• 제목/요약/키워드: light graph

Search Result 54, Processing Time 0.029 seconds

Comparison of Center Error or X-ray Field and Light Field Size of Diagnostic Digital X-ray Unit according to the Hospital Grade (병원 등급에 따른 X선조사야와 광조사야 간의 면적 및 중심점 오차 비교)

  • Lee, Won-Jeong;Song, Gyu-Ri;Shin, Hyun-yi
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.245-252
    • /
    • 2020
  • The purpose of this study was intended to recognize the importance of quality control (QC) in order to reduce exposure and improve image quality by comparing the center-point (CP) of according to hospital grade and the difference between X-ray field (XF) and light field (LF) in diagnostic digital X-ray devices. XF and LF size, CP were measured in 12 digital X-ray devices at 10 hospitals located in 00 metropolitan cities. Phantom was made in different width respectively, using 0.8 mm wire after attaching to the standardized graph paper on transparent plastic plate and marked as cross wire in the center of the phantom. After placing the phantom on the table of the digital X-ray device, the images were obtained by shooting it vertically each field of survey. All images were acquired under the same conditions of exposure at distance of 100cm between the focus-detector. XF and LF size, CP error were measured using the picture archiving communication system. data were expressed as mean with standard error and then analyzed using SPSS ver. 22.0. The difference in field between the XF and LF size was the smallest in clinic, followed by university hospitals, hospitals and general hospitals. Based on the university hospitals with the least CP error, there was a statistically significant difference in CP error between university hospitals and clinics (p=0.024). Group less than 36-month after QC had fewer statistical errors than 36-month group (0.26 vs. 0.88, p=0.036). The difference between the XF and LF size was the lowest in clinic and CP error was the lowest in university hospital. Moreover, hospitals with short period of time after QC have fewer CP error and it means that introduction of timely QC according to the QC items is essential.

Composition of Curriculums and Textbooks for Speed-Related Units in Elementary School (초등학교에서 속력 관련 단원의 교육과정 및 교과서 내용 구성에 관한 논의)

  • Jhun, Youngseok
    • Journal of Korean Elementary Science Education
    • /
    • v.41 no.4
    • /
    • pp.658-672
    • /
    • 2022
  • The unique teaching and learning difficulties of speed-related units in elementary school science are mainly due to the student's lack of mathematical thinking ability and procedural knowledge on speed measurement, and curriculums and textbooks must be constructed with these in mind. To identify the implications of composing a new science curriculum and relevant textbooks, this study reviewed the structure and contents of the speed-related units of three curriculums from the 2007 revised curriculum to the 2015 revised curriculum and the resulting textbooks and examined their relevance in light of the literature. Results showed that the current content carries the risk of making students calculate only the speed of an object through a mechanical algorithm by memorization rather than grasp the multifaceted relation between traveled distance, duration time, and speed. Findings also highlighted the need to reorganize the curriculum and textbooks to offer students the opportunity to learn the meaning of speed step-by-step by visualizing materials such as double number lines and dealing with simple numbers that are easy to calculate and understand intuitively. In addition, this paper discussed the urgency of improving inquiry performance such as process skills by observing and measuring an actual object's movement, displaying it as a graph, and interpreting it rather than conducting data interpretation through investigation. Lastly, although the current curriculum and textbooks emphasize the connection with daily life in their application aspects, they also deal with dynamics-related content somewhat differently from kinematics, which is the main learning content of the unit. Hence, it is necessary to reorganize the contents focusing on cases related to speed so that students can grasp the concept of speed and use it in their everyday lives. With regard to the new curriculum and textbooks, this study proposes that students be provided the opportunity to systematically and deeply study core topics rather than exclude content that is difficult to learn and challenging to teach so that students realize the value of science and enjoy learning it.

Sea Cucumber (Stichopus japonicus) Grading System Based on Morphological Features during Rehydration Process (수화 시의 형태학적 특징에 따른 건해삼의 등급 분류 시스템 개발)

  • Lee, Choong Uk;Yoon, Won Byong
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.3
    • /
    • pp.374-380
    • /
    • 2017
  • Image analysis and k-mean clustering were conducted to develop a grading system of dried sea cucumber (SC) based on rehydration rate. The SC images were obtained by taking pictures in a box under controlled light conditions. The region of interest was extracted to depict the shape of the SC in a 2D graph, and those 2D shapes were rendered to build a 3D model. The results from the image analysis provided the morphological features of the SC, including length, width, surface area, and volume, to obtain the parameters of the k-mean clustering weight. The k-mean clustering classified the SC samples into three different grades. Each SC sample was rehydrated at $30^{\circ}C$ for 40 h. During rehydration, the flux of each grade was analyzed. Our study demonstrates that the mass transfer rate of SC increased as the surface area increased, and the grade of SC was classified based on rehydration rate. This study suggests that the optimal rehydration process for SC can be achieved by applying a suitable grading system.

Moth Diversity (Insecta: Lepidoptera) of Bulgapsan Mountain, Younggwang, Jeonnam (전라남도 영광군 불갑산 나방 (곤충강: 나비목) 다양성 연구)

  • Choi, Sei-Woong;Jang, Beom-Jun;Lee, Jae-Young;Kim, Nang-Hee
    • Korean Journal of Environmental Biology
    • /
    • v.35 no.1
    • /
    • pp.47-56
    • /
    • 2017
  • This study investigates the spatial and temporal variations of moth diversity of Bulgapsan Mountain, Younggwang, Jeonnam. Moth collecting was carried out using a UV light trap at three different sites from February to October 2016 (5 times). A total of 177 moth species and 911 individuals in 17 families were identified. The family Geometridae (51 species and 282 individuals) was the most dominant in the numbers of species and individuals, followed by Erebidae (46 species, 248 individuals), Noctuidae (34 species, 219 individuals) and others. Seasonal change of the number of species and individuals showed a M-shaped pattern with May and July peaks. The Chao 1 estimated number of species using the observed species was 224~326 species, but the graph did not reach an asymptote. Among the surveyed sites, the Neolitsea sericea community showed the highest numbers of species and individuals.

Maximum Pressure and the Blast Wave Analysis of a Amount of HMX (HMX의 양에 따른 최대압력 및 폭풍파속도 분석)

  • Kwon, Hweeung;Tak, Kyongjae;Kim, Junghwan;Oh, Min;Chae, Jooseung;Kim, Hyeonsoo;Moon, Il
    • Korean Chemical Engineering Research
    • /
    • v.52 no.6
    • /
    • pp.706-712
    • /
    • 2014
  • Explosives are reactive material that contain a great amount of high potential energy. They produce detonation if released suddenly, accompanied by the production of strong light, high heat, great noise and high pressure. Damage at surrounding detonation point is affected by high pressure and blast wave for explosives detonation. Consequently, analysis of pressure and blast wave is very important. This study focuses on the analysis of maximum overpressure and blast wave of explosives for safety assurance. First of all, four cases of the amount of HMX were selected. Secondly, maximum pressure and blast wave were calculated through detonation simulation along with a set of TNT and HMX quantities. The peripheral effect of detonation point was analyzed by calculating overpressure and absolute velocity and considering detonation occurred in the center of geometry by HMX. Also, maximum overpressure and blast wave of HMX were compared to equivalent amount of TNT, which was taken as a base case and verified through theoretical HMX graph. This study contributes to the base case for overpressure and blast wave of complex gunpowder containing HMX.

The Effects of Pulsed Electromagnetic Energy and Microcurrent on Wound Healing in Rabbits. (맥동전자장에너지의 미세전류가 가토의 상처치유에 미치는 영향)

  • Kwon Won-An;Park Rae-Joon;Park Youn-Ki;Hwang Tae-Yeun
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.3
    • /
    • pp.319-329
    • /
    • 2000
  • The purpose of this study w8s to evaluate the effects of pulsed electromagnetic energy(Diapulse) and microcurrent on the wound healing in rabbits. 15 domestic rabbits were randomly assigned to the PRME(n=5). MC(n=5) and CON(n=91 group. Each rabbits were anesthetized with lidocaine HCL $2\%$. Skin wounds were created laterally on the back of IS domestic rabbits(33cm). From 24 hours after being injured, the rabbits of the PEME group were irradiated with an intensity of 3 at a 300 pulses per second, which were applied for 15 minutes every day during the 12 days. The MC group were stimulated with an intensity of $50{\mu}A$ at frequency of40 pulses per second, which were applied for 15 minutes every day during the 12 days. The CON group were not stimulated. The rabbits were sacrificed and the incised wound pans were processed appropriately for the light microscopic examination on the 3rd day, 6th day and 12th day before the beginning of wound treatment. The areas of wound were measured with metric graph paper. The results were as tallows. 1 The PRME and MC group compared with control group showed that wound closure rate increased on 6th, 12th day. 2. It was found that the CON group did not show a complete maturation and had a chronic inflammatory response. Judging from the irregularity of intercellular space and the loose alignment of connective tissue. these findings showed that wound healing was delayed. 3. It showed that inflammatory cells. fibroblasts and epithelial cells activity rapidly processed in the PEME group compared with the CON group. It was found that the PEMI; group showed a advanced remodeling of epithelial layer and a positive repair of connective tissue. 4. It showed that fibroblasts, epithelial cells and inflammatory cells activity rapidly processed in the MC group compared with the CON group. It was found that the MC group showed a improved remodeling of epithelial layer and a dense connective tissue.

  • PDF

Investigating Organ Toxicity Profile of Tenofovir and Tenofovir Nanoparticle on the Liver and Kidney: Experimental Animal Study

  • Peter, Aniekan Imo;Naidu, Edwin CS;Akang, Edidiong;Ogedengbe, Oluwatosin O;Offor, Ugochukwu;Rambharose, Sanjeev;Kalhapure, Rahul;Chuturgoon, Anil;Govender, Thirumala;Azu, Onyemaechi O
    • Toxicological Research
    • /
    • v.34 no.3
    • /
    • pp.221-229
    • /
    • 2018
  • Tenofovir nanoparticles are novel therapeutic intervention in human immunodeficiency virus (HIV) infection reaching the virus in their sanctuary sites. However, there has been no systemic toxicity testing of this formulation despite global concerns on the safety of nano drugs. Therefore, this study was designed to investigate the toxicity of Tenofovir nanoparticle (NTDF) on the liver and kidney using an animal model. Fifteen adult male Sprague-Dawley (SD) rats maintained at the animal house of the biomedical resources unit of the University of KwaZulu-Natal were weighed and divided into three groups. Control animals (A) were administered with normal saline (NS). The therapeutic doses of Tenofovir (TDF) and nanoparticles of Tenofovir (NTDF) were administered to group B and C and observed for signs of stress for four weeks after which animals were weighed and sacrificed. Liver and kidney were removed and fixed in formal saline, processed and stained using H/E, PAS and MT stains for light microscopy. Serum was obtained for renal function test (RFT) and liver function test (LFT). Cellular measurements and capturing were done using ImageJ and Leica software 2.0. Data were analysed using graph pad 6, p values < 0.05 were significant. We observed no signs of behavioural toxicity and no mortality during this study, however, in the kidneys, we reported mild morphological perturbations widening of Bowman's space, and vacuolations in glomerulus and tubules of TDF and NTDF animals. Also, there was a significant elevation of glycogen deposition in NTDF and TDF animals when compared with control. In the liver, there were mild histological changes with widening of sinusoidal spaces, vacuolations in hepatocytes and elevation of glycogen deposition in TDF and NTDF administered animals. In addition to this, there were no significant differences in stereological measurements and cell count, LFT, RFT, weight changes and organo-somatic index between treatment groups and control. In conclusion, NTDF and TDF in therapeutic doses can lead to mild hepatic and renal histological damage. Further studies are needed to understand the precise genetic mechanism.

Preparation and Dielectric Behavior of D-Glass with Different Boron Contents (보론함량에 따른 D-glass의 유전율 특성)

  • Jeong, Bora;Lee, Ji-Sun;Lee, MiJai;Lim, Tae-Young;Lee, Youngjin;Jeon, Dae-Woo;Shin, Dongwook;Kim, Jin-Ho
    • Korean Journal of Materials Research
    • /
    • v.27 no.1
    • /
    • pp.39-42
    • /
    • 2017
  • E-glass (electrical glass) fiber is the widely used as a reinforced composite material of PCBs (printed circuit boards). However, E-glass fiber is not stable because it has a dielectric constant of 6~7. On the other hand, D-glass (dielectric glass) fiber has a low dielectric constant of 3~4.5. Thus, it is adaptable for use as a reinforcing material of PCBs. In this study, we fabricated D-glass compositions with low dielectric constant, and measured the electrical and optical properties. In the glass composition, the boron content was changed from 9 to 31 wt%. To confirm the dependence of the dielectric constant on melting properties, D-glass with 22 wt% boron was melted at $1550^{\circ}C$ and $1650^{\circ}C$ for 2hrs. The glass melted at $1650^{\circ}C$ had a lower dielectric constant than the glass melted at $1550^{\circ}C$. Therefore, the D-glass with boron of 9~31 wt% was fabricated by melting at $1650^{\circ}C$ for 2hrs, and transparent clear glass was obtained. We identified the non-crystalline nature of the glass using an XRD (x-ray diffractometer) graph. The visible light transmittance values depending on the boron contents were measured and found to be 88.6 % ~ 82.5 %. Finally, the dielectric constant of the D-glass with 31 wt% boron was found to have decreased from 4.18 to 3.93.

Development of New Prototype of Mechanical Quality Assurance for Clinical Linear Accelerator (의료용 선형가속기의 기계적 점검을 위한 새로운 정도관리 프로토콜의 개발)

  • 윤형근;신교철;김기환;오영기;김진기;정동혁;김정기;조문준;박인규
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.109-113
    • /
    • 2002
  • In recent years, the radiotherapy equipment has become much more sophisticated, and with the complication comes an increased set of quality assurance (QA) responsibilities. Today's computer controlled linear accelerator requiring QA of not only the radiation integrity, but also the mechanical accuracy of the linear accelerator. The existing QA sheets are adequate for acceptance testing and commissioning but those sheets are somewhat descriptive form for routine QA. establishing the QA sheets for a facility are more efficient if the sheets could estimate the long-term stability for the result of QA. We are going to develope new prototype of mechanical QA sheet to visualize and to verify long-term stability of mechanical QA for clinical linear accelerator. The items included in mechanical QA sheet were 1) gantry rotation, 2) collimator rotation, 3) couch rotation, 4) optical distance indicator (ODI), and 5) laser alignment. We compared new prototype sheet with conventional sheet for several hospitals in Korea for those items. The QA acceptance criteria in this study mainly followed published recommendations. The contents of test for mechanical QA are the following. Confirm that the digital and/or mechanical gantry angle readouts are correct. Verify that digital and/or mechanical readouts of collimator angle agree with the true angle, as determined with the protractor. Measure the light field using a graph paper and compare with the digital readouts. Confirm digital readout accuracy. Verify that the sagittal laser, the left and right lasers, and the ceiling laser intersect at the isocenter. In the design of new QA sheet, we emphasized the representation of the long-term stability of mechanical QA by using Excel program. By using the new prototype QA sheet, we simplified and visualized the mechanical QA process, and could estimate the long-term stability of mechanical error of linear accelerator.

  • PDF

Association between physical activity measured using an accelerometer and arterial stiffness based on pulse wave velocity and ankle-brachial index in healthy adults (건강한 성인에서 가속도계로 측정한 신체활동과 맥파전달속도 및 상완-발목 간 혈압비에 기반한 동맥경화지표와의 관계)

  • Lee, Hyunju;Park, Kye Wol;Jun, Ha Yeon;Gwak, Ji Yeon;Kim, Eun Kyung
    • Journal of Nutrition and Health
    • /
    • v.55 no.4
    • /
    • pp.506-520
    • /
    • 2022
  • Purpose: Physical activity (PA) has a beneficial effect on the prevention of arteriosclerosis in healthy adults. The purpose of this study was to analyze the relationship between PA measured using an accelerometer and arterial stiffness in healthy Korean adults. Methods: This study involved 87 subjects (36.8% women) aged 20-64 years. PA was evaluated using an accelerometer (wGT3X-BT, ActiGraph, Florida, USA) for 7 days. Based on the results of the accelerometer measurement, subjects were classified into active and inactive groups according to the World Health Organization (WHO) PA guidelines. The brachial-ankle pulse wave velocity (baPWV) and ankle-brachial index (ABI) to assess arterial stiffness were measured by a non-invasive vascular screening device (VP-1000 Plus, Omron). Results: The average age of the study subjects was 47.7 ± 11.3 years and the WHO PA guideline achievement rate was 29.9%. There was no significant difference in arterial stiffness (baPWV and ABI) between the active and inactive groups. In females, the time spent in light PA were positively correlated with ABI (r = 0.396; p < 0.05) and the number of sedentary bouts over 50 minutes was inversely correlated with ABI (r = -0.402; p < 0.05). However, there was no significant correlation between PA and arterial stiffness in males. Conclusions: The results of this study suggest that light PA and sedentary behavior have a positive correlation with arterial stiffness in females.