• Title/Summary/Keyword: lighting simulation

Search Result 351, Processing Time 0.022 seconds

A Study on the Comparison of the Illuminance Values from Daylight Simulation and Mock-up Experiment for Suitable Application of Lighting Simulation (적합한 조명시뮬레이션 사용을 위한 주광 시뮬레이션과 Mock-up 실험 비교에 관한 연구)

  • Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.35-44
    • /
    • 2010
  • Available daylight in inside offers comfortable view environment, and psychological and physical advantages to people in a room. Architectural design has a need for daylight prediction. But it is difficult to predict the illuminance values in daylight system. Using various Daylight simulation software is easy and simple, but we can find different results under the same conditions. This study compares with illuminance values from simulation (Lightscape 3.2, Relux 2007, Radiance 3.9) and Mock-up experiment with a same space and parameter of daylight (location of space and window, date, time and sky condition).

Essential Computer Vision Methods for Maximal Visual Quality of Experience on Augmented Reality

  • Heo, Suwoong;Song, Hyewon;Kim, Jinwoo;Nguyen, Anh-Duc;Lee, Sanghoon
    • Journal of International Society for Simulation Surgery
    • /
    • v.3 no.2
    • /
    • pp.39-45
    • /
    • 2016
  • The augmented reality is the environment which consists of real-world view and information drawn by computer. Since the image which user can see through augmented reality device is a synthetic image composed by real-view and virtual image, it is important to make the virtual image generated by computer well harmonized with real-view image. In this paper, we present reviews of several works about computer vision and graphics methods which give user realistic augmented reality experience. To generate visually harmonized synthetic image which consists of a real and a virtual image, 3D geometry and environmental information such as lighting or material surface reflectivity should be known by the computer. There are lots of computer vision methods which aim to estimate those. We introduce some of the approaches related to acquiring geometric information, lighting environment and material surface properties using monocular or multi-view images. We expect that this paper gives reader's intuition of the computer vision methods for providing a realistic augmented reality experience.

Development of High Efficiency and High Power LED Package for Applying Silicone-Reflector (실리콘 리플렉터를 적용한 고효율 고출력 LED 패키지 개발)

  • Jeong, Hee-Suk;Lee, Young-Sik;Lee, Jung-Geun;Kang, Han-Lim;Hwang, Myung-Keun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.1-5
    • /
    • 2013
  • We developed high-efficient 6W-LED package with simple structure by applying Heat Slug and silicone-reflector. LED package was manufactured in $8.5{\times}8.5mm$ sized multi-chip structure having thickness of $500{\mu}m$ achieved by bonding silicon-reflector with prepreg on top of the plate after implementing the reflector placed on copper substrate Half Etching by thickness of $200{\mu}m$. The luminous flux, luminous efficacy, correlated color temperature, color rendering index and thermal resistance of developed LED was evaluated, and it verified the application of products by applying it to 120W-LED road luminaires through simulation. The luminous efficacy of LED package reached over 130lm/W, and it is possible to be manufactured into 120W-LED road luminaires using 18 packages. In addition, the simulation results showed average of horizontal illuminance and overall illuminance uniformity that is suitable for three-lane road.

Accuracy Evaluation of the Three-Curve Method and the Zonal Cavity Method (3배광법과 구역공간법의 정확도 평가)

  • Sim, Sang-Man;Kim, Chang-Seop;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.53-59
    • /
    • 1995
  • The accurcy and the application limits of the Three-Curve Method(TCM) and Zonal Cavity Method(ZCM) are evaluated. Average illuminance values are calculated by TCM and ZCM for various lighting conditions using general Diffusing Luminaires and Direct Luminaires. These values are compared with the values from Monte-Carlo Simulation(MCS) for the same lighting conditions. Accuracy of MCS was proved by Moon's Analytical Method.

  • PDF

Energy Performance Evaluation of Building Micro-grid System Including Micro-turbine in Hospital Buildings (마이크로터빈이 포함된 빌딩마이크로그리드시스템의 병원건물의 에너지성능평가)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.279-283
    • /
    • 2009
  • Distributed generation(DG) of combined cooling, heat. and power(CCHP)has been gaining momentum in recent year as efficient, secure alternative for meeting increasing energy demands. This paper presents the energy performance of microturbine CCHP system equipped with an absorption chiller by modelling it in hospital building. The orders of study were as following. 1)The list and schedule of energy consumption equipment in hospital were examined such as heating and cooling machine, light etc. 2) Annual report of energy usage and monitoring data were examined as heating, cooling, DHW, lighting, etc. 3) The weather data in 2007 was used for simulation and was arranged by meteorological office data in Daejeon. 4) Reference simulation model was built by comparison of real energy consumption and simulation result by TRNSYS and ESP-r. The energy consumption pattern of building were analyzed by simulation model and energy reduction rate were calculated over the cogeneration. As a result of this study, power generation efficiency of turbine was about 30% after installing micro gas turbine and lighting energy as well as total electricity consumption can be reduced by 40%. If electricity energy and waste heat in turbine are used, 56% of heating energy and 67% of cooling energy can be reduced respectively, and total system efficiency can be increased up to 70%.

  • PDF

The Glass Greenhouse's Lighting Simulation for Ginseng with Solar Cell and LED (태양전지와 LED를 이용한 인삼재배용 유리온실의 조도 시뮬레이션)

  • Lee, Boong-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.14-19
    • /
    • 2019
  • In this study, the Relux illumination program was used to simulate the optimal lighting design for a glass greenhouse with Si and DSSC solar-cells and LEDs. The results of the daylight simulation show that the optimum conditions were a structure angle of 90o and higher transmittance. The results of the illumination simulation produced a power consumption effect of 5.6 kwh in the summer (42[%] energy savings compared to full LED control) and 7.8 kwh in the winter (58[%] energy savings compared to full LED control). The results suggest that ginseng should be grown in an energy-saving glass greenhouse.

Analysis of the Change of Intensity Distribution and Luminous Environment by Reflector Shape in Indirect Reflected LED Luminaires (간접 반사형 LED 조명기구의 반사판 형태에 따른 배광형태 및 조명환경 변화 분석)

  • Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.9-17
    • /
    • 2011
  • Development of high efficiency and eco-friendly LED source has been progressed continuously. Also, by nation's regulations, public institutions have changed existing luminaires to LED luminaires. However, there are several differences between existing luminaires and the intensity distribution of general planar LED luminaires. In case of changing existing luminaires to LED luminaires, by such differences, there are inefficiencies both quality aspect and energy aspect in luminous environment. Therefore, this study aims to conduct a study on the changes of intensity distribution and luminous environment by reflector shapes in indirect reflected LED luminaires with software for optical design of a luminaire (Photopia 2.0) and lighting design of a space (ReluxPro). This study shows the changes of intensity distribution and luminous environment of indirect reflected LED luminaires and indirect fluorescent lamp luminaires by reflector shapes.

A Study on the Generation and Application of Photometric Data for Lighting Simulation (조명 시뮬레이션을 위한 측광데이터의 생성과 적용)

  • Hong, Sung-De
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.6 no.2
    • /
    • pp.25-30
    • /
    • 2006
  • The purpose of this study was to investigate how student felt the strengths and shortness of presentation methods for formation of interior spaces. For this study, the process of the interior architecture design class was divided into three stages: the programming. the design development, and the design completion. In the design development stage, students used presentation methods: hand sketch, scale model, computer modeling, and virtual realty. The strengths of hand sketch was that quick expression. Models provided three-dimensional feelings. Computer modelling provide realistic color and texture. Virtual reality provided three-dimensional immersion and real scale. It is effective that students collect brain storm images using quick hand sketch in the beginning of design development stage. After that, they compose interior spaces in study models with small scale. Watching the models, they design details of spaces by using hand sketch and computer modelling. Using virtual reality, they can check the scale and circulation. Finally, they complete computer modelling by texture mapping and check the final design in virtual reality.

  • PDF

A Study of Concentric-Neutral Line Voltage Increase Related by Pole and Cable Joint When Lightening Overvoltage Injected in Combined Distribution Line (혼합 배전선로에 직격낙뢰시 전주와 케이블직선접속재가 케이블 동심중성선 전위상승에 미치는 영향)

  • Jeon, Yong-Joo;Jeon, Myung-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.702-707
    • /
    • 2018
  • In case of Lighting occurs in Domestic combined distribution line, normally the voltage for the neutral line increase dramatically. General connection for underground cable is bundled common earth type so the lightning over voltage increase at the concentric-neutral line is not big enough to give impact on cable sheath. But in case of Non bundled common earth type it is necessary to analyze the phenomena on cable sheath caused by lightening overvoltage. Especially pole and cable joint are the core factor to consider. In this paper concrete pole and cable joint were evaluated in case of Non bundled common earth type combined distribution Line. EMTP simulation model has been designed and several case study were made. Also several experimental test were made to verify the simulation result.

Computer Simulation on the Characteristics of Daylight Distributions by Grating Louver System in a Pair Glass (복층유리 격자루버시스템의 주광특성에 관한 시뮬레이션 평가)

  • Park, Byoung-Chul;Choi, An-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.117-120
    • /
    • 2009
  • New shading system, which is Grating Louver System into a pair glass, is proposed for integrated lighting system between Daylight Responsive Dimming Systems and shading system in this study. The optimized distance of louvers, which is to block direct sunlight into a space, is calculated. Grating Louver System was simulated using Desktop Radiance 2.0 of lighting simulation software for comparing daylight distribution and changes of control slope by distance from window to back wall with roller shading system controlled by sun profile angle.

  • PDF