• 제목/요약/키워드: light curing

검색결과 464건 처리시간 0.026초

소설에 나타난 안방의 의미와 용도에 관한 연구 (A Study on 'An-Band' It's Meaning and Practical Use Mentioned in Novel)

  • 오혜경;김대년;서귀숙;신화경;최경실
    • 한국실내디자인학회논문집
    • /
    • 제18호
    • /
    • pp.81-86
    • /
    • 1999
  • The purpose of this study is to find out to meaning and practical use of 'Anbang' of which unique roles and function has not been changed till now since Chosun dynasty. The Study has been carried out by selecting 27 novels in which the word 'Anbang' mentioned frequently and analyzing the sentences with 'Anbang' . The major finding were summarized as follows: 1. Since Chosun dynasty till now, 'Anbang' in most important space for Korean in residential area its meaning and practical use had not been changed. 2. The meaning of Anbang could be categorized into two parts; One was general symbolic meaning which was perceived mentally in general and the other was specific symbolic meaning which was varied by uses. In case of general symbolic meaning 'Anbang' implied a space with light turned on late at night, a very special space from the point of interior decoration and size, a space to keep very important stuffs and a space to deal with very important business. In case of specific symbolic meaning during Chosun dynasty, 'Anbang' was used as a pronoun to imply a mistress as major occupant was a mistress. Since then, gradually, 'Anbang' was used as a pronoun to imply married couple as married couple becomes major occupant. 3. The practical use of 'Anbang' cold be categorized into two; One was routine usage and the other was exceptional usage. The typical routine use were sleeping, dining family gathering, visitor greeting, clothes changing and sewing. The exceptional use were a Sebae(new year's bow), Pyebaek(make a deep bow and offer her gifts to her parents-in-law) and patient curing.

  • PDF

Evaluation of accuracy of 3-dimensional printed dental models in reproducing intermaxillary relational measurements: Based on inter-operator differences

  • Choi, Won-joon;Lee, Su-jung;Moon, Cheol-Hyun
    • 대한치과교정학회지
    • /
    • 제52권1호
    • /
    • pp.20-28
    • /
    • 2022
  • Objective: Although, digital models have recently been used in orthodontic clinics, physical models are still needed for a multitude of reasons. The purpose of this study was to assess whether the printed models can replace the plaster models by evaluating their accuracy in reproducing intermaxillary relationships and by appraising the clinicians' ability to measure the printed models. Methods: Twenty sets of patients' plaster models with well-established occlusal relationships were selected. Models were scanned using an intraoral scanner (Trios 3, 3Shape Dental System) by a single operator. Printed models were made with ZMD-1000B light-curing resin using the stereolithography method 3-dimensional printer. Validity, reliability, and reproducibility were evaluated using measurements obtained by three operators. Results: In evaluation of validity, all items showed no significant differences between measurements taken from plaster and printed models. In evaluation for reliability, significant differences were found in the distance between the gingival zeniths of #23-#33 (DZL_3) for the plaster models and at #17-#43 (DZCM_1) for the printed models. In evaluation for reproducibility, the plaster models showed significant differences between operators at midline, and printed models showed significant differences at 7 measurements including #17-#47 (DZR_7). Conclusions: The validity and reliability of intermaxillary relationships as determined by the printed model were clinically acceptable, but the evaluation of reproducibility revealed significant inter-operator differences. To use printed models as substitutes for plaster models, additional studies on their accuracies in measuring intermaxillary relationship are required.

Comparison of Temperatures of the Resin Cement in Polycrystalline Ceramic Brackets Irradiated Using a Diode Laser

  • Son, Young-Tak;Son, KeunBaDa;Kim, Kyung-Min;Lee, Jae-Mok;Kim, Jin-Wook;Yu, Wonjae;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • 제14권2호
    • /
    • pp.69-78
    • /
    • 2021
  • Purpose: The primary objective of this study was to evaluate the change in the temperature of the adhesive resin in polycrystalline ceramic brackets irradiated using a diode laser at different irradiation energy levels and times. Materials and Methods: For the measurement of the temperature of the adhesive resin, it was applied at the base of the ceramic bracket, a thermocouple was placed at the center of the base surface, the bracket was placed on prepared resin specimens for light curing, and a laser was irradiated to the center of the bracket slot at 5, 7, and 10 W. For the measurement of the temperatures of the enamel under the bracket and pulp cavity, extracted premolar was fixed to a prepared mold and the ceramic bracket was bonded to the buccal surface of the premolar. The Kruskal-Wallis H test and Friedman test were used for statistical analysis. Result: At 5 W, the temperature of the adhesive resin did not reach the resin softening temperature of 200℃ within 30 seconds. At 7 W, it reached 200℃ when the ceramic bracket was irradiated continuously for 28 seconds. At 10 W, it reached 200℃ when the ceramic bracket was irradiated continuously for 15 seconds. During laser irradiation, the temperature of the enamel under the bracket increased by over 5℃ within 15 seconds. Conclusion: The use of diode laser irradiation for bracket debonding should be carefully considered because the pulp cavity temperature increases by over 5℃ within the irradiation time for resin thermal softening.

스핀 코팅을 이용한 용액 공정 방식의 컬러 코팅 기술 연구 (Research on color coating technology of solution process method using spin coating)

  • 임성민;안현식;최윤석
    • 전기전자학회논문지
    • /
    • 제27권1호
    • /
    • pp.78-84
    • /
    • 2023
  • 본 논문에서는 컬러 용액을 사용하여 스핀 코팅 방식으로 Building Integrated Photovoltaic(BIPV) 시스템용 전면 컬러 유리를 구현하였다. 컬러 유리 구현을 위해 진주광택 안료와 다양한 용액를 사용하여 컬러 용액에 적합한 용액을 조사하였다. 조사한 용액 중 자외선 광 경화제인 NOA series의 경우 다른 용액보다 우수한 코팅성과 컬러 재현성을 가진 컬러 유리를 구현할 수 있었다. NOA 65 기반의 컬러 용액으로 스핀 코팅하여 구현한 컬러 유리는 가시광선 및 근적외선 파장 대역에서 최대 86%의 높은 투과율을 보였으며 시간에 따른 컬러 유리의 광학적 특성의 변화가 미미하여 BIPV용 컬러 유리 구현을 위한 컬러 용액으로 적합하였다. 스핀 코팅 방식을 활용한 용액 공정 방식은 기존의 물리적 증착 방식이나 나노 입자를 활용한 컬러 유리 제작 공정보다 쉽고 빠르게 컬러 유리를 제작할 수 있어 BIPV용 전면 컬러 유리 제작 공정이 용이해질 것으로 기대된다.

Comparison between a bulk-fill resin-based composite and three luting materials on the cementation of fiberglass-reinforced posts

  • Carlos Alberto Kenji Shimokawa ;Paula Mendes Acatauassu Carneiro ;Tamile Rocha da Silva Lobo;Roberto Ruggiero Braga ;Miriam Lacalle Turbino;Adriana Bona Matos
    • Restorative Dentistry and Endodontics
    • /
    • 제48권3호
    • /
    • pp.30.1-30.11
    • /
    • 2023
  • Objectives: This study verified the possibility of cementing fiberglass-reinforced posts using a flowable bulk-fill composite (BF), comparing its push-out bond strength and microhardness with these properties of 3 luting materials. Materials and Methods: Sixty endodontically treated bovine roots were used. Posts were cemented using conventional dual-cured cement (CC); self-adhesive cement (SA); dual-cured composite (RC); and BF. Push-out bond strength (n = 10) and microhardness (n = 5) tests were performed after 1 week and 4 months of storage. Two-way repeated measures analysis of variance (ANOVA), 1-way ANOVA, t-test, and Tukey post-hoc tests were applied for the push-out bond strength and microhardness results; and Pearson correlation test was applied to verify the correlation between push-out bond strength and microhardness results (α = 0.05). Results: BF presented higher push-out bond strength than CC and SA in the cervical third before aging (p < 0.01). No differences were found between push-out bond strength before and after aging for all the luting materials (p = 0.84). Regarding hardness, only SA presented higher values measured before than after aging (p < 0.01). RC and BF did not present 80% of the maximum hardness at the apical regions. A strong positive correlation was found between the luting materials' push-out bond strength and microhardness (p < 0.01, R2 = 0.7912). Conclusions: The BF presented comparable or higher push-out bond strength and microhardness than the luting materials, which indicates that it could be used for cementing resin posts in situations where adequate light curing is possible.

세척 용액 및 세척 방법이 3D 프린팅 임시수복용 레진의 굴곡강도에 미치는 영향 (Effect of Washing Solvent and Washing Method on Flexural Strength of 3D-Printed Temporary Resin Material)

  • 김해봄;최재원
    • 한국산업융합학회 논문집
    • /
    • 제27권2_2호
    • /
    • pp.389-395
    • /
    • 2024
  • The purpose of this study was to evaluate the effect of different washing solvents and washing methods on the flexural strength of 3D printed temporary resin. A bar(25 × 2 × 2 mm) was produced with a layer thickness of 50 ㎛ using an LCD-type 3D printer and divided into 15 groups(n = 10, each) according to washing solution(IPA; 99% isopropyl alcohol, TPM; 93% Tripropylene glycol monomethylether, ETL; Ethanol, TWC; Twin 3D Cleaner, and DNC; DIO navi Cleaner) and washing method(Dip; Dip washing, Ultra; Ultrasonic washing, and Auto; Automated washing). All groups were washed for 5 minutes, and post-cured for 5 minutes using a UV LED light curing machine. The Flexural strength was measured using a three-point bending test using a universal testing machine. For statistical analysis, one-way ANOVA, Tukey HSD post hoc test, Kruskal-Wallis test and post-hoc by Bonferroni-Dunn test(𝛼=.05) were performed depending on whether the normality test was satisfied. In all washing solvents except TPM and DNC, the Dip group showed the lowest flexural strength values, while the Auto group showed the highest flexural strength values except for DNC. Additionally, the washing solution showed completely different flexural strength values depending on the washing method.

상아질 접착제에 포함된 활성제의 사용 유무가 자가중합 복합레진의 상아질에 대한 전단결합강도에 미치는 영향 (Effects of activators contained in adhesives on dentin bond strengths)

  • 강혜경;신주희;서규원;류재준
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.511-519
    • /
    • 2008
  • 연구목적: 본 연구의 목적은 자가중합 또는 이중중합을 위한 활성제가 포함된 상아질 접착제에서 활성제의 사용 유무가 자가중합 복합레진과 상아질 접착제간의 전단결합강도에 미치는 영향을 평가하는 것이다. 연구 재료 및 방법: 실험을 위하여 우식 및 충전물이 없는 건전한 대구치 50개를 주문제작한 아크릴릭 레진블록에 포매한 후, 모델 트리머로 연마하여 평활한 상아질면을 만든 후, 600grit 실리콘 카바이드 페이퍼로 연마하고 증류수에 보관하였다. 50개의 시편을 10개씩 5개 군으로 나눈 후, 상아질 접착제를 제조사의 지시대로 도포한 후, 플라스틱 주형을 이용하여 자가중합 복합레진 (Luxacore)을 접착시켰다. 상아질 접착제는 One-Step (OS군), Prime&Bond NT, AdheSE를 이용하였는데 Prime&Bond NT와 AdheSE는 단독으로 사용한 군 (PB군, AS군)과 활성제를 같이 사용한 군 (PBA군, ASA군)으로 다시 나누었다. 증류수에 24시간 보관 후, 인스트론 만능시험기를 사용하여 시편에 1 mm/min의 전단속도로 하중을 가하여 시편이 분리되는 최대 하중을 측정한 뒤, 단위 면적 당 결합강도 (MPa)로 환산하여 One-way ANOVA를 이용하여 비교, 분석하고 5% 유의수준에서 Tukey HSD 검정을 이용하여 분석하였다. 결과: 각 군의 전단결합강도의 평균을 보면, OS군이 18.6 MPa로 가장 높았고 그 다음이 PBA군 (10.3 MPa)과 ASA군 (10.2 MPa)이었고, PB군과 AS군이 각각 5.9 MPa, 6.0 MPa로 가장 낮은 전단결합강도를 나타내었다. 결론: 본 실험을 통해 Prime&Bond NT와 AdheSE에서 활성제를 같이 사용한 경우, 활성제를 사용하지 않은 경우보다 전단결합강도가 높아짐을 알 수 있었지만, 활성제가 포함되어 있지 않은 One-Step보다는 낮은 수치였다.

두께에 따른 이중 중합형 복합레진의 중합 (Polymerization of dual cured composites by different thickness)

  • 김윤주;진명욱;김성교;권태엽;김영경
    • Restorative Dentistry and Endodontics
    • /
    • 제33권3호
    • /
    • pp.169-176
    • /
    • 2008
  • 본 연구는 이중 중합형 복합레진에서 재료의 두께, 충전방법 및 중합방법에 따른 중합도를 미세경도 시험을 이용하여 측정하고자 하였다. 이중 중합형 복합레진으로는 MultiCore Flow (Ivovlar Vivadent AG, Schaan, Liechtenstein)와 Bis-Core (Bisco Inc., Schaumburg IL, USA)를 사용하였다. 시편의 제작은 각각 두께가 2(단일충전), 4 (단일충전), 6 (단일충전과 적층충전), 8 (단일충전과 적층충전) ㎜의 Teflon mold에 재료를 주입한 다음 할로겐 광중합기 (Optilux 501, Kerr, Danbury, USA)를 사용하여 광중합하거나 암실에서 30분 동안 기다린 후(자가 중합) Teflon mold에서 제거하였다. 제거한 시편은 $37{\circ}C$ 증류수에 24시간 동안 보관한 후 각 시편의 윗면과 아랫면을 2000번 연마제와 PoGo system (Dentsply, Konstanz, Germany)을 이용하여 마무리하였다. Digital microhardness tester (FM-7, Future-Tech Corp., Tokyo, Japan)를 이용하여 경도값(Knoop hardness number)을 측정하였으며 윗면의 경도값/아랫면의 경도값을 이용하여 경도비를 계산하였다. 계측치는 one-way ANOVA로 통계 분석 후 사후검정은 Scheffe 다중비교법을 이용하였다. 이중 중합형 복합레진의 중합도에 대한 두께의 영향을 보면 재료에 따라 다른 결과를 보였다. 2, 4, 6 mm 군에서는 MulriCore Flow와 Bis-Core 모두 두께에 의한 영향을 받지 않았지만 8 mm 군에서는 MultiCore Flow의 아랫면에서 다른 두께의 군보다 낮은 경도값을 보였다. 충전방법에 따른 중합도의 차이를 보면, 재료의 두께나 재료에 따라 다른 결과를 보였다. 6 mm 군에서는 단일충전군과 적층충전군 사이에 차이를 보이지 않았으나, 8 mm 군에서는 Bis-Core에서는 차이가 없는 반면 MultiCore Flow에서는 단일충전한 군이 적층중전한 군보다 낮은 경도비를 보였다. 중합방법에 따른 중합도의 차이를 보면, 재료에 따라 다른 결과를 보였다. Bis-Core의 경우에는 윗면과 아랫면 모두에서 이중 중합 시킨 군이 자가 중합 시킨 군보다 높은 경도값을 보였다. 그러나 MultiCore Flow의 경우, 윗면에서는 이중중합 시킨 군이 더 높은 경도값을 보였지만 아랫면에서는 더 낮은 값을 보였다. 따라서 본 연구의 결과에 따르면 코어용 이중 중합형 복합레진을 깊은 와동에 충전할 경우 적층충전이 추천되며, 또한 광중합을 해 줌으로써 더 좋은 물리적 성질을 기대할 수 있을 것으로 사료된다.

두께에 따른 이중 중합형 복합레진의 중합 (Polymerization of dual cured composites by different thickness)

  • 김윤주;진명욱;김성교;권태엽;김영경
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2008년도 Spring Scientific Meeting(the 129th) of Korean Academy if Conservative Dentistry
    • /
    • pp.169-176
    • /
    • 2008
  • 본 연구는 이중 중합형 복합레진에서 재료의 두께, 충전방법 및 중합방법에 따른 중합도를 미세경도 시험을 이용하여 측정하고자 하였다. 이중 중합형 복합레진으로는 MultiCore Flow (Ivovlar Vivadent AG, Schaan, Liechtenstein)와 Bis-Core (Bisco Inc. Schaumburg IL, USA)를 사용하였다. 시편의 제작은 각각 두께가 2 (단일충전). 4 (단일충전), 6 (단일충전과 적층충전), 8 (단일충전과 적층충전) mm의 Teflon mold에 재료를 주입한 다음 할로겐 광중합기 (Optilux 501 Kerr, Danbury, USA)를 사용하여 광중합하거나 암실에서 30분 동안 기다린 후(자가 중합) Teflon mold에서 제거하였다. 제거한 시편은 $37^{\circ}C$ 증류수에 24시간 동안 보관한 후 각 시편의 윗면과 아랫면을 2000번 연마제와 PoGo system (Dentsply, Konstanz, Germany)을 이용하여 마무리하였다. Digital microhardness tester (FM-7, Future-Tech Corp., Tokyo, Japan)를 이용하여 경도값(Knoop hardness number)을 측정하였으며 윗면의 경도값/아랫면의 경도값을 이용하여 경도비를 계산하였다. 계측치는 one-way ANOVA로 통계 분석 후 사후검정은 Scheffe 다중비교법을 이용하였다. 이중 중합형 복합레진의 중합도에 대한 두께의 영향을 보면 재료에 따라 다른 결과를 보였다. 2, 4, 6 mm군에서는 MultiCore Flow와 Bis-Core 모두 두께에 의한 영향을 받지 않았지만 8 mm 군에서는 MultiCore Flow의 아랫면에서 다른 두께의 군보다 낮은 경도값을 보였다. 충전방법에 따른 중합도의 차이를 보면 재료의 두께나 재료에 따라 다른 결과를 보였다. 6 mm 군에서는 단일충전군과 적층충전군 사이에 차이를 보이지 않았으나, 8 mm 군에서는 Bis-Core에서는 차이가 없는 반면 MultiCore Flow에서는 단일충전한 군이 적층충전한 군보다 낮은 경도비를 보였다. 중합방법에 따른 중합도의 차이를 보면, 재료에 따라 다른 결과를 보였다. Bis-Core의 경우에는 윗면과 아랫면 모두에서 이중 중합 시킨군이 자가 중합시킨 군보다 높은 경도값을 보였다. 그러나 MultiCore Flow의 경우, 윗면에서는 이중중합 시킨 군이 더 높은 경도값을 보였지만 아랫면에서는 더 낮은 값을 보였다. 따라서 본 연구의 결과에 따르면 코어용 이중 중합형 복합레진을 깊은 와동에 충전할 경우 적층충전이 추천되며, 또한 광중합을 해줌으로써 더 좋은 물리적 성질을 기대할 수 있을 것으로 사료된다.

  • PDF

Streptococcus mutans에 대한 클로르헥시딘과 Erythrosine 광역동 치료의 상승효과 (Enhancement of Erythrosine Photodynamic Therapy against Streptococcus mutans by Chlorhexidine)

  • 박종철;박호원;이시영
    • 대한소아치과학회지
    • /
    • 제40권4호
    • /
    • pp.241-246
    • /
    • 2013
  • 이 연구의 목적은 치과 임상에서 널리 사용되는 항미생물제제인 클로르헥시딘과 할로겐을 이용한 erythrosine 광역동 치료를 병용하였을 때, 부유 상태의 Streptococcus mutans에 미치는 항균효과를 평가하기 위함이다. S. mutans 표준 균주를 Brain Heart Infusion broth medium에 첨가하여 부유 상태로 배양하였다. 치과용 할로겐 광중합 장치를 광원으로 사용하였으며 치태 착색제인 erythrosine을 광감각제로 사용하였다. 클로르헥시딘의 최소살균농도를 측정하고, erythrosine 광역동 치료에서 최소살균농도를 결정하기 위해 $1{\mu}M$, $5{\mu}M$, $10{\mu}M$의 erythrosine 농도를 사용하여 할로겐 광중합기로 15초 동안 광조사를 시행한 후 세균수를 측정하였다. 마지막으로 클로르헥시딘과 erythrosine 광역동 치료를 병용한 경우 나타나는 상승효과를 평가하기 위해, 최소살균농도 이하인 0.001% 클로르헥시딘과 최소살균농도 이하인 $1{\mu}M$ erythrosine 광역동 치료를 병용하여 항균효과를 비교하였다. 최소살균농도 이하의 클로르헥시딘만 단독으로 사용하는 경우 S. mutans의 세균수가 유의하게 감소하지 않았다(p < 0.05). 또한 erythrosine 광역동 치료만 단독으로 시행한 경우에는 $5{\mu}M$, $10{\mu}M$의 erythrosine 농도에서 유의하게 세균수가 감소하였지만, $1{\mu}M$ erythrosine 농도에서는 세균수가 유의하게 감소하지 않았다(p < 0.05). 마지막으로 두 가지 치료법의 상승효과를 평가하기 위해 최소살균농도 이하인 $1{\mu}M$ erythrosine 광역동 치료와 0.001% 클로르헥시딘을 병용하는 경우에는, 대조군과 비교하여 세균수가 유의하게 감소하였다(p < 0.05). 최소살균농도 이하인 0.001% 클로르헥시딘과 $1{\mu}M$ erythrosine 광역동 치료를 각각 단독으로 시행하는 경우에는 유의한 항균효과가 없었지만, 두 가지 치료를 병용하는 경우 61%의 S. mutans 세균수가 감소하였다. 이상의 결과를 종합해 볼때 S. mutans에 대해 최소살균농도 이하의 클로르헥시딘과 erythrosine 광역동 치료를 병용하는 경우 상승효과가 있음을 알 수 있다.