• Title/Summary/Keyword: line regulation

Search Result 745, Processing Time 0.024 seconds

A Study for the Measurement Method of Electromagnetic Field Strength of Power Line Communications Modem (전력선통신모뎀의 전자계강도 측정방법 연구)

  • Jang Dong-Won
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.162-165
    • /
    • 2006
  • This paper describes a measurement method for electromagnetic field strength of power-line communications(PLC) modem. First it outlines the technology used in PLC modems, and the technical regulation being offered to the technology, from the point of view of its effect on electromagnetic compatibility (EMC). The radio spectrum needs protection from other interferers, and there is a regime in place to provide this protection. Difficulties in achieving compatibility between the requirements for radio protection and the requirements for operation of the PLC modem mean that there is no consensus as yet as to how PLC modem components can be made compliant with EMC requirements globally. It is concluded that there is a measurement method according to CISPR standards which satisfy requirements in domestic regulation.

  • PDF

A Study On The Improved Line Regulation For High Efficiency BoostDC-DCConverter (고효율 Boost DC-DC 변환기를 위한 Line Regulation 향상에 대한 연구)

  • Doo, Su-Yeon;Jeong, Seong-Yon;Chung, Jin-Il;Kwack, Kae-Dal
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.391-392
    • /
    • 2007
  • In recent, portable information and communication terminals such as a notebook computer, an electronic pocketbook, a hand personal computer(PC) have been regards as the leading role in the coming next generation portable multimedia terminals which have hi-directional wireless data communication capability and can receive information and communication services such as electronic mail, database searching, and electronic shopping at anytime and anyplace. Therefore, in this paper, the circuit is simulated by 0.35um memory process used Current Limit for Boost DC-DC converter. Supply voltage $2.5V{\sim}3.3V$, output voltage 5V, Clock Frequency 1MHz, output current 200mA and line regulation decreased 12.46%.

  • PDF

Switching Power Module for a Small-Sized Electric Power Source (소형 전원용 스위칭 파워 모듈)

  • 김병철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.5
    • /
    • pp.1068-1073
    • /
    • 2004
  • 5 V/500 mA transless type power module was designed by using a semiconductor switching technique for a small-sized electric power source. It used voltage drop type chopper method, and is composed of switching circuit, control circuit, voltage detect circuit, and constant voltage circuit. The switching power module which is designed in this study, showed load regulation of 0.2 V, line regulation of 0.1 V, output ripple of 85 mVp-p, switching frequency of 64.7 kHz, maximum power efficiency of 58 %, and satisfied its reliability and EMC test.

LDO Regulator with Improved Load Regulation Characteristics and Feedback Detection Structure (피드백 감지 회로 구조로 인한 향상된 Load Regulation 특성을 가진 LDO 레귤레이터)

  • Jung, Jun-Mo
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.1162-1166
    • /
    • 2020
  • In this paper Low Drop-Out (LDO) regulator that improved load regulation characteristics due to the feedback detection structure. The proposed feedback sensing circuit is added between the output of the LDO's internal error amplifier and the input of the pass transistor to improve the regulation of the delta value coming into the output. It has a voltage value with improved load regulation characteristics than existing LDO regulator. The proposed LDO structure was analyzed in Samsung 0.13um process using Cadence's Virtuoso, Spectre simulator.

Voltage Regulation Method Considering Load Variation Characteristics of High and Low Voltage Distribution Line in Distribution System (시간 불일치성을 고려한 배전계통 전압조정방법)

  • Kim, T.E.;Kim, C.S.;Kim, J.E.;Son, J.M.;Park, J.K.;Rho, D.S.;Kim, K.H.;Cho, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.115-117
    • /
    • 2002
  • In general, it is supposed that load characteristics of high and low voltage distribution line are always coincidence. But in practical distribution system, voltage variation characteristics of high and low voltage distribution line are not same. Then in this paper, we proposes a voltage regulation method considering load variation characteristics of high and low voltage distribution line in distribution system.

  • PDF

Analysis on Technical Standard for High Speed Power Line Communications (국내 고속전력선통신 도입을 위한 기술기준 분석)

  • Jang, Dong-Won;Cho, Pyung-Dong
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.3 no.2
    • /
    • pp.26-32
    • /
    • 2004
  • This paper represents analysis on domestic technical regulation of high speed power line communications(PLC). Also it gives comparison of regulations for several countries which include U.S., Europe, and Japan. Power line communications radiates harmful interference in below 30MHz. This may intervene other radio equipments. The technical regulation must protect interference and provide clean radio environment. Finally this paper gives the proposal which is drafted by field tests for introducing high speed PLC.

  • PDF

Effects of Regulation against Unlicensed Contents Sharing on the Contents Producers' Profit (불법복제에 대한 규제가 콘텐츠 제작자의 수익에 미치는 영향)

  • Koh, Byung-Wan;Song, Hee-Seok;Ryu, Young;Lee, Sang-Ho;Kim, Dong-Il
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.320-329
    • /
    • 2010
  • As software producers have tried to keep their profit against illegal piracy, contents producers also want to protect their contents from unlawful sharing among users. Some researchers uncovered that the regulation on the unlicensed contents is not the best policy to maximize their profit mainly due to network effect but this issue has been still controversial. In this paper, we develop a model to investigate the effect of regulation against unlicensed contents sharing on the profit of contents producers and present the optimal condition to maximize profit of contents producers under the regulation and non-regulation of unlicensed contents. As a result, we analyzed that the firm's payoff under the regulation on unlicensed contents is not always greater than the payoff under the non-regulation because of network externality. If the additional utility from off-line purchase of type P consumers (who enjoy the additional benefit of off-line purchase) is large enough, then the firm's payoff is maximized without regulation.

$\beta$-Alanine Induced Down-Regulation of the Taurine Transporter Activity in the Human Colon Carcinoma Cell Line (HT-29) (인체 소장상피세포주 모델(HT-29)에서 $\beta$-알라닌이 타우린수송체 활성에 미치는 영향)

  • 박태선;윤미영;정한나;이해미
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.2
    • /
    • pp.314-319
    • /
    • 2001
  • In the present study, effects of $\beta$-alanine, a known taurine antagonist for its structural similarity, on the adaptive regulation and kinetic behavior of the taurine transporter were investigated in the HT-29, human colon carcinoma cell line. Pretreatment of the cell with $\beta$-alanine(10mM) for varying periods from 3 to 30 hrs significantly reduced the taurine uptake compared to the value for control cells. This decrease in the taurine transporter activity was dependent on the incubation time with $\beta$-alanine, and the maximal down-regulation of the transporter activity was observed in cells pretreated with $\beta$-alanine for 24 hrs (25% of the control value, p<0.01). The taurine transporter appears to bind exclusively with $\beta$-alanine in the HT-29 cells since the same concentration of $\alpha$-alanine added in the culture medium for 24 hrs did not influence the taurine uptake. Kinetic analyses of the taurine transporter activity was performed in the HT-29 cell line with varying taurine concentration (5~60$\mu$M) in the uptake medium. Active taurine uptake was significantly lower in $\beta$-alanine pretreated cells compared to the value for control cells in the range of taurine concentration used in the experiment (p<0.001). The cells pretreated with $\beta$-alanine showed a 50% lower maximal velocity (Vmax, 1.7$\pm$2.0 nmole.mg $protein^{-1}$.$30min^{-1}$), and a 99% higher Michaelis constant (Km, 40.3$\pm$7.6$\mu$M) than the control values (3.3$\pm$1.9 nmole.mg $protein^{-1}$.$30min^{-1}$, and 20.3$\pm$2.1$\mu$M, respectively). These results on kinetic data suggest that $\beta$-alanine induced down-regulation of the taurine transporter activity was associated with decreases in both maximal velocity and affinity of the transporter.

  • PDF

Control of DSTATCOM for Line Voltage Regulation (선로 전압 조정을 위한 DSTATCOM 제어)

  • Jung, Soo-Young;Kim, Tae-Hyun;Moon, Seung-Il
    • Journal of IKEEE
    • /
    • v.5 no.2 s.9
    • /
    • pp.146-152
    • /
    • 2001
  • Two control techniques - PI and LQR(Linear Quadratic Regulator) - of DSTATCOM (Distribution Static Synchronous Compensator) for line voltage regulation in distribution system are presented. It is shown that the voltage waveform is improved if the proposed methods are applied in IEEE 13 radial distribution system using PSCAD/EMTDC package in case of single line-to-ground fault. The three cases - without control, with PI control and with LQR control - are compared. The LQR control is shown to be best in respect of response profile and control effort required among them.

  • PDF

Line Voltage Regulation of Urban Transit Systems Using Supercapacitors (슈퍼커패시터를 이용한 도시형 철도의 가선전압 안정화)

  • Son, Kyoung-Min;Choi, Jae-Ho;Kim, Hyung-Chul
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.481-487
    • /
    • 2009
  • This paper proposes a regulation method of DC line voltage for urban transit system fluctuated during the acceleration or deceleration by using supercapacitor. Supercapacitor is modelled electrically under the assumption of three different time constants of RC circuits with variable capacitances depending on the voltage. And its parameters are determined by the experimental measurements. The energy storage system using supercapacitors is installed based on this model, and the proposed model is tested through the simulations and experiments, and the controller for charging and discharging is designed. Finally, it is tested at Kyoungsan test site for the urban light rail road system and the energy saving effect is evaluated economically.