• Title/Summary/Keyword: line impedance measurement

Search Result 137, Processing Time 0.022 seconds

Development of Signal Coupler for Power Line Communication over Medium Voltage Distribution Line (고압 배전선로 전력선 통신 신호결합장치 개발)

  • Lee Jae-Jo;Park Young-Jin;Oh Hui-Myoung;Kim Kwan-Ho;Lee Dae-Young
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.6
    • /
    • pp.409-416
    • /
    • 2005
  • For broadband high-data-rate power line communication with the allocated frequency bandwidth from 2 to 30 MHz on medium voltage (MV) distribution power lines, a signal coupling unit is developed. The coupling unit is composed of a coupling capacitor for coupling communication signal, a drain coil, and an impedance matching part. The coupling capacitor made of ceramic capacitor is designed for transmission property of better than 1 dB in the frequency range. The drain coil is used for preventing low frequency high voltage from junction of medium voltage power line in case that a coupling capacitor is not working properly any more. Also, using ferrite core, a novel broadband impedance matching transformer is developed. A complete coupling unit with a coupling capacitor, a drain coil, and a matching transformer is housed by polymer for good isolation and distinguishing from high voltage electric facilities. Each is fabricated and its frequency behavior is tested. Finally, complete signal couplers are equipped in a MV PLC test bed and their performance are measured. The measurement shows that the coupling capacitor works excellently.

Analysis of Medium Voltage Power-Line Channel Characteristics Considering the Skin Effect (표피효과를 고려한 중전압 전력선 채널특성 분석)

  • 김선효;이원태;이영철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.5
    • /
    • pp.731-738
    • /
    • 2002
  • In this paper, we analyzed a medium voltage power line characteristics considering the skin effect for high speed data transmission. Medium power-line characteristics impedance was obtained by the S-parameter method which is used in high frequency band. Power line channel characteristics was measured using it designed coupler, it is a wide band coupler between medium powe-line and measurement system. Attenuation characteristics along the frequency was decreased linearly when skin effect was considered but attenuation characteristics along the frequency was decreased linearly when skin effect was not considered. Impedance was showed lower and lower in proportional to frequency, and variation was decreased in proportional to frequency.

Electric Fuel Sender Apparatus for the Vehicles Using CPW Transmission Line (CPW 전송선을 이용한 전자식 자동차용 연료 센더 장치)

  • Son Tae-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.4 s.107
    • /
    • pp.380-386
    • /
    • 2006
  • Electric fuel sender fur the vehicle fuel gauge system was designed and fabricated based on the CPW(Co-Planer Waveguide) transmission line theory. It is applied on this system that characteristic impedance of RF transmission line can be varied by the surrounded material of the line. By the characteristic impedance owing the level of gasoline or diesel fuel in vehicle fuel tank, CPW line has corresponding reflected signal as much as changed impedance. Detected signal is amplified, and delivered to fuel indicator into cluster unit on dash board. Conventional floating mechanical buoy level gauge has several defects as low reliability and high break down rate by mechanical operation, and has not good linearity for the fuel level difference. CPW line with electric circuits are constructed on 1.6 mm thickness epoxy substrate, and measurement shows that this system has more accurate level and better linearity than conventional mechanical system. New electric fuel sender which has good productivity with long lifetime and low-in-cost by the SMT chip assembling could be replaced this system with conventional floating buoy system.

A Study on Operation Zone of Adaptive Distance Relay on Transmission Line Connected UPFC Between Kangjin and Jangheung (UPFC가 연계 된 강진-장흥 송전선로 보호용 거리계전기의 동작특성에 관한 연구)

  • Lee, Seung-Hyuk;Jung, Chang-Ho;Kim, Jin-O;Jung, Hyun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.305-307
    • /
    • 2003
  • This paper presents an apparent impedance calculation procedure for distance relaying of transmission line involving FACTS (Flexible AC Transmission System) devices, particularly the UPFC (Unified Power Flow Controller), between Kangjin and Jangheung in Korea. With the changes of UPFC's parameters, the measurement and protective range (trip boundaries) of the adaptive distance relay can also be changed. So, it is the most important part in the field of system protection to analyze the operating characteristic of relaying system. The presence of UPFC significantly affects the trip boundaries which are also adversely affected by fault resistance combined with remote end infeed. This paper presents the apparent impedance calculations and the distance relay setting characteristics for faults involving the UPFC in the KEPCO system.

  • PDF

An Application of the On Line Partial Discharge Measurement Method in Transformer (온라인 변압기 부분방전 측정기법 적용)

  • Kweon, Dong-Jin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.394-400
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

On Line Partial Discharge Measurement Method for Transformer (온라인 변압기 부분방전 측정기법)

  • Kweon, Dong-Jin;Choi, In-Hyuk;Song, Il-Keun;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.38-42
    • /
    • 2001
  • This paper describes an application of the on line partial discharge measurement method in operating transformer. In the operating transformer, the partial discharge signal may be superimposed by radio intereference voltage(RIV) and pulse shaped noise signals generated by external corona. The partial discharge quantity showed about 3,800pC due to very high sinusoidal interferences at the measuring impedance terminal of the transformer bushing tap. In order to reject these noises, this paper applied RIV filter, band-pass filters and noise gating method. The resulting measuring sensitivity was improved from 3,800pC to 160pC.

  • PDF

Analysis and Experiment of Micro-strip Line Lumped Elements for SAW Duplexers (탄성표면파 듀플렉서용 마이크로 스트립라인 집중소자 해석 및 실험)

  • 이승희;노용래
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.1
    • /
    • pp.85-92
    • /
    • 2002
  • In this study, we analyzed and experimented micro-strip line inductors and capacitors for a SAW duplexer, an important devise for mobile communication. For SAW duplexers, micro-strip line lumped elements must have small impedance values, below several tens of nH or several tens of pF, and a small area pattern. In this study, we performed theoretical analysis of flat line type, meander line type, and spiral line type inductors and interdigital capacitors on a LiTaO$_3$ Piezo-crystal. We proposed a measurement method to evaluate small values of lumped elements accurately with network analyzer. In experiments, we confirmed validity of the theoretical analysis method through fabrication and characterization of micro-strip line lumped elements. The analysis method in this paper can be applied to SAW duplexers well as other microwave devices.

A Study on Dielectric Properties of Printed Circuit Board(PCB) Materials with Variation of Frequency and Temperature using Coaxial Air Line Probe (동축선로 프로브를 이용한 프린트 배선 회로용 기판 재료의 주파수 및 온도 변화에 따른 유전특성 연구)

  • 박종성;김종헌
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.187-190
    • /
    • 1998
  • In this paper a probe for the' measurement of dielectric properties of dielectric sheet materials is designed and implemented as a coaxial air line type. Using the broadband impedance method with this measurement probe the dielectric constant and loss tangent of the glass-epoxy and teflon are determined in the frequency range of 0.1 - l.O[GHz] with the temperature variation from $25[^{\circ}C]$ up to $65[^{\circ}C]$. A measured relative dielectric constant of the glass-epoxy is 4.42 and a loss tangents is 0.019 relatively, and the relative dielectric constants of teflon is 2.17 and a loss tangents is 0.002 relatively

  • PDF

The Eddy Current Method to Measure the Transformation Ratio in Metals (와전류 시험에 의한 금속의 변태율 측정에 관한 연구)

  • Wee, Sang-Bong;Han, Min-Koo;Paek, KI-Nam
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.5
    • /
    • pp.348-354
    • /
    • 1989
  • The metallurgical transformation ratios of metals have been evaluated by the eddy current method. Eddy current probes have been designed and applied to various standard samples. The equivalent impedance estimated from the eddy current measurement is closely related to the variation of transformation ratios in metals. It has been found that the variation of the impedance is relatively large in the samples where the transformation ratios of the samples are small. Both reactance and resistance increase when the transformation ratio is large. Sensitivities of eddy current test is increased with increasing frequencies and by inserting ferrite core the solenoid eddy probe. Our results have shown the implementation of eddy current measurement to the one-line nondestructive testing of metals.

  • PDF

Fault Location and Classification of Combined Transmission System: Economical and Accurate Statistic Programming Framework

  • Tavalaei, Jalal;Habibuddin, Mohd Hafiz;Khairuddin, Azhar;Mohd Zin, Abdullah Asuhaimi
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2106-2117
    • /
    • 2017
  • An effective statistical feature extraction approach of data sampling of fault in the combined transmission system is presented in this paper. The proposed algorithm leads to high accuracy at minimum cost to predict fault location and fault type classification. This algorithm requires impedance measurement data from one end of the transmission line. Modal decomposition is used to extract positive sequence impedance. Then, the fault signal is decomposed by using discrete wavelet transform. Statistical sampling is used to extract appropriate fault features as benchmark of decomposed signal to train classifier. Support Vector Machine (SVM) is used to illustrate the performance of statistical sampling performance. The overall time of sampling is not exceeding 1 1/4 cycles, taking into account the interval time. The proposed method takes two steps of sampling. The first step takes 3/4 cycle of during-fault and the second step takes 1/4 cycle of post fault impedance. The interval time between the two steps is assumed to be 1/4 cycle. Extensive studies using MATLAB software show accurate fault location estimation and fault type classification of the proposed method. The classifier result is presented and compared with well-established travelling wave methods and the performance of the algorithms are analyzed and discussed.