• Title/Summary/Keyword: lead measurement

Search Result 709, Processing Time 0.025 seconds

An Integrated Approach to Measuring Supply Chain Performance

  • Theeranuphattana, Adisak;Tang, John C.S.;Khang, Do Ba
    • Industrial Engineering and Management Systems
    • /
    • v.11 no.1
    • /
    • pp.54-69
    • /
    • 2012
  • Chan and Qi (SCM 8/3 (2003) 209) developed an innovative measurement method that aggregates performance measures in a supply chain into an overall performance index. The method is useful and makes a significant contribution to supply chain management. Nevertheless, it can be cumbersome in computation due to its highly complex algorithmic fuzzy model. In aggregating the performance information, weights used by Chan and Qi-which aim to address the imprecision of human judgments-are incompatible with weights in additive models. Furthermore, the default assumption of linearity of its scoring procedure could lead to an inaccurate assessment of the overall performance. This paper addresses these limitations by developing an alternative measurement that takes care of the above. This research integrates three different approaches to multiple criteria decision analysis (MCDA)-the multiattribute value theory (MAVT), the swing weighting method and the eigenvector procedure-to develop a comprehensive assessment of supply chain performance. One case study is presented to demonstrate the measurement of the proposed method. The performance model used in the case study relies on the Supply Chain Operations Reference (SCOR) model level 1. With this measurement method, supply chain managers can easily benchmark the performance of the whole system, and then analyze the effectiveness and efficiency of the supply chain.

Non-Controlling Interests and Proxy of Real Activities Manipulation in Stakeholder-Oriented Corporate Governance

  • FUJITA, Kento;YAMADA, Akihiro
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.9 no.10
    • /
    • pp.105-113
    • /
    • 2022
  • The purpose of this paper is to analyze the relationship between the ratio of non-controlling shareholder interests (minority equity ratio, MER) and the measurement error in real activities manipulation (RM) proxy for Japanese firms. Many Japanese firms have practiced stakeholder-oriented corporate governance systems. Previous studies suggest that the higher the MER, the more Japanese businesses tend to employ management techniques for the group's sales growth while also reallocating resources inside the group to reduce principal-principal conflicts. Such differences in management strategies by firms could lead to measurement error in the RM proxy. The analysis uses 16,450 firm-years listed on the Tokyo Stock Exchange. The results of our analysis show that there is a positive relationship between MER and the RM proxy, and high persistence of RM proxies, suggesting that the RM proxies may contain measurement error. We also find that MER is correlated with variables associated with management strategy and that controlling for these variables can reduce the measurement error of RM proxy in firms with large MER. This study extends previous research on measurement error in RM proxy by relating them to ownership structure and corporate governance. This paper would contribute to researchers examining issues related to RM.

Assessment of DVC measurement uncertainty on GFRPs with various fiber architectures

  • Bartulovic, Ante;Tomicevic, Zvonimir;Bubalo, Ante;Hild, Francois
    • Coupled systems mechanics
    • /
    • v.11 no.1
    • /
    • pp.15-32
    • /
    • 2022
  • The comprehensive understanding of the fiber reinforced polymer behavior requires the use of advanced non-destructive testing methods due to its heterogeneous microstructure and anisotropic mechanical proprieties. In addition, the material response under load is strongly associated with manufacturing defects (e.g., voids, inclusions, fiber misalignment, debonds, improper cure and delamination). Such imperfections and microstructures induce various damage mechanisms arising at different scales before macrocracks are formed. The origin of damage phenomena can only be fully understood with the access to underlying microstructural features. This makes X-ray Computed Tomography an appropriate imaging tool to capture changes in the bulk of fibrous materials. Moreover, Digital Volume Correlation (DVC) can be used to measure kinematic fields induced by various loading histories. The correlation technique relies on image contrast induced by microstructures. Fibrous composites can be reinforced by different fiber architectures that may lead to poor natural contrast. Hence, a priori analyses need to be performed to assess the corresponding DVC measurement uncertainties. This study aimed to evaluate measurement resolutions of global and regularized DVC for glass fiber reinforced polymers with different fiber architectures. The measurement uncertainties were evaluated with respect to element size and regularization lengths. Even though FE-based DVC could not reach the recommended displacement uncertainty with low spatial resolution, regularized DVC enabled for the use of fine meshes when applying appropriate regularization.

Measurement of the Spatial Scattering Dose by Opening, Closing Door and Installing Shielding : A Study on the Reduction of Exposure Dose in Radiography (문 개폐 여부와 차폐체 설치 유무에 따른 공간산란선량 측정 : X선 촬영 시 피폭선량 감소방안에 대한 연구)

  • Yoon, Hong-Joo;Lee, Yong-Ki;Lee, In-Ja
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.477-482
    • /
    • 2019
  • Recently, due to the increased use of medical radiation, the radiation exposure of radiation workers should be considered as well as medical exposure of patients. And it is recommended to close the door during radiography. however, In this study, when the door was inevitably opened for radiography, the proposed method was to install the shield as a method of reducing the exposure dose. And its efficiency was analyzed. In simple chest radiography, the measurement point was changed according to the measurement location. Dose rate were measured 10 times for each condition using a dosimeter. And the average value was derived. Using this, the change of dose according to the opening and closing of the door and the installation of the shield was analyzed. Using this, we compared and analyzed the dose change according to the door opening and closing and the installation of the shield, and significance was verified through the SPSS ver. 24. Depending on whether the door was opened or closed, 11,215.35%, 159.0%, 101.9% increased in front of the door in the consol room, behind the wall and behind the lead glass. Depending on the installing of the shield, the 49.2%, 29.6%, 19.9%, 30.6% decrease in front of the door in the examination and consol room, behind the wall and lead glass. In addition, statistical analysis was showed that there were significant differences in both the results according to whether the door was opened or closed and shielding(p<.05). Close the door during radiography. However, when the door should be opened, it was confirmed that the dose rate were reduced by installing the shield. Therefore, to optimize radiation protection, it is recommended to install shields when opening the door.

Effect of Deposition Parameters on the Morphology and Electrochemical Behavior of Lead Dioxide

  • Hossain, Md Delowar;Mustafa, Chand Mohammad;Islam, Md Mayeedul
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.197-205
    • /
    • 2017
  • Lead dioxide thin films were electrodeposited on nickel substrate from acidic lead nitrate solution. Current efficiency and thickness measurements, cyclic voltammetry, AFM, SEM, and X-ray diffraction experiments were conducted on $PbO_2$ surface to elucidate the effect of lead nitrate concentration, current density, temperature on the morphology, chemical behavior, and crystal structure. Experimental results showed that deposition efficiency was affected by the current density and solution concentration. The film thickness was independent of current density when deposition from high $Pb(NO_3)_2$ concentration, while it decreased for low concentration and high current density deposition. On the other hand, deposition temperature had negative effect on current efficiency more for lower current density deposition. Cyclic voltammetric study revealed that comparatively more ${\beta}-PbO_2$ produced compact deposits when deposition was carried out from high $Pb(NO_3)_2$ concentration. Such compact films gave lower charge discharge current density during cycling. SEM and AFM studies showed that deposition of regular-size sharp-edge grains occurred for all deposition conditions. The grain size for high temperature and low concentration $Pb(NO_3)_2$ deposition was bigger than from low temperature and high concentration deposition conditions. While cycling converted all grains into loosely adhered flappy deposit with numerous pores. X-ray diffraction measurement indicates that high concentration, high temperature, and high current density favored ${\beta}-PbO_2$ deposition while ${\alpha}-PbO_2$ converted to ${\beta}-PbO_2$ together with some unconverted $PbSO_4$ during cycling in $H_2SO_4$.

Exposed level of workers in the factory next to a lead recycling factory (연 재생공장 인접 근로자들의 연 폭로정도에 관한 조사)

  • Kim, Jin-Ha;Lee, Duk-Hee;Lee, Yong-Hwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.693-700
    • /
    • 1996
  • The purpose of this study was to determine whether workers at a factory next to a lead recycling factory in Pusan, were affected by lead contamination. The mean air lead concentration of lead recycling factory was $0.21mg/m^3(TWA=0.05mg/m^3)$. Thirty-nine male workers of Factory A, Cr. plating factory next to the lead recycling factory were exposed group and a comparison group, 62 male workers of Factory B were selected from another Cr. plating factory about 8.5km away from lead recycling factory. Air lead concentration of each workplace was checked for 4 times from August f to August 20 in 1995 by low volume air sampler. Each subject was interviewed about age, life-style, smoking, work history, and residence etc, and venous blood was drawn for lead measurement by graphite furnace atomic absorption spectrometry. We have observed that air lead concentration and blood lead concentration of Factory A was higher than Factory $B(2.6{\pm}1.6\;Vs.\;1.2{\pm}0.2{\mu}g/m^3,\;14.9{\pm}1.6\;Vs.\;12.2{\pm}1.6{\mu}g/dl)$. We believe that other environmental lead sources such as transportation and residence did not affect air lead and blood lead concentration differences of both factory. We concluded that high air lead and blood lead concentration of Factory A were caused by lead contamination generated by the neighboring lead recycling factory.

  • PDF

Measurement method of ground impedance for the grounding grid (접지그리드의 접지임피던스 측정 기법)

  • Lee, Bok-Hee;Choi, Jong-Hyuk;Choi, Young-Chul;Yoo, Jae-Duk;Beak, Young-Hwan;Kim, Dong-Seong;Shin, Hee-Kyung;Yoo, Yang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1487_1488
    • /
    • 2009
  • In these days, the common grounding systems are adapted in most large structures. In order to evaluate the performance of grounding system, it is needed to measure ground impedance. Measuring methods of ground impedance for a large scale grounding systems have not been yet presented in detail. In this paper, we analyze earth mutual resistance and mutual coupling of $15{\times}15m$ grounding grid in different arrangements of auxiliary electrode. As a results, the auxiliary electrodes are installed where the error rate due to earth mutual resistance is less than 5%. Also, the potential lead is installed at obtuse angle from the current lead and the overlapped length between potential lead and grounding grid are minimized.

  • PDF

Evaluation of Mechanical Properties and FEM Analysis on Thin Foils of Copper (구리 박막의 기계적 물성 평가 및 유한요소 해석)

  • Kim Yun-Jae;An Joong-Hyok;Park Jun-Hyub;Kim Sang-Joo;Kim Young-Jin;Lee Young-Ze
    • Tribology and Lubricants
    • /
    • v.21 no.2
    • /
    • pp.71-76
    • /
    • 2005
  • This paper compares of mechanical tensile properties of 6 kinds of copper foil. The beam lead made with copper foil. Different from other package type such as plastic package, Chip Size Package has a reliability problem in beam lead rather than solder joint in board level. A new tensile loading system was developed using voice-coil actuator. The new tensile loading system has a load cell with maximum capacity of 20 N and a non-contact position measuring system based on the principle of capacitance micrometry with 0.1nm resolution for displacement measurement. Strain was calculated from the measured displacement using FE analysis. The comparison of mechanical properties helps designer of package to choose copper for ensuring reliability of beam lead in early stage of semiconductor development.

Raw Material and Provenance of Chosen-Tongbo (I) (조선통보의 주조원료와 산지 연구(I))

  • Kang, Hyung Tae;Kim, Gyu Ho;Huh, Woo Young;Hirao, Yoshimitsu
    • Journal of Conservation Science
    • /
    • v.16 s.16
    • /
    • pp.15-20
    • /
    • 2004
  • Two pieces of choson-Tongue(朝鮮通寶) minted at 1423 A.D. were analyzed by atomic absorption spectroscopy and neutron activation analysis. The measurement of lead isotope ratios was also carried out in order to predict the provenance of raw materials used for minting. The Chosen-Tongue was minted as bronze having the chemical compositions of $Cu\;90\%,\;Pb\;3\~4\%,\;Sn\;2\~3\%$, which were different from the typical composition of Chinese and Japanese coins. The results of lead isotope ratios showed that the provenance of raw materials used for minting had a possibility to be originated from South China. And application of statistical linear discriminant analysis (SLDA) to the provenance of lead used for minting of Chosen-Tongue was confirmed.

  • PDF

Measurement of maximum deviation of leads using partial image of SMD mounted on PCB (PCB에 장착된 SMD 의 부분영상을 이용한 리드의 최대 벗어난 양의 측정)

  • Shin, Dong-Won;You, Jun-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.6
    • /
    • pp.698-704
    • /
    • 1999
  • There are several types of defects of SMDs mounted on PCB, that is, missing components, misalignment, wrong parts and poor solder joints. This research study mainly focuses on measuring of deviation of SMD leads using the partial image of component, not using the full image. This processing based on the partial image has the advantage of the reduction in calculation time compared to the full image. Since position of lead is calculated with respect of the reduction in calculation time compared to the full image. Since position of lead is calculated with respect to pad, the accuracy of the system is not dependent on percise positioning stage. The grabbed image of gray scale is converted into binary format using a cutomatic threshold. After small fragments in the image is removed by a series of morphology operations such as opening and closing, the centroids of PCB pads and SMD leads is obtained together with labeling of blobs. Translational shift and rotationial angle of SMD are succedingly estimated using above information and chip data. The expression that can calculate the maximum deviation of leads with respect to PCB pads has been derived, and inferior mounting of SMD is judged by a given criterion. Some experiments have been executed to verify this measuring scheme.

  • PDF