• Title/Summary/Keyword: leakage detection

Search Result 458, Processing Time 0.027 seconds

A Study on a Remote Leakage Sensing System in Waterworks Network (원격 상수도관망 누수감지 시스템에 관한 연구)

  • Kang, Byung-Mo;Hong, In-Sik
    • The KIPS Transactions:PartD
    • /
    • v.11D no.6
    • /
    • pp.1311-1318
    • /
    • 2004
  • Demand of water is increased according to city centralism phenomenon in population and development. In this progress, guarantee of enough water is important factor for water supply policy. For the detection of exact water leakage point, an epochal sensing technique using computer and internet is required, so, the water pipe having sensing wire and sensing technology using TDR(Time Domain Reflectometer), is proposed in this paper. For the prove of effectiveness of this system, pilot system using 300mm 3-layer coated steel pipe is made and tested.

Implementation of an Export System for GIS Arrester Facilities (GIS 피뢰설비 전문가 시스템 구현)

  • Kim, Il-Kwon;Song, Jae-Yong;Moon, Seung-Bo;Cha, Myung-Soo;Rhyu, Keel-Soo;Kil, Gyung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1465-1466
    • /
    • 2006
  • The monitoring and diagnosing technique for lightning arresters is important to assure the reliability of power supply in GIS-substation. In this paper, we described the implementation of an expert system for GIS arrester facilities. The proposed system consists of a data acquisition module (DAM), a wireless communication module, and a personal computer. The DAM detects system voltages, total leakage currents and its harmonic components, and includes an algorithm to calculate the resistive leakage current by the principle that the magnitudes of resistive leakage current are equal at the same level of the system voltage applied to the arrestor. Also, we designed a surge event detection circuit which can acquire the date, the polarity, and the amplitude of surge events. All the acquired data are transmitted after correction by many algorithms to the remote station through the ZigBee protocol. The expert system is based on the Jave Expert System Shell (JESS) and make more reliable decision by using an exclusive inference process.

  • PDF

Safety Monitoring Sensor for Underground Subsidence Risk Assessment Surrounding Water Pipeline (상수도관로의 주변 지반침하 위험도 평가를 위한 안전감시 센서)

  • Kwak, Pill-Jae;Park, Sang-Hyuk;Choi, Chang-Ho;Lee, Hyun-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.306-310
    • /
    • 2015
  • IoT(Internet of Things) based underground risk assessment system surrounding water pipeline enables an advanced monitoring and prediction for unexpected underground hazards such as abrupt road-side subsidence and urban sinkholes due to a leak in water pipeline. For the development of successful assessment technology, the PSU(Water Pipeline Safety Unit) which detects the leakage and movement of water pipes. Then, the IoT-based underground risk assessment system surrounding water pipeline will be proposed. The system consists of early detection tools for underground events and correspondence services, by analyzing leakage and movement data collected from PSU. These methods must be continuous and reliable, and cover certain block area ranging a few kilometers, for properly applying to regional water supply changes.

Novel Adaptive Blanking Regulation Scheme for Constant Current and Constant Voltage Primary-side Controlled Flyback Converter

  • Bai, Yongjiang;Chen, Wenjie;Yang, Xiaoyu;Yang, Xu
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1469-1479
    • /
    • 2017
  • Primary-side regulation (PSR) scheme is widely applied in low power applications, such as cell phone chargers, network adapters, and LED drivers. However, the efficiency and standby power requirements have been improved to a high standard due to the new trends of DOE (Department Of Energy) Level VI and COC (Code Of Conduct specifications) V5. The major drawbacks of PSR include poor regulation due to inaccurate feedback and difficulty in acquiring acceptable regulation. A novel adaptive blanking strategy for constant current and constant voltage regulation is proposed in this paper. An accurate model for the sample blanking time related to transformer leakage inductance and the metal-oxide-semiconductor field-effect transistor (MOSFET) parasitic capacitance is established. The proposed strategy can achieve accurate detection for ultra-low standby power. In addition, numerous control factors are analyzed in detail to eliminate the influence of leakage inductance on the loop stability. A dedicated controller integrated circuit (IC) with a power MOSFET is fabricated to verify the effectiveness of the proposed control strategy. Experimental results demonstrated that the prototype based on the proposed IC has excellent performance.

Mobile Application Privacy Leak Detection and Security Enhancement Research (모바일 어플리케이션 개인정보 유출탐지 및 보안강화 연구)

  • Kim, Sungjin;Hur, Junbeom
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.1
    • /
    • pp.195-203
    • /
    • 2019
  • Mobile applications stores such as Google Play Store and Apple App Store, are widely used to distribute a variety of applications including finance, shopping, and entertainment. Recently, however, vulnerabilities of the mobile applications are likely to violate users' privacy such as personal information leakage. In this paper, we classify mobile applications that can be download from mobile stores, and analyze the personal information that could be leaked when users are using the mobile applications. As a result of analysis, we found that personal information are leaked in some widely used mobile applications in practice. On the basis of our experiment results, we propose some mitigations to enhance security of the mobile applications and prevent leakage of personal information.

A Research on the Effectiveness of the Vulnerability Detection Against Leakage of Proprietary Information Using Digital Forensic Methods (디지털 포렌식 기법을 통한 기업 정보유출에 대한 취약점 탐지 효율성에 관한 연구)

  • Park, Yoon-Jae;Chae, Myung-Sin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.464-472
    • /
    • 2017
  • In the ICT (Information and Communication Technology) convergence security environment, a lot of companies use an external public web system for the external disclosure and sharing of product information, manufacturing technology, service manualsand marketing materials. In this way, the web system disclosed on the Internet is an important aspect of cyber security management and has an always-on vulnerability requiringan information protection solution and IT vulnerability checks. However, there are limits to vulnerability detection management in anexternal environment. In this study, in order to solvethese problems, we constructed a system based on digital forensics and conducted an empirical study on the detection of important information in enterprises by using forensic techniques. It was found thatdue to the vulnerability of web systems operated in Korea and overseas, important information could be revealed,such as the companies' confidential data and security management improvements. In conclusion, if a system using digital forensic techniques is applied in response to theincreasing number of hacking incidents, the security management of vulnerable areas will be strengthened and the cyber security management system will be improved.

Development of Contaminant Leakage Detection System Using Electrical Resistance Measurement: I. Variations of Electrical Properties of Subsurface due to Contaminants (전기저항 측정기법을 이용한 오염물질 누출감지시스템의 개발: I. 오염물질에 의한 지반의 전기적 특성 변화)

  • 오명학;박준범;김영진;홍성완;이용훈
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.215-224
    • /
    • 2001
  • The concept that the electrical properties of subsurface material can be affected by the introduction of contaminants might be applicable fur developing the leakage detection system for petroleum hydrocarbons of underground storage tanks and leachate coming from landfill. Investigations were conducted with diesel, NaCl solution, and leachate by laboratory tests. Simulation test was performed leaking at a certain point in the field. The measured resistance was exponentially decreased as the water content of uncontaminated unsaturated sand was increased. The resistance of soil was increased by diesel but decreased by NaCl solution or leachate. The optimum electrode spacings were found for NaCl solution, leachate and diesel. Electrolytic solutions were better detected by wider spacing than non electrolytic solution.

  • PDF

Development of leakage detection model in water distribution networks applying LSTM-based deep learning algorithm (LSTM 기반 딥러닝 알고리즘을 적용한 상수도시스템 누수인지 모델 개발)

  • Lee, Chan Wook;Yoo, Do Guen
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.8
    • /
    • pp.599-606
    • /
    • 2021
  • Water Distribution Networks, one of the social infrastructures buried underground, has the function of transporting and supplying purified water to customers. In recent years, as measurement capability is improved, a number of studies related to leak recognition and detection by applying a deep learning technique based on flow rate data have been conducted. In this study, a cognitive model for leak occurrence was developed using an LSTM-based deep learning algorithm that has not been applied to the waterworks field until now. The model was verified based on the assumed data, and it was found that all cases of leaks of 2% or more can be recognized. In the future, based on the proposed model, it is believed that more precise results can be derived in the prediction of flow data.

Detection of Abnormal Leakage and Its Location by Filtering of Sonic Signals at Petrochemical Plant (비정상 음향신호 필터링을 통한 플랜트 가스누출 위치 탐지기법)

  • Yoon, Young-Sam;Kim, Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.6
    • /
    • pp.655-662
    • /
    • 2012
  • Gas leakage in an oil refinery causes damage to the environment and unsafe conditions. Therefore, it is necessary to develop a technique that is able to detect the location of the leakage and to filter abnormal gas-leakage signals from normal background noise. In this study, the adaptation filter of the finite impulse response (FIR) least mean squares (LMS) algorithm and a cross-correlation function were used to develop a leakage-predicting program based on LABVIEW. Nitrogen gas at a high pressure of 120 kg/$cm^2$ and the assembled equipment were used to perform experiments in a reverberant chamber. Analysis of the data from the experiments performed with various hole sizes, pressures, distances, and frequencies indicated that the background noise occurred primarily at less than 1 kHz and that the leakage signal appeared in a high-frequency region of around 16 kHz. Measurement of the noise sources in an actual oil refinery revealed that the noise frequencies of pumps and compressors, which are two typical background noise sources in a petrochemical plant, were 2 kHz and 4.5 kHz, respectively. The fact that these two signals were separated clearly made it possible to distinguish leakage signals from background noises and, in addition, to detect the location of the leakage.

A Study on the Reliability Improvement Plan on Electric Leakage & Ground Fault of Low-voltage Electrical Line (저압전로의 누전.지락에 대한 신뢰성향상 방안에 관한 연구)

  • Kang, Kyung-Won;Yoon, Myung-O;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.136-145
    • /
    • 2011
  • One of a large proportion among the causes of fire is electrical factors, and of fire by electric factors, the accident which accounted for over certain percentage is electric leakage and ground fault. In order to reduce the electric leakage and ground fault, the technical guidelines on the protection of ground fault in the low-voltage electrical line (KECG 1091-2011) was amended for reflecting recent international standard, IEC 60364-4-41, and new conservation methods, which improved the reliability by recovering the facility's all-time use operation and breakdown defect, was on the rise. Accordingly, in this paper, after grasping the fire's status for last 10 years and analyzing the risk of electrical fires, and as a way to improve the electric leakage and ground fault accident which accounted for more than certain percentage, the revision of KECG 1091-2011 will be reviewed. And then, after applying to the preventive conservation methods in order to enhance the protection reliability of electric leakage and ground fault detection, the problems at issue routine inspection scheme and durable years scheme in time-scheduled conservation method are listed, along with suggestion of the problem-solving scheme, and the leakage current integrated monitoring systems and digital electric leakage devices by status monitor conservation method will be proposed.