• Title/Summary/Keyword: limit of quantification

Search Result 464, Processing Time 0.022 seconds

Determination of Ceftiofur in Bovine Serum by liquid Chromatography-Electrospray Mass Spectrometry (액체크로마토그래프/질량분석기를 이용한 소의 혈청 중 Ceftiofur의 분석)

  • Lim, Jong-hwan;Jang, Beon-su;Park, Byung-kwon;Yun, Hyo-in
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.3
    • /
    • pp.429-433
    • /
    • 2003
  • This study was aimed to develop a more rapid, simple and sensitive method to determine ceftiofur in bovine serum using LC/MS with electrospray interface. Separation was achieved on the Nova-Pak $C_{18}$ reverse phase column. The mobile phase consisted of 0.1% acetic add in water (A) and acetonitrile (B) and gradiently flowed at the rate of 0.4 mL/min. As a result of analysis of blank muscle samples, matrix interference was not shown. Limit of detection and limit of quantitaion was 5 ng/g and 20 ng/g, respectively. The values of precision and recovery satisfied the guideline of NVRQS. The precision and recovery developed in this method are suitable and sensitive to determine the concentration of ceftiofur in the bovine serum. These results could be applied for the confirmation and quantification in the biofluid.

Validation, Measurement Uncertainty, and Determination of Bixin and Norbixin in Processed Foods of Animal Resources Distributed in Korea

  • Ga-Yeong Lee;Choong-In Yun;Juhee Cho;Young-Jun Kim
    • Food Science of Animal Resources
    • /
    • v.43 no.6
    • /
    • pp.949-960
    • /
    • 2023
  • This research aimed to validate a high-performance liquid chromatography method for the quantitative determination of bixin and norbixin in various foods. The Diode Array Detector (495 nm) technique was used. Method was validated for specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy, and the measurement uncertainty was assessed. The calibration curve showed excellent linearity (r2≥0.9999) over the tested concentration range of 0.2-25 mg/L. The LOD and LOQ were 0.03-0.11 and 0.02-0.05 mg/L for bixin and norbixin, respectively. The intra-and inter-day accuracies and precisions were 88.0±1.3-97.0±0.5% and 0.2%-2.6% relative SD (RSD) for bixin and 88.2±0.8-105.8±0.8% and 0.3%-2.7% RSD for norbixin, respectively. Inter-laboratory validation for accuracy and precision was conducted in three laboratories, and these results all met the AOAC guidelines. In addition, the relative expanded uncertainty (<22%) satisfied the CODEX recommendation. Furthermore, products distributed in Korea were monitored for annatto extracts using the proposed method to demonstrate its application. The developed analytical method is reliable for quantifying bixin and norbixin in various foods.

Optimization of Ascorbic Acid Extraction from Rugosa Rose (Rosa rugosa Thunb.) Fruit Using Response Surface Methodology and Validation of the Analytical Method

  • UM, Min;KIM, Ji-Woo;LEE, Jae-Won
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.364-375
    • /
    • 2020
  • In this study, ultrasound-assisted extraction was performed to extract ascorbic acid from rugosa rose (Rosa rugosa Thunb.) fruit. The optimal conditions were investigated by response surface methodology, using two variable including reaction time (16-44 min) and temperature (16-44℃). The ascorbic acid extraction was sensitive to the reaction time rather than the reaction temperature, and the optimal conditions for ascorbic acid extraction were 25℃ and 30 min. Ascorbic acid and gallic acid in the rugosa rose fruit extract were completely separated by HPLC, with a resolution factor of over 1.5 between the two. The correlation coefficient of the ascorbic acid was 0.999 in a linearity test for 50-150 ㎍/mL concentration of extract. The limit of detection and limit of quantification values were 0.16 ㎍/mL and 29.89 ㎍/mL, respectively. The relative standard deviations (RSD) for repeatability and reproducibility were determined, and each RSD showed good precision at less than 5% (N=6).

Development of a Validated Determination of Methylsulfonylmethane in Dietary Supplement by Gas Chromatography (기체크로마토그래피를 이용한 식이보충제에서 메틸설포닐메탄의 검증된 분석법 개발)

  • Park, Sang-Wook;Lee, Wonjae
    • KSBB Journal
    • /
    • v.30 no.4
    • /
    • pp.141-147
    • /
    • 2015
  • The convenient determination of methylsulfonylmethane (MSM) for a commercially available dietary supplement was developed using gas chromatography (GC)-flame ionization detector (FID). Chromatography was performed on a capillary column ($0.32mm\;I.D{\times}30m$, $0.25{\mu}m$) coated with dimethylpolysiloxane using diethylene glycol methyl ether as an internal standard. The performance characteristics of GC were evaluated in terms of selectivity, linearity, precision, accuracy, recovery, limit of detection (LOD) and limit of quantification (LOQ). The calibration curve was highly linear (the coefficient of determination: 0.9979) within the concentration range of $10.0{\sim}800.0{\mu}g/mL$ for MSM. The recoveries for three fortified concentrations were 96.7~97.1%, 96.6~97.3% and 96.8~97.2%, respectively. The LOD and LOQ of the method were $0.29{\mu}g/mL$ and $0.97{\mu}g/mL$, respectively. All obtained results were acceptable according to the guidelines of the Association of Official Analytical Chemists for dietary supplements. Thus, the validated analytical method using the GC-FID system is suitable for the determination of MSM in dietary supplement formulations for quality control.

Validation of an analytical method for cyanide determination in blood, urine, lung, and skin tissues of rats using gas chromatography mass spectrometry (GC-MS)

  • Shin, Min-Chul;Kwon, Young Sang;Kim, Jong-Hwan;Hwang, Kyunghwa;Seo, Jong-Su
    • Analytical Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.88-95
    • /
    • 2019
  • This study was conducted to establish the analytical method for the determination of cyanide in blood, urine, lung and skin tissues in rats. In order to detect or quantify the sodium cyanide in above biological matrixes, it was derivatized to Pentafluorobenzyl cyanide (PFB-CN) using pentafluorobenzyl bromide (PFB-Br) and then reaction substance was analyzed using gas chromatography mass spectrometer (GC/MS)-SIM (selected ion monitoring) mode. The analytical method for cyanide determination was validated with respect to parameters such as selectivity, system suitability, linearity, accuracy and precision. No interference peak was observed for the determination of cyanide in blank samples, zero samples and lower limit of quantification (LLOQ) samples. The lowest limit detection (LOD) for cyanide was $10{\mu}M$. The linear dynamic range was from 10 to $200{\mu}M$ for cyanide with correlation coefficients higher than 0.99. For quality control samples at four different concentrations including LLOQ that were analyzed in quintuplicate, on six separate occasions, the accuracy and precision range from -14.1 % to 14.5% and 2.7 % to 18.3 %, respectively. The GC/MS-based method of analysis established in this study could be applied to the toxicokinetic study of cyanide on biological matrix substrates such as blood, urine, lung and skin tissues.

Establishment of analytical methods for allergenic compounds in mouthwashes and sanitary napkins by ultra-high-performance liquid chromatography with tandem mass spectrometry

  • Hee-Jung Sim;Hee-Jin Jeong;Yeong-In Lee;Yu-Jin Cho;Seung-Hoon Baek;Jong-Hwan Kim
    • Analytical Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.89-98
    • /
    • 2023
  • Analytical methods for detecting atranol, chloroatranol, evernic acid, (+)-usnic acid, and atranorin in sanitary napkins and mouthwashes were developed using ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). UHPLC-MS/MS conditions were optimized for rapid, sensitive, and simultaneous analysis of the five allergenic compounds. The methods were validated by assessing their specificity, matrix effects, limit of detection (LOD), limit of quantification (LOQ), linearity, accuracy, and precision. Good linearity was achieved with a determination coefficient of ≥0.99. The LOD and LOQ were 2.1-9.8 and 6.4-29.6 ng/g for sanitary napkins and 0.29-0.48 and 0.87-1.45 ng/mL for mouthwashes, respectively. The accuracy and precision were within an acceptable range according to the criteria reported in the European SANTE/11813/2017 guidelines (70-120 % recovery, <20 % relative standard deviation). Therefore, these methods can be used to analyze atranol, chloroatranol, evernic acid, (+)-usnic acid, and atranorin in sanitary napkins and mouthwashes.

Copy Paper as a Platform for Low-cost Sensitive Glucose Sensing

  • Ye Lin Kim;Young-Mog Kim;Junghwan Oh;Joong Ho Shin
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.1
    • /
    • pp.16-21
    • /
    • 2023
  • This study reports the potential of using commercial copy papers as substrates for simple sensitive glucose detection. Typical paper-based devices use filter papers as porous substrates that can contain reagents; however, this is the first study to report the use of copy papers for the purpose of enhancing enzymatic colorimetric detection. Glucose detection using glucose oxidase, horseradish peroxidase and potassium iodide was performed on a copy paper, cellulose-based filter paper, and polyethylene film. The results indicated that the copy paper exhibited a stronger coloration than the other substrates. Reagents required for detection were dried on the copy paper, and a 3D-printed holder was designed to provide an environment for consistent imaging, making it a convenient cost-effective option for point-of-care testing using a mobile phone camera. The simple paper-based glucose sensor exhibited a linear range of 0.1-20 mM, limit of quantification of 0.477 mM, and limit of detection of 0.143 mM.

Evaluation of Chemical Analysis Method and Determination of Polycyclic Aromatic Hydrocarbons Content from Seafood and Dairy Products

  • Lee, So-Young;Lee, Jee-Yeon;Shin, Han-Seung
    • Toxicological Research
    • /
    • v.31 no.3
    • /
    • pp.265-271
    • /
    • 2015
  • This study was carried out to investigate contents of 8 polycyclic aromatic hydrocarbons (PAHs) from frequently consumed seafood and dairy products and to evaluate their chemical analysis methods. Samples were collected from markets of 9 cities in Korea chosen as the population reference and evaluated. The methodology involved saponification, extraction with n-hexane, clean-up on Sep-Pak silica cartridges and gas chromatograph-mass spectrometry analysis. Validation proceeded on 2 matrices. Recoveries for 8 PAHs ranged from 86.87 to 103.57%. The limit of detection (LOD) 8 PAHs was $0.04{\sim}0.20{\mu}g/kg$, and limit of quantification (LOQ) of 8 PAHs was $0.12{\sim}0.60{\mu}g/kg$. The mean concentration of benzo[a]pyrene (BaP) was $0.34{\mu}g/kg$ from seafood and $0.34{\mu}g/kg$ from dairy products. The total PAHs concentration was $1.06{\mu}g/kg$ in seafood and $1.52{\mu}g/kg$ in dairy products.

A Fast Determination of Globotriaosylsphingosine in Plasma for Screening Fabry Disease Using UPLC-ESI-MS/MS

  • Yoon, Hye-Ran
    • Mass Spectrometry Letters
    • /
    • v.6 no.4
    • /
    • pp.116-119
    • /
    • 2015
  • Globotriaosylsphingosine (lyso-Gb3) is considered as one of the biological marker for Fabry disease. To date, a reliable biomarker that reflects disease severity and progression has not been discovered to guide the management of Fabry disease. A new method included a simple protein precipitation with acetonitrile in 100 μL of plasma following analyte separation on an Phenomenex Kintex- C18 column using a gradient elution (0.1% formic acid in 5-90% acetonitrile). Total run time was within 12 min including sample preparation and MS/MS analysis. The limit of detection and limit of quantitation were 1 ng/mL and 2 ng/mL, respectively. The calibration curve was linear over the concentration range of 2.0-200.0 ng/mL (r2 = 0.9999). Inter-day accuracy and precision at 7 level were 93.4-100.7% with RSD of 0.55-5.97%. Absolute recovery was 97.6-98.6%. The method was applied to human and mice plasma, proved the suitability for quantification of lyso-Gb3 for screening, diagnosis and therapeutic monitoring of Fabry disease patients.

Feasibility of monitoring of fluoroquinolones residual through feather analysis in broilers (육계에서 깃털을 이용한 플루오르퀴놀론계 잔류 모니터링 가능성 조사)

  • Kim, Jae-Ho;Kim, Mi-Hee;Ahn, Gil-Ho
    • Korean Journal of Veterinary Service
    • /
    • v.43 no.3
    • /
    • pp.189-196
    • /
    • 2020
  • This study was conducted to analyze feasibility of monitoring of fluoroquinolnes residual through feather analysis in broilers. The calibration curve showed good linearity (r2≥0.99) within the concentration range of 1~100 ㎍/kg. The limit of detection (LOD) and limit of quantification (LOQ) were validated at ≤0.66 and ≤1.99 ㎍/kg in broiler feather, respectively. The recoveries in feather samples ranged from 94.6 to 114.4% (5.1-15.8% RSD) at the 5 to 20 ㎍/kg spiking levels. The proposed new analytical method proved to be suitable and effective for fluoroquinolnes determination. We also monitored fluoroquinolones residue in 36 samples (broiler that were slaughtered in Gyonggi-do) using this method. Among tested feather samples, enrofloxacin and ciprofloxacin were detected in all samples. In muscle samples, enrofloxacin was detected in 20 (55.6%) samples and ciprofloxacin was not detected.