Browse > Article
http://dx.doi.org/10.5370/KIEE.2016.65.9.1605

Analysis on Installation Condition According to Dynamic Characteristics for Overhead Catenary System  

Park, Young (Dept. of High-Speed Railroad Research Center, Korea Railroad Research Institute)
Lee, Kiwon (Dept. of High-Speed Railroad Research Center, Korea Railroad Research Institute)
Publication Information
The Transactions of The Korean Institute of Electrical Engineers / v.65, no.9, 2016 , pp. 1605-1609 More about this Journal
Abstract
The measurement of current collection performance between pantograph and contact wire of overhead catenary system is intended to prove the safety of operation and the quality of the current collection system. The results of interaction performance of current collection system are required for approving with commercial operation on railway lines. The methods of interaction performance of current collection system are defined on interactional standards such as IEC 62486 and EN 50317. In this paper, the interaction performance is evaluated by the percentage of arcing on Honam high-speed line and the results are used for adjustment of the overhead catenary line structure. The experimental results in Honam high-speed line confirm that the duration of an arc lasting longer 25 ms between pantograph and contact wire was depended on the conditions of overhead contact line after installation.
Keywords
Overhead catenary system; duration of an arc; Current collection system.;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 C. M. Park, Y. Park, K. W. Lee, S. Y. Kwon, Y. H. Cho, J. M. Kim, "Evaluation schedule for Current Collection Performance of 400km/h Catenary System in Honam high- speed line", The Transactions of the Korean Institute of Electrical Engineers, pp. 16-18, 2014. 7
2 Y. Park, Y. H. Cho, H. C. Kim, K. W. Lee, C. B. Park, I. C. Kim, "Analysis of Performance Assessment for Current Collection Systems in Electric Railway", Korean Society for Railway, pp. 3402-3405, 2009, 11
3 Y. Park, S. Y. Kwon, K. W. Lee, Y. H. Cho, S. Y. Park, C. W. Lim, I. G. Yoon, "Testing Technology for Track-side measurement of New Catenary System up to 400Km/h", The Transactions of the Korean Institute of Electrical Engineers, pp. 10-12, 2013. 7
4 EN 50317:2001, "The European Standard, Railway applications-Current collection systems- Requirements for and validation of measurements of the dynamic interaction between pantograph and overhead contact line", 2001.
5 Y. Park, K. W. Lee, C. M. Park, S. Y. Kwon, "Implementation of Optimization of the Uplift Amount Measurement System of Overhead Contact Line", The Transactions of the Korean Institute of Electrical Engineers Vol. 62, No. 6, pp. 886-890, 2013   DOI
6 Y. Park, C. M. Park, K. W. Lee, S. Y. Kwon, "Implement of Dynamic Performance Measurement System Between Pantograph and Contact wire in Tunnel", The Transactions of the Korean Institute of Electrical Engineers Vol. 61, No. 11, pp. 1732-1736, 2012.11   DOI
7 Y. Park, Y. H. Cho, H. S. Jung, K. W. Lee, H. C. Kim, S. Y. Kwon, H. J. Park, W. h. Kim, "Implementation of Optical-based Measuring Instrument for Contact Wire Geometry in Electric Railway", Journal of the Institute of Electrical and Electronic Material Engineers, Vol. 21, No.9, pp. 868-871, 2008.10
8 K. W. Lee, H. S. Jung, Y. Park, H. R. Cho, S. S. Lee, "Development of Section Insulator with Improved Wear Characteristics", The Transactions of the Korean Institute of Electrical Engineers Vol. 62, No. 11, pp. 1633-1639, 2013.11   DOI
9 K. W. Lee, Y. Park, S. Y. Kwon, Y. H. Cho, H. S. Jeong, "Development of a Steady Arm for the Maximum Speed of 400 km/h", The Transactions of the Korean Institute of Electrical Engineers Vol. 63, No. 12, pp. 1742-1746, 2014.12   DOI
10 EN 50317 : 2001, "The European Standard, [3] EN 50317 : 2001, "The European Standard, Railway applications-Current collection systems - Requirements for and validation of measurements of the dynamic interaction between pantograph and overhead contact line", 2002.
11 Y. Park, Y. H. Cho, S. Y. Kwon, K. W. Lee, W. H. You, "Development of Are Detector Assessment System by Loss of Contact Between Pantograph and Contact Wire in Electric Railway", The Transactions of the Korean Institute of Electrical Engineers Vol. 60, No. 11, pp. 2171-2175, 2011.11   DOI
12 Y. Park, K. W. Lee, S. Y. Kwon, C. M. Park, J. K. Kim, W. S. Choi, "Analysis of Percentage of Arcing between Pantograph and Overhead Contact Line as a Function of Duration of Arc", The Transactions of the Korean Institute of Electrical Engineers Vol. 63, No. 6 pp. 855-859, 2014.6   DOI