• 제목/요약/키워드: load coefficient

검색결과 1,577건 처리시간 0.037초

Friction Characteristics of Aluminized Polyester Fabric under Dry - and Water- Lubricated Conditions

  • Byun, JaeYoung;Okechukwu, Nicholas Nnaemeka;Lee, Eunsuk;Park, JinGyu;Choi, WonSik
    • Tribology and Lubricants
    • /
    • 제35권6호
    • /
    • pp.396-402
    • /
    • 2019
  • Materials made from plastics are increasingly utilized in constructing greenhouses and setting up shield structures. Polyester fabrics have a wide range of use in horticulture and other fields of agriculture. They are utilized as a greenhouse cover and also help in combating intense climate variation in the field. Over time, these fabrics may experience friction against other surfaces. Owing to this, the surface framework of the material degenerates. This study examines the frictional characteristics of aluminized polyester fabric in both dry- and water-lubricated environments under changing applied loads and sliding speeds. Friction experiments are performed at room temperature by employing a pin on a disk. The experiments reveal that the friction coefficient decreases with increase in applied load in both dry sliding and water-lubricated environment. However, the friction coefficient decreases more under the water-lubricated setting than in the dry state. At the maximum applied load, the highest friction coefficient is discovered in the dry state with a range of 0.282 to 0.237, whereas a friction coefficient of 0.229 to 0.189 is observed in the water-lubricated state. Additionally, it is observed that the friction coefficient increases with an increase in sliding speed under both experimental environments. The examination of specimen surfaces reveals that the abrasion is minor in the water-lubricated setting compared with that in the dry state.

Estimation on clamping load of high strength bolts considering various environment conditions

  • Nah, Hwan-Seon;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제24권4호
    • /
    • pp.399-408
    • /
    • 2017
  • Of high strength bolts, the torque shear type bolt is known to be clamped normally when pin-tails are broken. Sometimes the clamping loads on slip critical connections considerably fluctuate from the required tension due to variation of torque coefficient. This is why the viscosity of lubricant affects the torque coefficient by temperature. In this study, the clamping tests of high strength bolts were performed independently at laboratory conditions and at outdoor environment. The temperatures of outdoor environment candidates were ranged from $-11^{\circ}C$ to $34^{\circ}C$ for six years. The temperature at laboratory condition was composed from $-10^{\circ}C$ to $50^{\circ}C$ at each $10^{\circ}C$ interval. At outdoor environment conditions, the clamping load of high strength bolt was varied from 159 to 210 kN and the torque value was varied from 405 to 556 Nm. The torque coefficients at outdoor environment were calculated from 0.126 to 0.158 when tensions were measured from 179 to 192 kN by using tension meter. The torque coefficients at outdoor environment conditions were analyzed as the range from 0.118 to 0.152. From these tests, the diverse equations of torque coefficient, tension dependent to temperature can be acquired by statistic regressive analysis. The variable of torque coefficient at laboratory conditions is 0.13% per each $1^{\circ}C$ when it reaches 2.73% per each $1^{\circ}C$ at outdoor environment conditions. When the results at laboratory conditions and at outdoor environment were combined to get the revised equations, the change in torque coefficient was modified as 0.2% per each $1^{\circ}C$ and the increment of tension was adjusted as 1.89 % per each $1^{\circ}C$.

PCB Handler의 과도응답해석 및 충격계수 산출 연구 (A Study on the Transient Response and Impact Coefficient Calculation of PCB Handler)

  • 이병화;권순기;고만수
    • 디지털융복합연구
    • /
    • 제15권7호
    • /
    • pp.223-229
    • /
    • 2017
  • 유럽, 미국을 비롯한 일본 등 선진 업계에서는 오랜 기간의 시험을 거쳐 충격계수의 시험결과를 보유하고 있으며, 장비를 설계할 때 이를 적용하여 구조물의 안정성을 확보하고 있다. 그러나 국내 산업체의 실정으로는 실제 구조물이 받는 여러 가지 동적인 외력에 의한 영향을 시험을 통해 충격계수를 확보하기에는 많은 비용과 시간이 소요되기 때문에 선진업체에서 제공하는 충격계수를 활용하여 장비를 설계하고 있다. 본 논문에서는 유한요소해석 프로그램인 NX/NASTRAN을 이용하여 반도체 검사 장비인 PCB Handler의 정하중해석과 충격하중에 대한 과도응답 해석을 진행하고, 변위 결과를 비교하는 방법으로 충격계수를 산출하였다. 충격계수 산출 방법은 일본 구조 구격에서 사용하고 있는 방법을 적용하였으며, PCB Handler가 검사를 위해 급출발 또는 급정지 시 충격계수는 1.27로 산출되었다. 해석으로 얻어낸 충격계수는 향후 장비의 구조개선과 기존장비를 기반으로 제품 개발 시 사용할 수 있어 업계에 도움이 될 것으로 판단된다.

교량 구조의 하중분배 효과에 관한 연구 (A Study on Load distribution Effect for Bridge Structures)

  • 정철헌;오병환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.234-239
    • /
    • 1992
  • Design live load and girder distribution factors play an important role in the current design procedures. The fraction of vehicle load effect transferred to a single member may be selected in accordance with current KBDC. However, the specified values, both design load and distribution factors involve considerable inaccuracies, These inaccuracies relate to the uncertainties of the structural analysis, especially any bias and scatter which drives from the use of simplified load distribution factors. In this study , based on several field measurement and finite element analysis, live load distribution effects of current KBDC are evaluated. The final values of the bias and coefficient of variation of "g"according to bridge type are determined. The bridge types are reinforced concrete slab, prestressed concrete girder and steel l-beam.el l-beam.

  • PDF

슬러지 순화조건과 접촉부하가 혐기상태에서 인과 유기물의 거동에 미치는 영향 (The Rffect of Sludge Acclimation Conditions and Contact Load on Phosphorus and Organic Substrates Behanio Under Anaerobic Conditions)

  • 박동근
    • 한국환경과학회지
    • /
    • 제3권4호
    • /
    • pp.427-437
    • /
    • 1994
  • Batch experiments were performed to evaluate the effect of sludge acclimation and contact load on the behavior of phosphorus and organic substrates under anaerobic conditions. Four different sludges were acclimated in the sequencing batch reactors operated by intermittent aeration. All the experiments performed in a bench scale have shown the following results: 1. The unreleaseable phosphorus contents for four different sludges are the range of 16 mg P/g SS to 24 mg P/g SS, depending on the sludge acclimation conditions. 2. All the specific substrate uptake rates(SSUR) are expressed in the first order equation for releaseable phosphorus contents. The reaction rate coefficient k, has the values of 4.0, 8.9, and 13.8 mg COD/mg P/hr, depending on the contact load and slut식e species. 3. As reaction proceeds, the ratios of $\delta$P to -$\delta$COD at high contact load are almost constant in the range of 0.10 to 0.14, but at low contact load, they increase from 0.08 to 0.27.

  • PDF

스마트 스킨 구조물의 좌굴 특성 연구 (Characteristics of smart skin under buckling load)

  • 전지훈;유치상;황운봉;박현철;박위상
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.790-793
    • /
    • 2001
  • The characteristics of smart skin for wireless LAN system under compression load are investigated. The smart skin structure is composed of 3 layers of face material and 2 layers of core material. Theoretical formula for determining buckling load is derived by Rayleigh-Ritz method and compared with experimental result. The maximum length of specimen that buckling does not occur is determined by assuming that the compression load is sustained by only face material. In the experiment, if buckling occurs obviously then it follows the theoretical result well. In the process of buckling, the load supporting capability and the antenna property such as radiation pattern and reflection coefficient were examined.

  • PDF

자동차 클러치 다이어프램 스프링 하중 특성 및 민감도 해석 (Load Characteristics and Sensitivity Analysis for an Automotive Clutch Diaphragm Spring)

  • 이병수
    • 한국자동차공학회논문집
    • /
    • 제14권1호
    • /
    • pp.54-59
    • /
    • 2006
  • An analytical solution for deflection-load characteristics of a conical disk spring used especially in the automotive manual transmission clutch applications is proposed in order to take into account the effects of friction and large deformation. The conical disk spring, or the diaphragm spring, has a hinge support, an application point of release load at the tip of the fingers and an application point of clamp load near but inside the outer perimeter of the conical disk spring. The friction coefficient is assumed to be a constant regardless of the speed of deflection and the magnitude of loads. Comparison with experimental shows a good agreement with the analytical prediction. Also, the sensitivity of the clamp load due to variations in the geometrical parameters of the conical disk spring is calculated and discussed.

온도특성에 대한 데이터 정제를 이용한 제주도의 단기 전력수요 예측 (Short-term Load Forecasting of Using Data refine for Temperature Characteristics at Jeju Island)

  • 김기수;송경빈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.225-228
    • /
    • 2008
  • The electricity supply and demand to be stable to a system link increase of the variance power supply and operation are requested in jeju Island electricity system. A short-term Load forecasting which uses the characteristic of the Load is essential consequently. We use the interrelationship of the electricity Load and change of a summertime temperature and data refining in the paper. We presented a short-term Load forecasting algorithm of jeju Island and used the correlation coefficient to the criteria of the refining. We used each temperature area data to be refined and forecasted a short-term Load to an exponential smoothing method.

  • PDF

지하철 역사의 구조 및 특성을 고려한 동력부하밀도 분석 (Power Load Density Analysis considering Structure and Characteristics of Subway Stations)

  • 정현기;차광석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.912-920
    • /
    • 2006
  • The purpose of this study is to present the design standard for load density in subway station. From the data of electric equipment capacity and electric power consumption for 43 subway stations, current levels of the load density and excess capacity factor were surveyed and analyzed, In addition mean value, standard deviation, maximum value, median value and correlation coefficient were evaluated through excel program. Also it was carried out the regression analysis. The estimation method of load density and design criterion were studied. As a result, load density in this thesis have been proposed : 51.3 $[VA/m^2]$ on the general power load can be a standard value for subway station.

  • PDF

기존선에서 가설교량 시공에 따른 열차의 주행안전성 평가 (Evaluation of Train Running Safety During Construction of Temporary Bridge on Existing Railway)

  • 엄기영;배재형;최찬용
    • 한국철도학회논문집
    • /
    • 제14권3호
    • /
    • pp.234-239
    • /
    • 2011
  • 선로하부를 굴착한 후의 가설교량 설치공법은 이동형 가로보를 갖는 공법으로 시공시 전차선 차단 및 레일절단이 불필요하고 열차운행 횟수가 많은 복선부에서도 적용 가능한 공법이다. 본 논문에서는 공사구간이 곡선부(R400)구간으로 가설교량 공법 시공 후의 변위특성을 검토하기 위해 변위계를 설치하고 열차 통과 시의 윤중 횡압을 계측하여 곡선부(R400)의 주행안전성 검토를 평가하였다. 측정결과 가설교량을 통과시 열차종별 윤중과 횡압의 최대값은 각각 국외 궤도성능평가 기준의 51%, 81% 수준으로 분석되어 윤중, 횡압 발생에 따른 궤도 안전성 측면에서는 큰 문제가 없을 것으로 판단된다. 또한 주행안전성의 평가기준이 되는 최대 탈선계수와 최대 윤중감소율은 열차종별에 관계없이 허용한계치의 49% 수준으로 그 기준치에는 못 미치는 것으로 나타나 열차 통과시의 주행안전성 확보에는 큰 문제가 없는 것을 알 수 있었다.