• 제목/요약/키워드: leakage test

검색결과 1,007건 처리시간 0.026초

버터플라이밸브 성능 및 수명시험장치 개발과 개선에 관한 연구 (A Study of Development and Improvement for Butterfly Valve Performance & Life Test Equipment)

  • 이기천;김형의;정동수;김재훈
    • 한국유체기계학회 논문집
    • /
    • 제15권2호
    • /
    • pp.51-56
    • /
    • 2012
  • The butterfly valve has been used over all industries. It has been studied to improve its performance through the theoretical analysis and the test in industry. Though products adopted those improvements have been sold in markets, manufacturers often launch products without the life test. One reason is because of the long development period and financial difficulties. The other is the lack of the design and fabrication experiences on building the life test equipment. Thus, this study has been researched for the design and fabrication of our life test equipment, and developed and improved the equipment to check the leakage of the valve with the naked eyes during the test.

LNG 배관 시스템용 1인치 글로브 밸브 개발 및 성능실험 (Development and Performance Test on the 1-Inch Glove Valve for the LNG Piping System)

  • 이중섭;이치우
    • 한국기계가공학회지
    • /
    • 제16권1호
    • /
    • pp.9-16
    • /
    • 2017
  • This study describes the development of a 1-inch cryogenic glove valve for an LNG pumping system and localization development achieved through the performance test. The cryogenic valve used in the LNG pumping system plays an important role in maintaining a flow rate by LNG transportation. This trial manufactured goods, which was achieved through reverse engineering and developing the assembly process. The result of the leak test satisfied the internal pressure condition using the 78-bar normal temperature test and maintained the anti-leakage condition. Also, the result of the cryogenic leak test (BS 6364: low temperature test procedure) maintained anti-leakage at -196 and 52 bar, which satisfied the test standards.

Optimum Harvest Time for High Quality Seed Production of Sweet and Super Sweet Corn Hybrids

  • Lee Suk Soon;Yun Sang Hee;Seo Jung Moon
    • 한국작물학회지
    • /
    • 제49권5호
    • /
    • pp.373-380
    • /
    • 2004
  • The production of sweet (su) and super sweet corns (sh2) has been economically feasible in Korea in recent years. Major factors limiting super sweet corn production are low germination and low seedling vigor. Since seed quality is closely related to seed maturity, the optimum harvest time for the seed production of sweet and super sweet corns was studied and the quality of seeds with varying maturities was investigated in 2001 and 2002 cropping seasons. The parents of the sweet corn seeds were Hybrid Early Sunglow and 'Golden Cross Bantam 70' and those of super sweet corn were Xtrasweet 82 and 'For­tune'. Seeds were harvested at 21, 28, 35, 42, 49, and 56 days after silking (DAS). As the seeds developed, seed weight of sweet corn increased and the seed moisture content decreased faster than that of super sweet corn. Germination rates of sweet corn seeds harvested 21 and 28 DAS at $25^{\circ}C$ and emergence rates in the cold soil test were significantly lower than those of seeds harvested after 42 DAS in both years. Although the germination rates of super sweet corn seeds with varying maturities showed similar patterns as sweet corn seeds at $25^{\circ}C$, the emergence rate of super sweet corn seeds in cold soil test continuously increased with seed maturity. This suggests that seed quality of super sweet corn should be tested in a cold soil test to estimate field emergence. As the seeds developed, leakage of total sugars and electrolytes from the both sweet and super sweet corn seeds decreased up to 42 or 49 DAS. The $\alpha-amylase$ activities of both sweet and super sweet corn seeds increased with seed maturity from 21 to 35 or 49 DAS depending on genotype and year. The optimum harvest time for the seed production of sweet corn was 42 DAS and 49 DAS for super sweet corn considering emergence rate and plumule dry weight in the cold soil test, leakage of sugars and electrolytes from the seeds, and $\alpha-amylase$ activity.

Silicon rubber 애자의 salt-fog 표면열화 특성 (Surface Aging Properties of Silicon Rubber Insulator by salt-fog)

  • 이종찬;이운용;조한구;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.255-257
    • /
    • 2001
  • In this paper, the silicon rubber insulator for transmission line was experimented for 1,000 hours aging test in salt-fog condition. To evaluate and examine the aging properties of silicon rubber insulator for test, the leakage current of surface was measured. Also hydrophobicity and scanning electron microscopy were compared with initial and aged sample respectively Above results, we can confirm that the surface properties of silicon rubber insulator easily aged by salt-fog condition.

  • PDF

LCD의 Leakage 현상을 고려한 색재현 (Color Reproduction Based on Leakage Effect of LCD)

  • 허태욱;이상훈;한찬호;송규익
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(4)
    • /
    • pp.243-246
    • /
    • 2000
  • Recently, PC monitor users have been replacing cathode ray tubes (CRT) with liquid crystal displays (LCD). But the chromaticity of the primaries are dependent on RGB input signals. And the colorimetry of LCD changes with gray scale and has a poor peformance in color reproduction. In this paper we propose the enhanced algorithm of color reproduction considering color leakage error and black subpixel error in LCD. In order to test peformance of this algorithm we use the colors of Macbeth colorcheck. As a result of experiments, it was confirmed that the color difference of the LCD using the proposed algorithm was considerably reduced.

  • PDF

영광 #1/2 복수기 누수부 보수공사 (Yeonggwang #1/2 steam condenser leakage repair works)

  • 이상철;공창식
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2003년도 춘계학술발표대회 개요집
    • /
    • pp.117-119
    • /
    • 2003
  • Power plant efficiency and availability depend greatly on condenser performance. However, during commissioning of Yeonggwang #1/2 steam condenser sodium leakage occurred, because of tube to tubesheet only roll expanding. Therefore this report is explaining that pre-test for the shake of improvement reliable repair processes & selected sampling tube re-expansion in-situ applications.

  • PDF

제습로터의 공기누설모델 개발 및 성능 특성에 관한 실험적 연구 (Experimental Study on Development of Air Leakage Model and Performance Characteristics of a Desiccant Rotor)

  • 강병하;피창헌;장영수
    • 대한기계학회논문집B
    • /
    • 제36권1호
    • /
    • pp.37-45
    • /
    • 2012
  • 제습로터에서 발생하는 공기누설은 로터와 브러쉬 형태의 누설방지모 틈새의 양단 사이 차압에 의해 발생하는 압력누설이 지배적이며, 실험을 통해 압력누설특성을 파악하였다. 그 결과로, 압력누설량을 로터와 누설방지모의 틈새면적과 차압의 함수로 나타내었다. 위의 상관식을 바탕으로 제습로터의 공기누설모델을 개발하였으며, 실험을 통해 측정된 값과 위 모델을 바탕으로 계산된 값을 비교함으로써 공기누설모델을 검증하였다. 그리고 풍량에 따른 제습로터의 성능실험을 수행하였으며, 공기누설모델을 적용한 성능 분석을 통하여 실질적인 제습량과 공기누설량을 확인 하였다. 또한 동일한 제습로터가 적용된 제습냉방시스템을 고려하여 차압변화에 따른 공기누설의 영향을 공기누설모델을 이용하여 고찰하였다.

직류+60[Hz] 교류 중첩전압에 대한 ZnO 피뢰기 소자의 전기적 특성 (Electrical Characteristics of ZnO Surge Arrester Elements Subjected to the Mixed DC and 60[Hz] AC Voltages)

  • 이복희;양순만
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.41-47
    • /
    • 2012
  • This paper deals with the electrical characteristics related to power loss, equivalent resistance, and leakage currents flowing through new and deteriorated zinc oxide(ZnO) arrester elements subjected to the mixed DC and 60[Hz] AC voltages. The test specimens were deteriorated by 8/20[${\mu}s$] impulse current of 2.5[kA]. The leakage current-applied voltage($I-V$) characteristic curves of ZnO surge arrester elements were measured as a parameter of the ratio of the peak of 60[Hz] AC voltage to the peak of total voltage. As a consequence of test results, in case of the same applied voltage, the leakage currents flowing through the deteriorated ZnO arrester elements were higher than those flowing through the new ZnO surge arrester elements. The cross-over phenomenon in $I-V$ curves of ZnO surge arrester elements measured as a parameter of the mixed ratio of DC and AC voltages was observed at the low current domain. The effect of DC voltage on the leakage current flowing through ZnO surge arrester elements is pronounced at the same magnitude of test voltages. In addition, the larger the applied number of 8/20[${\mu}s$] impulse current of 2.5[kA] is, the greater the power loss is, in particular, the more severe the power loss increases at higher applied voltages.

외부 환경조건에 따른 ZnO 피뢰기의 전기적 특성의 변화 (Changes in Electrical Properties of ZnO Surge Arresters According to Surrounding Conditions)

  • 이승주;이수봉;이복희
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.62-68
    • /
    • 2008
  • 이 논문은 ZnO 피뢰기의 외부환경 변화에 따른 전기적 특성을 기술하였다. 뇌임펄스전류에 의한 ZnO 피뢰기의 열화특성을 분석하기 위해 8/20[${\mu}s$], 2.5[kA]의 임펄스전류를 시료에 인가하였다. ZnO 피뢰기의 누설전류를 다양한 외부 온도와 주수 상태에서 상용 주파수 교류 전압을 인가하여 측정하였다. 그 결과 임펄스전류의 인가횟수와 외부 온도가 증가함에 따라 누설전류가 증가하였고, 누설전류의 비대칭성도 뚜렷하였다. 또한 주수 시험에서 ZnO 피뢰기의 외피를 통하여 흐르는 전류는 피뢰기 소자의 누설전류보다 크게 나타났다. 본 연구의 결과는 피뢰기의 감시시스템 성능과 신뢰성 향상의 요소로 적용할 수 있다.

옥외 전기시설물 침수시 누설전류에 의한 인체영향 (Human Hazard by Outdoor Electrical Facilities in Submerged Area)

  • 하태현;이현구;배정효;김대경
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권12호
    • /
    • pp.602-607
    • /
    • 2003
  • We show three-dimensional distribution of voltages resulted from the leakage current originated from outdoor electrical facilities in a submerged area. In case these facilities are grounded by the neutral line multiple grounding method, the existence of ungrounded electrical facilities can cause a disastrous effect on near-by passengers. In order to investigate this situation, we installed a real-scale test field for the experiment type I (for the leakage current path between a enclosure grounded electrical facility and another enclosure grounded one), and that for the experiment type II (for the leakage current path between a enclosure grounded electrical facility and another ungrounded one). For both cases, we carried out three-dimensional monitoring of the voltage distribution while varying additional conditions such as the exposure of the underground cables and the finishing of cable connection part. The result shows that a disastrous effect on human safety can arise from the leakage current without a pertinent measure for the construction and maintenance of outdoor electrical facilities.