• Title/Summary/Keyword: line center

Search Result 4,344, Processing Time 0.038 seconds

A Study on Cryogenic Line Chill Down Characteristics of LNG (극저온 LNG 배관냉각 특성에 대한 연구)

  • BYEONGCHANG, BYEON;KYOUNG JOONG, KIM;SANGKWON, JEONG;MO SE, KIM;SANGYOON, LEE;KEUN TAE, LEE;DONGMIN, KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.6
    • /
    • pp.808-818
    • /
    • 2022
  • In this research paper, we investigated the cryogenic line chill down characteristics of liquefied natural gas (LNG). A numerical analysis model was established and verified so that it can calculate the precise cooling characteristics of cryogenic fluid for the stable and safe utilization especially such as LNG and liquid hydrogen. The numerical modeling was programmed by C++ as an one-dimensional homogeneous model. The thermohydraulic cooling process was simulated using mass, momentum, energy conservation equations and appropriate heat transfer correlations. In this process, the relevant heat transfer correlations for nuclear boiling, transition boiling, film boiling, and single-phase heat transfer that can predict the experimental results were implemented. To verify the numerical modeling, several cryogenic line chill down experiments using LNG were conducted at the Korea Institute of Machinery & Materials (KIMM) LNG and Cryogenic Technology Center.

A Performance Investigation and Comparison of Line Start-up Permanent Magnet Synchronous Motor with Super Premium Efficiency

  • Feng, Xueqing;Bao, Yaxin;Liu, Lijun;Huang, Lizhong;Zhang, Yingming
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.30-37
    • /
    • 2012
  • This paper presents the performance investigation and design technology of a Line Start-up Permanent Magnet Synchronous Motor (LSPMSM) with super premium efficiency, including a design consideration and evaluation for motor start-up, key performance, and advanced finite element analysis FEA) for the design, improvement and verification, prototype build and test, design and test data comparison with a $Premium^{(R)}$ Efficient Induction Motor (PEIM). To assess the design technology, the LSPMSM prototype was built amended from a PEIM with the same frame, stator punching and rated output. Based on the prototype test, two novel design improvements and analyses have been done to eliminate noise and vibration. Additionally, the comparisons with the PEIM on the power factor, efficiency, frame size and active material consumption indicated that a significant performance improvement and active material cost reduction can be achieved by the LSPMSM.

The Development of Fault and Lightning Stroke Section Location System for Overhead Transmission Line (가공지선 전류 검출 방식의 송전선 사고 및 낙뢰 구간 검출 시스템 개발)

  • Lee C.Y.;Kim J.N.;Oh D.J.;Ha C.W.;Kim D.W.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.584-586
    • /
    • 2004
  • This paper deals with the development of on-line fault and lightning stroke section locating system for branched overhead transmission line. The section locating algorithm of this system i3 by analyzing the distribution pattern of current flowing through the overhead ground wire. It composes of three parts; current sensors, local remote terminal unit(RTU) and analysis program at surveillance tenter. Double Rogowski coil sensor having integrating amplifier was designed as current sensor. In order for current pattern analysis, the transmitted waves from each sensor wert synchronized by GPS tim c clock in RTU. While, lightning stroke location are judged only by polarity information of lightning currents. This design has a benefit in simplicity of signal processing unit of RTU.

  • PDF

Examination with Transmission Line Distance Relay Setting Rule Considering Error (오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰)

  • Cho, Seong-Jin;Choi, Myeong-Song;Hyun, Seung-Ho;Kim, Joung-Wook;Lee, Joo-Wang;Cho, Bum-Sub;Yoo, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

Development of an RT-PCR assay and its positive clone for plant quarantine inspection of American plum line pattern virus in Korea

  • Da-Som Lee;Junghwa Lee;Seong-Jin Lee;Seungmo Lim;Jaeyong Chun
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.4
    • /
    • pp.821-831
    • /
    • 2022
  • American plum line pattern virus (APLPV), a member of the genus Ilarvirus in the family Bromoviridae, is one of the plant quarantine pathogens in Korea. In this study, 15 candidate primer sets were designed and examined to develop a reverse transcription polymerase chain reaction (RT-PCR) assay for plant quarantine inspection of APLPV. Using APLPV-infected and healthy samples, the primer sets were assessed for APLPV detection. To confirm the occurrence of nonspecific reactions, six ilarviruses (Apple mosaic virus, Asparagus virus 2, Blueberry shock virus, Prune dwarf virus, Prunus necrotic ringspot virus, and Tobacco streak virus) and 10 target plants (Prunus mume, P. yedoensis, P. persica, P. armeniaca, P. dulcis, P. tomentosa, P. avium, P. glandulosa, P. salicina, and P. cerasifera) were examined. Finally, two primer sets were selected. These primer sets could generate the expected amplicons even with at least 1 ng of the total RNA template in concentration-dependent amplifications. In addition, a positive clone was developed for use as a positive control in the abovementioned RT-PCR assay.

Phosphoproteomic Analysis of AML14.3D10 Cell Line as a Model System of Eosinophilia

  • Ryu, Su-In;Kim, Won-Kon;Cho, Hyun-Ju;Lee, Phil-Young;Jung, Hye-Yun;Yoon, Tae-Sung;Moon, Jeong-Hee;Kang, Sung-Hyun;Poo, Ha-Ryoung;Bae, Kwang-Hee;Lee, Sang-Chul
    • BMB Reports
    • /
    • v.40 no.5
    • /
    • pp.765-772
    • /
    • 2007
  • Eosinophils act as effectors in the inflammatory reactions of allergic diseases including atopic dermatitis. Atopic dermatitis patients and others with allergic disorders suffer from eosinophilia, an accumulation of eosinophils due to increased survival or decreased apoptosis of eosinophils. In this study, a differential phosphoproteome analysis of AML14.3D10 eosinophil cell line after treatment with IL-5 or dexamethasone was conducted in an effort to identify the phosphoproteins involved in the proliferation or apoptosis of eosinophils. Proteins were separated by 2-DE and alterations in phosphoproteins were then detected by Pro-Q Diamond staining. The significant quantitative changes were shown in nineteen phosphoproteins including retinoblastoma binding protein 7, MTHSP75, and lymphocyte cytosolic protein 1. In addition, seven phosphoproteins including galactokinase I, and proapolipoprotein, were appeared after treatment with IL-5 or dexamethasone. Especially, the phospho-APOE protein was down-regulated in IL-5 treated AML14.3D10, while the more heavily phosphorylated APOE form was induced after dexamethasone treatment. These phosphoproteome data for the AML14.3D10 cell line may provide clues to understand the mechanism of eosinophilia as well as allergic disorders including atopic dermatitis.

The study on slipping down phenomenon of 345kv XLPE cable in inclinatior (경사지에서의 345kV XLPE $1C{\times}2000mm^2$ 케이블 코아 활락 현상 연구)

  • Baek, J.H.;Nam, S.H.;Lee, S.K.;Heo, H.D.;Kim, D.W.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1782-1784
    • /
    • 2002
  • In this paper, the coefficient of friction betwee and sheath in 345kv XLPE cable was measured the simulated inclinated condition of You-Youngdeungpo transmission line. The phenomena of slipping down the simu inclination was investigated theoretically usin measured data and was analyzed from experim result. The measured and analyzed result were conside be as a reference data for real installation of XLPE Youngseo-Youngdeungpo transmission line.

  • PDF

Analysis on Installation Condition According to Dynamic Characteristics for Overhead Catenary System (전차선로 동적특성에 따른 설치상태 분석)

  • Park, Young;Lee, Kiwon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1605-1609
    • /
    • 2016
  • The measurement of current collection performance between pantograph and contact wire of overhead catenary system is intended to prove the safety of operation and the quality of the current collection system. The results of interaction performance of current collection system are required for approving with commercial operation on railway lines. The methods of interaction performance of current collection system are defined on interactional standards such as IEC 62486 and EN 50317. In this paper, the interaction performance is evaluated by the percentage of arcing on Honam high-speed line and the results are used for adjustment of the overhead catenary line structure. The experimental results in Honam high-speed line confirm that the duration of an arc lasting longer 25 ms between pantograph and contact wire was depended on the conditions of overhead contact line after installation.

The Novel Concepts for Reliability Technology

  • Ryu, DongSu
    • Corrosion Science and Technology
    • /
    • v.4 no.5
    • /
    • pp.201-206
    • /
    • 2005
  • Starting with the meaning of the word quality, diverse concepts connoted by the term are examined. Instead of a bathtub curve, the desirable shape of a failure rate covering the entire life of a good product, which might be called hockey-stick line, is introduced. From the hockey-stick line and the definition of reliability, two measurements are extracted. The terms r-reliability (failure rate) and durability (product life) are explained. The conceptual analysis of failure mechanics explains that reliability technology pertains to design area. The desirable shape of hazard rate curve of electronic items, hockey-stick line, clarifies that Mean-Time-to-failure (MTTF) as the inverse of failure rate can be regarded a nominal life. And Bx life, different from MTTF, is explained. Reliability relationships between components and set products are explained. Reshaped definitions of r-reliability and durability are recommended. The procedure to improve reliability and the reasons for failing to identify failure mode are clarified in order to search right solutions. And generalized Life-Stress failure model is recommended for the calculation of acceleration factor.