$., Group (2) was $7.48{\pm}3.04$, Group (3) was $6.62{\pm}2.49$ and Group (4) was $1.62{\pm}0.63$. Serum B2M levels were significantly higher in diseased than control group (p<0.01) being significantly higher in cirrhosis ($7.48{\pm}3.04$) and HCC groups ($6.62{\pm}2.49$) than the HCV group ($4.25{\pm}1.48$) (p<0.01). There was a significant correlation between B2M Level and ALK, total and direct bilirubin and INR (p<0.05), and a significant inverse correlation between B2M level and albumin, total proteins, HB andWBCS values (p<0.05). There was no significant correlation between B2M level and viral load or Metavir score, largest tumour size or AFP (p>0.05). The best B2M cut-off for HCV diagnosis was 2.6 with a sensitivity of 100%, a specificity of 92%, a positive predictive value (PPV) of 97% and a negative predictive value (NPV) of 100%. The best B2M cut-off for HCC diagnosis was 4.55 which yielded sensitivity, specificity, positive predictive value, negative predictive values of 74%, 62%, 39.5, 87.8% respectively (p-value <0.01) while best cut-off for cirrhosis was 4.9, with sensitivity 74 % and specificity 74%.The sensitivity for HCC diagnosis increased upon B2M and AFP combined estimation to 91%, specificity to 79%, NPV to 95% and accuracy to 83%. Conclusions: Serum B2M level is elevated in HCV related chronic liver diseases and may be used as a marker for HCV disease progression towards cirrhosis and carcinoma.

Studies on Ancylostomiasis I. An Experimental Study on Hookworm Infection and Anemia (구충증(鉤蟲症)에 관(關)한 연구(硏究) 제1편(第1篇) 구충(鉤蟲)의 감염(感染) 및 구충성빈혈(鉤蟲性貧血)에 관(關)한 고찰(考奈))

  • Lee, Mun-Ho;Kim, Dong-Jip;Lee, Jang-Kyu;Seo, Byong-Sul;Lee, Soon-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.1 no.1
    • /
    • pp.55-66
    • /
    • 1967
  • In view of its prevalence in the Far East area, a more detailed knowledge on the hookworm infection is one of the very important medical problems. The present study was aimed to; determine the infectivity of the artificially hatched ancylostoma duodenale larvae in man after its oral administration, evaluate the clinical symptomatology of such infection, determine the date of first appearance of the ova in the stool, calculate the blood loss per worm per day, assess the relation-ships between the ova count, infectivity(worm load), blood loss and severity of anemia. An erythrokinetic study was also done to analyse the characteristics of hookworm anemia by means of $^{59}Fe\;and\;^{51}Cr$. Materials and Methods Ten healthy male volunteers(doctors, medical students and laboratory technicians) with the ages ranging from 21 to 40 years were selected as the experimental materials. They had no history of hookworm infection for preceding several years, and care was taken not to be exposed to reinfection. A baseline study including a through physical examinations and laboratory investigations such as complete blood counts, stool examination and estimation of the serum iron levels was done, and a vermifuge, bephenium hydroxynaphoate, was given 10 days prior to the main experiment. The ancylostoma duodenale filariform larvae were obtained in the following manner; The pure ancylostoma duodenale ova were obtained from the hookworm anemia patients and a modified filter paper method was adopted to harvest larger number of infective larvae, which were washed several times with saline. The actively moving mature larvae were put into the gelatine capsules, 150 in each, and were given to the volunteers in the fasting state with 300ml. of water. The volunteers were previously treated with intramuscular injection of 15mg. of chlorpromazine in order to prevent the eventual nausea and vomiting after the larvae intake. The clinical symptoms and signs mainly of the respiratory and gastrointestinal tracts, appearance of the ova and occult blood in the stool etc. were checked every day for the first 20 days and then twice weekly until the end of the experiment, which usually lasted for about 3 months. Roentgenological survey of the lungs was also done. The hematological changes such as the red blood cell, white blood cell and eosinophil cell counts, hemoglobin content and serum iron levels were studied. The appearance of the ova in the stool was examined by the formalin ether method and the ova were counted in triplicate on two successive days using the Stoll's dilution method. The ferrokinetic data were calculated by the modified Huff's method and the apparent half survival time of the red blood cells by the modified Gray's method. The isotopes were simultaneously tagged and injected intravenously, and then the stool and blood samples were collected as was described by Roche et al., namely, three separate 4-day stool samples with the blood sample drawing before each 4-day stool collection. The radio-activities of the stools ashfied and the blood were separately measured by the pulse-height analyser. The daily blood loss was calculated with the following formula; daily blood loss in $ml.=\frac{cpm/g\;stool{\times}weight\;in\;g\;of\;4-day\;stool}{cpm/ml\;blood{\times}4}$ The average of these three 4-day periods was given as the daily blood loss in each patient. The blood loss per day per worm was calculated by simply dividing the daily blood loss by the number of the hookworm recovered after the vermifuge given twice a week at the termination of the experiment. The iron loss in mg. through the gastrointestinal tract was estimated with the daily iron loss in $mg=\frac{g\;Hgb/100ml{\times}ml\;daily\;blood\;loss{\times}3.40}{100}$ 3.40=mg of iron per g Hgb following formula; Results 1. The respiratory symptoms such as cough and sputum were noted in almost all cases within a week after the infection, which lasted about 2 weeks. The roentgenological findings of the chest were essentially normal. A moderate degree of febril reaction appeared within 2 weeks with a duration of 3 or 4 days. 2. The gastrointestinal symptoms such as nausea, epigastric fullness, abdominal pain and loose bowel appeared in all cases immediately after the larvae intake. 3. The reduction of the red blood cell count was not remarkable, however, the hemoglobin content and especially the serum iron level showed the steady decreases until the end of the experiment. 4. The white blood cells and eosinophil cells, on the contrary, showed increases in parallel and reached peaks in 20 to 30 days after the infection. A small secondary rise was noted in 2 months. 5. The ova first appeared in the stool in 40. 1 days after the infection, ranging from 29 to 51 days, during which the occult blood reaction of the stool became also positive in almost cases. 6. The number of ova recovered per day was 164, 320 on the average, ranging from 89,500 to 253,800. The number of the worm evacuated by vermifuge was in rough correlation with the number of ova recovered. 7. The infectivity of ancylostoma duodenale was 14% on the average, ranging from 7.3 to 20.0%, which is relatively lower than those reported by other workers. 8. The mean fecal blood loss was 5.78ml. per day, with a range of from 2.6 to 11.7ml., and the mean blood loss per worm per day was 0.30ml., with a range of from 0.13 to 0.73ml., which is in rough coincidence with those reported by other authors. There appeared to exist, however, no correlation between the blood loss and the number of ova recovered. 9. The mean fecal iron loss was 2.02mg. per day, with a range of from 1.20 to 3.89mg., which is less than those appeared in the literature. 10. The mean plasma iron disappearance rate was 0.80hr., with a range of from 0.62 to 0.95hr., namely, a slight accerelation. 11. The hookworm anemia appeared to be iron deficiency in origin caused by continuous intestinal blood loss.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF