• 제목/요약/키워드: limit of quantification

검색결과 464건 처리시간 0.026초

Determination of Terbutaline Enantiomers in Human Plasma by Coupled Achiral-Chiral High Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Kim, Hyun-Ju;Hong, Seon-Pyo;Shin, Sang-Deok
    • Archives of Pharmacal Research
    • /
    • 제23권5호
    • /
    • pp.441-445
    • /
    • 2000
  • Achiral-chiral column switching HPLC assay was developed to allow the separation and quantification of the enantiomers of terbutaline in human plasma by means of fluorescence detection. Plasma samples were prepared by solid-phase extraction with sep-pak silica, followed by HPLC assay. The enantiomers of terbutaline and the internal standard were separated from the biological matrix on a silica column, and the two enantiomers were resolved and quantified on a Sumichiral OA-4900 column. The two columns were connected by a switching valve equipped with silica trap column, The trap column was used to concentrate the terbutaline in the eluent from the achiral column before back flushing onto the chiral phase. For each enantiomers, the assay was linear between 2.5-125 ng/$m\ell$ (r=0.9999) and detection limit was 1.0 ng/$m\ell$ .

  • PDF

Analysis of Agrochemical Residues in Tobacco Using QuEChERS Method by GC-MS/MS

  • Lee, Jeong-Min;Jang, Gi-Chul;Hwang, Keon-Joong
    • 한국연초학회지
    • /
    • 제29권2호
    • /
    • pp.132-139
    • /
    • 2007
  • This study was performed to apply the more rapid and accurate sample preparation, and the high selectivity and sensitivity of the analyte detection by gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS). QuEChERS (quick, easy, cheap, effective, rugged and safe) method was validated for 49 agrochemicals in the CORESTA Agrochemical Advisory Committee guide and amenable to GC-MS/MS determination. In QuEChERS method, the effects of sorbents (PSA, $C_{18}$ and GCB) and matrix of the analytes in tobacco types (flue-cured, burley and oriental) were investigated. MS/MS acquisition provided high specificity and selectivity for agrochemicals and low limit of quantification. QuEChERS by using PSA alone and the matrix-matched standards gave good recoveries and RSD values in three types of tobaccos. QuEChERS method was no needed to be complex clean-up procedure and would be used as the fast and easy method for agrochemical residue analysis in tobacco.

On-line SPE-HPLC Method using Alumina Filtering to Selectively Extract Phenolic Compounds from Environmental Water

  • Lee, Sung-Kwang
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권12호
    • /
    • pp.3755-3759
    • /
    • 2010
  • A on-line SPE (solid phase extraction)-HPLC preconcentration method was developed for the determination of phenolic compounds at trace levels in environmental water sample. XAD-4 and Dowex 1-X8 were used as sorbent in the on-line SPE-HPLC method for the selective enrichment of nine phenolic compounds, which are included in the priority pollutants list of the US EPA. Also alumina prefiltering considerably reduced the amount of interfering peaks due to humic substances that could accumulated due to the preconcentration step and prevent quantification of polar phenolic compounds in environmental water samples. This method was used to determine the phenolic compounds in tap and river water and superiority to the US EPA 625 method in its enrichment factor, pretreatment time, recoveries, and detection limit. The limits of detection were in the range of $0.3-0.9\;{\mu}g/L$ in tap water sample.

Determination of Epinephrine Using Sodium Iodate in Chemiluminescence

  • Lee, J.S.;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권12호
    • /
    • pp.2315-2318
    • /
    • 2007
  • Epinephrine was determined using a lab-made chemiluminescence (CL) system with air pump. Luminolsodium IO4? chemiluminescence system was employed to produce the luminescence of epinephrine. In the reaction, epinephrine was oxidized to produce superoxide or singlet oxygen by periodate in alkaline solution, which enhanced CL of luminol. For optimization, various buffers, such as phosphate, borate, and tris, were studied in this experiment. Compared to NaOH, the phosphate and borate buffer showed better reproducibility with similar sensitivity. Small amount of sample, 22 μL, was required for a measurement. The limit of quantification for epinephrine was obtained to be ~10?9 g/mL after optimization.

대기 중 PCBs와 유기염소계 살충제의 정량을 위한 분석 방법 개발 (Development of Analytical Method for Polychlorinated Biphenyls and Organochlorine Pesticides in Air)

  • 최민규;여현규;김태욱;천만영;선우영
    • 한국대기환경학회지
    • /
    • 제18권6호
    • /
    • pp.475-485
    • /
    • 2002
  • An analytical method was investigated for the meaiiurement of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) concentrations in air samples. Procedures required for column chromatographic clean up. silicagel (stage I) and gel permeation chromatography (stage II), were discussed. Identification and quantification of PCBs and OCPs were performed using a combination of gas chromatography/mass spectrometry/ selected ion monitoring. Recovery tests calculated from six samples are 68∼137% for PCBs and 58∼130% for OCPs except for endrin aldehyde. Instrumental detection limits determined for the PCBs and OCPs varied from 0.05 to 0.18 pg/m3 and from 0.71 to 16.82 pg/㎥, respectively. The method has been applied to the analysis of air samples collected at Ansung city, Kyonggi province, Korea. This method may serve as a screening protocol for the simultaneous determination of PCBs and OCPs in air.

A Real-Time PCR Assay for the Quantitative Detection of Ralstonia solanacearum in Horticultural Soil and Plant Tissues

  • Chen, Yun;Zhang, Wen-Zhi;Liu, Xin;Ma, Zhong-Hua;Li, Bo;Allen, Caitilyn;Guo, Jian-Hua
    • Journal of Microbiology and Biotechnology
    • /
    • 제20권1호
    • /
    • pp.193-201
    • /
    • 2010
  • A specific and rapid real-time PCR assay for detecting Ralstonia solanacearum in horticultural soil and plant tissues was developed in this study. The specific primers RSF/RSR were designed based on the upstream region of the UDP-3-O-acyl-GlcNAc deacetylase gene from R. solanacearum, and a PCR product of 159 bp was amplified specifically from 28 strains of R. solanacearum, which represent all genetically diverse AluI types and all 6 biovars, but not from any other nontarget species. The detection limit of $10^2\;CFU/g$ tomato stem and horticultural soil was achieved in this real-time PCR assay. The high sensitivity and specificity observed with field samples as well as with artificially infected samples suggested that this method might be a useful tool for detection and quantification of R. solanacearum in precise forecast and diagnosis.

Impact of High-Level Expression of Heterologous Protein on Lactococcus lactis Host

  • Kim, Mina;Jin, Yerin;An, Hyun-Joo;Kim, Jaehan
    • Journal of Microbiology and Biotechnology
    • /
    • 제27권7호
    • /
    • pp.1345-1358
    • /
    • 2017
  • The impact of overproduction of a heterologous protein on the metabolic system of host Lactococcus lactis was investigated. The protein expression profiles of L. lactis IL1403 containing two near-identical plasmids that expressed high- and low-level of the green fluorescent protein (GFP) were examined via shotgun proteomics. Analysis of the two strains via high-throughput LC-MS/MS proteomics identified the expression of 294 proteins. The relative amount of each protein in the proteome of both strains was determined by label-free quantification using the spectral counting method. Although expression level of most proteins were similar, several significant alterations in metabolic network were identified in the high GFP-producing strain. These changes include alterations in the pyruvate fermentation pathway, oxidative pentose phosphate pathway, and de novo synthesis pathway for pyrimidine RNA. Expression of enzymes for the synthesis of dTDP-rhamnose and N-acetylglucosamine from glucose was suppressed in the high GFP strain. In addition, enzymes involved in the amino acid synthesis or interconversion pathway were downregulated. The most noticeable changes in the high GFP-producing strain were a 3.4-fold increase in the expression of stress response and chaperone proteins and increase of caseinolytic peptidase family proteins. Characterization of these host expression changes witnessed during overexpression of GFP was might suggested the metabolic requirements and networks that may limit protein expression, and will aid in the future development of lactococcal hosts to produce more heterologous protein.

LC/MS/MS를 이용한 비글견의 혈장 중 Doxifluridine 및 5-Fluorouracil의 동시 분석법 Validation (Validation of a Selective Method for Simultaneous Determination of Doxifluridine and 5-Fluorouracil in Dog Plasma by LC-MS/MS)

  • 김기환;김원;김진성;김경일;강원구;이종화;하정헌;정은주
    • Journal of Pharmaceutical Investigation
    • /
    • 제37권3호
    • /
    • pp.179-186
    • /
    • 2007
  • A simple, sensitive and selective liquid chromatographic/tandem mass spectrometric method (LC-MS/MS) was developed and validated for doxifluridine and 5-fluorouracil (5-FU) quantification in dog heparinized plasma. Sample preparation was based on liquid-liquid extraction using a mixture of isopropanol/ethyl acetate (1/9 v/v) to extract doxifluridine, 5-FU and 5-chlorouracil (5-CU, an internal standard) from plasma. Chromatography was performed on a C-18 analytical column and the retention times were 2.7, 1.5 and 1.7 min for doxifluridine, 5-FU and 5-CU, respectively with shorter analysis time within 5 min than previously reported methods. The ionization was optimized using ESI negative mode and selectivity was achieved by tandem mass spectrometric analysis by multiple reaction monitoring (MRM) using the transformations of m/z 244.8>107.6, 129.0>42.0 and 144.9>42.1 for doxifluridine, 5-FU and 5-CU, respectively. The achieved low limit of quantification was 20.0 ng/mL and the assay exhibited linear range of 20-2000 ng/mL ($R^2>0.99957$ for doxifluridine and $R^2>0.99857$ for 5-FU), using $100{\mu}L$ of plasma. Accuracy and precision of quality control samples for both doxifluridine and 5-FU met KFDA and FDA Guidance criteria of 15% for accuracy with coefficients of variation less than 15%. This method demonstrated adequate sensitivity, specificity, accuracy, precision and stability to support the simultaneous analysis of doxifluridine and 5-FU in dog plasma samples in pharmacokinetic and bioequivalence studies.

Simultaneous Determination and Recognition Analysis of Coumarins in Angelica decursiva and Peucedanum praeruptorum by HPLC-DAD

  • Kim, Hye Mi;Jeong, Su Yang;Kim, Sun Min;Lee, Kyu Ha;Kim, Jong Hwan;Seong, Rack Seon
    • Natural Product Sciences
    • /
    • 제22권3호
    • /
    • pp.162-167
    • /
    • 2016
  • Peucedani Radix is the root of Angelica decursiva Franchet et Savatier (=Peucedanum decursivum Maximowicz) or Peucedanum praeruptorum Dunn in several Asian countries. The coumarins contained in Peucedani Radix were quantitatively analyzed using HPLC-DAD to develop a simultaneous determination for the quality control of A. decursiva and P. praeruptorum. For quantitative analysis, four major coumarins contained in these medicinal plants were assessed. Nodakenin (1), nodakenetin (2), praeruptorin A (3), and praeruptorin B (4) were separated with a Phenomenex Luna C18 column ($5{\mu}m$, $4.6{\times}250mm$) under the gradient conditions using distilled water with 0.1% phosphoric acid and acetonitrile with 0.1% phosphoric acid as the mobile phase, at a flow rate of 1.0 ml/min and a detection wavelength of 330 nm. This method was fully validated for linearity, accuracy, precision, recovery, and limit of detection and quantification. As a result, A. decursiva and P. praeruptorum were clearly classified by the quantification of four major coumarins in extracts. Also, the pattern recognition analysis based on HPLC indicates that all of the samples were largely clustered into two groups. Therefore, it is possible to distinguish between A. decursiva and P. praeruptorum and contribute to quality control.

알코올을 주성분으로 하는 손소독제의 안전성 연구 (A Study on the Safety of Alcohol-based Hand Sanitizers)

  • 정선옥;이춘영;류회진;최희진;김지영;최채만;황인숙;신용승
    • 한국산업보건학회지
    • /
    • 제33권1호
    • /
    • pp.34-39
    • /
    • 2023
  • Objectives: In this study, the safety of alcohol-based hand sanitizers (ABHSs) for quasi-drugs and cosmetics was investigated by analyzing the ethanol content, which is an active ingredient with a sterilizing effect, and methanol, which is toxic. Methods: Forty-one ABHSs were purchased at large supermarkets and online stores. Ethanol quantification was performed by gas chromatography-flame ionization detector, and methanol quantification was performed by headspace-gas chromatography-mass spectrometry. Results: The ethanol content of ABHS in quasi-drugs was 49.6-67.8%, which was suitable for standard manufacturing procedures for external disinfectants, and the ethanol content of ABHS in cosmetics was 9.1-61.3%. The methanol content of ABHS in quasi-drugs ranged from not detected(N.D.)-131.8 ppm, which was suitable for the methanol detection standard of ethanol raw materials in the Korean Pharmacopoeia. The methanol content of ABHS in cosmetics was 23.4-859.7 ppm, which was suitable for the detection limit of methanol in cosmetics. Conclusions: The ethanol and methanol content of ABHS was judged to be safe. When selecting an ABHS to be used for sterilization, it seems necessary to check the content of ethanol, an active ingredient, and use it according to its intended purpose.