• Title/Summary/Keyword: leakage detector

Search Result 105, Processing Time 0.026 seconds

The Electrical and Radiation Detection Properties of $Au/Cd_{1-x}Zn_x/Te(x=20%)/Au$ Structure ($Au/Cd_{1-x}Zn_x/Te(x=20%)/Au$ 구조의 전기적 특성 및 방사선 탐지 특성)

  • 최명진;왕진석
    • Electrical & Electronic Materials
    • /
    • v.10 no.1
    • /
    • pp.39-44
    • /
    • 1997
  • Bulk type radiation detector of Au/Cd$_{1-x}$ Zn$_{x}$Te(x=20%)/Au structure using Cd$_{1-x}$ Zn$_{x}$Te(x=20%) wafer(3x4xl mm$^{3}$) grown by high pressure Bridgman method has been developed. We etched wafer surfaces with 2% Br-methanol solution and coated gold thin film on the surfaces by electroless deposition method for 5 min. in 49/o HAuCI$_{3}$ 4H20 solution. Initial etch rates of Cd, Zn and Te were 46%, 12% and 42% respectively. After etched, the surface of wafer was slightly revealed to Te rich condition. The leakage current was increased with etch time, but it didn't exceed 3nA at 50volt. The thickness of Au film was about 100nm by Rutherford Backscattering Spectroscopy(RBS). The resolution were 6.7% for 22.1 keV photon from 109 $^{109}$ Cd and 8.2% for 59.5 keV photon from $^{241}$ Am. The radiation detector such as Au/Cd$_{1-x}$ Zn$_{x}$Te(x=20%)/Au structure was more effective to monitor the low energy gamma radiation.iation.

  • PDF

Fundamental evaluation of hydrogen behavior in sodium for sodium-water reaction detection of sodium-cooled fast reactor

  • Tomohiko Yamamoto;Atsushi Kato;Masato Hayakawa;Kazuhito Shimoyama;Kuniaki Ara;Nozomu Hatakeyama;Kanau Yamauchi;Yuhei Eda;Masahiro Yui
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.893-899
    • /
    • 2024
  • In a secondary cooling system of a sodium-cooled fast reactor (SFR), rapid detection of hydrogen due to sodium-water reaction (SWR) caused by water leakage from a heat exchanger tube of a steam generator (SG) is important in terms of safety and property protection of the SFR. For hydrogen detection, the hydrogen detectors using atomic transmission phenomenon of hydrogen within Ni-membrane were used in Japanese proto-type SFR "Monju". However, during the plant operation, detection signals of water leakage were observed even in the situation without SWR concerning temperature up and down in the cooling system. For this reason, the study of a new hydrogen detector has been carried out to improve stability, accuracy and reliability. In this research, the authors focus on the difference in composition of hydrogen and the difference between the background hydrogen under normal plant operation and the one generated by SWR and theoretically estimate the hydrogen behavior in liquid sodium by using ultra-accelerated quantum chemical molecular dynamics (UA-QCMD). Based on the estimation, dissolved H or NaH, rather than molecular hydrogen (H2), is the predominant form of the background hydrogen in liquid sodium in terms of energetical stability. On the other hand, it was found that hydrogen molecules produced by the sodium-water reaction can exist stably as a form of a fine bubble concerning some confinement mechanism such as a NaH layer on their surface. At the same time, we observed experimentally that the fine H2 bubbles exist stably in the liquid sodium, longer than previously expected. This paper describes the comparison between the theoretical estimation and experimental results based on hydrogen form in sodium in the development of the new hydrogen detector in Japan.

Optimization of Gas Detector Location by Analysis of the Dispersion Model of Hazardous Chemicals (유해화학물질의 확산 모델 분석을 통한 가스감지기 위치 최적화)

  • Jeong, Taejun;Lim, Dong-Hui;Kim, Min-Seop;Lee, Jae-Geol;Yoo, Byung Tae;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.2
    • /
    • pp.39-48
    • /
    • 2022
  • The domestic gas detector installation standards applied to gas detectors, which are one of the facilities that can prevent accidents such as fire, explosion, and leakage that can cause serious industrial accidents, do not take into account the behavioral characteristics of hazardous chemicals in the atmosphere. It can be seen that the technical basis is insufficient because the standard is applied. Therefore, in this study, the size of the leak hole for each facility mainly used in chemical plants and the diffusion distance according to the concentration of interest of hazardous chemicals were analyzed, and based on this, the optimal installation distance for gas detectors for each material was suggested. Using the method presented in this study, more economical and effective gas detector installation can be expected, and furthermore, it can be expected to help prevent serious industrial accidents.

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

Modeling for UV Photo-detector with Pt/AIGaN Schottky diode (Pt/AIGaN 쇼트키 다이오드의 수광특성 모델링)

  • Kim Jong-Hwan;Lee Heon-Bok;Park Sung-Jong;Lee Jung-Hee;Hahm Sung-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.605-608
    • /
    • 2004
  • A $Pt/Al_xGa_{l-x}N$ Schottky type Ultra-violet photodetector was modeled and simulated using the commercial SILVACO software program. In the carrier transport, we applied field model and other analytic model to determine the electron saturation velocity and low field mobility for GaN and $Al_xGa_{l-x}N$. A C-Interpreter function was defined to described the mole-fraction for the ternary compound semiconductor such as $Al_xGa_{l-x}N$. As comparing the simulated and experimental results, we found that the simulated result for type-1 has $15.9 nA/cm^2$ of leakage current at 5V. We confirmed a good agreement of photo-current in the UV Photo-detector, while applying the absorption coefficient and reflective index of active $Al_xGa_{l-x}N$ and other layers. There had been an intensive search for the proper refractive indices of the layers.

  • PDF

Development of Parallel Arc Fault Detector Using Ripple Voltage (리플전압을 이용한 병렬아크 사고 감지기 개발)

  • Choi, Jung-Kyu;Kwak, Dong-Kurl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.453-456
    • /
    • 2016
  • The major causes of electrical fire in low-voltage distribution lines are classified into short-circuit fault, overload fault, electric leakage, and electric contact failure. The special principal factor of the fire is electric arc or spark accompanied with such electric faults. This paper studies the development of an electric fire prevention system with detection and alarm of that in case of parallel arc fault occurrence in low-voltage distribution lines. The proposed system is designed on algorithm sensing the instantaneous voltage drop of line voltage at arc fault occurrence. The proposed detector has characteristics of high-speed operation responsibility and superior system reliability from composition using a large number of semiconductor devices. A new sensing control method that shows the detection of parallel arc fault is sensed to ripple voltage drop through a diode bridge full-wave rectifier at electrical accident occurrence. Some experimental tests of the proposed system also confirm the practicality and validity of the analytical results.

Preventive diagnostic system for 765kV Sin-Ga-Pyong and Sin-Tae-Baek substations (765kV 신가평, 신태백 변전소 예방진단시스템)

  • Kweon, D.J.;Shim, E.B.;Jung, G.J.;Kim, B.J.;Kim, J.H.;Yoo, Y.P.;Eun, J.Y.;Shin, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1694-1697
    • /
    • 2002
  • KEPCO is planing to adopt a preventive diagnostic system to obtain the reliability of transformer and GIS in 765kV substation. KEPRI has developed the preventive diagnostic system for 765kV substation since 1997. We used various sensors and fault detecting devices such as a dissolved gas analyzer in oil, a ultrasonic detector and LA leakage current detector, etc., and carried out adaptation tests at the both a laboratory and a site. We developed a data acquisition system, a communication control unit and a server system as well. Furthermore, monitoring program and diagnostic expert system were also developed. This paper describes the preventive diagnostic system for 765kV Sin-Ga-Pyong and Sin-Tae-Baek substations which will be operated from 2004.

  • PDF

I-V Measurements of large area $HgI_2$ X-ray detector produced by PIB method (PIB법을 이용한 대면적 $HgI_2$ 검출기의 I-V 특성평가)

  • Kim, Kyung-Jin;Park, Ji-Koon;Kang, Sang-Sik;Cha, Byung-Youl;Cho, Sung-Ho;Sin, Jeong-Uk;Mun, Chi-Ung;Nam, Sang-Hee;Kim, Jin-Yung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.254-255
    • /
    • 2005
  • In this paper, we investigated electrical characteristics of the X-ray detector of mercuric iodide (HgI2) film fabricated by PIB(Particle-in-Binder) Method on ITO substrates 17cm$\times$20cm in size with thicknesses ranging from approximately 200${\mu}m$ to 240${\mu}m$. In the present study, using I-V measurements, their electrical properties such as leakage current, X-ray sensitivity, and signal-to-noise ratio (SNR),were investigated. The results of our study can be useful in the future design and optimization of direct active-matrix flat-panel detectors (AMFPD) for various digital X-ray imaging modalities.

  • PDF

A Study on the Design of Low Power Digital PLL (저전력 디지털 PLL의 설계에 대한 연구)

  • Lee, Je-Hyun;Ahn, Tae-Won
    • 전자공학회논문지 IE
    • /
    • v.47 no.2
    • /
    • pp.1-7
    • /
    • 2010
  • This paper presents a low power digital PLL architecture and design for implementation of the PLL-based frequency synthesizers. In the proposed architecture, a wide band digital logic quadricorrelator is used for preliminary frequency detector and a narrow band digital logic quadricorrelator is used for final DCO control. Also, a circuit technique for reducing leakage current is adopted in order to minimize the standby mode power consumption of the deactivated block. The proposed digital PLL is designed and verified by MyCAD with MOSIS 1.8V $0.35{\mu}m$ CMOS technology, and the simulation results show that the power consumption can be lowered by more than 20%.