• Title/Summary/Keyword: length measurement

Search Result 2,207, Processing Time 0.027 seconds

150 nm Pitch Measurement using Metrological AFM (길이 소급성을 갖는 AFM을 이용한 150nm 피치 측정)

  • ;I. Misumi;S. Gonda;T. Kurosawa
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.264-267
    • /
    • 2003
  • Pitch measurements of 150 nm pitch one-dimensional grating standards were carried out using an contact mode atomic force microscopy(C-AFM) with a high resolution three-axis laser interferometer. It was called as 'Nano-metrological AFM' In Nano-metrological AFM, Three laser interferometers were aligned well to the end of AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$-stablilzed He-Ne laser at a wavelength of 633 nm. So, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM has a traceability to the length standard directly. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement(GUM). The Primary source of uncertainty in the pitch-measurements was derived from repeatability of pitch-measurement, and its value was approx 0.186 nm. Expanded uncertainty(k=2) of less than 5.23 nm was obtained. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

  • PDF

A Comparison of Accuracy Between a Turbine and an Orifice Meter in the Field (현장여건에 따른 터빈 유량계와 오리피스 유량계의 정확도 비교)

  • An, Seung-Hee;Her, Jae-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.97-105
    • /
    • 1999
  • Orifice flow meters are frequently used for measuring gas flow in gas industry. However, to insure the accuracy of the measurement, a certain length of the meter run at the upstream of the flow meter is required. The objective of this study is to analyze flow measurement errors of the orifice flow meter quantitatively for shorter lengths of the meter runs than those suggested in the standard manuals with variation of diameter ratio( $\beta$ ratio) and flow rate. The test results showed that the flow measurement errors of the orifice meter were inversely proportional to the diameter ratio. In other words, when the diameter ratio is 0.3 and 0.7, the measurement error is $-7.3\%$ and $-3.5\%$, respectively. the main reason of the measurement error is due to the swirl effect from the configuration of the meter run at the upstream of the flow meter. In case the length of the meter run is shorter than that suggested in the standard manuals, the swirl effect is not removed completely and it affects the flow meter's performance. As mentioned above, the less the pipe diameter ratio, the more the flow measurement error. It means that the swirl effect on the orifice meter increases as the $\beta$ ratio decreases.

  • PDF

The comparison of the basic human body measurement definitions and anthropometric terms between KS and ISO (인체 측정 방법 및 측정 항목에대한 KS와 ISO의 비교)

  • 이영숙;김동진;남경희;안병덕;이관석
    • Proceedings of the ESK Conference
    • /
    • 1997.04a
    • /
    • pp.247-255
    • /
    • 1997
  • In this study, the comparison of the basic human body measurement definitions and anthropometric terms between the Korean Standard and the International Standard. Measurement definitions, measurement method and measurement terms of the international standard ISO 8559, 7250 were compard with the KSRI-88-103-IR. We have tried to suggest the new methods and new terms such as eye height, waist height, arm length.

  • PDF

Survey on Setting New Standards for Estimation of Acupoints in the Upper Limb of Normal Adults (정상(正常) 성인(成人) 남녀(男女) 상지부위(上肢部位)의 실측(實測)을 통한 혈부위(穴部位) 도량형(度量衡)의 기준(基準) 정립(定立))

  • Sung, Byoung-Sik;Kwon, O-Sang;Jeon, In-Suk;Kim, Jae-Hyo;Ahn, Sung-Hun;Sohn, In-Chul
    • Korean Journal of Acupuncture
    • /
    • v.25 no.3
    • /
    • pp.1-14
    • /
    • 2008
  • Objectives : Weights and measures (度量衡) in Korean traditional medicine have been changed in many dynasties and countries. Thus, measurements of chon (寸) and cheok (尺) have been considered as symbolical meaning in recent studies on meridians and acupoints. The present study was made to settle up standard measurement by surveying length of each parts of upper limb as follows. Methods : To calculate length of 1 chon (寸), the length of each part was divided into the numbers of chon (寸) as shwon in ${\ll}$Goldo Hwangjenaegyeong-yeongchu (靈樞 骨度篇)${\gg}$; the chon (寸) length in ${\ll}$Goldo Hwangjenaegyeong-yeongchu (靈樞 骨度篇)${\gg}$ was compared with the chon (寸) length which is calculated by dividing human average hight into 75 chon. Results : Increment of length of 1 chon (寸) did not change as increment of height in subjects. Length of 1 chon (寸) in height is representative of length of 1 chon (寸) in each parts of upper limb. Conclusions : We suggest that most suitable length of 1 chon (寸)for the standard measurement of acupoint location is 2.20 ${\pm}$ 0.17 cm based on length of elbow joint to wrist joint.

  • PDF

An Analysis of Length and Time in the Elementary Mathematics Textbooks: Focused on the Instructional Components of Measurement and Key Competencies in Mathematics (길이와 시간에 관한 초등학교 수학 교과서 분석: 측정의 교수·학습 요소 및 수학 교과 역량을 중심으로)

  • Pang, JeongSuk;Kwon, MiSun;Kim, MinJeong;Choi, InYoung;SunWoo, Jin
    • School Mathematics
    • /
    • v.18 no.2
    • /
    • pp.301-322
    • /
    • 2016
  • Even though measurement is an important strand of elementary mathematics education, there has been lack of research in this field. This study analyzed topics related to length and time in a series of mathematics textbooks aligned to 2007 or 2009 revised mathematics curriculum. The analysis was focused on three aspects: (a) overall instructional components of measurement, (b) instructional components specific to the topics of measurement, and (c) key competencies in mathematics. The results of this study showed that many topics dealing with length and time were represented with relation to real-life contexts or other subjects. The meanings of measurement terms and the necessity of calculation were well explained but other aspects still had room for improvement when it comes to the necessity of measurement units, appropriate choice of units, and use of students' common misconceptions. Another noticeable result was that problem solving, communication, and reasoning among key competencies in mathematics have been emphasized in the mathematics textbooks. Based on these results, this study provides textbook writers with implications on what to further consider in dealing with length and time.

Identification of the Relationship between Surface Variations of Lower Body Parts by Movement Using 3D Scan Data - A Focus on Women Aged 20 to 24 Years - (3D 스캔데이터를 활용한 동작에 따른 하반신 주요 부위별 체표면 변화 및 상관관계 - 20-24세 여성을 중심으로 -)

  • Lee, So-Young;Kim, Ji Min
    • Journal of the Korean Society of Costume
    • /
    • v.67 no.3
    • /
    • pp.81-98
    • /
    • 2017
  • The purpose of this study is to provide basic information for the development of pants patterns with a high level of fit and comfort through calculating surface variations of lower body parts by movement, grouping them into factors, and analyzing how their surface variations link to one another. The achieved results will help determine essential elements for constructing pants patterns, such as key measurements of lower body parts, the amount of ease values and selection of fabrics, which should be taken into consideration for allowing better movement in clothing. The study required lower body 3D scanning of women for analysis, and 13 women between the ages of 20-24 participated in the scanning, which was done by using Artec Eva 3D scanner. Their scanned data were digitalized and converted to measure the values of their lower body surface length and girth in pre-determined positions such as walking, stair climbing and sitting on a chair. These measurements have been statistically analyzed through SPSS 21.0 to obtain the average amounts and rates of extension for each of the measurement item. Some of the highlighted study results are as follows: The surface length and girth measurements were grouped into 4 factors based on their average extension rates. The results from correlation analysis between measurement items within each factor demonstrated that common items linked to all the changes in the values of other items in the three movements. But in most cases, items were not always correlated with each other for different movements. The results also showed that there were correlations between girth measurements, length measurements, and girth and length measurements. Therefore, key measurements for daily pants should be determined within reasonable estimations between relevant measurement items, while the measurements for work pants, which often withstand certain postures or repetitive movements, may require measurement items that are appro priate for, and closely related to, certain movements or tasks.

Measurements of Two-dimensional Gratings Using a Metrological Atomic Force Microscope with Uncertainty Evaluation

  • Kim, Jong-Ahn;Kim, Jae-Wan;Kang, Chu-Shik;Eom, Tae-Bong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.18-22
    • /
    • 2008
  • The pitch and orthogonality of two-dimensional (2-D) gratings were measured using a metrological atomic force microscope (MAFM), and the measurement uncertainty was analyzed. Gratings are typical standard devices for the calibration of precision microscopes, Since the magnification and orthogonality in two perpendicular axes of microscopes can be calibrated simultaneously using 2-D gratings, it is important to certify the pitch and orthogonality of such gratings accurately for nanometrology. In the measurement of 2-D gratings, the MAFM can be used effectively for its nanometric resolution and uncertainty, but a new measurement scheme is required to overcome limitations such as thermal drift and slow scan speed. Two types of 2-D gratings with nominal pitches of 300 and 1000 nm were measured using line scans to determine the pitch measurement in each direction. The expanded uncertainties (k = 2) of the measured pitch values were less than 0.2 and 0.4 nm for each specimen, and the measured orthogonality values were less than $0.09^{\circ}$ and $0.05^{\circ}$, respectively. The experimental results measured using the MAFM and optical diffractometer agreed closely within the expanded uncertainty of the MAFM. We also propose an additional scheme for measuring 2-D gratings to increase the accuracy of calculated peak positions, which will be the subject of future study.

Calculation and Applicability of Rotifers Biomass (Polyarthra spp.) based on Length-Weight Relationship and Spatial Distribution of Body Length (윤충류 생체량 계산과 적용에 관한 고찰 및 제언: Polyarthra의 체장 분포를 이용한 길이-무게 관계식 및 생체량 비교 분석)

  • Oh, Hye-Ji;Seo, Dong-Hwan;Choi, Moonjung;Jeong, Hyun-Gi;Kim, Hyun-Woo;Oh, Jong Min;Chang, Kwang-Hyeon
    • Korean Journal of Ecology and Environment
    • /
    • v.51 no.3
    • /
    • pp.205-211
    • /
    • 2018
  • In this study, we estimated the applicability of length-weight relationship-based biomass calculations by comparison of body length of genus Polyarthra collected from different habitats. Through the comparison, we also tested availability of representative species-specific biomass value of Polyarthra which is often used without length measurement. Polyarthra samples were collected from rivers (Han River and Nakdong River) and reservoir (Paldang Reservoir), and the body length was measured for statistical comparison among habitats and biomass calculations using different equations suggested previously. According to the results, the body length of Polyarthra spp. was significantly different among sampling sites, and the necessity of body length measurement for rotifer species in each situation has been suggested rather than using the representative biomass values which is fixed without considering time and space. Comparison of suggested biomass calculations based on our measured Polyarthra body length, the equation suggested by McCauley showed more reasonable range of biomass values than that suggested by EPA. In addition, in order to calculate more accurate biomass, it is necessary to measure the body length of rotifers, at least more than 44 individuals to reduce error probability to less than 5% with 99% probability. However, since direct measurement of rotifers biomass is limited, it is considered that further analyses are required for more precise application of rotifer biomass of which has high variability due to complex morphologies and species-specific cyclomorphosis often induced by biotic and abiotic factors in the habitats.

Measurement of Breakup Length of Viscous Liquid Jet in Stagnant Air (정지공기중 점성유체 분류의 분열길이 측정)

  • Rhim, Jung-Hyun;Ryu, Keun-Young;Lim, Sung-Bin;No, Soo-Young
    • Journal of ILASS-Korea
    • /
    • v.3 no.4
    • /
    • pp.1-7
    • /
    • 1998
  • The measurement of breakup length of viscous liquid jet in stagnant air was conducted by a 3CCD digital video camera. The nozzle diameters of 4, 6, 8mm with L/d=50 were selected and the dynamic viscosity of viscous liquid made of glycerine and water was in the range of $1.061\times10^{-6}m^2/s$ to $4.935\times10^{-5}m^2/s$. The critical velocity is decreased and the breakup length is increased with the increase of nozzle diameter at the same dynamic viscosity of liquid. At the same nozzle diameter, the breakup length and the critical velocity are both increased with the increase of dynamic viscosity of liquid. It is found in the theoretical analysis that the initial disturbance level is the main cause of occurrance of critical Reynolds number in the stability curve. The comparison of experimental critical Reynolds number and the empirical correlation by Tanasawa and Toyota reveals the relatively good agreement.

  • PDF

Evaluation of craniofacial morphology in short-statured children: growth hormone deficiency versus idiopathic short stature

  • Kim, Ki Bong;Kim, Eun-Kyong;Jang, Kyung Mi;Kim, Min Seon;Park, Eun Young
    • Journal of Yeungnam Medical Science
    • /
    • v.38 no.1
    • /
    • pp.47-52
    • /
    • 2021
  • Background: Short stature is defined as a height below the 3rd percentile or more than two standard deviations below the mean for a given age, sex, and population. There have been inconsistent results regarding craniofacial morphology in short-statured children. This study aimed to analyze the differences between short-statured children with growth hormone deficiency, idiopathic short-statured children, and normal children. Methods: Thirty-one short-statured children with growth hormone deficiency, 32 idiopathic short-statured children, and 32 healthy children were enrolled in this study. The measurements of their craniofacial structures from lateral cephalograms were evaluated. Results: There were statistically significant differences among the three groups seven variables (anterior cranial base length, posterior cranial base length, total cranial base length, upper posterior facial height, posterior total facial height, mandibular ramus length, and overall mandibular length) in the linear measurement and five variables (saddle angle, gonial angle, mandibular plane angle, position of mandible, and maxilla versus mandible) in the angular measurement. Conclusion: Compared to the control group, many linear and angular measurements of the craniofacial structures were significantly different in the two short-statured groups (p <0.05). Treatment plans by orthodontists should include these craniofacial structure characteristics.