• Title/Summary/Keyword: length measurement

Search Result 2,201, Processing Time 0.027 seconds

An Analysis on the Measurement and Factors of the Foot for Korean Female especially Focusing on the Patients of the Hallux Valgus (한국 성인여성 중 무지외반증으로 인한 발 변형환자의 수술 전·후 발부위 계측치 및 요인분석)

  • Kim, Hyesoo;Kim, Sonhee
    • Journal of Fashion Business
    • /
    • v.19 no.4
    • /
    • pp.200-212
    • /
    • 2015
  • In order to study the foot deformity hallux valgus, the rate of which is currently increasing, 235 patients who were diagnosed with hallux valgus and treated in an orthopedic hospital in Seoul had their feet calibrated before and after surgery using 3d radio-scans. Data from 209 cases was analyzed and scored numerically. We scored 10 items for length, 4 for width, 3 for angle, and 2 for height, for a total of 20 items. Each individual's feet showed great variation in most of the items and significant differences after surgery, especially in regards to length and height, which increased after surgery. Angle, width, and length of the distal parts of the toes decreased after surgery. Based on the results of our analysis, we conclude that surgery brings about significant changes in structure and measurement of feet. This research confirmed that there is significant variation in foot form and individual differences based on lesion size and location and, thus, it is difficult for hallux valgus patients to find ready-made shoes that fit them properly. Foot changes before and after operation for hallux valgus were analyzed and the results quantified; our results should be considered during product design by shoe companies whose target is adult women.

A study on foot measurement and adult women's shoe standard size. (발의 계측과 성인여자구두의 기본치수에 관한 연구 -경상도지역의 여대생을 중심으로-)

  • 김효은
    • Journal of the Korean Home Economics Association
    • /
    • v.24 no.3
    • /
    • pp.43-50
    • /
    • 1986
  • This study is toidentify what makes people uncomfortable when people wear new shoes and to gain fundamental data for establishing shoe sizes. Data materal from the 16 measurement investigation conducted on 796 college girl students shows the following. 1) More than 96% of the subjects have experienced footache when they wore new shoes. It is significant that 45.76% of the subjects answered shoe width, especially pump-lining part cause them to feel more pain in their feet than any other measurement elements. 2) According to multiple correlation analysis to know which parts of feet determine shoe size, both multiple correlation coefficient of feet length to other parts of foot and joint girth to other parts of foot show the highest of R=0.93. 3) According to the ANOVA-tested result of estimated function when both foot-length-joint girth and foot length-joint girth-foot width are independent variables in each case, the level of α〈0.001 is very significant. 4) The comparision between KS G3116 adult women's shoe size establishment table and my table in this study reveals that the cases of more increased joint girth measurements than standard joint girth measurements in KS G 3116 table are easy to find.

  • PDF

Optical-fiber Electronic Speckle Pattern Interferometry for Quantitative Measurement of Defects on Aluminum Liners in Composite Pressure Vessels

  • Kim, Seong Jong;Kang, Young June;Choi, Nak-Jung
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.50-56
    • /
    • 2013
  • Optical-fiber electronic speckle pattern interferometry (ESPI) is a non-contact, non-destructive examination technique with the advantages of rapid measurement, high accuracy, and full-field measurement. The optical-fiber ESPI system used in this study was compact and portable with the advantages of easy set-up and signal acquisition. By suitably configuring the optical-fiber ESPI system, producing an image signal in a charge-coupled device camera, and periodically modulating beam phases, we obtained phase information from the speckle pattern using a four-step phase shifting algorithm. Moreover, we compared the actual defect size with that of interference fringes which appeared on a screen after calculating the pixel value according to the distance between the object and the CCD camera. Conventional methods of measuring defects are time-consuming and resource-intensive because the estimated values are relative. However, our simple method could quantitatively estimate the defect length by carrying out numerical analysis for obtaining values on the X-axis in a line profile. The results showed reliable values for average error rates and a decrease in the error rate with increasing defect length or pressure.

An Analysis of the Body Measurement for Children′s Clothing Design (아동복 설계를 위한 신체계측분석 연구)

  • 윤정혜;조윤주;박정순
    • The Research Journal of the Costume Culture
    • /
    • v.3 no.2
    • /
    • pp.293-306
    • /
    • 1995
  • The purpose of this study is to analysis children's measurement and to provide the fundamental information for he clothing design which can reflect the characteristic of their bodies. An anthropometric database used for this study was the 1992 national anthropomatric survey of Koreans. The results obtained are as follows; (1) Children showed the significant difference of their growth in accordance with the increase of their ages. There were also the difference between body and girls. Height, length of items grew most promthy. For example; boys from 10 to 11 and girls from 10 to 11 again their height mostly. (2) In character of body proportion, significant difference were found in accordance with their ages and sex. However, in the items of height, length noticeable changes of proportion could not be found because there were hardly any actual difference of size means while girth items appeared differently. (3) There were significant factors from the result of factor analysis of body dimension. The fist factor ; grith, depth, breath. The second factor ; height, length. (4) We can class three groups with the results of cluster analysis of body dimension.

  • PDF

Experimental Study on Micro PIV Measurement using a Micro Liquid Lens (마이크로 유체렌즈를 이용한 마이크로 PIV 측정에 관한 실험적 연구)

  • Jeong, S.R.;Dang, T.D.;Choi, J.H.;Kim, G.M.;Park, C.W.
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.3
    • /
    • pp.22-28
    • /
    • 2010
  • In the present study, we performed the velocity field measurement in a microchannel using a focal length variable micro liquid lens. The liquid lens is used as a beam expander in a micro-PIV system to acquire the scatter image of the seeded particle. A thin film-type micro liquid lens was made of PDMS material and it was attached on top of the 700-micron-wide working fluid supply channel trench. As a result, the focal length and contact angle of the liquid lens changed with variations in applied pressure.

J-R Curve Evaluation According to the Crack Length Measurement Techniques Under Reverse Cyclic Loading (역사이클하중하에서의 균열길이 측정법에 따른 파괴저항곡선의 평가)

  • 원종일;우흥식;석창성
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.96-101
    • /
    • 1998
  • J-R curve tests were performed on 1T compact specimens of SA516 Gr. 70 carbon steels under reverse cyclic loading. A Direct-Current Potential Drop (DCPD) method, one of the nondestructive techniques to detect flaw of structure, is being increasingly used for monitoring crack initiation and stable crack growth in typical fracture mechanics specimens for J-R testing. In many aspects this method is simpler than the unloading compliance method. The objective of this paper is to evaluate the J-R Curve according to the crack length measurement techniques under reverse cyclic loading. In order to prove the reliability and repeatability of the DCPD method, the crack length measured by using DCPD method was compared to one determined from unloading compliance. Consequently, this DCPD method correlated well with J-R curves and crack extension measurements determined from unloading compliance method.

  • PDF

Spray characteristics of swirl injector using liquid film thickness measurement (액막두께 측정방법을 이용한 스월 인젝터의 분무특성 연구)

  • Kim Sung-Hyuk;Kim Dong-Jun;Kim Byung-Sun;Yoon Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.251-255
    • /
    • 2005
  • By using liquid film thickness measurement the spray characteristics of swirl injector according to the geometric parameters were investigated in this paper. A specially designed injector having a variable backhole length, swirl chamber length, orifice length was used to measure the liquid film thickness. The spray characteristics of the injector were represented by mass flow rate according to the injection pressure, liquid film thickness in the lower orifice, spray cone angle.

  • PDF

Study on Image Processing Technique for Inspection of Injected E.V.A Midsole (Injected E.V.A Midsole의 검사를 위한 영상처리 기술에 관한 연구)

  • 강인혁;조연상;박흥식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.269-272
    • /
    • 1997
  • It is need to inspect a injected E.V.A midsole automatically in shoe manufacture. We applied image processing technology to inspect a injected E.V.A midsole. Captured image by CCD camera was processed with smoothing and edge detection. We compensated error of length from processed image of gauge block and error by bending strain with the measurement method of interval length for midsole image.

  • PDF

Measurement of Surface Crack Length Using Image Processing Technology (영상처리기법을 이용한 표면균열길이 측정)

  • Nahm, Seung-Hoon;Kim, Yong-Il;Kim, Si-Cheon;Ryu, Dae-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.96-101
    • /
    • 2001
  • The development of a new experimental method is required to easily observe the growth behavior of fatigue cracks. To satisfy the requirement, an image processing technique was introduced to fatigue testing. The length of surface fatigue crack could be successfully measured by the image processing system. At first, the image data of cracks were stored into the computer while the cyclic loading was interrupted. After testing, crack length was determined using image processing software which was developed by ourselves. Block matching method was applied to the detection of surface fatigue cracks. By comparing the data measured by image processing system with the data measured by manual measurement with a microscope, the effectiveness of the image processing system was established. If the proposed method is used to monitor and observe the crack growth behavior automatically, the time and efforts for fatigue test could be dramatically reduced.

  • PDF

Hot-carrier Induced MOSFET Degradation and its Lifetime Measurement (Hot-carrier 효과로 인한 MOSFET의 성능저하 및 동작수명 측정)

  • 김천수;김광수;김여환;김보우;이진효
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.2
    • /
    • pp.182-187
    • /
    • 1988
  • Hot carrier induced device degradation characteristics under DC bias stress have been investigated in n-MOSFETs with channel length of 1.2,1.8 um, and compared with those of LDD structure device with same channel length. Based on these results, the device lifetime in normal operating bias(Vgs=Vds=5V) is evaluated. The lifetimes of conventional and LDD n-MOSFET with channel length of 1.2 um are estimated about for 17 days and for 12 years, respectively. The degradation rate of LDD n-MOSFET under the same stress is the lowest at n-region implnatation dose of 2.5E15 cm-\ulcorner while the substrate current is the lowest at the dose of 1E13cm-\ulcorner Thses results show that the device degradation characteristics are basic measurement parameter to find optimum process conditions in LDD devices and evaluate a reliability of sub-micron device.

  • PDF