• 제목/요약/키워드: linear dynamic range

검색결과 270건 처리시간 0.027초

MR 유체와 압전스택을 특징으로하는 새로운 형태의 능동 엔진마운트 시스템 (A New Type of Active Engine Mount System Featuring MR Fluid and Piezostack)

  • 이동영;손정우;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.444-449
    • /
    • 2009
  • An engine is one of the most dominant noise and vibration sources in vehicle systems. Therefore, in order to resolve noise and vibration problems due to engine, various types of engine mounts have been proposed. This work presents a new type of active engine mount system featuring a magneto-rheological (MR) fluid and a piezostack actuator. As a first step, six degrees-of freedom dynamic model of an in-line four-cylinder engine which has three points mounting system is derived by considering the dynamic behaviors of MR mount and piezostack mount. In the configuration of engine mount system, two MR mounts are installed for vibration control of roll mode motion whose energy is very high in low frequency range, while one piezostack mount is installed for vibration control of bounce and pitch mode motion whose energy is relatively high in high frequency range. As a second step, linear quadratic regulator (LQR) controller is synthesized to actively control the imposed vibration. In order to demonstrate the effectiveness of the proposed active engine mount, vibration control performances are evaluated under various engine operating speeds (wide frequency range) and presented in time domain.

  • PDF

MR 유체와 압전스택을 특징으로 하는 새로운 형태의 능동 엔진마운트 시스템 (A New Type of Active Engine Mount System Featuring MR Fluid and Piezostack)

  • 이동영;손정우;최승복
    • 한국소음진동공학회논문집
    • /
    • 제19권6호
    • /
    • pp.583-590
    • /
    • 2009
  • An engine is one of the most dominant noise and vibration sources in vehicle systems. Therefore, in order to resolve noise and vibration problems due to engine, various types of engine mounts have been proposed. This work presents a new type of active engine mount system featuring a magneto-rheological (MR) fluid and a piezostack actuator. As a first step, six degrees-of freedom dynamic model of an in-line four-cylinder engine which has three points mounting system is derived by considering the dynamic behaviors of MR mount and piezostack mount. In the configuration of engine mount system, two MR mounts are installed for vibration control of roll mode motion whose energy is very high in low frequency range, while one piezostack mount is installed for vibration control of bounce and pitch mode motion whose energy is relatively high in high frequency range. As a second step, linear quadratic regulator (LQR) controller is synthesized to actively control the imposed vibration. In order to demonstrate the effectiveness of the proposed active engine mount, vibration control performances are evaluated under various engine operating speeds(wide frequency range) and presented in time domain.

A Method of Hysteresis Modeling and Traction Control for a Piezoelectric Actuator

  • Sung, Baek-Ju;Lee, Eun-Woong;Lee, Jae-Gyu
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권3호
    • /
    • pp.401-407
    • /
    • 2008
  • The dynamic model and displacement control of piezoelectric actuators, which are commercially available materials for managing extremely small displacements in the range of sub-nanometers, are presented. Piezoceramics have electromechanical characteristics that transduce energy between the electrical and mechanical domains. However, they have hysteresis between the input voltage and output displacement, and this behavior is very demanding and complicated. In this paper, we propose a method of designing the control algorithm, and present the dynamic modeling equations that represent the hysteretic behavior between input voltage and output displacement. For this process, the piezoelectric actuator is treated as a second-order linear dynamic system and system constants are determined by the system identification method. Also, a classical PID controller is designed and used to regulate the output displacement of the actuator. To evaluate the performance of the proposed method, numerical simulation results are presented.

칩 마운터용 리니어 모터의 열전달 해석 (Heat Transfer Analysis of a Linear Motor for Chip Mounter Applications)

  • 장창수;김종영;김영준;오정석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.396-401
    • /
    • 2001
  • Heat transfer analysis of a iron core type linear motor for surface mounting device applications was considered in this study. In order to avoid the complex conjugate problem a fluid flow regime and a solid regime were considered separately. First, film coefficients of the moving parts were evaluated from computational fluid dynamic analysis and those of the stationary parts from the existing empirical or analytic correlations. And then, by applying them, internal and external temperatures of the linear motor pal1s were computed through finite element analysis. Both computation and measurement were carried out with respect to motor driving power. The measurement did not exhibit a linear temperature variation trend with respect to motor power while the computation revealed a linear correlation. Nonetheless, the computations agreed with the measurements within an error range of 20%. It indicates that an adequate heat transfer model for the reciprocative coil assembly may help more exact prediction.

  • PDF

Dynamic SPME를 이용한 공기 중 지방산 분석 (Analysis of Volatile Fatty Acids in Air by Dynamic SPME)

  • 유미선;양성봉;하남기
    • 한국환경과학회지
    • /
    • 제19권12호
    • /
    • pp.1447-1454
    • /
    • 2010
  • In this study, the detection limits of lower fatty acids in air were investigated by using Dynamic SPME(Solid Phase Micro-Extraction), i.e. improved Head Space - SPME method(HS-SPME). This Dynamic SPME, called SPDE(Solid Phase Dynamic Extraction), is the analytical method for volatile compounds in air with the extraction by using a stainless steel needle of which inner surface is coated with adsorption material and following the gas chromatographic analysis by inserting the needle into a injection port of GC and subsequently, desorption of the volatile compounds into a gas-chromatographic column. Extraction was carried out by passing the sample air through the needle with a suction pump which has been used for a detection tube. The result of measurement for the 6 lower fatty acids showed that the detection limits ranged from 0.10 ppm to 0.44 ppm and the linear correlation coefficients were over 0.99. Relative standard deviations obtained from 5 analytical repetition of a ca. 1.6 ppm standard mixture were in the range of 1.87%~2.47%. This method has been shown to be a adequate for the measuring C2~C5 fatty acids in air in the concentrations of over several hundreds ppb.

Out-of-Band Measurement of LED-based Solar Blind UV Filters

  • Cui, Muhan;Zhou, Yue;Chen, Xue;Yan, Feng;Zhang, Mingchao;Yang, Huaijiang
    • Journal of the Optical Society of Korea
    • /
    • 제18권3호
    • /
    • pp.244-250
    • /
    • 2014
  • Due to the difficulty in measuring very low out-of-band cutoff depths of solar blind UV filters, we propose a cutoff depth adjustable measurement system (CDAM) to test deep cutoff filters with a large dynamic range. The CDAM utilizing the substitution method is elaborately composed of several parts, including narrow-band LED light sources, standard reflective neutral attenuators with known attenuation coefficients, and a photomultiplier (PMT). This paper also presents an attenuator combination method ensuring that the PMT works within its linear response range. In addition, numerical simulation testifies to the method, and experiment shows that the CDAM system can achieve an extension of dynamic range from 0-6 OD to 0-10 OD, which is sufficient for the measurement of out-of-band cutoff depths of solar blind UV filters. Above all, the CDAM system, being easily implemented, of wide dynamic range, and highly precise, could be widely used in the measurement of filter cutoff depth.

구동장치의 동강성을 고려한 미사일 조종날개의 비선형 플러터 해석 (Nonlinear Flutter Analysis of Missile Fin considering Dynamic Stiffness of Actuator)

  • 신원호;배재성;이인;한재흥;신영석;이열화
    • 한국항공우주학회지
    • /
    • 제33권2호
    • /
    • pp.54-59
    • /
    • 2005
  • 구동기의 백래쉬와 동강성을 고려한 미사일 조종날개의 비선형 공탄성 해석이 수행되었다. 아음속 비정상 공기력 계산을 위해 DHM을 사용하였고 최소상태접근법을 사용하여 근사하였다. 비선형 플러터 해석을 위해 백래쉬는 유격으로 모델하고 기술 함수법을 사용하여 선형화하였다. 또한, 동강성은 주파수의 함수로 모터의 운동방정식으로부터 계산하였다. 선형 및 비선형 플러터 해석 결과들은 공력탄성학적 특성들이 백래쉬와 동강성에 중요한 영향을 받는다는 것을 보여준다. 비선형 플러터 해석에서 다양한 제한 주기 운동이 선형플러터 속도 이하에서 관측되었다. 또한 플러터 특성과 응답을 시간영역에서도 조사하였다.

비선형 영역에서의 재료감쇠비 측정을 위한 주파수-위상각법 (Frequency-Phase Method to Measure Material Damping in a Nonlinear Range)

  • 우규석;조성호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.533-540
    • /
    • 2001
  • Material damping is an important parameter to evaluate the site response by a dynamic loading. Currently the material damping of the subgrade is mainly determined by a resonant column testing. Typical methods to evaluate material damping include half-power bandwidth method and free-vibration decay method. In the large strain range, the half-power bandwidth method gives an erratic damping factor, because the method is based on the assumption of the linear behavior of a specimen. The free-vibration decay method has also limitations in that the damping factors vary with the range of cycles in calculation, and also in that the specific shear strain can not be designated for the free vibration. In this study, the frequency-phase method, which was developed to evaluate material damping of a beam simply supported, is introduced to evaluate the material damping by the resonant column testing. Also, the comparison among half-power method, free-vibration decay method and the frequency-phase method is provided for a remolded sand.

  • PDF

백라쉬를 갖는 속도제어구동 시스템의 문제점 (PROBLEMS OF A SPEED_CONTROLLED DRIVE SYSTEM WITH BACKLASH)

  • 이건용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.351-354
    • /
    • 1989
  • In a speed_controlled system with cascade control which shows an optimal performance in the linear case, limit cycles can occur due to backlash. The various effects observed can be explained with the aid of the describing function. With a first-order load torque observer these limit cycles can be avoided. Moreover the dynamic performance improves considerably and the range of application of cascade control is extended.

  • PDF

원자로의 직접 디지탈 제어를 위한 최적 제어계통의 설계 (Design of optimal control system of nuclear reactor for direct digital control)

  • 천희영;박귀태;이기상
    • 전기의세계
    • /
    • 제30권8호
    • /
    • pp.509-516
    • /
    • 1981
  • The optimal control theory is applied to the design of a digital control system for a nuclear reactor. A linear dynamic model obtained at 85% of rated power and a quadratic performance index are used. A minimal order observer used in cascade with the feedback controller is suggested as a state estimator. The total reactor power control is studied in the range of 80% to 100% of rated power, with the steady state and load-following control. The control algorithm considered is suitable for implementation in direct digital control.

  • PDF