• Title/Summary/Keyword: length measurement

Search Result 2,195, Processing Time 0.027 seconds

Measurement of Porcine Aortic and Pulmonary Valve Geometry and Design for Implantable Tissue Valve (돼지 대동맥, 폐동맥의 근위부 기하학적 구조 측정을 통한 판막 구조 수치의 계량화와 판막 도안에 관한 연구)

  • Park, Sung-Joon;Kim, Yong-Jin;Nam, Jin-Hae;Kim, Soo-Hwan;Lee, Chang-Ha;Lim, Hong-Gook
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.602-613
    • /
    • 2010
  • Background: As life expectancy has been increased, the cardiac valve disease has been increased. In past, mechanical valve for valve replacement surgery was used widely, but it has many weaknesses, such as hemorrhage, teratogenic effect caused by warfarin, acute mechanical failure, taking warfarin during life, etc. So, the tissue valve is used widely and researches for durability of tissue valve are in progress. Tissue valves being used are all imported in Korea, and there is a lack of information on its geometry and design. So, we studied the geometry of porcine aortic and pulmonary valve, and tried to suggest theoretical basis for making the aortic and pulmonary valve. Material and Method: We harvested aortic and pulmonary valves of 25 pigs and measured the geometry of valve at fresh and glutaraldehyde (GA) fixed state. In each group, we measured the diameter of the base, diameter of commissure, valve height, commissural height, etc. Also, for making implantable porcine and bovine pericardial valve, we designed the valve stent form, thickness, height, and leaflet size, form, thickness by different size of valve. Result: The aortic and pulmonary valve geometry and ratio were measured in each group. The right coronary cusp of aortic valve and right facing cusp of pulmonary valve was bigger than other cusps and non coronary cusp was smaller than others (RCC: NCC : LCC=1 : 0.88 : 1). Valve height was correlated to the leaflet size. We designed the outer diameter of stented porcine aortic valve from 19 mm to 33 mm and designed stent height and width, using previous measured ratio of each structure, stent thickness, working thickness (for making valve). Also, we designed the size of stent and form for stented bovine pericardial valve, considering diameter of valve, leaflet length, height and leaflet minimum coaptation area. Conclusion: By measuring of 25 pig's aortic and pulmonary valve geometry and ratio, we can make theoretical basis for making implantable stented porcine valve and bovine pericardial valve in various size. After making implantable valve using these data, it is necessary to do in vivo and in vitro researches, furthermore.

A Comparison of pre and post-surgical characteristics in skeletal Class III malocclusion patients using counterpart analysis (구조적 대응체 분석법에 의한 골격성 II급 부정교합 환자의 악교정 수술전후의 비교)

  • Sohn, Byung-Wha;Kyung, Seung-Hyun;Kim, Beom-soo
    • The korean journal of orthodontics
    • /
    • v.34 no.1 s.102
    • /
    • pp.93-107
    • /
    • 2004
  • Enlow's counterpart analysis explains the complex with anatomic and developmental characteristics where craniofacial aspect of Individuals has been developed. Counterpart analysis does not compare individual measurement with the normal value from the average of majority but analyzes by comparison of values that each individual has. In this study we examined surgical changes in skeletal Class III malocclusion patients(male 40, female 40) and compared them with normal occlusion patients using counterpart analysis. The results indicated that : 1. Skeletal anterior-posterior discrepancy was relieved by shortening of the ramus width(B3). 2. The ramus alignment(R3, R4) was displaced posteriorly and the occlusal plane angle(R5) was rotated clockwise. 3. Skeletal Class III pattern was relieved in the post-operative group, but differences in the level of the cranium(R1, R2) was remaining compared to the normal occlusion patients. 4. In the comparison of surgery methods, the two-jaw surgery group presented changes In the maxillary length(A4), ramus alignment(R3, R4) and occlusal plane angle(R5) compared to the one-jaw surgery group, but the differences were not significant. In the past study about Korean skeletal Class m patients, the skeletal characteristics are upward backward rotation of the cranial base, posterior displacement of the maxilla, forward inclination of the ramus and lengthening of the mandibular body, but in this study, skeletal Class m pattern was relieved by shortening of the ramus width and maxillary advancement by orthognathic surgery, because orthognathic surgery is usually performed on limited areas in the maxilla and the mandible.

INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER (적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석)

  • Choi, Sung-A;Kim, Sun-Ho;Hwang, Yun-Chan;Youn, Chang;Oh, Byung-Ju;Choi, Bo-Young;Juhng, Woo-Nam;Jeong, Sun-Wa;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

Development and Performance Evaluation of an Animal SPECT System Using Philips ARGUS Gamma Camera and Pinhole Collimator (Philips ARGUS 감마카메라와 바늘구멍조준기를 이용한 소동물 SPECT 시스템의 개발 및 성능 평가)

  • Kim, Joong-Hyun;Lee, Jae-Sung;Kim, Jin-Su;Lee, Byeong-Il;Kim, Soo-Mee;Choung, In-Soon;Kim, Yu-Kyeong;Lee, Won-Woo;Kim, Sang-Eun;Chung, June-Key;Lee, Myung-Chul;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.445-455
    • /
    • 2005
  • Purpose: We developed an animal SPECT system using clinical Philips ARGUS scintillation camera and pinhole collimator with specially manufactured small apertures. In this study, we evaluated the physical characteristics of this system and biological feasibility for animal experiments. Materials and Methods: Rotating station for small animals using a step motor and operating software were developed. Pinhole inserts with small apertures (diameter of 0.5, 1.0, and 2.0 mm) were manufactured and physical parameters including planar spatial resolution and sensitivity and reconstructed resolution were measured for some apertures. In order to measure the size of the usable field of view according to the distance from the focal point, manufactured multiple line sources separated with the same distance were scanned and numbers of lines within the field of view were counted. Using a Tc-99m line source with 0.5 mm diameter and 12 mm length placed in the exact center of field of view, planar spatial resolution according to the distance was measured. Calibration factor to obtain FWHM values in 'mm' unit was calculated from the planar image of two separated line sources. Te-99m point source with i mm diameter was used for the measurement of system sensitivity. In addition, SPECT data of micro phantom with cold and hot line inserts and rat brain after intravenous injection of [I-123]FP-CIT were acquired and reconstructed using filtered back protection reconstruction algorithm for pinhole collimator. Results: Size of usable field of view was proportional to the distance from the focal point and their relationship could be fitted into a linear equation (y=1.4x+0.5, x: distance). System sensitivity and planar spatial resolution at 3 cm measured using 1.0 mm aperture was 71 cps/MBq and 1.24 mm, respectively. In the SPECT image of rat brain with [I-123]FP-CIT acquired using 1.0 mm aperture, the distribution of dopamine transporter in the striatum was well identified in each hemisphere. Conclusion: We verified that this new animal SPECT system with the Phlilps ARGUS scanner and small apertures had sufficient performance for small animal imaging.

Investigation of O4 Air Mass Factor Sensitivity to Aerosol Peak Height Using UV-VIS Hyperspectral Synthetic Radiance in Various Measurement Conditions (UV-VIS 초분광 위성센서 모의복사휘도를 활용한 다양한 관측환경에서의 에어로솔 유효고도에 대한 O4 대기질량인자 민감도 조사)

  • Choi, Wonei;Lee, Hanlim;Choi, Chuluong;Lee, Yangwon;Noh, Youngmin
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.2_1
    • /
    • pp.155-165
    • /
    • 2020
  • In this present study, the sensitivity of O4 Air Mass Factor (AMF) to Aerosol Peak Height (APH) has been investigated using radiative transfer model according to various parameters(wavelength (340 nm and 477 nm), aerosol type (smoke, dust, sulfate), aerosol optical depth (AOD), surface reflectance, solar zenith angle, and viewing zenith angle). In general, it was found that O4 AMF at 477 nm is more sensitive to APH than that at 340 nm and is stably retrieved with low spectral fitting error in Differential Optical Absorption Spectroscopy (DOAS) analysis. In high AOD condition, sensitivity of O4 AMF on APH tends to increase. O4 AMF at 340 nm decreased with increasing solar zenith angle. This dependency isthought to be induced by the decrease in length of the light path where O4 absorption occurs due to the shielding effect caused by Rayleigh and Mie scattering at high solar zenith angles above 40°. At 477 nm, as the solar zenith angle increased, multiple scattering caused by Rayleigh and Mie scattering partly leads to the increase of O4 AMF in nonlinear function. Based on synthetic radiance, APHs have been retrieved using O4 AMF. Additionally, the effect of AOD uncertainty on APH retrieval error has been investigated. Among three aerosol types, APH retrieval for sulfate type is found to have the largest APH retrieval error due to uncertainty of AOD. In the case of dust aerosol, it was found that the influence of AOD uncertainty is negligible. It indicates that aerosol types affect APH retrieval error since absorption scattering characteristics of each aerosol type are various.

Performance Evaluation of Fabric Sensors for Movement-monitoring Smart Clothing: Based on the Experiment on a Dummy (동작 모니터링 스마트 의류를 위한 직물 센서의 성능 평가: 더미 실험을 중심으로)

  • Cho, Hyun-Seung;Park, Sun-Hyeong;Kang, Da-Hye;Lee, Kang-Hwi;Kang, Seung-Jin;Han, Bo-Ram;Oh, Jung-Hoon;Lee, Hae-Dong;Lee, Joo-Hyeon;Lee, Jeong-Whan
    • Science of Emotion and Sensibility
    • /
    • v.18 no.4
    • /
    • pp.25-34
    • /
    • 2015
  • TThis study explored the requirement of fabric sensor that can measure the motion of the joint effectively by measuring and analyzing the variation in electric resistance of a sensor in accordance with bending and stretching motion of the arm by the implementation of a motion sensor utilizing conductive fabric. For this purpose, on both sides of two kinds of knitted fabric, namely 'L' fabric and 'W' fabric Single Wall Carbon Nano-Tube(SWCNT) was coated, fabric sensor was developed by finishing them in a variety of ways, and the sensor was attached to the arm band. The fabric sensor consisted of total 48 cases, namely background fabric for coating, the method of sensor attachment, the number of layer of sensors, the length of sensor, and the width of sensor. The performance of fabric motion sensors in terms of a dummy arm, that is, a Con-Trex MJ with 48 arm bands around it was evaluated. For each arm band, a total of 48, fastened around the dummy arm, it was adjusted to repeat the bending and stretching at the frequency : 0.5Hz, ROM : $20^{\circ}{\sim}120^{\circ}$, the voltage was recorded for each case after conducting three sets of repeat measurement for a total of 48 cases. As a result of the experiment, and as a consequences of the evaluation and analysis of the voltage based on the uniformity of the base line of the peak-to-peak voltage(Vp-p), the uniformity of Vp-p within the same set, and the uniformity of the Vp-p among three sets, the fabric sensors that have been configured in SWCNT coated 'L' fabric / welding / two layers / $50{\times}5mm$, $50{\times}10mm$, $100{\times}10mm$, and SWCNT coated 'W' fabric / welding / two layers / $50{\times}10mm$ exhibited the most uniform and stable signal value within 5% of the total variation rate. Through all these results of the experiment, it was confirmed that SWCNT coated fabric was suitable for a sensor that can measure the human limb operation when it was implemented as a fabric sensor in a variety of forms, and the optimal sensor types were identified.

A Study on the Equations of Estimating the Leaf Area of Broad-Leaf Species in Mt. Jiri (지리산(智異山) 주요(主要) 활엽수종(闊葉樹種)의 엽면적(葉面積) 추정식(推定式)에 대(對)한 연구(硏究))

  • Kim, Si Kyung;Lee, Kyeong Hack
    • Journal of Korean Society of Forest Science
    • /
    • v.70 no.1
    • /
    • pp.103-108
    • /
    • 1985
  • This paper is concerned with estimating equations of leaf area(A) obtained from linear measurements - leaf length(L) and leaf width(W) - on the leaves of 13 species composing a natural mixed stand in Mt. Jiri. This method is known to be rapid and non-destructive in estimating leaf area. The equation of A=bLW is frequently used in rough and rapid estimation. Each species in this study has its own coefficient b according to its geometrical leaf shape. The range of coefficients of 13 species was 0.579 to 0.717. This means that the relationship A=2/3LW is suitable to most broad leaf species in a natural mixed stand in Mt. Jiri. When more precise estimation of leaf area is needed, full regression equation is used. In this study, the form of ${\log}A=b_0+b_1{\log}LW$ was the most precise estimation equation in 8 species. In addition to this, the form of $A=b_0+b_1LW$ and $A=b_0+b_1L^2+b_2W^2$ were founded to be suitable for estimation of leaf area. In comparision of these two forms, the determination coefficient were about the same, but the F-value of the former was greater than that of the latter. Therefore, the use of the former seems to be more reliable and practical.

  • PDF

The Clinical Effect and Construction of a Stereotactic Whole Body Immobilization Device (전신 정위 고정장치 제작과 임상효과에 대한 연구)

  • 정진범;정원균;서태석;최경식;진호상;지영훈
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.30-38
    • /
    • 2004
  • Purpose: To develop a whole body frame for the purpose of reducing patient motion and minimizing setup error for extra-cranial stereotactic radiotherapy, and to evaluate the repositioning setup error of a patient in the frame. Materials and Methods: The developed whole body frame is composed of a base plate, immobilizer, vacuum cushion, ruler and belts. The dimension of the base plate is 130 cm in length, 50 cm in width and 1 cm in thickness. The material used in the base plate of the frame was bakelite and the immobilizer was made of acetal. In addition, Radiopaque angio-catheter wires were engraved on the base plate for a coordinate system to determine the target localization. The measurement for radiation transmission and target localization is peformed in order to test the utilization of the frame. Also, a Matlab program analyzed the patients setup error by using the patient's setup images obtained from a CCTV camera and digital record recorder (DVR). Results: A frame that is useful for CT simulation and radiation treatment was fabricated. The frame structure was designed to minimize collisions from the changes in the rotation angle of the gantry and to maximize the transmission rate of the Incident radiation at the lateral or posterior oblique direction. The lightening belts may be used for the further reduction of the patient motion, and the belts can be adjusted so that they are not in the way of beam direction. The radiation transmission rates of this frame were measured as 95% and 96% at 10 and 21 MV, respectively. The position of a test target on the skin of a volunteer is accurately determined by CT simulation using the coordinate system in the frame. The estimated setup errors by Matlab program are shown 3.69$\pm$1.60, 2.14$\pm$0.78 mm at the lateral and central chest, and 7.11 $\pm$2.10, 6.54$\pm$2.22 mm at lateral and central abdomen, respectively. The setup error due to the lateral motion of breast is shown as 6.33$\pm$ 1.55 mm. Conclusion: The development and test of a whole body frame has proven very useful and practical in the radiosurgery for extra-cranial cancers. It may be used in determining target localization, and it can be used as a patient immobilization tool. More experimental data should be obtained in order to improve and confirm the results of the patient setup error.

  • PDF

Expression of CsRCI2s by NaCl stress reduces water and sodium ion permeation through CsPIP2;1 in Camelina sativa L.

  • Kim, Hyun-Sung;Lim, Hyun-Gyu;Ahn, Sung-Ju
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.194-194
    • /
    • 2017
  • Camelina (Camelina sativa L.) is a potential bio-energy crop that has short life cycle about 90 days and contains high amount of unsaturated fatty acid which is adequate to bio-diesel production. Enhancing environmental stress tolerance is a main issue to increase not only crop productivity but also big mass production. CsRCI2s (Rare Cold Inducible 2) are cold and salt stress related protein that localized at plasma membrane (PM) and assume to be membrane potential regulation factor. These proteins can be divide into C-terminal tail (CsRCI2D/E/F/G) or no-tail group (CsRCI2A/B/C/H). However, function of CsRCI2s are less understood. In this study, physiological responses and functional characterization of CsRCI2s of Camelina under salt stress were analyzed. Full-length CsRCI2s (A/B/E/F) and CsPIP2;1 sequences were confirmed from Camelina genome browser. Physiological investigations were carried out using one- or four-week-old Camelina under NaCl stress with dose and time dependent manner. Transcriptional changes of CsRCI2A/B/E/F and CsPIP2;1 were determined using qRT-PCR in one-week-old Camelina seedlings treated with NaCl. Translational changes of CsRCI2E and CsPIP2;1 were confirmed with western-blot using the antibodies. Water transport activity and membrane potential measurement were observed by cRNA injected Xenopus laevis oocyte. As results, root growth rate and physiological parameters such as stomatal conductance, chlorophyll fluorescence, and electrolyte leakage showed significant inhibition in 100 and 150 mM NaCl. Transcriptional level of CsPIP2;1 did not changed but CsRCI2s were significantly increased by NaCl concentration, however, no-tail type CsRCI2A and CsRCI2B increased earlier than tail type CsRCI2E and CsRCI2F. Translational changes of CsPIP2;1 was constitutively maintained under NaCl stress. But, accumulation of CsRCI2E significantly increased by NaCl stress. CsPIP2;1 and CsRCI2A/B/E/F co-expressed Xenopus laevis oocyte showed decreased water transport activity as 61.84, 60.30, 62.91 and 76.51 % at CsRCI2A, CsRCI2B, CsRCI2E and CsRCI2F co-expression when compare with single expression of CsPIP2;1, respectively. Moreover, oocyte membrane potential was significantly hyperpolarized by co-expression of CsRCI2s. However, higher hyperpolarized level was observed in tail-type CsRCI2E and CsRCI2F than others, especially, CsRCI2E showed highest level. It means transport of $Na^+$ ion into cell is negatively regulated by expression of CsRCI2s, and, function of C-terminal tail is might be related with $Na^+$ ion influx. In conclusion, accumulation of NaCl-induced CsRCI2 proteins are related with $Na^+$ ion exclusion and prevent water loss by CsPIP2;1 under NaCl stress.

  • PDF

Studies on the Effect of Cation on the Activity at the 5th Instar Larvae of Bombyx mori (5령유충의 배맥관운동에 대한 양이온의 영향에 관한 연구)

  • 윤종관;사기언
    • Journal of Sericultural and Entomological Science
    • /
    • v.18 no.2
    • /
    • pp.89-93
    • /
    • 1976
  • The physiological saline solution for animals is known as Ringer's solution which is used for keeping the function of cold blooded vertebrate animals. Primaily the saline solution is used for the purpose of perfusion experiment in frogs. Later the saline solution is applied in several kinds of animals including human being with satisfactory results. However, this saline solution was introduced to silkworm and it was found that the result was not as successful as in the case of other animals and human being. Normally, in the case of silkworm, the physiological saline solution is prepared in order to maintain the normal function of separated organs and tissues. To this end, the saline solution is adjusted to contain the certain amount and strength of ions, osmosis pressure and hydrogen concentration. The most of cases, the physiological saline solution should be prepared so that the constituent of the solution be the same with the blood selium and body fluid. The hydrogen concentration in the ion element of the saline solution is adjustable by adding Na$\^$+/, K$\^$+/, Ca$\^$++/, Mg$\^$++/ which are followed by adding of buffer solution such as NaHCO$_3$and NaH$_2$PO$_4$. Determination of optimum concentration of cation in the physiological saline solution, and the optimum mixing rate of more than two kinds of cations are based on the movement of dorsal vessel in the silkworm larvae. The optimum concentration of cations in the solution is prepared by adding NaCl solution which is under zero point. However, this solution was further added with the different concentration of KCl and CaCl$_2$. By dropping the prepared solution on the 5th larvae, the effects of solution was measured. The measurement was done by observation of movement' of dorsal vessel and its time length, and the number of pulses. According to the experiment, it was found that when only NaCl solution was applied, the number of pulses is increased for a moment, and the pulse stopped after one hour or so. When KCl solution was added the time of pulse was prolonged and in the contrast, the number of pulses was slow down. If KCl and CaCl$_2$solutions are added the time of pulse was further prolonged. Even though the adding of KCl and CaCl$_2$are found to be effectible, the correlation between the concentration of solution and the movement of dorsal vessel was not observed. However, it was same in the case of adding Ca$\^$++/ or K$\^$+/. It was found that when Mg$\^$++/ was added to dorsal vessel the number of the pulses was not decreased although the prolonged time pulse was observed.

  • PDF