• Title/Summary/Keyword: load and resistance factors

Search Result 232, Processing Time 0.028 seconds

A Numerical Investigation on Restrained High Strength Q460 Steel Beams Including Creep Effect

  • Wang, Weiyong;Zhang, Linbo;He, Pingzhao
    • International journal of steel structures
    • /
    • v.18 no.5
    • /
    • pp.1497-1507
    • /
    • 2018
  • Most of previous studies on fire resistance of restrained steel beams neglected creep effect due to lack of suitable creep model. This paper presents a finite element model (FEM) for accessing the fire resistance of restrained high strength Q460 steel beams by taking high temperature Norton creep model of steel into consideration. The validation of the established model is verified by comparing the axial force and deflection of restrained beams obtained by finite element analysis with test results. In order to explore the creep effect on fire response of restrained Q460 steel beams, the thermal axial force and deflection of the beams are also analyzed excluding creep effect. Results from comparison infer that creep plays a crucial role in fire response of restrained steel beam and neglecting the effect of creep may lead to unsafe design. A set of parametric studies are accomplished by using the calibrated FEM to evaluate the governed factors influencing fire response of restrained Q460 steel beams. The parametric studies indicate that load level, rotational restraint stiffness, span-depth ratio, heating rate and temperature distribution pattern are key factors in determining fire resistance of restrained Q460 steel beam. A simplified design approach to determine the moment capacity of restrained Q460 steel beams is proposed based on the parametric studies by considering creep effect.

A study on the Fault Location Technique for Transmission Line System (송전선로의 고장점 표정기법에 관한 연구)

  • Kim, S.R.;Park, C.W.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.255-257
    • /
    • 2001
  • This paper describes an accurate fault location algorithm based on current distribution factors. To prove the effectiveness of proposed method, we used by simulation data from EMTP. The proposed algorithm using the current distribution factors is independent of fault resistance and load flow variation.

  • PDF

A Study on LRFD Reliability Based Design Criteria of RC Flexural Members (R.C. 휨부재(部材)의 L.R.F.D. 신뢰성(信賴性) 설계기준(設計基準)에 관한 연구(研究))

  • Cho, Hyo Nam
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.21-32
    • /
    • 1981
  • Recent trends in design standards development in some European countries and U.S.A. have encouraged the use of probabilistic limit sate design concepts. Reliability based design criteria such as LSD, LRFD, PBLSD, adopted in those advanced countries have the potentials that they afford for symplifying the design process and placing it on a consistent reliability bases for various construction materials. A reliability based design criteria for RC flexural members are proposed in this study. Lind-Hasofer's invariant second-moment reliability theory is used in the derivation of an algorithmic reliability analysis method as well as an iterative determination of load and resistance factors. In addition, Cornell's Mean First-Order Second Moment Method is employed as a practical tool for the approximate reliability analysis and the derivation of design criteria. Uncertainty measures for flexural resistance and load effects are based on the Ellingwood's approach for the evaluation of uncertainties of loads and resistances. The implied relative safety levels of RC flexural members designed by the strength design provisions of the current standard code were evaluated using the second moment reliability analysis method proposed in this study. And then, resistance and load factors corresponding to the target reliability index(${\beta}=4$) which is considered to be appropriate level of reliability considering our practices are calculated by using the proposed methods. These reliability based factors were compared to those specified by our current ultimate strength design provisions. It was found that the reliability levels of flexural members designed by current code are not appropriate, and the code specified resistance and load factors were considerably different from the reliability based resistance and load factors proposed in this study.

  • PDF

Target Reliability Index and Load-resistance Factors for the Gravitational Loads-governed Limit States for a Reliability-based Bridge Design Code (신뢰도기반 교량설계기준의 중력방향하중 지배 한계상태에 대한 목표신뢰도지수 및 하중-저항계수)

  • Kim, Jeong-Gon;Kim, Ho-Kyung;Lee, Hae Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.299-309
    • /
    • 2022
  • This paper presents a new class of the vehicular live load factor for a reliability-based bridge design code. The significance of the current vehicular live load factor of 1.8 is investigated based on the return period of the vehicular live load and the design life of a bridge. It is shown that the current vehicular live load factor corresponds to a return period of 6.7 million years for a 100-year design life, which seems to be unrealistic in an engineering sense, and that the target reliability of 3.72 is set to too high without any reasoning for the gravitational load-governed limit state compared with that of the other limit states. In case the same return period as the design wind velocity or the ground acceleration is employed for the vehicular live load, the corresponding vehicular live load factor becomes around 1.15, and the target reliability index for the return period may be selected as 2.0 or 2.5 depending on the governing load effect. The complete sets of the load-resistance factors for the proposed target reliability indices are evaluated through optimization.

Evaluation of Response Modification Factors for Shear Wall Apartment Building (벽식 APT의 반응수정계수 추정에 관한 연구)

  • 송정원;송진규;이수곤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.859-864
    • /
    • 2001
  • For earthquake resistance design, a response modification factor is used to reduce the design strength and it reflects ductility, reserve strength, redundancy and damping effect. But this factor has not theoretical basis. In this study, two response modification factors are compared and analyzed for shear wall apartment building.; the one is introduced by ATC-19 Procedures, the other is suggested FEMA-273 and ATC-40 through nonlinear static analysis. For the results, ATC-19 procedure gives a reasonable estimation to R factor. But $R_{u}$ by using FEAM-273 and ATC-40 methods is estimated so small in case of a minor or moderate earthquake region. Due to this fact, response modification factor is smaller than suggested load criterion 3.0. So, it needs to decrease wall volume and reduce the global strength and system stiffness for proper ductile behavior matching to domestic load criterion.

  • PDF

Shear Behavior between Ground and Soil-Nailing (지반과 쏘일네일링 사이의 전단거동에 관한 연구)

  • Seo, Hyung-Joon;Lee, In-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.3
    • /
    • pp.5-16
    • /
    • 2014
  • Soil-nailing has two main resistance factors: skin friction between ground and grouting; and tension load of reinforced material. These two factors will affect the load-displacement curve when performing soil-nailing pullout tests. The purpose of this paper is to figure out the shear behavior between ground and soil-nailing focusing on the net load-displacement behavior during soil-nailing pullout tests. Firstly, the net load-displacement curve between ground and grouting is estimated theoretically. Then, in-situ pullout load tests are performed on various ground conditions to obtain the load-displacement curve occuring between ground and grouting. Since the measured shear displacement includes elongation of the reinforced material (steel nails), the net load-displacement curve can be obtained by subtracting the elongation magnitude of steels from the measured displacement. It was found that the measured net load-displacement curve matches reasonably well with the theoretically estimated curve.

Durability Improvement of Engine Bulkhead by Adjusting Design Parameters (설계인자변화에 따른 엔진 벌크헤드 내구성 향상)

  • Yang, Chull-Ho;Han, Moon-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.2
    • /
    • pp.111-116
    • /
    • 2011
  • Three-dimensional finite element analyses have been performed to improve the durability of bulkhead. To keep pace with design changes and concentrate on regions of interest, SUBMODEL technique in ABAQUS was used for analysis. An analysis was conducted with following load cases: 1) Cap press-fit, 2) Bearing crush, 3) Bolt assembly, 4) Hot assembly, 5) Firing load, 6) Alternating firing load, 7) 2nd hot assembly. Fatigue analysis was done using commercial software FEMFAT and fatigue factors at the interested regions such as bolt tip area, counter bore, breathing hole, honing clearance were calculated and compared to aid design validation. Finite element modeling in the area of thread engagement used a simple constraint equations. Increasing bolt length, to a minimum of 39 mm above joint face gives a better fatigue resistance to the bulkhead. Breathing hole helps not only circulate the air in the crankcase but also fatigue resistance of bulkhead by relieving the stress at the critical locations.

Estimation of the Behavior of a Micropile due to Horizontal Load (횡방향 하중에 의한 마이크로파일의 거동 평가)

  • Lee, Seongmin;Baek, Seungcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.6
    • /
    • pp.117-123
    • /
    • 2009
  • The mechanical behavior of a micropile due to horizontal load has not yet clearly identified in Korea. It has generally estimated from that of a traditional pile because there is no standard method even though it has shorter length. To tell the truth, its behavior is very different from a traditional pile's. Specifically, it is general fact that horizontal resistance of earth is one of the main factors to control the mechanical behavior of micropile. To this reason, a laboratory model has been made in this study to estimate the behavior of a micropile which loaded increasingly horizontally. The laboratory model has been designed to estimate both the behavior of load to displacement and skin friction to displacement. And the analysis of the latter was compared with the solution of strain wedge model. In the end, it was proved that the mechanical behavior of a micropile should be estimated from considering the horizontal resistance of earth.

  • PDF

Progressive Collapse of Steel High-Rise Buildings Exposed to Fire: Current State of Research

  • Jiang, Jian;Li, Guo-Qiang
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.375-387
    • /
    • 2018
  • This paper presents a review on progressive collapse mechanism of steel framed buildings exposed to fire. The influence of load ratios, strength of structural members (beam, column, slab, connection), fire scenarios, bracing systems, fire protections on the collapse mode and collapse time of structures is comprehensively reviewed. It is found that the key influencing factors include load ratio, fire scenario, bracing layout and fire protection. The application of strong beams, high load ratios, multi-compartment fires will lead to global downward collapse which is undesirable. The catenary action in beams and tensile membrane action in slabs contribute to the enhancement of structural collapse resistance, leading to a ductile collapse mechanism. It is recommended to increase the reinforcement ratio in the sagging and hogging region of slabs to not only enhance the tensile membrane action in the slab, but to prevent the failure of beam-to-column connections. It is also found that a frame may collapse in the cooling phase of compartment fires or under travelling fires. This is because that the steel members may experience maximum temperatures and maximum displacements under these two fire scenarios. An edge bay fire is more prone to induce the collapse of structures than a central bay fire. The progressive collapse of buildings can be effectively prevented by using bracing systems and fire protections. A combination of horizontal and vertical bracing systems as well as increasing the strength and stiffness of bracing members is recommended to enhance the collapse resistance. A protected frame dose not collapse immediately after the local failure but experiences a relatively long withstanding period of at least 60 mins. It is suggested to use three-dimensional models for accurate predictions of whether, when and how a structure collapses under various fire scenarios.

Characteristics of Stock Drainage Depending on Refining Load and Analysis of Drainage Factors (고해하중변화에 의한 탈수성과 탈수영향 인자 분석)

  • 장현성;박종문
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.2
    • /
    • pp.10-16
    • /
    • 2004
  • Structures and strengths of paper have been studied by analyzing fibers characteristics depending on refining methods. Mixing ratio of softwood and hardwood fibers and fibers characteristics have been analyzed for paper quality improvement. In this study flocculation and drainage of fibers were analyzed to improve the production efficiency and paper product's quality. Floc size and drainage rate depending on stock consistency and fines content were analyzed. Total amount of drainage during drainage process was measured quantitatively by using DI(drainage index). Floc size, viscosity of floc and dewatering times were also measured. In the case of refining load $2.8 kg_f$ , drainage was occurred by filtration mechanism rather than thickening mechanism because drainage resistance increased by fibrillation of fibers. Therefore, the drainage rate of $2.8 kg_f$ refining load stock was slower than that of $5.6 kg_f$.