• Title/Summary/Keyword: lens magnification

Search Result 71, Processing Time 0.023 seconds

Statistical Analysis of Focus Adjustment Method for a Floating Imaging System with Symmetric Error Factors (대칭형 공차를 갖는 플로팅 광학계의 상면 변화 보정 방법에 대한 통계적 해석)

  • Ryu, Jae Myung;Kim, Yong Su;Jo, Jae Heung;Kang, Geon Mo;Lee, Hae Jin;Lee, Hyuck Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.5
    • /
    • pp.189-196
    • /
    • 2012
  • A floating optical system is a system that moves more than 2 groups to focus at the camera lens. At the camera optics, the floating system that is mainly used is an optical system such as a macro lens which changes magnification very much. When the floating system is assembled and fabricated in the factory, there are differences between the image plane of the sensor and the focal plane of the infinity or macro state. Therefore, in a considerable proportion of cases, the focus adjustment to minimize the difference of BWD(Back Working Distance) is carried out in the process of manufacturing. In this paper, in order to decide the movement of each group in a floating system, we evaluated the rotation angle of CAM for the focus adjustment. We know that the maximum magnification of macro state is corrected by this numerical method for the focus adjustment, too. We investigated the limit of CAM rotation angle of the system by using statistical analysis for CAM rotation angle, which uses the focus adjustment of the floating system with symmetric error factors.

Performance Analysis of CPV Modules for Optimizing Secondary Optical Elements (CPV모듈의 2차 광학계 특성에 따른 성능분석)

  • Park, Jeom-Ju;Jeong, Byeong-Ho;Park, Ju-Hoon;Lee, Kang-Yeon;Kim, Hyo-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.5
    • /
    • pp.23-34
    • /
    • 2020
  • Concentrator photovoltaic (CPV) system consists of high-quality complex optical elements, mechanical devices, and electronics components and can have the advantages of high integration and high-efficiency energy sources. III-V compound semiconductor cells have proven performance based on high reliability in the aerospace field, but have characteristics that require absolute support of the balance of systems (BOS) such as solar position trackers, receivers with heat sinks, and housing instruments. To determine the optimum parameters of secondary optical elements (SOEs) design for CPV systems, we designed three types of CPV modules, classified as non-SOEs type, reflective mirror type, and CPC lens type. We measured the I-V and P-V characteristics of the prototype CPV modules with the angle of inclination varying from 0° to 12° and with a 500-magnification Fresnel lens. The experimental results assumed misalignment of the solar position tracker or module design of pinpoint accuracy. As a result, at the 0° tilt angle, the CPC lens produced lower power due to the quartz transmittance ratio compared to that by other SOEs. However, for tilt angles greater than 3°, the CPC lens type module achieved high efficiency and stability. This study is expected to help design high-performance CPV systems.

PLANETARY CAUSTIC PERTURBATIONS OF A CLOSE-SEPARATION PLANET ON MICROLENSING

  • Ryu, Yoon-Hyun;Kim, Han-Seek;Chung, Sun-Ju;Kim, Dong-Jin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.77.1-77.1
    • /
    • 2016
  • We investigate the properties and detection conditions for the planetary caustic perturbation of close-separation planets. To find the properties of the planetary caustic perturbation, we construct deviation maps by subtracting the single-lensing magnification of the lens star from the planetary lensing magnification for various lensing parameters. We find that each deviation area of the positive and negative perturbations disappears at the same normalized source radius according to a given deviation threshold regardless of mass ratio but disappears at a different normalized source radius according to the separation. We also estimate the upper limit of the normalized source radius to detect the planetary caustic perturbation. We find simple relations between the upper limit of the normalized source radius and the lensing parameters. From the relations, we obtain an analytic condition for the detection limit of the planet, and which show that we can sufficiently discover a planet with the mass of sub-Earth for typical microlensing events. Therefore, we expect to add the number of low-mass planets in the next-generation microlensing experiments and conclude that our detection condition of the planet can be used as a important criteria for maximal planet detections considering the source type and the photometric accuracy.

  • PDF

Autofocusing Mechanism of a Triple-Magnification Infrared System (3중 배율 적외선 영상 장비의 자동 초점 조절 방안)

  • Jung, Hyojung;Jeong, Suseong;Yang, Yunseok;Lee, Yongchun;Han, Jeongsu
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.6
    • /
    • pp.314-320
    • /
    • 2020
  • The optics used in an infrared imaging system has a strong refractive-index change according to temperature, so an autofocus control function is essential for a military infrared imaging system with a wide operating-temperature range. In this study, we design a triple-magnification infrared imaging system, and to compensate for the change in refractive index according to temperature we measure the change in the lens focus according to temperature. The autofocus control function was implemented by using the measured movement amount, and we could obtain an image with satisfactory resolution performance over a wide range of operating temperatures.

Design of an Optical System for Iris Photographing (홍채 촬영용 광학계 설계)

  • Park, Seung-Hwan;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.39-44
    • /
    • 2009
  • Purpose: To design a mini optical system photographing the iris, which is used in the iridology. Methods: We designed a mini optical system photographing the iris by using the Sigma 2000 design program. Results: We designed a mini optical system photographing the iris, which is suitable in the CCD using a micro actuator for auto-focusing, of which characteristics have the TCL of 30 mm, a magnification of -0.65, about 8.0 mm distance from the 1st lens to the last lens, the max barrel diameter of 11 mm, and about 1 mm of the effective stop diameter. Also the resolution line width of this system is characterised by 92 lps/mm at the 30% MTF value criterion. Conclusions: By designing an optical system of which characteristics have the TCL of 30 mm, about 8.0 mm distance from the 1st lens to the last lens, the max barrel diameter of 11 mm, and the resolution line width of $5.4{\mu}m$ at the 30% MTF value criterion, we could miniaturize the iris photographing optical system.

  • PDF

A Study on Adaptable Non-contact Shape Inspection System (적응형 비접촉 형상 검사에 관한 연구)

  • Kang, Young-June;Park, Nak-Gyu;Lee, Dong-Hwan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.2
    • /
    • pp.74-80
    • /
    • 2005
  • A new dimension measuring method for the measurement of diameter of an object has been developed using laser triangulation. The 3D data of an object was calculated from the 2 dimensional image information obtained by the laser stripe using the laser triangulation. The system that use existing theory can measure the diameter of hole not only in a normal plane but also ill an incline plane. However, in the existing theory, since the lens with fixed feral length was used, the area of measurement was fixed. The simplest way to solve this problem is to change distance between a CCD camera and object. Other way is to use a zoom lens having variable focal length. In this paper, the zoom lens with variable focal length was used. Therefore, we ran experiment with magnification that is optimized according to size of object using zoom lens with variable focal length.

Fabrication of Microstructure Array using the Projection Microstereolithography System (전사방식 마이크로광조형을 이용한 배열 형태 미세 구조물 가공)

  • Choi, Jae-Won;Ha, Young-Myoung;Lee, Seok-Hee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.8 s.197
    • /
    • pp.138-143
    • /
    • 2007
  • Microstereolithography technology is similar to the conventional stereolithography process and enables to fabricate a complex 3D microstructure. This is divided into scanning and projection type according to aiming at precision and fabrication speed. The scanning MSL fabricates each layer using position control of laser spot on the resin surface, whereas the projection MSL fabricates one layer with one exposure using a mask. In the projection MSL, DMD used to generate dynamic pattern consists of $1024{\times}768$ micromirrors which have $13.68{\mu}m$ per side. The fabrication range and resolution are determined by the field of view of the DMD and the magnification of the projection lens. If using the projection lens with high power, very fine microstructures can be fabricated. In this paper, the projection MSL system adapted to a large surface for array-type fabrication is presented. This system covers the meso range, which is defined as the intermediate range between micro and macro, with a resolution of a few ${\mu}m$. The fabrication of array-type microstructures has been demonstrated to verify the performance of implemented system.

The Development of adaptive optical dimension measuring system (적응형 광학 치수 측정 장치 개발)

  • 윤경환;강영준;백성훈;강신재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.690-695
    • /
    • 2004
  • A new dimension measuring method for the measurement of diameter of an object has been developed using laser triangulation. The 3-D data of an object was calculated from the 2dimensional image information obtained by the laser stripe using the laser triangulation. The system can measure the diameter of hole not only in a normal plane but also in an incline plane. We can experiment with magnification that is optimized according to size of object using zoom lens. In this paper, the theoretical formula and calibration of the system were described. The measuring precision of the system was investigated by experiment.

  • PDF

A Development of Electron Optics System of Mini-Sized SEM (소형주사전자현미경용 전자공학계의 개발)

  • Park, Man-Jin;Kim, Il-Hae;Kim, Dong-Hwan;Jang, Dong-Young;Han, Dong-Chul
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.140-144
    • /
    • 2007
  • As an electron scanning microscopes has traditionally required a considerably large room equipped with several service and pipe lines due to its inherent size. As an alternative, a small sized SEM, simply called a mini-SEM, is introduced even if the performance in terms of magnification and resolution is a little inferior to a classical thermal SEM. However, the size and fabrication cost is dramatically reduced, dedicating to opening a new market. The optical system in the mini-SEM is redesigned and specimen stage is quitely reduced and vertical axis is excluded. The design tools and calibration techniques to develope the mini-SEM are introduced and its performance is verified through numerical analysis experiments.

An Accurate Calibration Technique for X ray Imaging System (X-선 영상 시스템의 정밀 캘리브레이션 기법)

  • Cho, Young-Bin;Gweon, Dae-Gab
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.3 s.96
    • /
    • pp.198-207
    • /
    • 1999
  • This paper presents an accurate algorithm for geometric calibration of X-ray imaging system. Calibration is a very important process for improving an imaging system performance. There has been a lot of previous works using linear camera modeling technique, where lens distortion is neglected and/or center of distortion is assumed to be known. Geometrical distortion of image intensifier, however, is very large and its center of distortion should be calculated. This paper presents a new calibration method to estimate the intensifier position and orientation, scale factor, distortion coefficient, magnification factor, and center of distortion using the least square method. We investigate the properties of the algorithm by computer simulation. Simulation results show that the parameters can be estimated accurately using the proposed algorithm.

  • PDF