• Title/Summary/Keyword: load balance

Search Result 566, Processing Time 0.025 seconds

The Incipient Deformation Analysis for Plane Strain Open-Die Forging Processes with V-shaped Dies Using the Force Balance Method (힘평형법을 이용한 V-형다이 평면변형 자유형 단조공정의 초기변형 해석)

  • Lee, J.H.;Kim, B.M.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.4
    • /
    • pp.109-117
    • /
    • 1993
  • Force balance method is employed to predict forging information such as forging load, tool pressure and normal stress at the surface of tangential velocity discontinuity. The incipient stages of deformation for the plane strain forging of rectangular billets in V-shaped dies of different semi-angles are analysed. To construct an approximate model for the analysis of deformation by the force balance method in the incipient deformation stages, slip-line field is used. When the deformation mode by slip-line method is the same as that by force balance method, the slip-line method and the force balance method give identical solutions. The effects of die angle, coefficient of friction, billet geometries and deforma- tion characteristics are also investigated. In order to verify the validity of force balance analysis, the rigid-plastic finite element simulation for the various forgig parameters are performed and performed and find to be in good agreement.

  • PDF

Components of wind -tunnel analysis using force balance test data

  • Ho, T.C. Eric;Jeong, Un Yong;Case, Peter
    • Wind and Structures
    • /
    • v.18 no.4
    • /
    • pp.347-373
    • /
    • 2014
  • Since its development in the early 1980's the force balance technique has become a standard method in the efficient determination of structural loads and responses. Its usefulness lies in the simplicity of the physical model, the relatively short records required from the wind tunnel testing and its versatility in the use of the data for different sets of dynamic properties. Its major advantage has been the ability to provide results in a timely manner, assisting the structural engineer to fine-tune their building at an early stage of the structural development. The analysis of the wind tunnel data has evolved from the simple un-coupled system to sophisticated methods that include the correction for non-linear mode shapes, the handling of complex geometry and the handling of simultaneous measurements on multiple force balances for a building group. This paper will review some of the components in the force balance data analysis both in historical perspective and in its current advancement. The basic formulation of the force balance methodology in both frequency and time domains will be presented. This includes all coupling effects and allows the determination of the resultant quantities such as resultant accelerations, as well as various load effects that generally were not considered in earlier force balance analyses. Using a building model test carried out in the wind tunnel as an example case study, the effects of various simplifications and omissions are discussed.

Instantaneous Current Control for Parallel Inverter with a Current Share Bus (전류공유버스를 이용한 병렬 인버터 순시 제어기 설계)

  • 이창석;김시경
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.90-94
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employes active and reactive power control or frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employes a instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Futhermore, the proposed control scheme is verified through the simulation in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF

A Current Sharing Circuit for the Parallel Inverter

  • Lee, Chang-Seok;Kim, Si-Kyung
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.176-181
    • /
    • 1998
  • The parallel inverter is popularly used because of its fault-tolerance capability, high-current outputs at constant voltages and system modularity. The conventional parallel inverter usually employs active and reactive power control of frequency and voltage droop control. However, these approaches have the disadvantages that the response time of parallel inverter control is slow against load and system parameter variation to calculate active, reactive power, frequency and voltage. This paper describes a novel control scheme for power equalization in parallel-connected inverter. The proposed scheme has a fast power balance control response, a simplicity of implementation, and inherent peak current limiting capability since it employees an instantaneous current/voltage control with output voltage and current balance and output voltage regulation. A design procedure for the proposed parallel inverter controller is presented. Furthermore, the proposed control scheme is verified through the experiment in various cases such as the system parameter variation, the control parameter variation and the nonlinear load condition.

  • PDF

A Case Study for Development of the Block Arrangement on Fixed Area and Scheduling System (고정 정반에서의 블록 배치 및 일정계획 시스템 개발 사례연구)

  • Min Sang-Gyu;Lee Sang-Hyup;Kim Ji-On;Ha Seung-Jin;Choi Tae-Hoon
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2005.06a
    • /
    • pp.159-164
    • /
    • 2005
  • In this paper, we study some problems of the scheduling on the fixed area in a shipbuilding. The scheduling, constrainted a working area, is not easy to make a load balance and to operate a change of daily work plan. we proposed a block arrangement algorithm to make the load balance and developed a system used to operate the change of daily work plan.

  • PDF

The effect of Anticipatory Postural Adjustment on Balance Performance in Postural Disturbance (자세동요에 있어 선행적 자세적응이 균형수행력에 미치는 영향)

  • Chae Yun-Won;Kim Myung-Hoon;Cho Byeong-Mo
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.1
    • /
    • pp.65-71
    • /
    • 2000
  • This study investigated the effect of anticipatory postural adjustment on balance performance in postural disturbance. Any action performed by standing subject is generally accompanied by compensatory postural activities, which reduce or abolish the postural disturbance generated by the movement and keep the subjects' center of gravity within the supporting base. These Postural activities arc triggered by either anticipatory and feedback postural control. We studied the difference of anticipatory and feedback postural control in postural disturbance. The subjects were standing on a foot plate with eyes closed, holding a lead of $5\%$ of their own body weight in their hands. The condition of anticipatory postural adjustment was applied voluntarily releases the a load. The condition of feedback postural control was applied that the load was unpredictably removed. We concluded that anticipatory postural adjustment becomes more efficient to postural performance in postural disturbance.

  • PDF

A Study on the Development of Measuring Equipment for Coefficient of Earth Pressure at Rest (정지토압계수의 측정장치 개발에 관한 연구)

  • Song, Mu-Hyo
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.2 s.32
    • /
    • pp.159-167
    • /
    • 1999
  • For exisiting $K_0$-oedometer, the lateral wall of the ring is cut thinly to make space and by filling the space with space with water or mercuty to keep the balance to the lateral pressure of a specimen, the pressure of the fluid is checked for the pressure of the specimen. But the devices to keep the balance to the lateral pressure of a specimen are complicated, difficult to manufacture and expensive. As newly developed $K_0$-oedometer is equipped with the load cell which can resist higher pressute than the lateral pressure of the specimen, there is nearly no deformation due to the lateral pressure of the specimen. And the measuting is cheap and easy as there are fewer accessories.

  • PDF

A Study on Photovoltaic/Wind/Diesel Hybrid Power System

  • Jeong, Byung-Hwan;Cho, Jun-Seok;Gho, Jae-Seok;Choe, Gyu-Ha;Kim, Eung-Sang;Lee, Chang-Sung
    • Journal of Power Electronics
    • /
    • v.3 no.1
    • /
    • pp.40-48
    • /
    • 2003
  • In this paper, a hybrid power system with photovoltaic/wind/diesel generators is proposed to solve the defect of stand-alone type power system in a remote area. A hybrid power system has a power-balanced controller to equilibrate generation power with a given load demand and which is composed of common DC power system. To execute a power-balanced control, a hybrid power system is assumed that all of power generators have the characteristics of an equivalent current-source and load sharing control technique must be needed at the same time. So this paper discusses the structure of power-balance control for hybrid power system. And through the results of simulation, the proposed scheme was verified.

Load Distribution Method based on Transcoding Time Estimation on Distributed Transcoding Environments (분산 트랜스코딩 환경에서 트랜스코딩 시간 예측 기반 부하 분산 기법)

  • Kim, Jong-Woo;Seo, Dong-Mahn;Jung, In-Bum
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.37 no.4
    • /
    • pp.195-204
    • /
    • 2010
  • Due to improved wireless communication technologies, it is possible to provide multimedia streaming service for mobile device clients like PDAs and cellphones. Wireless networks are serviced on low bandwidth channels and mobile devices work on limited hardware specifications. In these conditions, transcoding technologies are needed to adapt the media for streaming services to given mobile environments. To transcode from the source media to the target media for corresponding grades, transcoding servers perform transcoding jobs as exhausting their resources. Since various transcoding loads occur according to the target transconding grades, an effective transcoding load balancing policy is required among transcoding servers. In addition to transcoding process, servers should maintain QoS streams for mobile clients for total serviced times. It requires real-time requirements to support QoS for various mobile clients. In this paper, a new transcoding load distribution method is proposed. The proposed method can be driven for fair load balance between distributed transcoding servers. Based on estimated transcoding time, movie information and target transcoding bit-rate, it provides fair transcoding load distribution and also performs admission control to support QoS streams for mobile clients.

Effect on Improvement of Muscle Strength Imbalance according to Load Deviation Pattern of Left and Right Arms in Upper Limbs (상지 좌우 운동부하 편차방식이 근력 불균형 개선에 미치는 영향)

  • Kang, Seung-Rok;Seo, Shin-Bae;Jeong, Gu-Young;Bae, Jong-Jin;Yu, Chang-Ho;Yu, Mi;Moon, Dong-An;Jeong, Jang-Sik;Kwon, Tae-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.9
    • /
    • pp.1026-1034
    • /
    • 2012
  • The purpose of this study was to verify the validation of effect on improvement of muscle strength unbalance according to exercise load deviation during rowing exercise. We performed evaluation of muscular activity and joint torque before the test. We recruited twenty subjects who one side's muscle strength is bigger in more 20% than other side. Subjects divided two groups. One is dominant left side and the other was dominant right side. Subjects performed rowing exercise in electric load deviation rowing equipment (Robo.gym, Humonic Co., Ltd., Daegu, Korea). Exercise performed four sets a day including 25 times a set, and three days a week. Measurements consist of evaluation of muscular activity and joint torque. Exercise load deviation adapted that different value of muscle strength in both arms multiplied 1RM% and added 1RM 50%. The results in adapted load deviation showed that the differences of maximal peak torque in 22.75% were getting increase significantly during exercise in 5.72%. This interpreted that rowing exercise with loading deviation types could provide muscle strength and muscular endurance exercise in same time for balance. Our study found out that loading deviation could provide muscle strength and muscular endurance exercise for improving muscle unbalance.