• Title/Summary/Keyword: left brain and right brain

Search Result 515, Processing Time 0.035 seconds

Utility Evaluation of Split VMAT Treatment Planning for Nasopharyngeal cancer (비인두암 Split VMAT 치료계획 유용성 평가)

  • Tae Yang Park;Jin Man Kim;Dong Yeol Kwon;Jun Taek Lim;Jong Sik Kim
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.13-20
    • /
    • 2022
  • Purpose : IMRT using Tomotherapy during nasopharyngeal cancer radiation therapy irradiate an accurate dose to tumor tissues and is effective to reduce a dose rapidly in normal tissues. However, this has high MU and long Beam On Time. This study aims to analyze differences in tumors, normal tissues and low-dose distributions and the efficiency of Split VMAT after applying Helical IMRT (Tomotherapy), VMAT (Linac : 2Arc) and Split VMAT (Linac : 4Arc) plans. Materials and Methods : This study targeted ten nasopharyngeal cancer patients of this hospital and compared three treatment plans (Helical IMRT, VMAT, Split VMAT). For Helical IMRT planning, Precision® (Version 1.1.1.1, Accuray, USA) was used, and for VMAT and Split VMAT planning, Pinnacle (Version 9.10, Philips, USA) was used. The total dose applied was 38.4 Gy / 32 Gy (Daily Dose 2.4 Gy (GTV + 0.3 cm) / 2 Gy (CTV + 0.3 cm) 16Fx), and for GTV + 0.3 cm (P_GTV), 95% of V38.4Gy was prescribed. VMAT with an angle of 360° 2Arc was applied, and for Split VMAT, the field was divided into the right, the left, the top and the bottom and an angle of 360° 4Arc, 6MV was set. For evaluating the quality of the treatment plans, differences in tumors, normal tissues and low-dose area were compared, and Beam On Time was measured to analyze the efficiency. Results : When calculating the mean values of evaluation items of the three treatment plans (Helical IMRT, VMAT, Split VMAT) for the patients, the H.I (Homogeneity Index) of P_GTV was 1.04, 1.11 and 1.1 respectively, and the C.I (Confomity Index) of P_CTV was 1.03, 0.99 and 1.00 respectively. The mean dose of RT Parotid Gland (Gy) was 14.54, 17.06 and 14.76 respectively, the mean dose of LT Parotid Gland (Gy) was 14.32, 17.32 and 15.09 respectively, the maximum dose of P_Cord (Spinal Cord + 0.3 cm) (Gy) was 20.57, 22.59 and 21.06 respectively, and the maximum dose of Brain Stem (Gy) was 22.35, 23.99 and 21.68 respectively. The 50% isodose curve (cc) was 1332, 1132.5 and 1065.2 respectively. Beam On Time (sec) was 373.7, 130.7 and 254.4 respectively. Conclusion : Displaying a similar treatment plan quality to Helical IMRT, which is used a lot for head and neck treatment, Split VMAT reduced the low-dose area and Beam On Time and produced a better result than VMAT. Therefore, it is considered that Split VMAT is effective not only for nasopharyngeal cancer but also for other head and neck cancers.

Clinical Observation on C.V.A. (뇌졸중(腦卒中)에 관(關)한 임상통계적(臨床統計的) 연구(硏究))

  • Yun, Jin-Goo;Cho, Ki-Ho;Kim, Young-Suk;Lee, Kyung-Sup
    • The Journal of Internal Korean Medicine
    • /
    • v.10 no.1
    • /
    • pp.25-38
    • /
    • 1989
  • Clinical observation was done on 1092 cases of cerebrovascular disease which were confirmed by Brain CT scan in Oriental Medical Hospital in Kyung Hee Univ. from May 1987 to May 1988. Specially, clinical prognosis of 250 patients who had been hospitalized for over 4 weeks, were obserbed. The results were obtained as follows; 1. In this study, Occlusive CVD was 77.9%, Cerebral hemorrhage was 18.8%, Subarachnoid hemonhage was 0.8%. 2. The ratio of male to female was 1.4:1. In the age distribution, 60th decade, 50th decade, 40th decade, 30th's, 20th's were in order of frequency and specially 60th decade was 35.53% over 70th decade was 17.1% in ratio. 3. The most common preceding disease of CVD was hypertension (54.21%) and diabetes mellitus (19.96%) was second. 4. Almost, the duration of hospitalization was 2-4 weeks in 34.8%, within 4 weeks in 78.02%. 5. Primary attack was 75.7%, 2nd attack was 17.9%, over 3rd attack was 3.1% in ratio of recurrence. 6. The level of consciousness was Grade I in 96.4%, Grade II in 3.2%, Grade III in 1% at attack. 7. A few complications of C.V.A. were observed in the studies: pneumonia was noted frequently in 3.2%, bed sore, urinary tract infection, gastro intestinal bleeding in order of frequency. 8. The ratio of neurologic deficiency in occlusive CVD decreased from 51.9% to 29.3% in upper limb, 52.6% to 24.4% in lower limb, and that in cerebral hemorrhage decreased from 69.5% to 25% in upper limb, 50% to 20% in lower limb. 9. The ratio of left side hemiplegia to right was 1.04:1 in male, 1:1.18 in female. 10. The herb medications for C.V.A. were various Chungg-Paesagantang, Sunghanggeonggisan were used most frequently to Chungyeold, Geopung, Soongi, Haldam and Chungsimtang, the drugs for Bogiheol were used as discharge. In these oriental medical therapy of C.V.A. objective diagnosis and more various therapeutic method must be obtained through east-west medical co-operation.

  • PDF

Differentiation of Parkinson's Disease and Essential Tremor on I-123 IPT(I-123-N-(3-iodopropen-2-yl)-$2{\beta}$-carbomethoxy- $3{\beta}$-(4-cholorophenyl) tropane) Brain SPECT (파킨슨병과 본태성 진전의 감별진단에서 I-123 IPT(I-123-N-(3-iodopropen-2-yl)-$2{\beta}$-carbomethoxy-$3{\beta}$-(4-cholorophenyl) tropane) 뇌 단일광전자방출 전산화단층촬영의 역할)

  • Pai, Moon-Sun;Choi, Tae-Hyun;Ahn, Sung-Min;Choi, Jai-Yong;Ryu, Won-Gee;Lee, Jae-Hoon;Ryu, Young-Hoon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.100-106
    • /
    • 2009
  • Purpose: The study was to assess I-123-N-(3-iodopropen-2-yl)-2[beta]-carbomethoxy-3[beta]-(4-cholorophenyl) tropane(IPT) SPECT in differential diagnosis among early stage of Parkinson's disease(PD) and essential tremor(ET) and normal control(NL) groups quantitatively. Materials and Methods: I-123 IPT brain SPECT of 50 NL, 20 early PD, 30 advanced PD, and 20 ET were performed at 20 minutes and 2 hours. Specific/nonspecific binding of striatum was calculated by using right and left striatal specific to occipital non-specific uptake ratio(striatum-OCC/OCC). Results: Mean value of specific/nonspecific binding ratio was significantly different between advanced PD group and NL group. However, significant overlap of striatal specific/nonspecific binding ratio was observed between PD group and ET group. Bilateral striatal specific/nonspecific binding ratios were decreased in advanced PD. Lateralized differences in the striatal uptake of I-123 IPT correlated with asymmetry in clinical findings in PD group. Conclusion: I-123 IPT SPECT may be a useful method for the diagnosis of PD and objective evaluation of progress of clinical stages. Care should be made in the differential diagnosis of early stage of PD and other motor disturbances mimicking PD such as ET in view of significant overlap in striatal I-123 specific/nonspecific binding ratio.

Crossed Cerebellar and Cerebral Cortical Diaschisis in Basal Ganglia Hemorrhage (기저핵 출혈에 의한 교차 소뇌 해리 현상)

  • Lim, Joon-Seok;Ryu, Young-Hoon;Kim, Hee-Joung;Lee, Byung-Hee;Kim, Byung-Moon;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.397-402
    • /
    • 1998
  • Purpose: The purpose of this study was to evaluate the phenomenon of diaschisis in the cerebellum and cerebral cortex in patients with pure basal ganglia hemorrhage using cerebral blood flow SPECT. Materials and Methods: Twelve patients with pure basal ganglia hemorrhage were studied with Tc-99m ECD brain SPECT. Asymmetric index (AI) was calculated in the cerebellum and cerebral cortical regions as |$C_R-C_L$/$(C_R-C_L){\times}200$, where $C_R$and $C_L$ are the mean reconstructed counts for the right and left ROIs, respectively. Hypoperfusion was considered to be present when AI was greater than mean +2 SD of 20 control subjects. Results: Mean AI of the cerebellum and cerebral cortical regions in patients with pure basal ganglia hemorrhage was significantly higher than normal controls (p<0.05): Cerebellum ($18.68{\pm}8.94$ vs $4.35{\pm}0.94$, $mean{\pm}SD$), thalamus ($31.91{\pm}10.61$ vs $2.57{\pm}1.45$), basal ganglia ($35.94{\pm}16.15$ vs $4.34{\pm}2.08$), parietal ($18.94{\pm}10.69$ vs $3.24{\pm}0.87$), frontal ($13.60{\pm}10.5$ vs $4.02{\pm}2.04$) and temporal cortex ($15.92{\pm}11.95$ vs $5.13{\pm}1.69$). Ten of the 12 patients had significant hypoperfusion in the contralateral cerebellum. Hypoperfusion was also shown in the ipsilateral thalamus (n=12), ipsilateral parietal (n=12), frontal (n=6) and temporal cortex (n=10). Conclusion: Crossed cerebellar diaschisis (CCD) and cortical diaschisis may frequently occur in patients with pure basal ganglia hemorrhage, suggesting that CCD can develop without the interruption of corticopontocerebellar pathway.

  • PDF

Automated patient set-up using intensity based image registration in proton therapy (양성자 치료 시 Intensity 기반의 영상 정합을 이용한 환자 자동화 Set up 적용 방법)

  • Jang, Hoon;Kim, Ho Sik;Choe, Seung Oh;Kim, Eun Suk;Jeong, Jong Hyi;Ahn, Sang Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.97-105
    • /
    • 2018
  • Purpose : Proton Therapy using Bragg-peak, because it has distinct characteristics in providing maximum dosage for tumor and minimal dosage for normal tissue, a medical imaging system that can quantify changes in patient position or treatment area is of paramount importance to the treatment of protons. The purpose of this research is to evaluate the usefulness of the algorithm by comparing the image matching through the set-up and in-house code through the existing dips program by producing a Matlab-based in-house registration code to determine the error value between dips and DRR to evaluate the accuracy of the existing treatment. Materials and Methods : Thirteen patients with brain tumors and head and neck cancer who received proton therapy were included in this study and used the DIPS Program System (Version 2.4.3, IBA, Belgium) for image comparison and the Eclipse Proton Planning System (Version 13.7, Varian, USA) for patient treatment planning. For Validation of the Registration method, a test image was artificially rotated and moved to match the existing image, and the initial set up image of DIPS program of existing set up process was image-matched with plan DRR, and the error value was obtained, and the usefulness of the algorithm was evaluated. Results : When the test image was moved 0.5, 1, and 10 cm in the left and right directions, the average error was 0.018 cm. When the test image was rotated counterclockwise by 1 and $10^{\circ}$, the error was $0.0011^{\circ}$. When the initial images of four patients were imaged, the mean error was 0.056, 0.044, and 0.053 cm in the order of x, y, and z, and 0.190 and $0.206^{\circ}$ in the order of rotation and pitch. When the final images of 13 patients were imaged, the mean differences were 0.062, 0.085, and 0.074 cm in the order of x, y, and z, and 0.120 cm as the vector value. Rotation and pitch were 0.171 and $0.174^{\circ}$, respectively. Conclusion : The Matlab-based In-house Registration code produced through this study showed accurate Image matching based on Intensity as well as the simple image as well as anatomical structure. Also, the Set-up error through the DIPS program of the existing treatment method showed a very slight difference, confirming the accuracy of the proton therapy. Future development of additional programs and future Intensity-based Matlab In-house code research will be necessary for future clinical applications.

  • PDF

Concealed information test using ERPs and pupillary responses (ERP와 동공 반응을 이용한 숨긴정보검사)

  • Eom, Jin-Sup;Park, Kwang-Bai;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.15 no.2
    • /
    • pp.259-268
    • /
    • 2012
  • In a P300-based concealed information test (P300 CIT), the result of the test is greatly affected by the value of the probe stimulus. With a probe stimulus of low value, the detection rate decreases. The aim of this study was to determine whether the pupil-based concealed information test (Pupil CIT) could be used in addition to the P300 CIT for the probes of low value. Participants were told to choose one card from a deck of five cards (space 2, 3, 4, 5, 6), Then a P300 CIT and a Pupil CIT for the selected card were administered. P300s were measured at 3 scalp sites (Fz, Cz, and Pz), and the pupil sizes of left and right eyes were recorded. The P300 amplitude measured at Fz, Cz, and Pz was significantly different between the probe and irrelevant stimuli. And, in the Pupil CIT, the pupil size was also different between the two stimuli for both eyes. The detection rates of the P300 CIT were 44% at Fz and Cz sites and 36% at Pz site. And the detection rates of the Pupil CIT were 52% for the left eye and 60% for the right eye. There is a trend that the detection rate of the Pupil CIT was higher than that of the P300 CIT, but the difference didn't reach significance partly because of the relatively small sample size. The correlation between the decision based on the P300 CIT and that based on the Pupil CIT was not significant. As a conclusion, it is recommended to use a Pupil CIT instead of a P300 CIT when the value of the probe is low. And a combination of the measures may be superior to either one of them in detection rate.

  • PDF

Evaluation of Antidepressant Drug Effect in a Depressive Animal Model by Proton MR Spectroscopy (양성자 자기공명분광법을 이용한 우울증 동물모델에서의 항우울제 약물 효능 평가)

  • Kim, Sang-Young;Choi, Chi-Bong;Lee, Sung-Ho;Woo, Dong-Cheol;Yoon, Seong-Ik;Hong, Kwan-Soo;Lee, Hyun-Sung;Cheong, Chae-Joon;Jee, Bo-Keun;Hong, Sung-Tak;Kim, Hwi-Yool;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.95-101
    • /
    • 2008
  • In this study, we observed the alteration of choline signal intensity in hippocampus region of the depressive rat model induced by forced swimming test (FST). The purpose of this study was to evaluate the antidepressant efficacy in the depressive animal model using MR spectroscopy. Fourteen experimentally naive male Sprague-Dawley rats weighting $160{\sim}180\;g$ were used as subjects. Drug injection group was exposed to the FST except for control group. The drugs were administered subcutaneously (SC) in a volume equivalent to 2ml/kg. And three injections were administered 23, 5, and 1h before beginning the given test. 1H MR spectra were obtained with use of a point resolved spectroscopy (PRESS) localization sequence performed according to the following parameters: repetition time, 2500 ms; echo time, 144 ms; 512 average; 2048 complex data points; voxel dimensions, $1.5{\times}2.5{\times}2.5\;mm^3$ ; acquisition time, 25min. There were no differences in NAA/Cr and Cho/Cr ratio between the right and the left hippocampus both normal control rats and antidepressant-injected rats. Also, no differences were observed in NAA/Cr and Cho/Cr ratio between the normal control rats and the antidepressant-injected rats both the right and the left hippocampus. In this study, we found the recovery of choline signals in the depressive animal model similar to normal control groups as injecting desipramine-HCl which was antidepressant causing anti-immobility effects. Thus, we demonstrated that MR spectroscopy was able to aid in evaluating the antidepressant effect of desipramine-HCl.

  • PDF

Shoulder Uptake in the Bone Scintigraphy in Patients with Hemiplegic Reflex Sympathetic Dystrophy Syndrome (반신마비성 반사성교감신경 이영양증후군 환자의 골스캔상 견관절 섭취)

  • Lee, Jong-Jin;Chung, June-Key;Lee, Dong-Soo;Hong, Joon-Beom;Han, Tai-Ryoon;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.288-293
    • /
    • 2004
  • Purpose: increased uptake of wrist and hand joints in three phase bone scintigraphy (TPBS) have been used in the detection of reflex sympathetic dystrophy syndrome (RSDS). TPBS frequently shows increased shoulder uptake in the hemiplegic RSDS patients. We investigated the significance of the shoulder uptake in the detection of these patients. Materials and Methods: Twenty three patients who had hemiplegia due to brain stroke and diagnosed as RSD were enrolled in this study (M:F=16:7, R:L=11:12). The mean age was $63{\pm}10$ yrs. Ter normal volunteer (mean age: $60{\pm}5$, M:F=1:9) data was used as control group. TPBS was performed $59{\pm}32$ days after stoke (acute stage). We obtained the count ratios of bilateral hands by drawing a region of interest (ROI) in three phase images and compared to the count ratios of shoulders in the delayed image. Hand ROI included an ipsilateral wrist. Sensitivity of detecting the affected limb was defined using the right/left count ratio of normal control. Results: Sensitivities using count ratios of hand blood flow, blood pool and delayed image were 45%, 76% and 78%, respectively. Sensitivity of shoulder count ratio was 74%. Log of right/left counts of hand delayed image and that of shoulder delayed image were correlated well with statistical significance (Spearman's R=0.824, p<0.001). Conclusion: Shoulder uptake showed good correlation with hand uptake in the delayed image of TPBS. Shoulder uptake maybe helpful in the diagnosis of reflex sympathetic dystrophy syndrome in patients with hemiplegia.

Study on the Characteristics of EEG in Resting State on Visuo-Spatial Working Memory Performance (시공간 작업기억 수행능력에 따른 안정상태에서의 뇌파 특성 연구)

  • Jung, Chul-Woo;Lee, Hyeob-Eui;Wi, Hyun-Wook;Choi, Nam-Sook;Park, Pyong-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.351-360
    • /
    • 2016
  • The purpose of this study is to predict visual-spatial working memory performance through the characteristics of an electroencephalogram (EEG) in the resting state. The 31 study participants, middle school students with various to academic performance, were underwent visual-spatial working memory test in the Comprehensive Attention Test (CAT) on December in 2014. Each 7 and 6 participants were divided into an Excellent Working Memory (EWM) group and Poor Working Memory (PWM) group depending on the forward/backward working memory scores. The EEG measurements and analysis of the data from a Brain Function Tester were performed by the two groups. A Mann-Whitney Test was used to examine the statistical differences between them. The activation of high beta (${\beta}H$) at the Fp1 and Fp2 sites in the left and right hemisphere, and that of the low beta (${\beta}L$) in the right hemisphere in the EWM group was significantly higher than that in the PWM group. In conclusion, there is a correlation between the visual-spatial working memory performance and the activation of ${\beta}H$ and ${\beta}L$ in the resting state and a close correlation that of ${\beta}L$ in the right hemisphere in terms of mental activity and faculty. Therefore, the visual-spatial working memory performance can be predicted by the activation of ${\beta}H$ and ${\beta}L$ in the resting state. The activation of EEG can be applied as an assessment tool and provide basis data for visual-spatial working memory performance.

The Evaluation of Radiation Dose to Embryo/Fetus and the Design of Shielding in the Treatment of Brain Tumors (임산부의 전뇌 방사선 치료에 있어서의 태아의 방사선량 측정 및 차폐 구조의 설계)

  • Cho, Woong;Huh, Soon-Nyung;Chie, Eui-Kyu;Ha, Sung-Whan;Park, Yang-Gyun;Park, Jong-Min;Park, Suk-Won
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.203-210
    • /
    • 2006
  • Purpose : To estimate the dose to the embryo/fetus of a pregnant patient with brain tumors, and to design an shielding device to keep the embryo/fetus dose under acceptable levels Materials and Methods : A shielding wall with the dimension of 1.55 m height, 0.9 m width, and 30 m thickness is fabricated with 4 trolleys under the wall. It is placed between a Patient and the treatment head of a linear accelerator to attenuate the leakage radiation effectively from the treatment head, and is placed 1 cm below the lower margin of the treatment field in order to minimize the dose to a patient from the treatment head. An anti-patient scattering neck supporters with 2 cm thick Cerrobend metal is designed to minimize the scattered radiation from the treatment fields, and it is divided into 2 section. They are installed around the patient neck by attach from right and left sides. A shielding bridge for anti-room scattered radiation is utilized to place 2 sheets of 3 mm lead plates above the abdomen to setup three detectors under the lead sheets. Humanoid phantom is irradiated with the same treatment parameters, and with and without shielding devices using TLD, and ionization chambers with and without a build-up cap. Results : The dose to the embryo/fetus without shielding was 3.20, 3.21, 1.44, 0.90 cGy at off-field distances of 30, 40, 50, and 60 cm. With shielding, the dose to embryo/fetus was reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy. The dose measured by the survey meter was 10.9 mR/h at the patient's surface of abdomen. The dose to the embryo/fetus was estimated to be about 1 cGy during the entire treatment. Conclusion : According to the AAPM Report No 50 regarding the dose limit of the embryo/fetus during the pregnancy, the dose to the embryo/fetus with little risk is less than 5 cGy. Our measurements satisfy the recommended values. Our shielding technique was proven to be acceptable.