• Title/Summary/Keyword: limit function

Search Result 1,144, Processing Time 0.033 seconds

Method Validation for the Determination of Eleutherosides and β-Glucan in Acanthopanax koreanum (탐라오가피의 Eleutheroside B, E 및 β-Glucan 함량 분석 및 분석법 검증)

  • Kim, Young-Hyun;Bae, Da-Bin;Park, Sun-Ok;Lee, Sang-Jong;Cho, Ok-Hyun;Lee, Ok-Hwan
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.9
    • /
    • pp.1419-1425
    • /
    • 2013
  • The aim of this study was to investigate the method validation for the determination of eleutherosides (B and E) and ${\beta}$-glucan in Acanthopanax (A.) koreanum. This medicinal plant reportedly mainly included eleutherosides which exhibit the pharmacological effects, and ${\beta}$-glucan substantially enhances the function of the immune system by activating macrophages. The specificity, linearity, precision, accuracy, limit of detection (LOD, S/N=3), and limit of quantification (LOQ, S/N=10) were measured by HPLC and enzymatic methods. Our results showed that the coefficient of calibration correlation ($R^2$) for eleutheroside B and E were 0.9997 and 0.9999, respectively. The limits of detection (LOD) for eleutheroside B and E were $0.050{\mu}g/mL$ and $0.025{\mu}g/mL$, respectively. The recovery rate of eleutheroside B and E were revealed in the high range of 100.66~110.04% and 94.26~111.62%, respectively. The inter-day precision of eleutheroside B and E in the root and stem in A. koreanum were 1.4~5.0% and 1.1~2.5%, respectively. The intra-day precision of eleutheroside B and E in the root and stem in A. koreanum were 2.8~2.9% and 0.4~1.1%, respectively. Furthermore, the inter-day and intra-day precision of ${\beta}$-glucan in the stem, leaf, and fruit of A. koreanum were 1.32~5.67% and 8.01~11.76%, respectively. In conclusion, the methods were validated for the detection of eleutherosides and ${\beta}$-glucan in A. koreanum.

Study on High Sensitivity Metal Oxide Nanoparticle Sensors for HNS Monitoring of Emissions from Marine Industrial Facilities (해양산업시설 배출 HNS 모니터링을 위한 고감도 금속산화물 나노입자 센서에 대한 연구)

  • Changhan Lee;Sangsu An;Yuna Heo;Youngji Cho;Jiho Chang;Sangtae Lee;Sangwoo Oh;Moonjin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.spc
    • /
    • pp.30-36
    • /
    • 2022
  • A sensor is needed to continuously and automatically measure the change in HNS concentration in industrial facilities that directly discharge to the sea after water treatment. The basic function of the sensor is to be able to detect ppb levels even at room temperature. Therefore, a method for increasing the sensitivity of the existing sensor is proposed. First, a method for increasing the conductivity of a film using a conductive carbon-based additive in a nanoparticle thin film and a method for increasing ion adsorption on the surface using a catalyst metal were studied.. To improve conductivity, carbon black was selected as an additive in the film using ITO nanoparticles, and the performance change of the sensor according to the content of the additive was observed. As a result, the change in resistance and response time due to the increase in conductivity at a CB content of 5 wt% could be observed, and notably, the lower limit of detection was lowered to about 250 ppb in an experiment with organic solvents. In addition, to increase the degree of ion adsorption in the liquid, an experiment was conducted using a sample in which a surface catalyst layer was formed by sputtering Au. Notably, the response of the sensor increased by more than 20% and the average lower limit of detection was lowered to 61 ppm. This result confirmed that the chemical resistance sensor using metal oxide nanoparticles could detect HNS of several tens of ppb even at room temperature.

Development of Deterioration Prediction Model and Reliability Model for the Cyclic Freeze-Thaw of Concrete Structures (콘크리트구조물의 반복적 동결융해에 대한 수치 해석적 열화 예측 및 신뢰성 모델 개발)

  • Cho, Tae-Jun;Kim, Lee-Hyeon;Cho, Hyo-Nam
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.1
    • /
    • pp.13-22
    • /
    • 2008
  • The initiation and growth processes of cyclic ice body in porous systems are affected by the thermo-physical and mass transport properties, as well as gradients of temperature and chemical potentials. Furthermore, the diffusivity of deicing chemicals shows significantly higher value under cyclic freeze-thaw conditions. Consequently, the disintegration of concrete structures is aggravated at marine environments, higher altitudes, and northern areas. However, the properties of cyclic freeze-thaw with crack growth and the deterioration by the accumulated damages are hard to identify in tests. In order to predict the accumulated damages by cyclic freeze-thaw, a regression analysis by the response surface method (RSM) is used. The important parameters for cyclic freeze-thawdeterioration of concrete structures, such as water to cement ratio, entrained air pores, and the number of cycles of freezing and thawing, are used to compose the limit state function. The regression equation fitted to the important deterioration criteria, such as accumulated plastic deformation, relative dynamic modulus, or equivalent plastic deformations, were used as the probabilistic evaluations of performance for the degraded structural resistance. The predicted results of relative dynamic modulus and residual strains after 300 cycles of freeze-thaw show very good agreements with the experimental results. The RSM result can be used to predict the probability of occurrence for designer specified critical values. Therefore, it is possible to evaluate the life cycle management of concrete structures considering the accumulated damages due to the cyclic freeze-thaw using the proposed prediction method.

Optimal Ccontrol Strategy of Cooling System for Polymer Electrolyte Membrane Fuel Cell using Hardware-In-the-Loop Simulation (Hardware-In-the-Loop Simulation을 이용한 고분자 전해질 연료전지 냉각시스템 최적 제어기법 연구)

  • Choi, Eunyeong;Ji, Hyunjin
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.113-121
    • /
    • 2016
  • Polymer electrolyte membrane fuel cell(PEMFC) requires cooling system to maintain the proper operating temperature(about $65^{\circ}C{\sim}75^{\circ}C$) because the efficiency and power are affected by operating temperature. In order to retain the operating temperature of PEMFC, cooling system and coolant control logic are needed. Hardware-in-the-loop simulation(HILS) is one of effective methods to study and evaluate control algorithm. In this paper, the HILS system was designed to study the coolant control algorithm. The models of HILS system consisted of PEMFC, heat exchanger, and external environment associated with temperature. The hardwares in HILS system are 3-way valves, pumps, and a heat exchanger. The priority control and the control target temperature were investigated to improve the control performance using HILS. The 3-way valve in $1^{st}$ cooling circuit was selected as priority control target. The under limit value of $2^{nd}$ 3-way valve set as a function of PEMFC power and $2^{nd}$ circuit coolant temperature to correct temperature control performance. As a result, the temperature of PEMFC is stably controlled.

Residue of Combined Insecticide of Polynactin Complex(Tetranactin) and BPMC in Apple and Soil (Polynactin Complex (Tetranactin)와 BPMC 혼합제의 사과 및 토양 잔류성)

  • Yoon, Jae Cheon;Lee, Seok Joon;Park, Jong Woo;Kim, Jang Eok
    • Current Research on Agriculture and Life Sciences
    • /
    • v.11
    • /
    • pp.101-110
    • /
    • 1993
  • The residues of combined insecticide of polynactin complex(tetranactin) and BPMC were determined to establish an index for the safety use to apple. Evaluation was made on residual concentration of tetranactin and BPMC in apple as a function of application frequency and date when the combined insecticide of tetranactin and BPMC was sprayed into apple. Their persistence in soil were also studied under the field and laboratory conditions. Recovery percentage from apple was ranged from 74.0 to 77.5 in tetranactin, 87.1 to 83.6 in BPMC, those from soil was 82.3 to 88.4 in tetranactin, 83.6 to 887.1 in BPMC. The minimum detectable limits of tetranactin and BPMC were 0.01ppm in apple pulp and 0.03ppm in apple peel and soil. The residue percentage of tetranactin and BPMC in the peel and pulp part of apple was about 96 in peel part by five sprays up to 3th day before harvest. The residues of tetranactin and BPMC in apple are proved to 0.39ppm and 0.75ppm by five sprays up to 30days before harvest. Maximum residue limit(MRL) of BPMC for fruits was established of 0.3ppm in Environment Protection Agency of Korea, and thus it is suggested that the preharvest intervals of combined insecticide for apple could be 30 days with twice spray. The half life of tetranactin in soil under field and laboratory conditions was 6.9 and 24.4 days, and in case of BPMC was 6.3 and 23.2 days, respectively.

  • PDF

A Study on Design and Construction Methods of Movable Pavilions (이동식 정자의 설계 시공법 연구)

  • Lee, Jung-Han
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.4
    • /
    • pp.51-59
    • /
    • 2019
  • This study aims to examine the design and construction methods of movable Pavilions. Through the literature analysis, the setting up of the construction background, location and direction, size and composition, materials and construction methods were analyzed. The results are as follows; First, the movable pavilion is designed to enjoy a wide range of views. It was a creation that reflected the way in which the ideal life was pursued based on the experience of enjoying scenery rather than owning one's own house and running a pavilion. Second, the formation of movable pavilion was intended to enjoy the scenery by season without restrictions on time and place. It can also relieve the hassle of having to move tools to enjoy the wind every time. Third, the movable pavilion faces to a place with good scenery and determines its position and direction. Most of them were built on a small scale and divided the space for viewing the scenery, playing GO(Baduk), writing poems, and playing musical instruments. Also, wood was used mainly. To reduce the load, roofs and walls were constructed with light materials such as bamboo, straw, thick sheet of oil, and cotton cloth. The construction method was mainly used by the method of fastening for easy coupling and dismantling. When a building was constructed on the upper part of a ship or cart, the wooden structure of a regular pavilion was constructed. Fourth, when comparing the design and construction characteristics of ordinary pavilion and movable pavilion, the movable pavilion is easy to see for contrast purposes, so there is no limit to setting the location and direction. Instead, more stringent systems and techniques were called for, because as mobility forces should be considered, structurally measures to withstand loads, and they should satisfy their function and form as pavilion.

A noise reduction method for MODIS NDVI time series data based on statistical properties of NDVI temporal dynamics (MODIS NDVI 시계열 자료의 통계적 특성에 기반한 NDVI 데이터 잡음 제거 방법)

  • Jung, Myunghee;Jang, Seok-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.24-33
    • /
    • 2017
  • Multitemporal MODIS vegetation index (VI) data are widely used in vegetation monitoring research into environmental and climate change, since they provide a profile of vegetation activity. However, MODIS data inevitably contain disturbances caused by the presence of clouds, atmospheric variability, and instrument problems, which impede the analysis of the NDVI time series data and limit its application utility. For this reason, preprocessing to reduce the noise and reconstruct high-quality temporal data streams is required for VI analysis. In this study, a data reconstruction method for MODIS NDVI is proposed to restore bad or missing data based on the statistical properties of the oscillations in the NDVI temporal dynamics. The first derivatives enable us to examine the monotonic properties of a function in the data stream and to detect anomalous changes, such as sudden spikes and drops. In this approach, only noisy data are corrected, while the other data are left intact to preserve the detailed temporal dynamics for further VI analysis. The proposed method was successfully tested and evaluated with simulated data and NDVI time series data covering Baekdu Mountain, located in the northern part of North Korea, over the period of interest from 2006 to 2012. The results show that it can be effectively employed as a preprocessing method for data reconstruction in MODIS NDVI analysis.

Characteristics and Policy Implications of Private Development Parks in Japan (일본 민설공원 제도의 특성과 시사점)

  • Kim, Hyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.1
    • /
    • pp.119-128
    • /
    • 2016
  • Urban park planning has become difficult due to the lack of municipal funds. Thereupon, a special scheme was imposed for city park planning. Since then, a legal amendment was made for economical improvement and more active participation. However, there are a lot of questions about whether it was a suitable direction for parks and where it should be emphasized for public interest. Base on these concerns, this study examined the basis and characteristics of location, creation, and maintenance of private development parks in Japan, which was the policy model of Korean private parks. Location and space planning of private development parks was made up considering an effective green network and disaster prevention function, and a minimum area was about 1.42ha. The minimum area, 1ha, was established on the basis of considering realistic possibilities, disaster protection, and universal validity. It was also amended to consider the standard of type two mid- to high-rise exclusive residential areas and consultation with regional governance. Finally, it was built on the lowest limit of ordinance of the relevant city; for example, 100% of the floor area ratio, 30% of the building coverage ratio, and the maximum height of 11 stories, etc. For maintenance, private and public sectors were working together. Maintenance fees for 35 years (based on $300yen/m^2$ per month) were paid en bloc by the licensee. However, the city was paid for facilities that accompanied excessive maintenance costs. Meanwhile, it seemed difficult to introduce attractive profit facilities because of the limitations in location, usage permission, and introduction equipment; furthermore, there were problems with management authority, and the burden of expenses was deducted. For creating private Korean parks, this study suggested that we should build priority of creating city parks and select appropriate locations first; also, we need to make criteria for location, creation, and standard management rules that are relevant to the whole nation of Korea.

Confining Effect of Mortar Grouted Splice Sleeve on Reinforcing Bar (모르타르 충전식 철근이음과 구속효과)

  • Ahn, Byung-Ik;Kim, Hyong-Kee;Park, Bok-Man
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.1
    • /
    • pp.102-109
    • /
    • 2003
  • The grouted splice steeve has been applied widely due to its superior construction efficiency, such as the unnecessity of post concrete and the large allowable limit to the arrangement of reinforcing bars. However, studies on grout-filled splice steeve still have not been sufficiently peformed. The purpose of this study is to investigate the confining effect of mortar grouted splice sleeve on reinforcing bar, known to strengthen the bond capacity between grout mortar and reinforcing bar. To accomplish this objective, totally 6 full-sized specimens were made and tested under monotonic loading. Each specimens were equipped with strain gauges at the 12 location of sleeve and reinforcing bar. The experimental variables adopted in this study are embedment length and size of reinforcing bars. Following conclusions are obtained; 1) Under ultimate strength condition, the confining pressure of grouted splice sleeve calculated from measured tangential and axial strain of the sleeve is over $200{\sim}300kgf/{cm}^2$ at any location of sleeve and improved with reduction in embedment length of reinforcing bar. 2) Untrauer and Henry's equation which describe bond strength of mortar as a function of its compressive strength and confining pressure, predicted the measured bond capacity of this test within the 5% limits.

Assessment of System Reliability and Capacity-Rating of Concrete Box-Girder Highway Brdiges (R.C 박스거교의 체계신뢰성 해석 및 안전도 평가)

  • 조효남;신재철
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.3
    • /
    • pp.187-198
    • /
    • 1995
  • This paper develops practical and reallstic reliabllity models and methods for the evaluation of system rehability and system rellabllity based ratlng of R.C box glrder bridge superstructures. The precise prediction of reberved carrying capacity of bridge as d system is extremely difficult especially when the brldges are highly redundant and slgnlficantly deter 1or;itcd or dainagetl. Thls papel proposes a nt2w approach for the evaluation of reseived system c,drrying capaaty of br~dges in terms ot equ~vdleiit system strength, which may b~ ddcflned as a brtdge system strength correipcmdlng tu the system rehability of the bridge. This cm be ticrAvcd from an Inverse process bami or1 the con~ept of FOSM(F1rst Order Second Moment) form of system reliabihty index. The sf rength llmt state models for K C box girder br~dges suggested In the paper dre based on the basi~ bending and shear strength And thc system reliatxllty pro,~lerri of box gritier super structure 1s formuldted as parallel serles models obtalncd f ~ o m thc FMA(Fdilure blode Rp proath) based on major failure mc>clmusrns or c~itlcal fdure ,>tatcs of each nuder .WOSM(Ad-vanced First Order Second Moment) and IST(1mportance Sampling Technique) simulation algorithm are used for the reliability analysis of the proposed models.