• 제목/요약/키워드: length and diameter of implant

검색결과 191건 처리시간 0.02초

한국환자에 매식된 ITI 임플란트에 관한 조사 (An analysis of ITI implants placed in korean patients)

  • 장문택
    • Journal of Periodontal and Implant Science
    • /
    • 제32권2호
    • /
    • pp.361-370
    • /
    • 2002
  • The aim of this study was to analyze various data of 120 non-submerged ITI implants placed in 64 korean adults. The data were retrieved from patients' charts and registered in the computer and coded for a statistical analysis. The results revealed that the most common type of edentulism was a distal extension case, and the largest number of implants were placed in the mandibular first molar position. Implants were placed more frequently in mandibular, posterior position than maxillary, anterior position, respectively. With respect to the implant diameter and length, an implant with 4.1mm in diameter and more than 10mm in length was the most common. Since a molar position was the most prevalent position for implant placement in korean patients, clinicians should be careful about implant diameter which can resist a strong occlusal force expected in the molar position. In addition, the distance to the mandibular canal and the floor of maxillary sinus should be considered to avoid possible damages, such as nerve injury and sinus perforation in selecting a proper implant length.

임플란트 지지 고정성 치과 보철물 유지방식에 따른 고정체의 직경과 길이 분포 비교 연구 (A comparative study of the distribution of implant fixtures according to length and diameter by retained type of implant-supported fixed prosthesis)

  • 김욱태
    • 대한치과기공학회지
    • /
    • 제28권2호
    • /
    • pp.347-353
    • /
    • 2006
  • The Purpose of this study was to compare the distribution of implant fixtures according to length and diameter between screw-retained and cement-retained implant-supported fixed prosthesis and to asses whether prosthesis retained types affected the selection of size of implant fixtures. This study presents a follow-up 2,416 implant-supported fixed type prosthesis that have been screw retained or cemented retained for about 10 years in 14 dental clinics. Included in the study were 458 men and 397 women and implant fixtures used in this study were screw retained type 1,057 and 1,359 of cemented retained type. The statistical results among the diameter types of fixture by prosthesis retained type was no significant difference noted (P= 0.809) and there was significant differences was enough to among the lengths of fixture by prosthesis retained type (P= 0.020). However there were no significant difference among the fixture diameter types and length by prosthesis retained type (P= 0.486). So there was not affected to prostheis fixation mechanism for the size of implant fixtures.

  • PDF

저작압, 직경, 길이 변화에 따른 임플란트 응력 분포 분석 (Analysis of Stress Contour Plot of Implant Depending on Masticatory Force, Length, and Diameter)

  • 남영준;윤승현
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제5회(2016년)
    • /
    • pp.240-245
    • /
    • 2016
  • In this paper, stress contour plots depending on length, load, and diameter of the implant are presented. Depending on the condition and amount of cortical bone, process of implanting can be difficult and stress becomes important. Therefore deciding the right length and diameter of implant is critical. When analyzing stress in the implant, Von-mises yield criterion is often used; however, due to hardship of acquiring the actual material property of surrounding bones, simplified model of a implant was adapted in finite element analysis program of EDISON. The result acquired from EDISON program was then compared with results of different research papers.

  • PDF

Assessment of demographic and clinical data related to dental implants in a group of Turkish patients treated at a university clinic

  • Bural, Canan;Bilhan, Hakan;Cilingir, Altug;Geckili, Onur
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.351-358
    • /
    • 2013
  • PURPOSE. This retrospective study analyzed the distribution of the dental implants with regards to age and gender of the patients and type of indication for the implant therapy, as well as the location, dimension and type of the implants. MATERIALS AND METHODS. The data of demographics (age and gender), type of indication for implant therapy, anatomical location, dimensions (length and diameter) and type (bone and tissue level) of 1616 implants were recorded from patient charts between January 2000 and January 2010. Descriptive statistics were analyzed using a chi-squared test for demographic parameters, type of indication, tooth position, anatomical location, implant dimensions and type (${\alpha}$=.05). RESULTS. The patient pool comprised of 350 women and 266 men, with a mean age of $52.12{\pm}13.79$ years. The difference in n% of the implants of the age groups was statistically significant between the types of indications. The difference in the position of the implants was statistically significant between the n% of the implants of all age groups. Gender did not significantly vary, except that the diameter of the implants was significantly higher for the standard diameter implants in males. The difference between the implant positions was statistically significant when considered according to indication. The relationship between implant length and anatomical location was statistically significant. CONCLUSION. The indication for dental implant use is age dependent and the type and size of the implant seems to be strongly related to the location of the implant.

APPLICATION OF FINITE ELEMENT ANALYSIS TO EVALUATE IMPLANT FRACTURES

  • Kim Yang-Soo;Kim Chang-Whe;Lim Young-Jun;Kim Myung-Joo
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.295-313
    • /
    • 2006
  • Statement of problem. Higher fracture rates were reported for Branemark implants placed in the maxilla and for 3.75 mm diameter implants installed in the posterior region. Purpose. The purpose of this study was to investigate the fracture of a fixture by finite element analysis and to compare different diameter of fixtures according to the level of alveolar bone resorption. Material and Methods. The single implant and prosthesis was modeled in accordance with the geometric designs for the 3i implant systems. Models were processed by the software programs HyperMesh and ANSA. Three-dimensional finite element models were developed for; (1) a regular titanium implant 3.75 mm in diameter and 13 mm in length (2) a regular titanium implant 4.0 mm in diameter and 13 mm in length (3) a wide titanium implant 5.0 mm in diameter and 13 mm in length each with a cementation type abutment and titanium alloy screw. The abutment screws were subjected to a tightening torque of 30 Ncm. The amount of preload was hypothesized as 650 N, and round and flat type prostheses were 12 mm in diameter, 9 mm in height were loaded to 600 N. Four loading offset points (0, 2, 4, and 6 mm from the center of the implants) were evaluated. To evaluate fixture fracture by alveolar bone resorption, we investigated the stress distribution of the fixtures according to different alveola. bone loss levels (0, 1.5, 3.5, and 5.0 mm of alveolar bone loss). Using these 12 models (four degrees of bone loss and three implant diameters), the effects of load-ing offset, the effect of alveolar bone resorption and the size of fixtures were evaluated. The PAM-CRASH 2G simulation software was used for analysis of stress. The PAM-VIEW and HyperView programs were used for post processing. Results. The results from our experiment are as follows: 1. Preload maintains implant-abutment joint stability within a limited offset point against occlusal force. 2. Von Mises stress of the implant, abutment screw, abutment, and bone was decreased with in-creasing of the implant diameter. 3. With severe advancing of alveolar bone resorption, fracture of the 3.75 and the 4.0 mm diameter implant was possible. 4. With increasing of bending stress by loading offset, fracture of the abutment screw was possible.

유한요소법을 이용한 치과 임플란트 고정체의 직경과 길이에 따른 지지골의 응력 분석 (Finite element analysis on the stress of supporting bone by diameters and lengths of dental implant fixture)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.151-156
    • /
    • 2016
  • Purpose: The dental implant should be enough to endure chewing load and it's required to have efficient design and use of implant to disperse the stress into bones properly. This study was to evaluate the stress distribution on a supporting bone by lengths and diameters of the implant fixture. Methods: The modeling and analysis of stress distribution was used for the simple molar porcelain crown model by Solidworks as FEM program. It was designed on applying with tightening torque of 20 Ncm of a abutment screw between a cement retained crown abutment and a fixture. The fixtures of experimental model used 10, 13mm by length and 4, 5mm by diameter. A external vertical loading on the two buccal cusps of crown and performed finite element analysis by 100 N. Results: The maximum von Mises stress(VMS) of all supporting bone models by fixture length and diameter were concentrated on the upper side of supporting compact bone. The maximum stress of each model under vertical load were 164.9 MPa of M410 model, and 141.2 MPa of M413 model, 54.3 MPa of M510 model, 53.6 MPa of M513 model. Conclusion: The stress reduction was increase of fixture's diameter than it's length. So it's effective to use the wider fixture as possible to the conditions of supporting bone.

하악 구치부에 식립한 sintered porous surfaced implants의 후향적 다기관 연구 (A Retrospective Study of Sintered Porous-surfaced Dental Implants in Restoring the Edentulous Posterior Mandible: Up to Eight Years of Functioning)

  • 김우성;안경미;손동석;정희승;신임희
    • 대한치과의사협회지
    • /
    • 제47권12호
    • /
    • pp.823-829
    • /
    • 2009
  • Purpose : The aim of this study was to evaluate the survival rate of sintered porous-surfaced implants placed in the edentulous posterior mandibles, in relation to implant length and diameter, crown-to-implant ratio, and types of prostheses, for a maximum of eight years of functioning. Material and Methods : The study group consisted of 43 partially edentulous patients who visited Catholic University Hospital of Daegu and one private dental clinic. A total of 122 sintered porous-surfaced implants n $Endopore^{(R)}$ (Inn ova Life Sciences, Toronto, Ontario, Canada) -- were placed in the edentulous posterior mandibles, Two diameter sizes (4.1 mm and 5.0 mm) and four lengths (5.0 mm, 7.0 mm, 9.0 mm, and 12.0 mm) were used. One hundred and three implants were splinted and 21 implants were nonsplinted. The survival rates of the implants in relation to length, diameter, crown-to-implant ratio, and types of prostheses were investigated. Statistical data were analyzed using SPSS Win.Ver 14.0 software with the Chi-square test. Results : The survival rate of the 4.1mm diameter implants was 100% and 91.2% for the 5.0mm diameter implants. The survival rates of the implants of differing diameters were found to be statistically different (p=0.005). The survival rates of both the 5.0mm and 7.0 mm length implants were 100%. The survival rate of the 9.0mm length implants was 97.9% and for the 12.0mm length implants was 95.1%. There was no statistical difference in survival rates for the differing lengths of implants. Of the 103 prostheses that were splinted, the survival rate was 98.0%. The survival rate of splinted prostheses was higher than that of the non-splinted prostheses, but was found to be not statistically different. There were no failed cases when the crown-to-implant ratio was under 1.0. When the crown-to-implant ratio was between 1.0 and 1.5, the failure rate of the implants was 6.7%. No failure was recorded with the ratio range of 1.5 to 2.0. Relative to the crown-to-implant ratio of 1.0, the failure rates were statistically different (p=0.048). Discussion and Conclusion : The cumulative survival rate of the porous-surfaced implants placed in the edentulous posterior mandibles was 97.5%. Short porous-surfaced implants showed satisfactory results after a maximum of nine years of functioning in the edentulous posterior mandibles.

  • PDF

상이한 골질과 제원에 따른 짧은 임프란트의 응력 분포: 3차원 유한 요소 분석 (STRESS DISTRIBUTION PATTERN OF THE DIFFERENT DIAMETER AND LENGTH OF SHORT IMPLANTS ACCORDING TO THE BONE QUALITY : 3-D FINITE ELEMENTS ANALYSIS)

  • 김한구;김창현;표성운
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권2호
    • /
    • pp.116-126
    • /
    • 2009
  • The use of short implants has been accepted risky from biomechanical point of view. However, short implants appear to be a long term viable solution according to recent clinical reports. The purpose of this study was to investigate the effect of different diameter and length of implant size to the different type of bone on the load distribution pattern. Stress analysis was performed using 3-dimensional finite element analysis(3D-FEA). A three-dimensional linear elastic model was generated. All implants modeled were of the various diameter(${\phi}4.0$, 4.5, 5.0 and 6.0 mm) and varied in length, at 7.0, 8.5 and 10.0 mm. Each implant was modeled with a titanium abutment screw and abutment. The implants were seated in a supporting D2 and D4 bone structure consisting of cortical and cancellous bone. An amount of 100 N occlusal load of vertical and $30^{\circ}$ angle to axis of implant and to buccolingual plane were applied. As a result, the maximum equivalent stress of D2 and D4 bones has been concentrated upper region of cortical bone. As the width of implant is increased, the equivalent stress is decreased in cancellous bone and stress was more homogeneously distributed along the implants in all types of bone. The short implant of diameter 5.0mm, 6.0mm showed effective stress distribution in D2 and D4 bone. The oblique force of 100N generated more concentrated stress on the D2 cortical bone. Within the limitations of this study, the use of short implant may offer a predictable treatment method in the vertically restricted sites.

짧은 임플란트의 생존율과 변연골 흡수량에 관한 임상적 연구 (Clinical Study on the Survival Rate and Marginal Bone Resorption of Short Implants)

  • 명태수;정승현;김태영;김유리
    • 구강회복응용과학지
    • /
    • 제28권1호
    • /
    • pp.1-13
    • /
    • 2012
  • 짧은 임플란트는 상악동이나 하치조신경 등의 해부학적 구조물이 있거나 심한 치조골 흡수로 인해 제한적인 치조제 높이를 가지는 부위에서 사용되고 있다. 본 연구는 길이 10 mm 이하의 임플란트에서 임플란트의 길이, 직경, 식립 부위, 골이식술 유무, 보철물의 연결고정 유무가 임플란트의 생존율과 변연골 흡수에 미치는 영향을 알아보고자 하였다. 원광대학교 치과병원 임플란트센터에서 길이 10 mm 이하의 임플란트를 식립한 137명의 환자, 227개 임플란트를 대상으로 진료 기록부를 통해 임플란트의 길이, 직경, 식립 위치, 골이식 유무, 보철물의 연결고정 유무를 조사하였다. 변연골 흡수량은 Emago advanced v5.6(Oral diagnostic systems, Amsterdam, The Netherlands) 프로그램을 이용하여 측정하였다. 총 227개의 임플란트 중 8개가 실패하여, 전체 짧은 임플란트의 생존율은 96.5 %로 나타났다. 골이식 부위와 상악에 식립된 경우 더 높은 실패율을 보이는 경향이 있었으며, 임플란트의 길이와 직경은 변연골 흡수량에 영향을 미치지 않았다. 실패 요인을 조사하였을 때, 상악의 불량한 골질과 골이식 유무가 임플란트의 더 높은 실패율에 영향을 미쳤다. 10 mm 이하 임플란트에서 길이, 직경, 식립 부위, 골이식술과 보철물의 연결 고정은 임플란트 생존율과 변연골 흡수량에 영향을 끼치지 않았다.

Resonance frequency analysis를 이용한 non-submerged type 임플란트의 초기 안정성 분석 (Non-submerged type implant stability analysis during initial healing period by resonance frequency analysis)

  • 김득한;방은경;김창성;최성호;조규성
    • Journal of Periodontal and Implant Science
    • /
    • 제39권3호
    • /
    • pp.339-348
    • /
    • 2009
  • Purpose: The purpose of the present study was to analyze the implant stability quotient(ISQ) values for Korean non-submerged type implant and determine the factors that affect implant stability. Methods: A total of 49 Korean non-submerged type implants were installed in 24 patients, and their stability was measured by resonance frequency analysis(RFA) at the time of surgery, and 1, 2, 3, 4, 8, 12 weeks postoperatively. The data for implant site, age, sex, implant length and diameter, graft performing, bone type, and insertion torque were analyzed. Results: The lowest mean stability measurement was at 3 weeks. There was significant difference between implant placement and 12 weeks. There was significant difference between implant placement and 12 weeks in diameters of 4.1 mm and 4.8 mm. Also, there were significant differences between diameters of 4.1 mm and 4.8 mm at implant placement and 12 weeks after surgery. This result suggests that the factor related to implant diameter may affect the level of implant stability. No statistically significant relationship was found between the resonance frequency analysis and the variables of maxilla/mandible, sex, anterior/posterior, implant length, age of patient, graft performing, bone type, insertion torque during initial healing period. Conclusions: These findings suggest that the factor related to implant diameter may affect the variance of implant stability, and ISQ value of implant was stable enough for proved stability level during initial healing period.