Browse > Article

Utility Evaluation of Split VMAT Treatment Planning for Nasopharyngeal cancer  

Tae Yang Park (Department of Radiation Oncology, Samsung Medical Center)
Jin Man Kim (Department of Radiation Oncology, Samsung Medical Center)
Dong Yeol Kwon (Department of Radiation Oncology, Samsung Medical Center)
Jun Taek Lim (Department of Radiation Oncology, Samsung Medical Center)
Jong Sik Kim (Department of Radiation Oncology, Samsung Medical Center)
Publication Information
The Journal of Korean Society for Radiation Therapy / v.34, no., 2022 , pp. 13-20 More about this Journal
Abstract
Purpose : IMRT using Tomotherapy during nasopharyngeal cancer radiation therapy irradiate an accurate dose to tumor tissues and is effective to reduce a dose rapidly in normal tissues. However, this has high MU and long Beam On Time. This study aims to analyze differences in tumors, normal tissues and low-dose distributions and the efficiency of Split VMAT after applying Helical IMRT (Tomotherapy), VMAT (Linac : 2Arc) and Split VMAT (Linac : 4Arc) plans. Materials and Methods : This study targeted ten nasopharyngeal cancer patients of this hospital and compared three treatment plans (Helical IMRT, VMAT, Split VMAT). For Helical IMRT planning, Precision® (Version 1.1.1.1, Accuray, USA) was used, and for VMAT and Split VMAT planning, Pinnacle (Version 9.10, Philips, USA) was used. The total dose applied was 38.4 Gy / 32 Gy (Daily Dose 2.4 Gy (GTV + 0.3 cm) / 2 Gy (CTV + 0.3 cm) 16Fx), and for GTV + 0.3 cm (P_GTV), 95% of V38.4Gy was prescribed. VMAT with an angle of 360° 2Arc was applied, and for Split VMAT, the field was divided into the right, the left, the top and the bottom and an angle of 360° 4Arc, 6MV was set. For evaluating the quality of the treatment plans, differences in tumors, normal tissues and low-dose area were compared, and Beam On Time was measured to analyze the efficiency. Results : When calculating the mean values of evaluation items of the three treatment plans (Helical IMRT, VMAT, Split VMAT) for the patients, the H.I (Homogeneity Index) of P_GTV was 1.04, 1.11 and 1.1 respectively, and the C.I (Confomity Index) of P_CTV was 1.03, 0.99 and 1.00 respectively. The mean dose of RT Parotid Gland (Gy) was 14.54, 17.06 and 14.76 respectively, the mean dose of LT Parotid Gland (Gy) was 14.32, 17.32 and 15.09 respectively, the maximum dose of P_Cord (Spinal Cord + 0.3 cm) (Gy) was 20.57, 22.59 and 21.06 respectively, and the maximum dose of Brain Stem (Gy) was 22.35, 23.99 and 21.68 respectively. The 50% isodose curve (cc) was 1332, 1132.5 and 1065.2 respectively. Beam On Time (sec) was 373.7, 130.7 and 254.4 respectively. Conclusion : Displaying a similar treatment plan quality to Helical IMRT, which is used a lot for head and neck treatment, Split VMAT reduced the low-dose area and Beam On Time and produced a better result than VMAT. Therefore, it is considered that Split VMAT is effective not only for nasopharyngeal cancer but also for other head and neck cancers.
Keywords
Helical IMRT; VMAT; Split VMAT;
Citations & Related Records
연도 인용수 순위
  • Reference
1 P. Jardel, J. Thariat, P. Blanchard, et al.: Nasopharyngeal cancers, an overview. Bulletin du Cancer. 2014;101(5):445-454   DOI
2 Yi Rong, James S Welsh: Dosimetric and clinical review of Tomo tomotherapy. Expert Review of Anticancer Therapy. 2011;11(2):309-320.   DOI
3 Jie Qiu, Zhikai Liu, Bo Yang, Xiaorong Hou, et al.: Low-Dose-Area-Constrainted Tomo TomoTherapy-Based Whole Breast Radiotherapy and Dosimetric Comparison with Tangential Field-in-Field IMRT. BioMed Research International. 2013;10.1155.
4 Otto K: Volumetric modulated arc therapy : IMRT in a single gantry arc. Med Phys. 2008;35(1):310-317.   DOI
5 문준기, 손상준, 김대호 등: 골반 림프선을 포함한 전립선암치료 시 Split VMAT plan의 유용성 평가. 대한방사선치료학회. 2015;27(2):145~156.
6 Feuvret L, Noel G, Mazeron JJ et al.: Conformity index: a review. Int J Radiat Oncol Biol Phys. 2006;64(2):333-342.   DOI