• 제목/요약/키워드: liquid chromatography mass spectrometry

검색결과 888건 처리시간 0.024초

LC-MS/MS를 이용한 농경지 토양 중 항생제 모니터링 (Monitoring of Veterinary Antibiotics in Agricultural Soils using Liquid Chromatography Coupled with Tandem Mass Spectrometry)

  • 이영준;최정희;정형석;이한솔;박병준;김장억;심재한
    • 한국환경농학회지
    • /
    • 제35권3호
    • /
    • pp.166-174
    • /
    • 2016
  • 농경지 토양에서 대상항생제 6종(amoxicillin, ampicillin, chlortetracycline, enrofloxacin, oxytetracycline, tetracycline을 아세트산 함유 아세토니트릴, Na2Cit.5H2O, Na3Cit.2H2O과 Na2-EDTA로 추출 후 C18으로 정제하여 LC-MS/MS로 분석하는 모니터링을 수행하였다. 그 중 2종의 항생제, chlortetracycline과 enrofloxacin이 국내 농경지 토양에서 검출되었다. 제안한 분석법은 토양 중 잔류 항생제 모니터링을 위한 빠르고 간편한 시험법이었고 다양한 활용이 가능할 것으로 보인다.

LC-MS/MS를 이용한 수산물 중 콜리스틴 분석법 개발 (Development of Analytical Method for Colistin in Fish and Shrimp using Liquid Chromatography Mass Spectrometry)

  • 신다솜;강희승;이수빈;조윤제;천소영;정지윤;이규식
    • 한국식품위생안전성학회지
    • /
    • 제31권5호
    • /
    • pp.319-326
    • /
    • 2016
  • LC-MS/MS를 이용하여 폴리펩타이드계 동물용의약품인 콜리스틴에 대한 시험법을 확립하여 정량성 및 정밀성을 확보하였으며, 확립된 시험법의 적용성 검증을 위해 국제식품규격위원회 기준에 따라 특이성, 정확성, 직선성, 정밀성, 검출한계, 정량한계 등을 검증하였다. 콜리스틴 표준용액을 잔류허용기준의 농도에 따라 검량선을 작성한 결과 0.99 이상의 직선성을 확인 할 수 있었으며, 본 실험에서의 평균 회수율은 85.9~107%이었다. 또한, 분석오차는 11.8% 이하로 정확성 및 재현성이 우수하였으며, 검출한계는 0.02 mg/kg, 정량한계는 0.05 mg/kg이었다. 또한, 실험실간 교차검증을 통하여 신뢰성을 확보하였다. 확립된 분석법은 양식 수산물 중 잔류할 수 있는 동물용의약품인 콜리스틴에 대한 안전관리에 활용 할 수 있을 것으로 판단된다.

HPLC-MS/MS를 이용한 트리클로로에틸렌 대사산물의 다중 분석법 확립 (Multiple Determinations of Trichloroethylene Metabolites in a Concurrent Biological Media using High Performance Liquid Chromatography Coupled with Tandem Mass Spectrometry)

  • 안영아;고영림;이승호;신미연;전중대;김성균
    • 한국환경보건학회지
    • /
    • 제40권2호
    • /
    • pp.114-126
    • /
    • 2014
  • Objectives: We aimed to develop a measurement method of five metabolites of trichloroethylene (TCE) in a concurrent biological sample, e.g., trichloroacetic acid (TCA), dichloroacetic acid (DCA), S-(1,2-dichlorovinyl) glutathione (DCVG), S-(1,2-dichlorovinyl)-L-cysteine (DCVC), and N-Acetyl-S-(1,2-dichlorovinyl)-L-cysteine (NAcDCVC) and to validate the method before application to pharmacokinetic study. Methods: TCE metabolites were simultaneously analyzed using high performance liquid chromatography coupled with electrospray ionization mass spectrometry (HPLC-ESI-MS/MS) with as little as 50 ${\mu}L$ of serum and urine. DCA, TCA and NAcDCVC were extracted with diethyl ether, while DCVC and DCVG were extracted by solid phase extraction. This method was validated according to the guidelines for bioanalytical method validation of the Korean National Institute of Toxicological Research. Then, we determined the five metabolites in five strains of mice at 24 hr after exposure to 1 g TCE /kg body weight. Results: The limits of detection for the five metabolites in biological samples ranged from 0.001 to 0.076 nmol/mL, which is comparable to or better than those previously reported. Most calibration curves showed good linearity ($R^2=0.99$), and between-batch variation was less than 20% expressing acceptable robustness and reproducibility. Using this method, we found TCA and DCA were detected in all test mice at 24 hr after the oral administration while NAcDCVC and DCVC were detected in some strains, which showed strain-dependent metabolism of TCE. Conclusions: The present method could provide robust and accurate measurements of major key metabolites of TCE in biological media, which allowed concurrent analysis of TCE metabolism for limited amounts of biospecimens.

The development and validation of a novel liquid chromatography tandem mass spectrometry (LC-MS/MS) procedure for the determination of fluoroquinolones residues in chicken muscle using modified QuEChERS (quick, easy, cheap, effective, rugged and safe) method

  • Park, Sunjin;Kim, Hyobi;Choi, Byungkook;Hong, Chung-Oui;Lee, Seon-Young;Jeon, Inhae;Lee, Su-Young;Kwak, Pilhee;Park, Sung-Won;Kim, Yong-Sang;Lee, Kwang-jick
    • 한국동물위생학회지
    • /
    • 제42권4호
    • /
    • pp.289-296
    • /
    • 2019
  • A novel rapid procedure with liquid chromatography tandem mass spectrometry (LC-MS/MS) detection has been developed by changing various conditions including sample preparation such as QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) methodology. This work has been involved the optimization and validation of detection method for fluoroquinolones which are widespread used in livestock especially in the chicken. Five grams of homogenized chicken muscle were extracted with QuEChERS EN and acetonitrile containing 5% formic acid and cleaned with anhydrous magnesium sulfate and C18 sorbent. The separation was performed on Acquity UPLC HSS T3 (2.1 mm×100 mm, 1.8 ㎛) column. The mobile phase A and B were composed of water containing 0.1% formic acid and acetonitrile containing 0.1% formic acid, respectively. Flow rate was 0.25 mL/min and column temperate was 40℃. LC-MS/MS with multiple reaction monitoring has been optimized for ten fluoroquinolones (ciprofloxacin, danofloxacin, difloxacin, enrofloxacin, marbofloxacin, norfloxacin, ofloxacin, orbifloxacin, pefloxacin and sarafloxacin). The method developed in this study has been presented good linearity with correlation coefficient (R2) of 0.9971~0.9998. LOD and LOQ values ranged from 0.09 to 0.76 ppb and from 0.26 to 2.29 ppb, respectively. The average recoveries were from 77.46 to 111.83% at spiked levels of 10.0 and 20.0 ㎍/kg. Relative standard deviation (%) ranged 1.28~11.90% on intra-day and 3.10~8.38 % on inter-day, respectively. This analysis method was applicable to the livestock residue laboratories and was expected to be satisfactory for the residue surveillance system.

LC-MS/MS를 이용한 소변 중 크레아티닌 분석의 측정불확도 평가 (Uncertainty evaluation for the determination of creatinine in urine by LC-MS/MS)

  • 김진영;권운용;서승일;인문교
    • 분석과학
    • /
    • 제25권1호
    • /
    • pp.83-90
    • /
    • 2012
  • 소변 중 크레아티닌의 정상적인 농도범위는 30 - 300 mg/dL로 마약류 감정에 앞서 크레아티닌농도를 측정함으로써 소변 시료의 유효성을 확인하고 있다. 크레아티닌 농도 측정을 위해 액체크로마토그래피-질량분량분석법(LC-MS/MS, liquid chromatography-tandem mass spectrometry)을 사용하였다. 우선 소변 시료를 고속으로 원심분리한 후 10 ${\mu}L$를 분취하여 증류수 390 ${\mu}L$와 혼합하여 희석하였다. 희석된 시료 20 ${\mu}L$에 내부표준물질(5 ${\mu}g/mL$) 30 ${\mu}L$와 acetonitrile 10 ${\mu}L$를 첨가하여 혼합한 후 여과한 시료를 LC-MS/MS에 주입하였다. 크레아티닌은 multi-mode ODS column (Scherzo SM-C18, 75 ${\times}$ 2.0 mm, I.D. 3 ${\mu}m$)을 이용하여 분리하였고, 이동상은 0.2% formic acid와 acetonitrile로 구성되었으며 유속은 150 ${\mu}L$/min으로 하였다. 크레아티닌과 내부표준물질은 [M+H]$^+$ precursor ion과 특징적인 product ion을 한 쌍으로 m/z 114.0${\rightarrow}$ 86.0과 m/z 117.0${\rightarrow}$ 89.1에서 모니터링하여 정량에 적합한 크로마토그램을 얻을 수 있었다. 측정불확도 평가에 앞서 정량분석시 측정값에 영향을 주는 인자들을 찾아내고 각각의 요소들이 측정결과에 어떤 영향을 주는가를 살펴보았다. 시료 희석, 검정 곡선, 재현성, 표준물질의 인자 순으로 측정불확도에 영향을 미치고 있음을 확인하였다. 실제 사람의 소변에서 크레아티닌 농도를 측정한 결과, 측정값에 대한 오차 범위의 상대불확도는 14.2%로 산출되었다.

소변 중 디아민을 이용한 디이소시아네이트 노출 근로자의 생물학적 모니터링 (Biological Monitoring of Workers Exposed to Diisocyanates using Urinary Diamines)

  • 이종성;김부욱;신정아;백진이;신재훈;김지혜
    • 한국산업보건학회지
    • /
    • 제26권2호
    • /
    • pp.178-187
    • /
    • 2016
  • Objectives: Diisocyanates are a potent inducer of diseases of the airways, especially asthma. In this study, toluenediamine(TDA) and methylenedianiline(MDA) in urine were evaluated as biomarkers of exposure to tolunenediisocyanate(TDI) and methylenediphenyl diisocyanate(MDI), respectively. Methods: Workers exposed to TDI and MDI, as well as non-occupationally exposed subjects, were studied and pre- and post-shift urine samples were collected from 8 control subjects and 8 workers from a factory which manufactures polyurethane products for reducing noise and vibration in automobiles. Airborne TDI and MDI(n=8) were sampled on solvent-free glass filters impregnated with n-butylamine and detected by liquid chromatography atmospheric pressure ionization tandem mass spectrometry. Urinary TDA and MDA were detected as pentafluoropropionic acid anhydride(PFPA) derivatives by liquid chromatography electrospray ionization tandem mass spectrometry. Results: The median levels of urinary 2,6-TDA(p<0.001), 2,4-TDA(p=0.001), and MDA(p<0.001) of workers in post-shift samples were significantly higher than those of controls. The median levels of urinary 2,6-0TDA($0.63{\mu}g/g$ creatinine vs $0.34{\mu}g/g$ creatinine, p=0.017) and MDA($4.21{\mu}g/g$ creatinine vs $3.18{\mu}g/g$ creatinine, p=0.017) of workers in post-shift samples were significantly higher than those of the pre-shift samples. There were significant correlations between the urinary 2,6-TDA, 2,4-TDA, and MDA of workers in post-shift samples and the airborne 2,6-TDI(rho=0.952, p<0.001), 2,4-TDI(rho=0.833, p=0.001), and MDI(rho=0.952, p<0.001). Conclusions: These urinary diamines, metabolites of diisocyanates, in post-shift samples were useful biomarkers to assess occupational exposure to diisocyanates.

동위원소 희석 HPLC/MS에 의한 혈청 내 urea의 정량 (Quantification of urea in serum by isotope dilution HPLC/MS)

  • 이화심;박상열
    • 분석과학
    • /
    • 제18권4호
    • /
    • pp.271-277
    • /
    • 2005
  • 혈액 내 urea는 임상진단 시 신장 기능을 판단하는 중요한 표지물질로서 측정되고 있다. 단백질 등 질소화합물의 최종 대사물인 urea는 콩팥의 사구체에서 걸러져 소변으로 배출되는데, 사구체의 거르는 능력이 저하되면 결국 혈액 속의 urea 농도가 증가하게 되어 신장 기능의 정상여부를 판단할 수 있게 된다. 이러한 임상진단 결과의 신뢰성 향상을 위해서는 측정결과가 일차분석법으로 인증된 인증표준 물질과 소급성 고리를 유지해야 한다. 본 연구에서는 혈청 내 urea의 일차분석법으로서 $15^N_2$-urea를 내부 표준물질로 사용하는 동위원소희석 액체크로마토그라피-질량분석법 (ID-HPLC/MS)을 개발하였다. 이 방법은 측정원리상 고도의 정확성이 확보될 뿐 아니라 별도의 유도체화가 필요 없기 때문에 빠르고 편리하다. $C_{18}$-분리관에 0.1 mmol/L $NH_4Cl$ buffer를 이동상으로 사용하여 urea를 분리하였는데, 이 완충용액은 비교적 분자량이 작은 urea를 질량분석하는데 방해가 크지 않은 장점이 있다. HPLC와 질량분석기의 인터페이스로서 positive mode의 electrospray ionization (ESI)를 사용하여 높은 감도와 재현성을 성취하였다. 국제적으로 인정된 인증표준물질의 분석을 통해 최적화된 방법의 유효성을 확인하였으며, 국제비교시험에도 참여하여 좋은 결과를 얻었다. ISO guide에 따라 불확도를 계산하였으며, 확장 불확도는 95% 신뢰도에서 약 1.8%로 나타났다. 이 분석법은 표준연에서 개발 중인 혈청인증표준물질을 인증하는 일차기준측정절차로도 사용되고 있다.

Bioequivalence of Samchundang Lercanidipine Tablet 10 mg to Zanidip Tablet (Lercanidipine Hydrochloride 10 mg) by Liquid Chromatography with Tandem Mass Spectrometry

  • Kim, Se-Mi;Kim, Hwan-Ho;Shin, Sae-Byeok;Kang, Hyun-Ah;Cho, Hea-Young;Kim, Yoon-Gyoon;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권5호
    • /
    • pp.315-321
    • /
    • 2007
  • The purpose of the present study was to evaluate the bioequivalence of two lercanidipine hydrochloride tablets, Zanidip tablet (LG Life Sciences Ltd., Korea, reference drug) and Samchundang Lercanidipine tablet 10 mg (Sam Chun Dang Pharm. Co. Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). After adding an internal standard (amlodipine maleate) to human serum, serum samples were extracted using hexan-isoamyl alcohol (100:1, v/v). Compounds were analyzed by liquid chromatography/tandem mass spectrometry. This method showed linear response over the concentration range of 0.05-20 ng/mL with correlation coefficient of 0.9999. The lower limit of quantitation using 0.5 mL of serum was 0.05 ng/mL which was sensitive enough for pharmacokinetic studies. Thirty healthy male Korean volunteers received each medicine at the lercanidipine hydrochloride dose of 20 mg in a $2\;{\times}\;2$ crossover study. There was a one-week washout period between the doses. Serum concentrations of lercanidipine were monitored by an LC/MS/MS fer over a period of 24 hr after the administration. $AUC_t$ (the area under the serum concentration-time curve from time 0 to 24 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (the maximum serum drug concentration) and $T_{max}$ (the time to reach $C_{max}$) were compiled from the serum concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters, indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Samchundang Lercanidipine/Zanidip were log 0.9505-log 1.2258 and log 0.9987-log 1.2013, respectively. These values were within the acceptable bioequivalence intervals of log 0.80-log 1.25. Thus, the criteria of the KFDA guidelines for the bioequivalence was satisfied, indicating Samchundang Lercanidipine tablet 10 mg and Zanidip tablet are bioequivalent.

해산물 시료에서 solid-phase extraction 및 HPLC-ICP/MS를 이용한 셀레늄 화학종의 정량분석 (Quantitative analysis of selenium species in sea food using solid phase extraction and HPLC-ICP/MS)

  • 김은주;주민규;권효식;박용남
    • 분석과학
    • /
    • 제26권5호
    • /
    • pp.307-314
    • /
    • 2013
  • 셀레늄은 다양한 화학종으로 존재하며 그 농도와 형태에 따라 활성도나 생물학적 이용도가 달라지므로 식품에 대한 셀레늄 화학종의 정확한 분리 및 정량이 필요하다. 본 연구에서는 역상 (RP; reversed phase) 고성능 액체 크로마토그래피 (HPLC; high performance liquid chromatography)와 유도결합 플라즈마 (ICP; inductively coupled plasma) 질량분석법 (MS; mass spectrometry)을 사용하여 해산물 시료 중 셀레늄 화학종을 분리 검출 한 뒤에 후 컬럼 동위원소희석법 (post column isotope dilution)으로 정확히 정량 하였다. 시료 중 $^{80}Se$의 간섭요인인 $^{79}Br$을 제거하기 위해 고체상 추출법을 사용하여 대부분의 $^{79}Br$을 제거하였고 남아있는 $^{79}Br$은 수학적 보정식을 이용하여 보정해주었다. CRM (certified reference material) DOLT-4를 사용하여 셀레늄의 총량을 분석한 결과는 인증치와 잘 일치하였지만 각 화학종에 대한 정보는 비교할 수 없었다. 한국인 식탁에 오르는 대표적인 해산물 시료인 갈치, 삼치, 오징어, 등을 분석한 결과, 주된 셀레늄 화학종은 SeCys (selenocysteine)와 SeMet (selenomethionine)이었으며 각각은 0-661.6 mg/kg and 137.3-462.7 mg/kg의 농도로 존재함 을 알 수 있었다.

LC-MS/MS 및 GC-MS/MS를 활용한 수산물 중 디아제팜의 정량분석법 개발 (Development of the Analytical Method for Diazepam in Fishery Products using Liquid and Gas Chromatography-tandem Mass Spectrometry)

  • 신다솜;강희승;김주혜;정지윤;이규식
    • 한국식품위생안전성학회지
    • /
    • 제33권2호
    • /
    • pp.110-117
    • /
    • 2018
  • 본 연구는 국내 생산 및 수입 양식 수산물에 대해 잔류할 수 있는 향정신성 의약품인 디아제팜 대한 안전관리강화기반을 위해 마련되었다. 중국인민공화국 국가 표준시험법(GB 29697-2013)을 기반으로 전처리 방법을 개선하여 GC-MS/MS 시험법을 확립하였으며, LC-MS/MS 방법과의 기기간 검증을 통해 확립된 시험법의 선택성, 정량한계 및 회수율에 대한 검증을 통해 디아제팜 시험법으로서의 유효성을 확인하였다. LC-MS/MS의 경우 아세토니트릴로 추출 후 PSA를 이용해 정제하였고, GC-MS/MS의 경우 아세토니트릴로 추출후 $C_{18}$카트리지를 이용해 정제하였다. 디아제팜은 표준용액을 정량한계를 포함한 농도에 따라 검량선을 작성한 결과 두 기기 모두 $r^2$> 0.99 이상의 직선성을 확인하였다. 본 실험에서의 검출한계와 정량한계는 LC-MS/MS 및 GC-MS/MS 모두 0.0004 mg/kg, 0.001 mg/kg 수준이었으며, 평균 회수율은 각각 99.8~106%, 109~124%이었다. 또한, 분석오차는 모두 15% 이하로 정확성 및 재현성이 우수하였으며, CODEX 가이드라인 규정에 만족하는 수준이었다. 따라서 개발된 시험법은 안전한 수산물의 국내 유통과 잔류실태조사를 위해 활용될 것으로 기대한다.