• Title/Summary/Keyword: latex particles sizes

Search Result 6, Processing Time 0.02 seconds

Effect of Latex Particle Size, Base Paper Grammage and Coating Color Concentration on Printing Quality of Coated Paper (Latex 입경과 원지 평량 및 칼라농도가 도공지의 인쇄품질에 미치는 영향)

  • Lee, Y.K.;Yoo, S.J.;Cho, B.U.;Kim, Y.S.;Nam, B.K.;Choi, S.M.
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.39 no.4
    • /
    • pp.29-37
    • /
    • 2007
  • The effects of latex particle size, basis weight of base paper and coating color concentration on the printing quality of coated paper were investigated. Coating colors were prepared with five types of latexes having different particle sizes. Coated papers were produced with high solid coating colors and with low solid coating colors in a industrial coater, respectively. In high solid coating colors, rheology modifier was used and GCC content was high. It was concluded that, in order to control binder migration and hence print mottle, latex particle sizes shall be controlled as well as formation, sizing degree and roughness of basis paper.

A Study on Particle Diffusion to Develop Faraday Cup Array of Particle Beam Mass Spectrometer System (Faraday cup array 개발을 위한 Particle Beam Mass Spectrometer 시스템 내에서의 입자 확산 연구)

  • Mun, Ji-Hun;Shin, Yong-Hyun;Kim, Tae-Sung;Kang, Sang-Woo
    • Particle and aerosol research
    • /
    • v.8 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • The Faraday cup electrode of different size has been developed and evaluated to investigate the diffusion effect of particles by Brownian motion in a particle beam mass spectrometer(PBMS). Particles which focused and accelerated by aerodynamic lens are charged to saturation in an electron beam, and then deflected electrostatically into a Faraday cup detector for measurement of the particle current. The concentration of particles is converted from currents detected by Faraday cup. Measurements of particle current as a function of deflection voltage are combined with measured relationships between particle velocity and diameter, charge and diameter, and mass and diameter, to determine the particle size distribution. The particle currents were measured using 5, 10, 20, 40 mm sized Faraday cup that can be move to one direction by motion shaft. The current difference for each sizes as a function of position was compared to figure out diffusion effect during transport. Polystyrene latex(PSL) 100, 200 nm sized standard particles were used for evaluation. The measurement using 5 mm sized Faraday cup has the highest resolution in a diffusion distance and the smaller particles had widely diffused.

Comparison Study of the TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109 and HCT Particle Sensor 3030 for PM2.5 measurement (TSI Aerodynamic Particle Sizer 3321, Grimm Aerosol Spectrometer 1.109, HCT Particle Sensor 3030을 이용한 PM2.5 측정결과 비교)

  • Kim, Du-Yong;Chung, Hyuck;Park, Jae-Hong;Hyun, Jun-Ho;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.8 no.1
    • /
    • pp.9-15
    • /
    • 2012
  • Three different commercial particle counters were used to measure the PM2.5 particles in this study. An Aerosol Spectrometer (AS) 1.109 model of Grimm and a Particle Sensor (PS) 3030 model of HCT were compared with an Aerodynamic Particle Sizer (APS) 3321 model of TSI. The responses of these instruments were compared for four sizes ($1.0{\mu}m$, $1.5{\mu}m$, $2.0{\mu}m$ and $2.5{\mu}m$) of polystyrene latex (PSL) particles and indoor air particles of the office room. The mode diameter, particle size distribution and total particle number concentration of PSL particles were measured by each instrument. In the office room, the total particle number concentration was measured for 25 minutes. In results of particle size distribution and mode diameter, the APS 3321 (52 size-channels) was more accurate than the AS 1.109 (31 size-channels) and PS-3030 (10-szie channels) since the APS has more number of size-channels than the other instruments. However, AS 1.109 and PS-3030 provided similar results of total particle number concentration to those from the APS 3321. In results of office room test, there were no significant difference from each instrument similar to results of PSL test.

Induction of Differentiation of the Human Histocytic Lymphoma Cell Line U-937 by Hypericin

  • Kim, Joo-Il;Park, Jae-Hoon;Park, Hee-Juhn;Choi, Seung-Ki;Lee, Kyung-Tae
    • Archives of Pharmacal Research
    • /
    • v.21 no.1
    • /
    • pp.41-45
    • /
    • 1998
  • Hypericin, a photosensitizing plant pigment, was found to be a potent inducer of differentiation of human myeloid leukemia U-937 cells. At a concentration of $0.2{\mu}M$, hypericin exhibited 50% growth inhibition. An effect on cell differentiation by hypericin was assessed by its ability to induce phagocytosis of latex particles, and to reduce nitroblue tetrazolium (NBT). Approximately 51% of $0.2{\mu}M$ hypericin-treated cells were stained with NBT and 63% showed phagocytic activity. In order to establish whether hypericin induces differentiation of U-937 cells to macrophage or granulocyte, esterase activities and cell sizes were measured. When U-937 cells were treated with $0.2{\mu}M$ and $0.15{\mu}M$ of hypericin, the .alpha.-naphthyl acetate esterase activity was increased by 38.4% and 48.1%, respectively, but naphthol AS-D chloroacetate esterase activity was not influenced. The size of hypericin-treated cells in terms of cell mass was larger than that observed in untreated cells as determined by flow cytometry. Protein kinase C (PKC) inhibitor, NA-382, decreased the NBT reducing activity of hypericin, whereas a cAMP-dependent protein kinase A (PKA) inhibitor, H-89, did not show any influence on the differentiations. These results indicate that hypericin triggers differentiation toward monocyte/macrophage lineage by PKC stimulation.

  • PDF

고농도 도공과 저농도 도공에서의 라텍스 입자경에 따른 건조조건 변화별 인쇄적성 상관성 연구

  • Lee, Y.K.;Yoo, S.J.;Cho, B.U.;Kim, Y.S.;Nam, B.K.;Choi, S.M.
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2008.04a
    • /
    • pp.60-74
    • /
    • 2008
  • 일반적으로 종이 도공의 바인더로 사용되는 라텍스는 입자경이 작을수록 도공층이 부동화 되기 전에 도공층 내에서 원지 혹은 도공층 표면으로의 이동 특성이 강해져서 최종 도공지의 인쇄적성에 다양한 품질의 변화를 보일 수 있다. 라텍스는 원지와 접촉하는 순간부터 원지의 특성에 따라 원지 방향으로 1차 마이그레이션이 일어나고 건조공정의 건조조건(IR-Infra Red 혹은 Hot Air Dryer)에 따라 도공층 표면으로의 2차 마이그레이션이 일어나며 이로 인해 도공층 내에서 Z-방향으로 바인더 분포가 불균일하게 분포하게 됨으로서 인쇄 모틀 현상에도 영향을 미치게 된다. 따라서 본 논문에서는 도공액의 농도와 라텍스의 입자경 그리고 건조조건에 따른 도공층의 구조변화가 최종인쇄적성에 미치는 상관성을 검토하였다.

  • PDF

Effect of Sample-loading on Fractionation Efficiency (FE) in a Large Scale Splitter-less Gravitational SPLITT Fractionation (GSF)

  • Lee, Seung-Ho;Lee, Ji-Yeon;Lee, Tae-Woo;Jung, Euo-Chang;Cho, Sung-Kwang
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.12
    • /
    • pp.4291-4296
    • /
    • 2011
  • Gravitational SPLITT fractionation (GSF) provides separation of colloidal particles into two subpopulations in a preparative scale. Conventionally, GSF is carried out in a thin rectangular channel having two inlets and two outlets at the top and bottom of the channel, respectively. And the channel is equipped with two flow-splitters, one between the top and bottom inlets and another between the top and bottom outlets. A large scale splitter-less GSF system had been developed, which was designed to operate in the full feed depletion (FFD) mode. In the FFD mode, there is only one inlet through which the sample is fed, thus preventing the sample dilution. In this study, the effect of the sample-loading (in the unit of g/hr) on the fractionation efficiency (FE, number% of particles in a GSF fraction that have the sizes expected by theory) of the new large scale splitter-less FFD-GSF system was investigated. The system was tested in the sample-loading range of 3.0-12.0 g/hr with polyurethane latex beads (PU) and sea-sediment. It was found that there is an optimum range in the sample-loading for a FFD-GSF separation. It was also found that there is a general tendency of FE decreasing as the concentration of the sample suspension increases.